Rules on Safety Standards for Construction Machinery
286157 · 2026-10-01
Chapter 1 General Provisions
Article 1 (Purpose) Pursuant to Article 12 of the Construction Machinery Management Act, the purpose of this Rule is to establish standards regarding the structure, specifications, performance, etc., of construction machinery so as not to impede the safe operation or use of construction machinery.
Article 2 (Definitions) The definitions of terms used in this Rule are as follows. <Amended 2009.10.21, 2013.5.27, 2018.6.1, 2020.7.31, 2021.8.27, 2026.3.31>
1. "Centerline" refers to a straight line passing through the center points of the foremost and rearmost axles in wheeled construction machinery, and a longitudinal straight line parallel to the ground passing through the center point between the two tracks in tracked construction machinery.
2. "Center plane" refers to a plane perpendicular to the ground that includes the centerline of the construction machinery.
3. "Axle of a tire-type construction machine" refers to a straight line connecting the centers of the left and right wheels connected to the same axle, which intersects the center plane of the construction machine at a right angle.
4. "Axis of a tracked construction machine" refers to the straight line connecting the centers of the left and right idler wheels, and the straight line connecting the centers of the left and right drive wheels, which intersects the center plane of the construction machine at a right angle.
4-2. "Indirect viewing device" refers to a device for securing visibility of the front, rear, side, top, or bottom of construction machinery using a mirror or image verification device.
5. "Length" refers to the shortest distance between two transverse vertical planes formed by the front and rear ends of a construction machine in a self-weight state with a working device attached. However, the devices specified in each of the following subparagraphs are not included at the front and rear ends of the construction machine.
A. Indirect clock mechanism and device for fixing the same
B. Cargo box cover and fixing device thereof
C. Door handle and door fixing device for earthwork construction machinery
D. Devices recognized by the Minister of Land, Infrastructure and Transport, such as antennas and sensing devices installed on the exterior of construction machinery, and devices for fixing them
6. "Width" refers to the shortest distance between the two vertical planes in the direction of the end lines formed by the left and right ends of a construction machine in a self-weight state with a working device attached. However, the devices specified in each of the following subparagraphs are not included at the left and right ends of the construction machine.
A. Indirect clock mechanism and device for fixing the same
B. Cargo box cover and fixing device thereof
C. Door handle and door fixing device for earthwork construction machinery
D. Devices recognized by the Minister of Land, Infrastructure and Transport, such as antennas and sensing devices installed on the exterior of construction machinery, and devices for fixing them
7. "Height" refers to the shortest distance from the horizontal plane formed by the uppermost end of a construction machine in its self-weight state, equipped with a working device, to the ground. However, devices recognized by the Minister of Land, Infrastructure and Transport, such as antennas and sensing devices installed on the exterior of the construction machine, and their fixing devices, are not included at the uppermost end of the construction machine.
8. "Minimum ground clearance" refers to the shortest distance from the lowest part of a vehicle body to the ground, located within a distance equivalent to 25 percent of the wheelbase or the distance between track centers in each left and right direction from the center plane of a construction machine in its self-weight state with a work device attached.
9. "Shoe plate" refers to a plate made of metal, synthetic resin, rubber, etc., as a component constituting an endless track.
10. "Shoe span" refers to the shortest distance between two vertical planes in the longitudinal direction passing through both ends of the shoe.
11. "Track" refers to shoes connected by links.
12. "Endless track" refers to a track in which the shoe plates at both ends are continuously connected by connecting devices such as pins or bolts.
13. "Grauzer" refers to a pin protruding from the outer part of the shoe board.
14. "Wheelbase" refers to the shortest distance between two transverse vertical planes passing through the centers of the front and rear axles of a wheeled construction machine. In the case of three or more axles, the distances shall be designated as the first wheelbase, second wheelbase, third wheelbase, and so on, starting from the front wheelbase.
15. "Tumbler center-to-center distance" refers to the shortest distance between two transverse vertical planes passing through the axis centers of the driving wheel and the idler wheel, respectively, of a tracked construction machine placed on a horizontal plane. However, in the case of a triangular track, it refers to the shortest distance between two transverse vertical planes passing through the axis centers of the front idler wheel and the rear idler wheel, respectively.
16. "Wheel track" refers to the shortest distance between two longitudinal vertical planes passing through the center of the widths of the opposing left and right wheels of a wheeled construction machine (or the center of the widths of the double wheels in the case of double wheels), and the front wheel track is designated as the first wheel track, second wheel track, and so on.
17. "Distance between track centers" refers to the shortest distance between two longitudinal vertical planes passing through the centers of the left and right track widths of a tracked construction machine.
18. "Empty weight" refers to the weight of a construction machine in a state ready for immediate operation, fully filled with fuel, coolant, lubricating oil, etc., and loaded or attached with portable tools, work implements, and a spare tire (applicable only to construction machinery equipped with a spare tire). In this case, the weight of the operator shall be excluded, and for tower cranes, it shall be the weight while the machine is capable of standing under its own power without auxiliary means of support or fixation.
19. "Operating weight" refers to the weight of the construction machinery plus its own weight with the minimum number of operators required to operate the machinery on board, and the weight of one operator is assumed to be 65 kilograms.
20. "Maximum load capacity" refers to the weight of the loaded material when the material permitted for loading on construction machinery is loaded to the maximum extent in the permitted location.
21. "Gross weight" refers to the sum of the empty weight, the maximum payload, and the weight of the occupants, including the pilot; the weight of one occupant is assumed to be 65 kilograms.
22. "Wheel load" refers to the load applied to each wheel due to the weight of a construction machine in a horizontal state.
23. "Axle load" refers to the sum of the wheel loads of all wheels connected to a single axle of a tire-type construction machine in a horizontal position, and is calculated separately for gross weight and self-weight conditions.
24. "Braking distance" refers to the distance traveled from the moment the braking system is engaged until the vehicle comes to a stop when a construction machine traveling at a constant initial braking speed applies sudden braking, and is based on a flat and dry asphalt paved road surface.
25. "Initial braking speed" refers to the driving speed of the construction machine at the moment the operator recognizes the need to brake.
26. "Minimum turning radius" refers to the radius of the trajectory having the largest radius among the circular trajectories traced by the centers of wheels or drive wheels when a construction machine placed on a horizontal plane turns.
27. "Maximum driving speed" refers to the maximum speed at which construction machinery can travel under operating weight on a flat and dry asphalt paved surface.
28. "Rated output" refers to the maximum output that a prime mover equipped for the purpose of construction machinery can continuously generate.
29. "Maximum torque" refers to the maximum value of torque that a prime mover can generate.
30. "Climbing ability" refers to the ability of construction machinery in an operating weight state to ascend an inclined surface, and is indicated by the maximum angle of inclination of the inclined surface. However, for construction machinery falling under each of the following subparagraphs, the maximum load capacity state shall be used as the basis.
A. Forklift
B. Dump Truck
C. Delete <2009.10.21>
D. Concrete Mixer Truck
E. Asphalt Spreader
31. "Backhoe" refers to the direction in which the bucket digs and pulls toward the pilot.
32. A "shovel" refers to a bucket whose excavation direction is opposite to that of a backhoe.
33. The term "heavy construction machinery" refers to construction machinery falling under any of the following subparagraphs.
A. Construction machinery exceeding 16.7 meters in length
B. Construction machinery with a width exceeding 2.5 meters
C. Construction machinery exceeding 4.0 meters in height
D. Construction machinery with a minimum turning radius exceeding 12 meters
E. Construction machinery with a gross weight exceeding 40 tons. However, for excavators, loaders, and forklifts, this refers to cases where the operating weight exceeds 40 tons.
B. Construction machinery with an axle load exceeding 10 tons in gross weight condition. However, for excavators, loaders, and forklifts, this refers to cases where the axle load exceeds 10 tons in operating weight condition.
34. "Electric construction machinery" refers to construction machinery manufactured for the purpose of operation or use by utilizing a battery or an external power source.
35. "Truck-type construction machinery" refers to construction machinery manufactured using a vehicle produced by a person assigned a Manufacturer Identification Code (WMI) as defined by the International Organization for Standardization (ISO).
36. "Earthwork construction machinery" refers to construction machinery that performs operations such as direct excavation, loading, transport, delivery, spreading, and compaction of soil, etc., including bulldozers, excavators, loaders, scrapers, dump trucks, motor graders, rollers, drilling rigs, pile drivers, and pile extractors. However, truck-type construction machinery is excluded.
37. "Tipping protection structure" refers to a structure designed to reduce the risk of injury to an operator wearing a seatbelt being pinned down when construction machinery overturns.
38. "Overturn protection structure" refers to a structure designed to reduce the risk of injury to an operator wearing a seatbelt being pinned down when construction machinery overturns.
39. "Falling object protection structure" refers to a structure that protects the pilot from objects falling from above the cockpit.
40. "Deformation limit volume" refers to the minimum space required to protect a pilot wearing a safety helmet while seated in the cockpit, and the dimensions shall conform to Attached Table 1.
41. "Seating reference point" refers to a standard design position determined by applying the standards set forth in each of the following subparagraphs, or a standard design position determined by a person who has obtained approval regarding a construction machinery type or reported such type pursuant to Article 20, Paragraph 1 of the Construction Machinery Management Act (hereinafter referred to as "manufacturer, etc.").
A. For earthmoving construction machinery, if the seat can be adjusted forward/backward and up/down, adjust it to the center position, and the seat backrest is also adjusted to the center position.
B. For construction machinery other than earthmoving machinery, if the seat is adjustable forward and backward, position it at the rearmost position; if the seat is adjustable up and down, position it at the lowest position; and if the seat backrest is adjustable, adjust it to the standard design angle.
42. "Main braking system" refers to the primary reduction gear used by an operator to decelerate or stop construction machinery.
43. "Anti-lock braking system" refers to a device that automatically regulates the amount of wheel slippage during braking by detecting and analyzing the amount of wheel rotation and adjusting the braking force of the wheel.
44. "Auxiliary braking device" refers to a device designed to reduce the load on the main braking system, such as an exhaust braking device, capable of maintaining a braking effect over an extended period.
45. "Track height" refers to the shortest distance from the highest point of a caterpillar track to the ground. In this case, the grouser is deemed not to exist.
46. "Drive battery" refers to a battery that stores electrical energy for the purpose of operating and driving construction machinery, or an electrical energy storage medium that performs a similar function.
47. "Drive motor" refers to a device that converts electrical energy into mechanical energy capable of rotational motion for the purpose of driving construction machinery.
48. "High-voltage electrical device" refers to an electrical device, such as a drive battery, power converter, drive motor, or fuel cell, among which the operating voltage is DC exceeding 60 volts and not exceeding 1,500 volts, and AC (referring to effective value) exceeding 30 volts and not exceeding 1,000 volts.
49. "Live conductor" refers to a conductor or conductive part that is electrically energized under normal operating conditions.
50. "Hydrogen fuel cell" refers to a device that generates electrical energy using hydrogen.
51. "Hydrogen fuel cell construction machinery" refers to construction machinery that uses a hydrogen fuel cell as a power source.
52. "Emergency Automatic Braking System" refers to a device that automatically activates a braking system to decelerate or stop construction machinery for the purpose of mitigating or avoiding a collision by detecting a frontal collision situation while driving.
53. "Lane Departure Warning System" refers to a device that warns the operator when construction machinery deviates from the lane in which it is traveling, regardless of the operator's intention.
Article 3 (Ground Pressure of Tracked Construction Machinery)
① The ground pressure of tracked construction machinery is calculated according to the following formula
<img src="http://www.law.go.kr/flDownload.do?flSeq=34720670" alt="img34720670" >
┌──────────────────────────────┐
Ground pressure = Operating weight (kilogram)
│ ─────────────────────────│
Number of tracks × Shoe width (cm) × Ground contact length (cm)
└──────────────────────────────┘
</img>
② In Paragraph 1, "grounding length" refers to the sum of the distance between the centers of the tumblers and a length equivalent to 35/100 of the difference between the distance between the centers of the tumblers and the total track length (referring to the distance between the outermost edges of the track on the extension line of the distance between the centers of the tumblers; in this case, the grouser is deemed not to exist). <Amended May 27, 2013>
Article 4 (Bucket Volume)
① A bucket refers to a container for excavating or loading soil, etc. The capacity of a bucket is classified into flat load and bulk load, and the volume of a bucket shall be indicated as bulk load. <Amended May 27, 2013, July 31, 2020>
② In Paragraph 1, "level volume" refers to the level surface of the bucket or the volume of the part below the level surface, and shall be calculated according to the following formula.
Level = S1ㆍW1 (when x/y ≥ 12)
Level product = S1ㆍW1ㆍ(1-y/x) (for x/y < 12)
W1: Shortest distance between the inner sides of the two side plates of the bucket
S1: Cross-sectional area of the part below the planar surface on one side of the bucket (in the case where x/y < 12, this refers to the actual cross-sectional area of the bucket)
x: Length of flat line
y: Shortest distance from the planar surface to the lowest point of the planar surface
③ In Paragraph 2, "planar plane" refers to the surface inside the bucket among the planes containing the planar lines.
4. In Paragraph 2, "flat line" refers to a straight line connecting the center point of the upper surface of the bucket rear plate and the center point of the excavation blade, and "flat surface" refers to the part below the flat surface of a cylindrical shape in which the two endpoints of the flat line and the lowest point of the bucket side plate are defined as four points of the curved surface; examples thereof are as follows. <Amended 2020.7.31>
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865698" alt="img12865698" >
(Example)
Flat surface
Flat line
x
y
</img>
⑤ In Paragraph 1, "mountain stack" refers to the sum of flat volume and additionally stacked volume.
⑥ In Paragraph 5, "overstacking volume" refers to the volume of excavated material piled on top of the flat volume.
⑦ When calculating the volume of the piled-up material pursuant to Paragraph 6, the slope of the piled-up excavation [referring to the ratio of height to horizontal distance (height : horizontal distance)] shall be as follows: <Amended 2009.10.21>
1. In the case of shovel-type systems, a 1:2 inward slope from each upper corner of the flat surface
2. In the case of the White Tiger system, a 1:1 inward slope from each upper corner of the planar plane
Article 5 (Scope of Application)
① This Rule applies to construction machinery, and matters concerning the structure, specifications, performance, etc. of construction machinery not specified in this Rule shall be in accordance with the Korean Industrial Standards pursuant to Article 12 of the Industrial Standardization Act (hereinafter referred to as "Korean Industrial Standards"). <Amended Oct. 21, 2009>
② Notwithstanding Paragraph 1, the Minister of Land, Infrastructure and Transport may establish separate standards for construction machinery manufactured for special purposes or manufactured to ensure efficient performance in special locations. <Amended Mar. 14, 2008; Mar. 23, 2013>
Chapter 2 Working Devices of Construction Machinery
Section 1 Bulldozer
Article 6 (Dozer Plate and Excavation Angle)
① "Dozer blade" refers to a metal plate having a curved cross-section used by a bulldozer for excavating soil and aggregates, embankment, leveling, and backfilling operations. <Revised July 31, 2020, August 27, 2021>
② "Cutting blade" refers to a narrow, long metal plate mounted on the bottom of a dozer blade that makes line contact with the ground to prevent wear of the dozer blade. In this case, for a bulldozer not equipped with a cutting blade, the bottom of the dozer blade is considered the cutting blade.
[Title Revised 2020.7.31]
Article 7 (Angle Amount and Tilt Amount) "Angle Amount" refers to the angle formed by a straight line connecting the two symmetrical end points of the dozer blade with a plane perpendicular to the center plane of the bulldozer, and "Tilt Amount" refers to the vertical displacement when the left or right end of the dozer blade moves up or down relative to the ground, and examples thereof are as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865829" alt="img12865829" >
(example)
</img>
Article 8 (Climbing Ability and Braking System)
① Tracked bulldozers must be able to climb terrain with a slope of 30 degrees.
② Tracked bulldozers shall be equipped with braking systems and brake locking systems capable of maintaining a stationary state on ground with a slope of 30 degrees.
Article 9 (Angle and Tilt Amount Converting Devices, etc.)
① The angle and tilt amount conversion device of a bulldozer must be easy to operate.
② The dozer blade shall be free from severely deformed areas, such as cracks and bending. <Revised Aug. 27, 2021>
Article 9-2 (Rear Winch) When a rear winch is installed on the main body of a bulldozer, it shall comply with the standards of each of the following subparagraphs.
1. Be able to withstand twice the maximum rope traction force
2. Control devices shall be located within the cockpit
3. Install a steel mesh structure with a minimum radius of 6 millimeters and a maximum hole size of 45 millimeters × 45 millimeters, or a similar pilot protection device, between the cockpit and the winch. In this case, the size of the protection device shall be at least the size of the rear window if a cab is installed in the cockpit, and sufficient to protect the rear of the pilot if a cab is not installed in the cockpit.
[This Article Newly Established 2013.5.27]
Article 9-3 (Refurbishment)
① The ripper cylinder must be structured to enable smooth ripper operation.
② The ripper tooth must maintain sufficient strength to crush rock.
③ The ripper shank must be able to secure the tooth and must be firmly fixed to the vehicle body.
[This Article Newly Established 2013.5.27]
Section 2 Excavators <Revised 2020.7.31>
Article 10 (Climbing and Braking Capability) Excavators shall be equipped with braking devices and brake locking devices capable of climbing solid, dry ground with a slope of 25/100 (30/100 for tracked excavators) and maintaining a stationary state. <Amended May 27, 2013; June 1, 2018; July 31, 2020>
Article 11 Deleted <2020.7.31>
Article 12 (Dipper, etc. of Excavator) The dipper and clamshell bucket of an excavator shall be free from cracks or damage, and the dipper door shall open and close smoothly. <Amended July 31, 2020>
[Title Revised 2020.7.31]
Article 12-2 (Excavation Locking Device) The excavation locking device of an excavator shall be capable of preventing the movement of the vehicle body during excavation operations, and shall be structured to have the function of a locking device or brake capable of responding to excavation reaction forces; it may also serve as a driving braking device. <Amended July 31, 2020>
[This Article Newly Established 2013.5.27]
[Title Revised 2020.7.31]
Article 12-3 (Boom and Arm of Excavator)
① The boom of an excavator shall be installed at the front of the upper slewing body by a connecting pin to support the arm and bucket, etc., and shall be free of cracks, bends, and cuts so as to withstand impact during excavation. <Revised 2020.7.31, 2021.8.27>
② The excavator arm, which connects the bucket and the boom, must be able to withstand the impact during excavation. <Revised 2020.7.31>
[This Article Newly Established 2013.5.27]
[Title Revised 2020.7.31]
Article 12-4 (Left-right Stability) A wheeled excavator shall be constructed so as not to tip over when tilted up to 25 degrees to the left or right under its own weight on solid ground. In this case, the excavator shall be in the driving position. <Amended July 31, 2020>
[This Article Newly Established 2013.5.27]
Article 12-5 (Change in Bucket Inclination) When the engine is stopped while the excavator is in the maximum working radius state, the change in inclination of the bucket tip shall be within 5 degrees per 10 minutes. <Amended Jul. 31, 2020; Mar. 31, 2026>
[This Article Newly Established 2013.5.27]
Article 12-6 (Pilot Protection and Rescue)
① The operator's cab of an excavator equipped with a cab shall be an operator protection structure conforming to the standards of each of the following subparagraphs. <Amended 2020.7.31, 2026.3.31>
1. Excavators with an operating weight exceeding 1,500 kilograms shall be constructed to allow for the installation of guards to protect the operator from objects approaching from above or the front.
2. Excavators with an operating weight of 6,000 kilograms or less shall be equipped with a tipping protection structure to protect an operator wearing a seatbelt in the event of tipping over.
3. If a rollover protection structure is installed on an excavator, it shall comply with the test methods and standards for rollover protection structures
② The test methods and standards for structures pursuant to each subparagraph of Paragraph 1 are as set forth in Attached Table 2.
③ Manufacturers, etc. shall affix a label in a permanently legible location to provide information regarding the pilot protection structure.
[This Article Newly Established 2013.5.27]
Article 12-7 (Swinging Parking Brake)
① Excavators shall be equipped with a swing parking brake to ensure operational safety when swinging. <Revised 2020.7.31>
② The cornering parking brake shall automatically engage when the cornering operation is in the neutral position, and shall maintain its braking function whether the engine is running or stopped. <Revised 2026.3.31>
[This Article Newly Established 2013.5.27]
Article 12-8 (Center Joint) The center joint of an excavator shall be installed at the center of the rotating part and shall be structured to allow oil to be supplied to the upper and lower hydraulic devices even during rotation, and shall be structured to withstand loads and hydraulic pressure fluctuations occurring during excavation work. <Amended July 31, 2020>
[This Article Newly Established 2013.5.27]
Article 12-9 (Quick Coupler) When installing a quick coupler capable of rapidly engaging and disengaging an excavator bucket, it shall comply with the standards of each of the following subparagraphs. <Amended July 31, 2020>
1. The bucket lock shall be a double lock
2. Install a device that emits a warning sound loud enough for the pilot to know when the hydraulic lock is released.
3. It must be able to cut off the power when an overcurrent occurs in the quick coupler, and the operating switch shall be designed to be operated only by the pilot.
[This Article Newly Established 2013.5.27]
Section 3 Loader
Article 13 (Standard Load Condition of Loader, etc.)
① "Standard load condition of a loader" refers to a state in which soil of a specific gravity according to the Korean Industrial Standards is piled in the loader's bucket, the bucket is tilted to its innermost position, and the bottom of the bucket is raised to the loader's lowest ground clearance. <Revised 2009.10.21>
② "Standard no-load condition of the loader" refers to the state in which the unloaded bucket is tilted to its innermost position and the bottom of the bucket is raised to the loader's lowest ground clearance.
Article 14 Deleted <2026.3.31>
Article 15 (Stability)
① A wheeled loader shall not tip forward or backward when its centerline is parallel to the direction of inclination of the ground on ground surfaces corresponding to any of the following subparagraphs. <Amended 2018.6.1>
1. Ground with a slope of 15/100 when the loader is in its standard load condition
2. Ground with a slope of 30/100 in the loader's standard no-load condition
② A wheeled loader shall not tip over sideways when its centerline intersects the direction of the ground's inclination at a right angle on ground surfaces corresponding to any of the following subparagraphs. <Amended 2018.6.1>
1. On a ground with a slope of 20/100 when only the bucket is raised to the maximum under the loader's standard load condition
2. Ground with a slope of 60/100 in the loader's standard no-load condition
Article 16 (Braking Capability) A wheeled loader shall be able to maintain a stationary state on a flat, solid, and dry surface that meets the requirements of each of the following subparagraphs. <Amended June 1, 2018>
1. Ground with a slope of 15/100 when the loader is in its standard load condition
2. Ground with a slope of 20/100 in the loader's standard no-load condition
Article 17 (Bucket)
① The lifting, stopping, and reversing actions of the bucket must be performed accurately.
② The boom, arm, etc. connected to the bucket shall be free from cracks, bends, and cuts.
Article 17-2 (Fixing Device) A fixing device shall be installed to prevent the articulating part of the loader body from bending when parking or transporting the loader.
[This Article Newly Established 2013.5.27]
Article 17-3 (Hydraulic Piping) The hydraulic piping of the loader shall be able to withstand at least four times the operating pressure.
[This Article Newly Established 2013.5.27]
Article 17-4 (Cockpit, etc.)
① Loaders with a front-mounted door shall be equipped with a safety device to prevent the working device from moving when the operator enters or exits the cockpit.
② For loaders with a front door installed, the door dimensions must be at least 875 millimeters in height and 550 millimeters in width.
③ Loaders equipped with a front door must be structured to have an entrance in lieu of the door, and their dimensions must be at least 380 mm × 550 mm.
④ If there is a cab passageway between the loader body and the loader in a fully articulated steering state, the passageway must have a clearance of at least 150 millimeters.
[This Article Newly Established 2013.5.27]
Section 4 Forklift
Article 18 (Standard Load Conditions of Forklifts, etc.)
① "Standard load condition of a forklift" refers to a state in which the maximum load is evenly applied to the upper surface of the forklift's rake in a horizontal position with a height of 300 millimeters from the ground (referring to the state where the mast is tilted to its innermost position during driving).
② "Standard unloaded state of a forklift" refers to a state in which no load is applied to the upper surface of the forklift's rake in a horizontal position with a height of 300 millimeters from the ground (referring to the state where the mast is tilted to its innermost position during driving).
③ "Rake" refers to two or more horizontally protruding loading devices attached to the mast of a forklift by welding or a joining device.
Article 19 (Maximum Lifting Height and Maximum Load, etc.)
① "Maximum lifting height" refers to the height from the ground to the top surface of the rake when raised to its highest point while horizontal with the ground in the standard no-load state of the forklift, and in the case of a container handler, it refers to the height to the bottom of the rotary locking device.
② "Center of reference load" refers to the center of load when the maximum load is evenly applied to the upper surface of the forklift's rake.
③ "Maximum load" refers to the maximum load that can be loaded at the center of the standard load when the rake is raised to its maximum lifting height while ensuring the stability in accordance with Article 22.
④ "Maximum lifting capacity" refers to the maximum load that can be loaded at the center of the standard load when a rake is raised horizontally to a height of 3,000 millimeters from the ground (or the maximum height if the lifting height is 3,000 millimeters or less) under the forklift's standard load condition.
[Wholly Revised 2013.5.27]
Article 20 (Forward and backward tilt of the mast)
① "Mast forward tilt angle" refers to the inclination of the mast relative to the vertical plane when the forklift mast is tilted most towards the rake side in the standard no-load state.
② "Mast rear inclination" refers to the inclination of the mast relative to the vertical plane when the forklift mast is tilted most toward the cab under the standard no-load condition.
③ The forward and backward tilt angles of the mast shall comply with the standards set forth in the following subparagraphs. However, this shall not apply in cases where the structure is specially designed to lift steel plate coils or where safety alarm devices, etc., are installed to ensure safety is not compromised. <Amended 2009.10.21>
1. The forward tilt angle of a counterbalanced forklift shall be 6 degrees or less, and the backward tilt angle shall be 12 degrees or less.
2. The forward and backward tilt angles of a side-fork type forklift shall each be 5 degrees or less.
Article 21 (Amount of Change in Mast Inclination, etc.)
① When a forklift is loaded with a maximum load and the engine is stopped while the oil temperature of the hydraulic pump is 50 degrees Celsius, the change in inclination of the mast relative to the vertical plane shall be 5 degrees or less during the first 10 minutes after stopping (2.5 degrees during the first 5 minutes if the mast's forward tilt angle is 5 degrees or less). <Revised 2026.3.31>
② When the forklift is loaded with a maximum load and the engine is stopped while the oil temperature of the hydraulic pump is 50 degrees Celsius, the distance the rake descends due to its own weight and load shall be 100 millimeters or less per 10 minutes. <Revised Aug. 27, 2021, Mar. 31, 2026>
③ When a rake is lifted under the standard load condition of a forklift, the descent speed of the rake due to lowering operations or hydraulic system failure shall be 0.6 meters per second or less. <Newly added 2013.5.27>
④ When attaching a rapid descent prevention device to a rake, it must be attached to the cylinder. <Newly added 2013.5.27>
Article 22 (Stability)
① A forklift shall not tip forward or backward when its centerline is parallel to the direction of inclination of the ground on ground surfaces falling under any of the following subparagraphs. <Amended May 27, 2013, June 1, 2018>
1. Ground with a slope of 4/100 (3.5/100 if the maximum load of the forklift is 5 tons or more) when the rake is raised to its highest point under the forklift's maximum load condition
2. Ground with an incline of 18/100 when the forklift is driven under standard load conditions
② A forklift shall not tip over sideways when its centerline intersects the direction of inclination of the ground at a right angle on ground surfaces corresponding to any of the following subparagraphs. <Amended May 27, 2013, June 1, 2018>
1. On a ground with a slope of 6/100 when the forklift is in its maximum load state, with the rake raised to its highest height and the mast tilted to its furthest rear.
2. A surface where, when a forklift travels under standard no-load conditions, the gradient is a value obtained by multiplying the forklift's maximum driving speed by 1.1 and adding 15. However, this refers to a surface where the maximum gradient is 50/100 for specifications less than 5,000 kilograms, and 40/100 for specifications of 5,000 kilograms or more.
Article 23 (Braking Capability) A forklift shall be able to maintain a stationary state on a flat, solid, and dry surface that meets the requirements of each of the following subparagraphs. <Amended June 1, 2018>
1. Ground with a slope of 15/100 when the forklift is under standard load conditions
2. Ground with a slope of 20/100 in the standard no-load condition of the forklift
Article 24 (Minimum Breaking Load Ratio of Chain)
① The minimum breaking load ratio of a forklift mast chain is calculated by the following formula.
Minimum Breaking Load Ratio = (Minimum Breaking Load of Chain × Number of Chains) / (Maximum Load of Forklift + Weight of Lift Working Device Moved by Chain)
② The minimum breaking load ratio of a forklift mast chain must be 5 or greater.
Article 25 (Hydraulic Circuit Devices) Hoses, piping, and other connecting parts subject to the internal pressure of a forklift shall be able to withstand a pressure of at least three times the operating pressure that the hydraulic circuit can receive.
Article 26 (Reach Stacker Forklift)
① Reach-stacker forklifts must be equipped with an overload device, and the boom must be designed to operate solely through the operator's manipulation.
② The slide beam of the spreader must have smooth extension and retraction.
③ The twist lock must operate simultaneously and have a display device that the pilot can verify.
④ If a rotating device is installed, an optional fixing device must be additionally installed.
Article 26-2 (Telescopic Forklift)
① Telescopic forklifts must be equipped with an overload alarm device.
② The boom shall be able to withstand the maximum load and shall be free from cracks, bends, and breaks.
[This Article Newly Established 2013.5.27]
Article 26-3 (Electric Forklift)
① All operating devices for the driving of the electric forklift, the raising and lowering of the rake, tilting, and forklift operations shall be of a holding-in type that operates only while the operator is applying force.
② A verification label containing the details of each of the following subparagraphs must be attached to the battery installed in an electric forklift.
1. Name of battery manufacturer
2. Format
3. Serial Number
4. Rated Voltage
5. Amperes per hour (capacity) for 5 hours
6. Total battery weight (including case)
[This Article Newly Established 2013.5.27]
Article 26-4
[Formerly Article 26-4 moved to Article 133-2 <2020.7.31>]
Article 26-5 (Pilot Protection and Rescue)
① The spacing of upper protective structures for protecting the forklift operator shall be within 150 millimeters in width on at least one side.
② The deflection of the upper protective structure due to the cubic drop test shall be within 20 millimeters, and the minimum clearance required for the drop impact test shall be at least 250 millimeters from the handle to the bottom of the upper protective structure; the test loads and conditions are as specified in Attached Table 3.
[This Article Newly Established 2013.5.27]
[Moved from Article 26-4 <2018.6.1>]
Section 5 Scraper
Article 27 (Material of Bowl) The vertical movement of the scraper bowl shall be precisely proportional to the displacement of the control lever, and the interior of the bowl shall be manufactured of special steel with wear resistance and corrosion resistance.
Article 28 (Apron) The opening and closing of the scraper's apron and the forward and backward movements of the discharge device shall be performed smoothly.
Section 6 Dump Truck
Article 29 (Hydraulic Pump)
① The hydraulic pump shall be capable of withstanding a pressure of at least 1.5 times the operating pressure [the hydraulic pump for driving the cargo box required to lift the cargo box under maximum load capacity (hereinafter referred to as "hydraulic pump" in this Article)].
② The operating pressure of the hydraulic pump must be above the appropriate range.
Article 30 (Indication of Maximum Loading Weight) The maximum loading weight shall be indicated on the rear door of the cargo bed of a dump truck in a manner easily recognizable to the naked eye, in accordance with the standards of each of the following subparagraphs.
1. The maximum load capacity shall be indicated as follows, within a rectangle measuring at least 250 millimeters in width and 100 millimeters in height, with 10 digits or less filled with "00":
(Example): In the case where the maximum load capacity is 14,756 kilograms
<img src="http://www.law.go.kr/flDownload.do?flSeq=34720693" alt="img34720693" >
┌──────┐
Maximum Load Capacity
│14,700 kg │
└──────┘
</img>
2. The marking of the maximum load capacity shall not be easily erased or removed
Article 31 (Cargo box, etc. of dump truck)
① The cargo box shall be constructed of a material capable of sufficiently withstanding impact or uneven loading during loading, and thick ribs shall be attached to increase rigidity. However, ribs may be omitted if a material having a tensile strength of 60 kilograms per square millimeter or more is used. <Revised May 27, 2013>
② The raising, lowering, or stopping operations of the cargo box shall be smooth, and the cargo box shall not rise while the dump truck is in motion. <Amended May 27, 2013>
③ Dump trucks shall be equipped with a device capable of suppressing lateral swaying of the cargo box when it is lifted. <Amended May 27, 2013>
④ Dump trucks shall be equipped with a device that emits a warning sound so that the operator and surrounding people are notified when the cargo box is lifted or when it is being raised or lowered. <Amended 2009.10.21>
⑤ Dump trucks shall be equipped with a device to prevent the cargo box from lowering when the cargo box is raised for inspection or maintenance. <Newly added 2013.5.27>
⑥ The hinge of the rear door of the cargo compartment shall not protrude more than 200 millimeters from the top of the cargo compartment. <Revised May 27, 2013>
[Title Revised 2013.5.27]
Article 31-2 (Displacement of Inclination of Cargo Box) When the cargo box of a dump truck is lifted to 45 degrees on a flat surface (or the maximum lifted angle if the maximum lifted angle is less than 45 degrees) and the engine is stopped, the change in inclination of the cargo box relative to the ground shall be 1 degree or less over a period of 10 minutes. <Amended Mar. 31, 2026>
[This Article Newly Established 2013.5.27]
Article 31-3 (Stability) A dump truck shall not overturn even when tilted 30 degrees to the left or right on a flat surface while in its self-weight state.
[This Article Newly Established 2013.5.27]
Section 7 Cranes
Article 32 (Working Radius) "Working radius" refers to the shortest distance between a vertical line passing through the rotational center of the slewing device and a vertical line passing through the center of the hook.
Article 32-2 (Change in Boom Inclination, etc.)
① When a hydraulic crane is in a no-load state with the boom tilted to 45 degrees and the prime mover stopped, the change in boom tilt shall be within 2 degrees over a 10-minute period. <Revised 2026.3.31>
② The crane shall be constructed to prevent overloading when the maximum load that the crane can lift is exceeded within the working radius of the boom (including the jib).
[This Article Newly Established 2013.5.27]
Article 33 (Conductory Wire)
① The ground wires of crawler cranes shall be as follows:
1. When the vertical plane of the boom is perpendicular to the centerline of the crane, it refers to a straight line connecting points that are half the length of the lower track roller of the crawler located in front of the slewing device, and an example is as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865667" alt="img12865667" >
A
(Example)
A
</img>
2. When the vertical plane of the boom coincides with or is parallel to the centerline of the crane and the boom faces forward, it refers to the straight line connecting the centers of each idler wheel of the left and right crawlers, and an example is as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865669" alt="img12865669" >
(Example)
</img>
3. When the vertical plane of the boom coincides with or is parallel to the centerline of the crane and the boom faces the rear of the crane, it refers to the straight line connecting the centers of each drive wheel of the left and right crawler tracks.
② The ground wires for overturning a wheeled crane shall be as follows: <Amended 2009.10.21, 2013.5.27, 2026.3.31>
1. Where the vertical plane of the boom forms a right angle with the straight line connecting the centers of the foremost and rearmost wheels in the left or right direction of the crane (hereinafter referred to as the "front and rear wheel connecting line" in this Article), the tipping line refers to the front and rear wheel connecting line located in front of the slewing device, and an example thereof is as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865830" alt="img12865830" >
(example)
</img>
2. When the vertical plane of the boom coincides with or is parallel to the centerline of the crane and the boom faces the rear of the crane, it refers to the axis of the rearmost wheel, and an example is as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865831" alt="img12865831" >
(example)
</img>
3. When the crane is supported at three points on the ground, it refers to the side among the three sides of the triangle connecting each support point that forms a right angle with the vertical plane of the boom, and an example is as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865832" alt="img12865832" >
(example)
</img>
4. In cases where a crane falling under the provisions of Subparagraphs 1 through 3 uses outriggers (supports for preventing overturning), the outriggers shall be deemed wheels.
Article 34 (Rear Stability)
① "Rear stability" refers to the load distributed along the fore-and-aft axles under the conditions of each of the following subparagraphs in order to provide stability to the rear of the crane while avoiding the attachment of an excessive number of counterweights to the crane. <Amended Mar. 31, 2026>
1. It must be a flat and firm surface
2. Must be the minimum working radius
3. The lifting mechanism shall be in a state where no load is applied
4. There should be no outriggers
② For crawler cranes, the total load applied to the ground wires must be at least 15% of the crane's operating weight.
③ The rearward stability of a wheeled crane shall meet the standards of each of the following subparagraphs. <Amended May 27, 2013, Aug. 27, 2021>
1. Where the vertical plane of the boom is perpendicular to the crane's direction of travel, the sum of the loads applied to the wheels on the ground line shall be at least 15% of the crane's operating weight.
2. Where the vertical plane of the boom is the same as the crane's direction of travel, the sum of the loads applied to the wheels on the overturning ground line shall be greater than or equal to the value obtained by multiplying 15/100 of the crane's operating weight by the value obtained by dividing the average wheelbase by the axle distance.
Article 35 (Climbing and Braking Capability) Cranes shall be able to ascend a solid, dry surface with a slope of 25/100 (30/100 for crawler cranes) and maintain a stationary state. However, this shall not apply to cranes used in special locations, such as ports, as notified by the Minister of Land, Infrastructure and Transport. <Amended May 27, 2013, June 1, 2018>
Article 36 (Safety Factor of Crane Traveling Chain)
① The safety factor of a crane traveling chain is calculated by the following formula
<img src="http://www.law.go.kr/flDownload.do?flSeq=34720722" alt="img34720722" >
┌────────────────────────────┐
Safety factor of a driving chain = Chain breaking force × Chain transmission efficiency
│ ─────────────────│
Tension due to maximum torque of the prime mover
└────────────────────────────┘
</img>
Chain transmission efficiency: 1 (0.6 if the crane's travel method is a single-axis drive chain travel method)
② The safety factor of the crane traveling chain must be 2.5 or higher.
Article 37 (Braking Capacity of Ropes and Locking Devices) A crane shall be equipped with a braking capacity capable of maintaining a lifting state under a static load equivalent to 150% of the lifting capacity, and a locking device appropriate for maintaining said braking state.
Article 38 (Safety Factor, etc. of Wire Ropes)
① The safety factor of a wire rope refers to the value obtained by dividing the breaking load of the wire rope by the maximum load applied to the wire rope.
② Wire ropes shall have a safety factor in accordance with the following table. <Revised 2020.7.31, 2021.8.27>
<img src="http://www.law.go.kr/flDownload.do?flSeq=106925301" alt="img106925301" >
┌──────────────────────────────────────┬───┐
Types of Wire Ropes Safety Factor
├──────────────────────────────────────┼───┤
Kick-off (referring to the use of winding up a wire rope to lift objects) with wire 4.5
Wire rope for lifting and lowering of jibs (referring to the use of adjusting height, angle, etc.) and
Hostrope
├──────────────────────────────────────┼───┤
boom extension or support rope, wire rope for supporting a jib, auxiliary rope and for fixing 3.35
Earlobe
└──────────────────────────────────────┴───┘
</img>
[Wholly Revised 2013.5.27]
Article 38-2 (Winding of Wire Rope)
① In the case where the drum of a hoisting device (referring to a device that lifts objects by winding a wire rope) or the like has a groove, the fleet angle shall be within 4 degrees. <Revised Aug. 27, 2021>
② If the drum of a hoisting device, etc., does not have a groove, the pleat angle shall be within 2 degrees.
[This Article Newly Established 2013.5.27]
Article 38-3 (Connection of Wire Rope and Drum, etc.)
① The connection between the wire rope and the drum, jib, hook block, etc., shall be made by Babbitt metal fastening, socket fixing, clamp fixing, cotter fixing, eye-splice, and clip fixing.
② When using clip fastening, it must meet the standards in the following table. In this case, the spacing between clips shall be at least 6 times the diameter of the wire rope.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34720821" alt="img34720821" >
┌──────────┬────┐
Wire rope diameter (mm) Number of clips
├──────────┼────┤
16 or less 4 items
├──────────┼────┤
5 items greater than 16 and less than or equal to 28
├──────────┼────┤
More than 28 6 or more
└──────────┴────┘
</img>
[This Article Newly Established 2013.5.27]
Article 38-4 (Safety Valves, etc.)
① A safety valve must be installed in a hoisting device or lifting device (referring to a device that adjusts height and angle, etc.) using hydraulic pressure as a power source to prevent an excessive rise in hydraulic pressure. <Revised Aug. 27, 2021>
② The hoisting device or lifting device referred to in Paragraph 1 shall be equipped with a check valve to prevent the sudden descent of the lifting mechanism caused by an abnormal decrease in hydraulic pressure. However, this shall not apply if a braking device pursuant to Article 39-2 is installed.
[This Article Newly Established 2013.5.27]
Article 39 (Mounting Device)
① The lifting mechanism of the crane boom must be designed to safely maintain the boom and operate solely through the manipulation of the operator.
② Even when the crane is on a horizontal or inclined ground, the braking mechanism or other fixing device of the lifting device must have sufficient capacity.
③ Appropriate protective devices must be provided to prevent the rope from slipping out of the groove of the sheave of the lifting device. <Revised 2020.7.31>
Article 39-2 (Braking Devices for Lifting Devices, etc.) Lifting devices and hoisting devices shall be equipped with braking devices to prevent the sudden descent of the cargo or jib.
[This Article Newly Established 2013.5.27]
Article 40 (Alarm Device and Display Device)
① The following devices shall be installed on a crane in a location easily visible to the operator with the naked eye to ensure safe operation. <Amended Oct. 21, 2009, May 27, 2013>
1. Overload Alarm Device [Refers to a device that sends an alarm to the operator by visual and audible means when the load lifted by the crane at a given boom (including jib) length, working radius, and boom direction exceeds 87/100 of the maximum load the crane can lift]
2. Boom Inclination Angle Display Device
3. Load display device (referring to a device that displays the lifted load, and must be capable of displaying up to 120% of the maximum load that the crane can lift. However, in the case of an electronic load display device, it may display up to 100% of the maximum load)
② The rated load table of the crane shall be posted or kept in a place inside the operator's cabin or in a location easily visible from the operator's seat. <Newly added 2013.5.27, 2026.3.31>
Article 40-2 (Safety Devices) Cranes shall be equipped with the safety devices specified in each of the following subparagraphs. <Amended Aug. 27, 2021>
1. The hoisting device and the lifting device shall include an overwinding prevention device (referring to a wire rope excessive coiling prevention device) and an overwinding alarm device (referring to a wire rope excessive coiling notification device)
2. The hook shall have a release device to prevent wire ropes, etc. from coming off (excluding cases where a dedicated lifting device allows for load hanging without the assistance of a worker)
3. Rope anti-slip device for boom sheaves and hook blocks
4. Reverse rotation prevention device for hoisting drum
[This Article Newly Established 2013.5.27]
Article 41 (Crane Differs, etc.) The crane dippers and clamshell buckets shall be free from cracks or damage, and the dipper doors shall open and close smoothly.
Article 41-2 (Swinging Parking Brake)
① The crane shall be equipped with a swing parking brake to ensure operational safety during slewing.
② The slewing parking brake shall be capable of operating automatically or manually even when the prime mover is running or stopped. <Revised 2026.3.31>
[This Article Newly Established 2013.5.27]
Article 41-3 (Center Joint of Cranes) The center joint of a hydraulic crane shall be installed at the center of the rotating part and shall be structured to allow oil to be supplied to the upper and lower hydraulic equipment even during slewing, and shall be structured to withstand loads and fluctuations in hydraulic pressure occurring during operation.
[This Article Newly Established 2013.5.27]
Section 8 Motor Grader
Article 42 (Tandem Device)
① A motor grader shall be equipped with a tandem device to enable horizontal operation of the blade even when moving up and down or left and right on uneven surfaces. <Revised May 27, 2013>
② The safety factor of the travel chain of a motor grader tandem device shall be 2.5 or higher. <Newly added 2013.5.27>
Article 43 (Leaning Device) A motor grader shall be equipped with a leaning device to reduce the turning radius.
Article 44 (Scare) The scaree of a motor grader shall be structured to allow the number of teeth to be changed according to the condition of the working ground.
Article 44-2 (Blade) The blade of a motor grader shall be capable of adjusting the working angle through vertical, horizontal, and swivel movements, and shall be equipped with an angle-fixing locking device.
[This Article Newly Established 2013.5.27]
Section 9 Roller
Article 45 (Sprinkler Device)
① A removal device or a spraying device shall be installed on the roller to prevent materials or foreign substances from adhering to the surface of the roller. <Amended May 27, 2013>
② Among the devices referred to in Paragraph 1, the sprinkler system shall be of the mechanical or electric nozzle spray type. <Amended May 27, 2013>
Article 46 (Vibration Devices, etc.)
① The tire vibration device of a tire-type roller must be easily lockable from the cockpit.
② In the case of a tire-type roller with a double-row tire arrangement, the tires must be arranged so that the rear wheels compact the areas not compacted by the front wheels.
③ For vibrating rollers, anti-vibration rubber must be attached between the axle and the vehicle body, or if tires are used, pneumatic tires must be used.
④ The rolls of rollers (excluding tire-type rollers) shall be made of cast steel or a welded steel plate structure.
⑤ The projection of the roller shall be made of steel plate, cast steel, or steel rod, etc., and the tip contact portion of the projection shall be made of wear-resistant steel.
⑥ Ballast refers to materials and weights intended to increase the compaction pressure of the roller, and its installation must be robust. <Newly added 2013.5.27>
Section 10 Road Stabilizer
Article 47 (Heating Device, Rotor and Hood)
① A heating device using a burner or the like must be installed in the road stabilizer to insulate the asphalt, etc., inside the emulsion tank.
② A rotor equipped with a cutter to excavate the ground or mix paving materials must be installed on the road stabilizer. <Revised Aug. 27, 2021>
③ A hood covering the rotor must be installed during the road stabilizer to prevent material diffusion and to improve mixing and laying efficiency.
Article 48 (Work Capacity) Road stabilizers must be capable of crushing or mixing soil while advancing on the road, and must be structured to enable emulsion spraying operations.
Section 11 Concrete Batching Plant
Article 49 (Specifications of Drums, etc.)
① The drum of the concrete batching plant must be supported by a sturdy fixing device, and the drum must be easy to replace.
② The blades inside the drum of the concrete batching plant shall be made of wear-resistant steel.
Article 50 (Weighing Devices)
① A concrete batching plant shall be equipped with a weighing device consisting of containers necessary for weighing materials to be mixed, scales, and instruments necessary for operation.
② The weighing device shall be equipped with an aggregate weighing device, a paving filler weighing device, and a cement weighing device (hereinafter referred to as "weighing device" in this Section), and the weighing device shall be equipped with the functions of each of the following subparagraphs.
1. Function to measure and display the weight of materials when feeding them into the mixing device
2. Function to accumulate and display the weight of materials when feeding them into the mixing device
③ The gate of the meter must be designed to open manually or automatically, and to close automatically when the supplied material reaches the target amount.
Article 51 (Mixing Selector) A concrete batching plant shall be equipped with a mixing selector that allows for the pre-setting of various mixing ratios for materials and, if necessary, enables the selection of a mixing ratio to mix the materials accordingly.
Article 52 (Precision Storage Device) A concrete batching plant shall be installed with a precision storage device that increases the precision of weighing by lowering the opening degree of the weighing gate when 90% of the predetermined material supply amount is supplied to the mixing device.
Article 53 (Capacity Changing Device) A concrete batching plant shall be equipped with a capacity changing device capable of changing only the capacity without changing the mixing ratio of the materials.
Article 54 (Material Storage Containers, etc.)
① The material storage tanks of the concrete batching plant should be installed at the top if possible and must be structured to allow for storage separated by material type.
② The material supply device of the concrete batching plant must be capable of coordinated operation with the metering device.
③ The control panel of the concrete batching plant shall display the operating status of the meter, the operating status of the cold feeder, the power distribution status, and the weight of the materials, etc.
Section 12 Concrete Finisher
Article 55 (Screw Spreader, etc.)
① A screw spreader for laying fresh concrete shall be installed on the concrete finisher. <Revised 2009.10.21>
② A primary screed shall be installed on the concrete finisher to ensure that the thickness of the fresh concrete laid by the screw spreader becomes uniform.
③ A finishing screed (secondary screed) for smoothing the surface of fresh concrete remaining after the primary screed work must be installed on the concrete finisher.
Article 56 (Vibrator) A concrete finisher shall be equipped with a vibrator that applies strong vibration and pressure to the surface of the laid fresh concrete for compaction.
Article 57 (Concrete Injection Width) A concrete finisher shall be structured to allow for the adjustment of the concrete injection width.
Section 13 Concrete Spreader
Article 58 (Types of Concrete Spreaders) Concrete spreaders shall be classified as follows:
1. Screw conveyor type concrete spreader: A concrete spreader that uniformly lays fresh concrete on the subgrade using a screw conveyor
2. Blade-type concrete spreader: A concrete spreader that lays fresh concrete by having blades, which rotate and move up and down by hydraulic pressure, move left and right along a frame.
Section 14 Concrete Mixer Truck
Article 59 (Drum Driving Method)
① "Hydraulic drive system" refers to a method of obtaining rotational driving force for a concrete mixer truck drum through the following hydraulic device.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865833" alt="img12865833" >
</img>
② "Mechanical drive method" refers to a method of obtaining the rotational driving force of a concrete mixer truck drum by means of the following mechanical device
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865834" alt="img12865834" >
</img>
Article 60 (Specifications of Drum, etc.)
① The concrete mixer truck drum must be supported by a sturdy fixing device, and the drum must be easy to replace.
② The blades inside the concrete mixer truck drum shall be made of wear-resistant steel.
③ The drum rotation speed of a concrete mixer truck according to the type of operation shall meet the standards of each of the following subparagraphs.
1. For mixing operations: 6 revolutions per minute or more
2. For stirring operations: 2 revolutions per minute or more
④ The drum rotation speed of a gravity-type concrete mixer truck shall be within an appropriate range that does not impede the maintenance of its function.
⑤ Where the drum is driven by a sprocket or chain, a safety cover must be installed on the chain. <Newly added 2013.5.27>
⑥ The rotational direction and speed of the concrete mixer truck drum shall be controllable using control levers, etc., installed in the control cabin and on the exterior. <Newly added 2013.5.27>
⑦ The support shafts and support bearings of the concrete mixer truck drum shall be free from cracks and deformation, and the drum's rotation shall be maintained smoothly. <Newly added 2013.5.27>
⑧ Concrete mixer trucks shall be equipped with a device capable of preventing the drum from detaching while driving. <Newly added 2013.5.27>
Article 61 (Delivery Device)
① A device capable of collecting waste concrete and wastewater shall be installed at the bottom of the delivery device of a concrete mixer truck, and an inlet device that ensures smooth operation shall be attached to said device. <Amended 2009.10.21, 2013.5.27>
② The delivery device shall be structured to operate smoothly up, down, left, and right when delivering concrete, and to be fixed while in motion. <Newly added 2013.5.27>
③ The delivery device shall not exhibit severe vibration or unusual noise during operation. <Newly added 2013.5.27>
Article 62 (Stability) A concrete mixer truck shall not overturn while tilted 20 degrees to the left or right on a flat surface under its own weight.
[Wholly Revised 2013.5.27]
Section 15 Concrete Pump
Article 63 (Boom and Hopper of Concrete Pump)
① The boom of the concrete pump shall be capable of 360-degree slewing.
② The boom and the cab must be constructed so that they do not come into contact when the boom slew, or a contact prevention device must be installed. <Newly added 2013.5.27>
③ When the prime mover is stopped at the concrete pump's maximum working radius, the change in inclination of the outermost boom tip shall be within 2.5 degrees per 10 minutes. <Newly added 2013.5.27, 2026.3.31>
④ The stirring device inside the hopper of the concrete pump shall be structured to enable periodic forward and reverse rotation. <Revised May 27, 2013>
Article 63-2 (Delivery Devices, etc.)
① The delivery device shall be free from severe vibration or unusual noise during operation and shall maintain sufficient pressure for delivery.
② The conveying rollers of a squeeze-type concrete pump must have sufficient durability.
③ The structure shall ensure that the outriggers operate only by operator manipulation during the discharge operation of the concrete pump.
[This Article Newly Established 2013.5.27]
Article 64 (Pressure Gauge)
① The discharge pressure of a concrete pump refers to the pressure per unit area of concrete discharged from the pump's discharge port, and a pressure gauge capable of displaying the discharge pressure shall be installed on the concrete pump body. <Revised May 27, 2013>
② The pressure gauge in Paragraph 1 shall be capable of displaying up to 130 percent of the discharge pressure of the relevant concrete pump.
Article 65 (Discharge Volume) The discharge volume of a concrete pump refers to the volume of concrete discharged per unit time (㎥/h) from the discharge port.
[Wholly Revised 2013.5.27]
Section 16 Asphalt Mixing Plant
Article 66 (Weighing Device) An asphalt mixing plant shall be equipped with a weighing device consisting of containers necessary for weighing materials to be mixed, scales, and instruments necessary for operation. However, an asphalt mixing plant using already mixed materials may be exempt from installing a weighing device. <Amended Mar. 31, 2026>
Article 67 (Drying and Heating Device) An asphalt mixing plant shall be installed with a drying and heating device that heats and dries materials to a constant temperature.
Article 68 (Dust Collector) An asphalt mixing plant shall be equipped with a dust collector for recovering discharged dust, etc.
Article 69 (Kettle) An asphalt mixing plant shall be equipped with a kettle, which is a container for melting bitumen. However, in the case of an asphalt mixing plant using pre-mixed materials, a kettle may not be installed. <Amended Mar. 31, 2026>
Article 70 (Feeders, etc. of Aggregate Supply Devices)
① The feeder of the material supply device of the asphalt mixing plant must be able to adjust the aggregate supply amount.
② Liners shall be installed on the inner surface of the mixing device of an asphalt mixing plant to prevent wear and to provide thermal insulation. However, liners may not be installed in the case of a mixing device manufactured of a special material that exhibits minimal wear on aggregates, etc., and where thermal insulation measures are secured. <Amended Mar. 31, 2026>
③ The piping of the asphalt supply device of an asphalt mixing plant shall use insulated pipes or double piping through which steam or heated oil passes.
Section 17 Asphalt Finisher
Article 71 (Spreader, etc.) An asphalt finisher shall be equipped with a spreader for evenly spreading asphalt on the road surface and a device capable of adjusting the paving thickness. <Amended May 27, 2013>
[Title Revised 2013.5.27]
Article 72 (Temper) An asphalt finisher shall be equipped with a tamper that presses and compacts the asphalt spread on the road surface by a spreader to a uniform state of compaction.
Article 73 (Screed)
① An asphalt finisher must be equipped with a screed to ensure that the thickness of the asphalt compacted by a tamper becomes uniform.
② Heating devices, such as burners, must be installed on the screed to prevent asphalt from adhering to the screed.
Article 74 (Hopper) The hopper of an asphalt finisher shall be made as low as possible, taking into consideration the height of the dump truck's cargo bed.
[Title Revised 2013.5.27]
Section 18 Asphalt Spreader
Article 75 (Heating Device) An asphalt spreader shall be equipped with a heating device (referring to a device that prevents the asphalt inside a storage tank from hardening by melting or heating the stored asphalt with a burner and insulating the circulation pipe using the exhaust gas generated at this time).
Article 76 (Nozzle) A nozzle [referring to a device attached to a spray bar (including an extended spray bar) for spraying asphalt] shall be equipped with a valve capable of controlling the spray volume.
Article 77 (Capacity Display Device)
① A capacity display device indicating the maximum amount of asphalt that can be stored and the amount of stored asphalt shall be attached to the exterior of the asphalt tank of the asphalt spreader.
② The capacity display device referred to in Paragraph 1 shall display the capacity in units of liters.
Article 78 (Material of Asphalt Tanks, etc.)
① The asphalt tank of an asphalt spreader must be constructed as a double tank using insulation material with low thermal conductivity.
② The asphalt tank of an asphalt spreader shall be equipped with baffles to prevent the asphalt from sloshing during operation, and the tank shall possess sufficient strength. <Revised May 27, 2013>
③ The spray bar must be adjustable up, down, left, and right.
Section 19 Crusher
Article 79 (Types and Structure of Stone Crushers) The standards for the types and structures of stone crushers are as follows: <Amended May 27, 2013>
1. Rough Crusher: A crusher that breaks raw stones placed between a fixed plate and a movable plate by the compressive force of the movable plate reciprocating toward the fixed plate by power; the fixed plate and the movable plate shall have sufficient strength against the compressive force.
2. Roll Crusher: A crusher that breaks raw stones passing between two rolls rotating in opposite directions by the compressive force; the rolls, bearings, and roll shafts shall have sufficient strength against the compressive force.
3. Gyratory Crusher: A crusher that forms a crushing chamber by mounting a conical head on a main shaft inside a fixed conical container, and crushes raw stones as the conical head performs an eccentric rotational motion driven by the rotation of an eccentric shaft installed at the bottom; the mantle must allow for smooth eccentric rotational motion and possess sufficient strength against compressive force using a wear-resistant material.
4. Cone Crusher: A crusher similar in structure to a gyratory crusher that breaks raw stones through high-speed rotation; the mantle shall possess sufficient strength against high-speed rotation and impact.
5. Impact Crusher: A crusher that breaks raw stones by the high-speed rotation of a rotor equipped with a striking plate; the striking plate and rotor shall have sufficient strength against compressive force.
6. Mill Crusher: A crusher that breaks raw stone by rotating multiple steel rods or balls inside a cylindrical drum; the steel rods or balls inside the drum shall have sufficient strength to crush the raw stone.
[Title Revised 2013.5.27]
Article 79-2 (Standard Production Capacity) The standard production capacity of a crusher refers to the maximum amount of aggregate (t/h) that can be produced per unit time when the size of the discharge port is fixed to the standard state specified by the manufacturer, etc.
[This Article Newly Established 2013.5.27]
Delete Article 80 <2020.7.31>
Article 81 (Feeder) A crusher shall be equipped with a feeder that continuously supplies raw stone to the crusher's hopper, and shall be equipped with a material and structure suitable for transporting raw stone. <Amended May 27, 2013>
Section 20 Air Compressor
Article 82 (Discharge Pressure, etc.) An air compressor shall be capable of maintaining a prescribed discharge pressure (referring to the pressure of compressed air discharged from the discharge port of the air compressor) for a sufficient period of time, and at least two safety valves and unloader valves shall be installed with a structure capable of operating independently, and shall be adjusted to ensure accurate operation. <Amended May 27, 2013>
Article 82-2 (Types and Structures of Compression Methods)
① Vane-type air compressors must have rotors and vanes with sufficient strength to produce air at the specified discharge pressure.
② Screw-type air compressors must have screws with sufficient strength to produce air at the specified discharge pressure.
③ Piston-type air compressors must have pistons, liners, and connecting rods that possess sufficient strength to produce air at the specified discharge pressure.
[This Article Newly Established 2013.5.27]
Article 83 (Silencers, etc.)
① An air compressor shall be equipped with a silencer to reduce noise generated when inhaling and discharging air. However, a silencer may not be installed if it complies with the noise management standards for noise-generating construction machinery pursuant to Article 44 of the Noise and Vibration Control Act. <Amended Mar. 31, 2026>
② The air compressor shall be equipped with a device that displays the pressure inside the air tank.
③ The air tank of an air compressor shall be constructed to withstand at least 1.3 times the specified pressure. <Newly added 2013.5.27>
Article 83-2 (Automatic Stop Device) An air compressor shall be constructed such that the prime mover automatically stops in any of the following cases as specified by the manufacturer, etc.
1. If engine oil or coolant temperature exceeds the specified value
2. If the internal air tank temperature or oil temperature exceeds the specified value
[This Article Newly Established 2013.5.27]
Section 21 Drilling Machine
Article 84 (Indication of Air Consumption, etc.)
① The vehicle body of the drilling rig shall indicate the amount of air consumed by the drilling rig per unit time and the required air pressure under atmospheric pressure. <Revised May 27, 2013>
② Compressed air shall be supplied to enable drilling operations. <Newly added 2013.5.27>
[Title Revised 2013.5.27]
Article 85 (Drifter Support Boom) The drifter support boom of a tracked drilling rig shall be of a structure capable of moving up and down or left and right by means of a hydraulic device. <Amended Oct. 21, 2009>
Article 86 (Drive Wheel Drive Motor) The motors driving the drive wheels of a tracked drilling rig shall be two in number and shall be structured to enable independent driving of the left and right wheels, respectively. <Amended Oct. 21, 2009>
Article 87 (Rock Drills, etc.)
① Jumbo-type drilling rigs shall be structured to allow the drilling position of the rock drill to be easily adjusted vertically or horizontally. <Revised May 27, 2013>
② The boom supporting the rock drill shall be free of cracks, bends, and cuts to withstand vibrations during drilling. <Newly added 2013.5.27>
③ The rod of the rock drill must be manufactured of a material with sufficient durability. <Newly added 2013.5.27>
④ In the case of hydraulic types, pressure and flow rate must be maintained to enable drilling operations. <Newly added 2013.5.27>
[Title Revised 2013.5.27]
Article 87-2 (Cutters, etc.)
① The cutter installed on the front of a tunnel boring machine or a shield boring machine must be able to maintain sufficient strength to excavate raw stone or sand, and must be structured to move the crushed raw stone or sand.
② Tunnel boring machines and shield boring machines shall display the working status of the cutter, main body, and frame in real time.
[This Article Newly Established 2013.5.27]
Section 22 Pile Driving and Pile Extraction Machines
Article 88 (Diesel Pile Hammer Type Pile Driver and Pile Extractor)
① The types of diesel pile hammer type pile drivers and pile extractors are as follows:
1. Single-acting type with a combustion chamber installed on only one side of the striking body
2. A semi-double-acting cylinder with a closed design, where the lower part is the combustion chamber and the upper part is the air reaction chamber, striking by the reaction of air
② The cooling method of the diesel pile hammer type pile driver and pile extractor is as follows:
1. Water-cooled type that cools the cylinder using water
2. Air-cooled type that cools the cylinder using air
③ The number of blows for diesel pile hammer type pile drivers and extractors shall be at least 40 per minute, and the maximum and minimum values of the number of blows shall be marked on the vehicle body.
Article 89 (Vibrating Pile Hammer Type Driving and Pile Extracting Machines) The vibration frequency of the vibrator of a vibrating pile hammer type driving and pile extracting machine shall be at least 500 times per minute.
Article 89-2 (Auger Devices, etc.)
① The auger screw must be able to withstand twisting and impact during excavation, and must be structured to allow excavated soil to be easily discharged by the screw.
② The leader shall be free from damage such as cracks or deformation, and the rear support of the leader (referring to the backstay, etc.) shall operate smoothly.
③ The tilt indicators on the reader and the main body shall be installed in a location easily visible to the pilot.
[This Article Newly Established 2013.5.27]
Section 23 Gravel Extractors <Revised 2018.6.1>
Article 90 (Bucket of Gravel Sweeper) The bottom surface and teeth of a gravel sweeper bucket shall be made of wear-resistant steel and shall be of a structure that allows for easy maintenance or replacement. <Amended June 1, 2018>
[Title Revised 2018.6.1]
Article 91 (Lifebuoys, etc. for Gravel Sweepers) Gravel sweepers shall be equipped with the following: <Amended May 27, 2013, June 1, 2018>
1. Two or more lifebuoys
2. 4 or more lifebuoys
3. 4 or more fire extinguishers
4. Flame life-saving equipment for rescue in emergencies
5. Location indicator light for life-saving equipment
[Title Revised 2018.6.1]
Article 92 (Sorting Devices and Conveyors)
① A gravel excavator shall be equipped with a sorting device capable of sorting aggregates by size. <Amended 2018.6.1>
② A conveyor for transporting aggregates produced from a sorting device shall be installed on the gravel excavator, and the conveyor shall be made of a material suitable for transporting aggregates. <Amended May 27, 2013, June 1, 2018>
Article 92-2 (Fuel Tank) The fuel oil tank of a floating gravel dredger shall be equipped with an air pipe pursuant to Article 26 of the Ship Safety Act and a depth sounding device capable of measuring the flow rate. <Amended June 1, 2018>
[This Article Newly Established 2013.5.27]
Section 24 Dredgers
Article 93 (Cutter) A cutter (referring to a device installed on a pump-type dredger that excavates soil while rotating underwater) shall be manufactured of wear-resistant steel.
Article 93-2 (Suction Pipe) A foreign matter removal device (referring to a stone removal pipe, etc.) for removing foreign substances such as stones shall be installed in the suction pipe of a dredging pump, and a reverse flow prevention valve shall be installed in the discharge pipe.
[This Article Newly Established 2013.5.27]
Article 93-3 (Spuds) Spuds shall be posts of sufficient wear resistance, free from cracks, bends, and cuts, and their embedment depth shall be within four times their diameter.
[This Article Newly Established 2013.5.27]
Article 93-4 (Grave and Hoist) The fall impact of the grave shall not reach the boom, and the hoist shall be able to free fall from the set position and brake automatically.
[This Article Newly Established 2013.5.27]
Article 93-5 (Fuel Oil Tanks) Fuel oil tanks shall be equipped with an air pipe pursuant to Article 26 of the Ship Safety Act and a sounding device capable of measuring the flow rate.
[This Article Newly Established 2013.5.27]
Article 94 (Lifebuoys, etc. of Dredgers)
① A dredger shall be equipped with the following: <Amended May 27, 2013>
1. Two or more lifebuoys
2. 4 or more lifebuoys
3. 4 or more fire extinguishers
4. Flame-saving equipment for rescue in emergencies
5. Location indicator light for life-saving equipment
② Dredgers shall be equipped with facilities capable of purifying and discharging sewage and wastewater generated from the hull, or with storage tanks capable of collecting sewage and wastewater and transporting it overboard for treatment. <Amended May 27, 2013>
Section 24-2 Special Construction Machinery <Newly Inserted 2012.5.7>
Article 94-2 (Truck Forklifts)
① A truck forklift (referring to a truck forklift that is a special construction machine designated by the Minister of Land, Infrastructure and Transport pursuant to Item 26 of Annex 1 of the Enforcement Decree of the Construction Machinery Management Act) shall have a traveling chassis with a driver's seat and a lifting device including a separate cockpit (hereinafter referred to as "working device" in this Article). <Amended Mar. 23, 2013>
② The provisions of Articles 18 through 25 shall apply mutatis mutandis to the safety standards for working devices of truck forklifts. In this case, the stability under Article 22 shall be based on the maximum driving speed when operating the working device.
③ The cockpit of the working device and the driver's seat of the traveling chassis must be structured so that pedals for the steering, acceleration, and braking systems of the same function cannot be operated simultaneously.
④ The structure must be such that starting is impossible from the driver's seat of the moving chassis unless the rake of the working device is folded or removed.
⑤ The maximum lifting capacity and empty weight shall be indicated on the left and right sides of the truck forklift, respectively.
[This Article Newly Established 2012.5.7]
Section 25 Tower Crane
Article 95 (Types of Tower Cranes) The types of tower cranes are as follows:
1. "Fixed tower crane" refers to a tower crane installed on a concrete foundation or a fixed foundation.
2. "Rising tower crane" refers to a tower crane installed above a structure under construction that can be raised vertically by its own lifting device as the height of the structure increases.
3. "Traveling tower crane" refers to a tower crane that operates by installing rails on the ground or a structure, allowing the crane itself to move along the rails and stop while performing work.
Article 96 (Rated Load, etc. of Tower Cranes)
① "Rated load of a tower crane" refers to the load obtained by subtracting the load of lifting devices, such as hooks, grabs, or buckets, from the lifting load of the tower crane.
② "Hoisting load" refers to the maximum load that a tower crane can lift according to the length and angle of inclination of the jib.
③ "Traveling" refers to a traveling tower crane moving along rails.
④ "Traversing" refers to the movement of a trolley and lifting equipment along a jib. <Revised 2020.7.31>
⑤ "Self-supporting height" refers to the height from the lowest point of a tower crane mast to the highest point of a mast installed without auxiliary means of support or fixation.
Article 97 (Stability)
① The stability of a tower crane at the point of overturning shall comply with the tower crane stability requirements of the Korean Industrial Standard (KS). <Revised Jan. 30, 2013>
② The stability under Paragraph 1 shall be calculated under the following conditions. <Amended Jan. 30, 2013>
1. The load affecting stability shall be the most adverse condition regarding the stability of the tower crane
2. The wind will blow from the direction most unfavorable to the stability of the tower crane
③ Traveling tower cranes shall be equipped with a fixing device capable of preventing movement caused by external forces, such as wind loads, when stationary. However, this shall not apply to tower cranes installed indoors that are not directly subject to wind loads. <Amended Jan. 30, 2013>
Article 98 (Braking Device of Tower Crane)
① Traveling tower cranes shall be equipped with a braking device for braking travel. In this case, the braking torque value for braking travel shall be at least 50/100 of the motor's rated torque.
② Tower cranes shall be equipped with a braking device for braking traversal.
③ Tower cranes shall be equipped with a braking device to brake the rotation of the slewing section.
Article 99 (Braking Devices for Hoisting Devices, etc.)
① Hoisting devices and lifting/lowering devices shall be equipped with a braking device to brake the lowering of the load or jib. However, this shall not apply to hoisting devices and lifting/lowering devices using hydraulic cylinders, pneumatic cylinders, or steam cylinders.
② The braking device referred to in Paragraph 1 shall meet the standards of each of the following subparagraphs. <Amended 2013.1.30>
1. The braking torque value (referring to the sum of the braking torque values of each brake when two or more brakes are installed on the hoisting or lifting device) shall be at least 1.5 times the torque value of the hoisting or lifting device of the tower crane (referring to the maximum value among two or more such torque values) when the tower crane lifts a load equivalent to the rated load.
2. The tower crane shall be equipped with a braking device capable of maintaining the lifted state when lifting the rated load.
3. Operate automatically when the tower crane's power is removed or cut off
4. Heavy objects shall not fall even in the event of a power supply problem
③ The torque value of the hoisting device or lifting device referred to in Paragraph 2, Subparagraph 1 shall be calculated as having no resistance. However, if a worm and worm gear mechanism with an efficiency of 75/100 or less is used in the said hoisting device or lifting device, the torque value shall be calculated as having resistance equivalent to half of the torque value generated by the resistance of said gear mechanism.
Article 100 (Diameter of Wire Rope)
① The ratio of the drum pitch circle diameter of a device that operates, such as hoisting, traveling, and traversing by means of a wire rope (hereinafter referred to as "hoisting device, etc." in this Section) to the diameter of the wire rope wound around the drum, and the ratio of the sheave pitch circle diameter of the hoisting device, etc. to the diameter of the wire rope passing through the sheave, shall meet the standards of the following table. However, the ratio of the equalizer sheave pitch circle diameter of the hoisting device, etc. to the diameter of the wire rope passing through the equalizer sheave shall be 10 or more, and the ratio of the sheave pitch circle diameter for an overload protection device to the diameter of the wire rope passing through the sheave shall be 5 or more. <Revised 2013.1.30>
<img src="http://www.law.go.kr/flDownload.do?flSeq=34721129" alt="img34721129" >
┌───────────────────┬──────────────────┐
Wire Rope Configuration Drum Pitch Circle Diameter/Wire Rope Diameter or
Sheave Pitch One Diameter/Wire Rope Diameter
├───────────────────┼──────────────────┤
19 Main Line 6-Twist Wire Rope 25 or more
│ │ │
24-Main Line 6-Twist Wire Rope 20 or more
│ │ │
37 Main Line 6-Twisted Wire Rope 16 or more
│ │ │
Pillar type 25 strands 6-twist wire rope 20 or more
│ │ │
Pillar type 29 strands 6-twist wire rope 16 or more
│ │ │
Warrington Seal Type 26 Main Line 6-Twist Wire Rope 16 or More
│ │ │
Warrington Seal Type 31 Main Line 6-Twist Wire Rope 16 or More
└───────────────────┴──────────────────┘
</img>
② The drum of the hoisting device, etc., must be large enough to wind the entire length of the rope in a single layer. However, if winding in a single layer is impossible due to constraints on installation space, etc., it may be wound in multiple layers. <Newly added 2013.1.30>
③ In cases where multi-layer winding is performed pursuant to the proviso of Paragraph 2, the rope must be accurately wound onto the drum of the hoisting device, etc. at any position, and a rope guide, etc., may be used if necessary for this purpose. <Newly added 2013.1.30>
④ The grooves of the drums of hoisting devices, etc., shall meet the standards of each of the following subparagraphs. <Newly added 2013.1.30, 2021.8.27>
1. The radius of the groove shall be in the range of 0.525 to 0.65 times the nominal diameter of the rope. In this case, the selection must be made considering the tolerance of the rope diameter.
2. The depth of the groove shall be in the range of 0.25 to 0.4 times the nominal diameter of the rope
3. The pitch of the groove shall be in the range of 1.04 to 1.15 times the nominal diameter of the rope for a single layer winding
4. The groove must be free of surface defects that could damage the rope, and the corners must be rounded.
⑤ The winding amount of wire rope wound on the drum of a hoisting device, etc., shall meet the standards of each of the following subparagraphs. <Newly added 2013.1.30>
1. When the hook is positioned at its lowest point, there must be at least 2 wraps of rope remaining on the drum that is not secured to the clamp.
2. When the hook is positioned at the highest point, there shall be at least one wrap of slack in the corresponding layer.
⑥ The drum of a hoisting device, etc., shall be equipped with a flange, a rope guide with a limiting device attached, and other limiting equipment to prevent the rope from detaching from the end of the drum and getting caught. <Newly added 2013.1.30>
⑦ Flanges and restraining equipment shall be of a flat shape, and the measurement height shall be at least 1.5 times the diameter of the outermost coiled layer rope. <Newly added 2013.1.30>
Article 101 (Winding of Wire Rope)
① If the drum of a hoisting device, etc., has a groove, the fleet angle must be within 4 degrees.
② If the drum of a hoisting device, etc., does not have a groove, the pleat angle shall be within 2 degrees.
③ When winding a wire rope in multiple layers onto a drum of a hoisting device, etc., the pleat angle at the flange section shall be within 4 degrees to ensure uniform winding of the rope. <Newly added 2013.1.30>
Article 102 (Connection of Wire Rope and Drum, etc.)
① The connection between the wire rope and the drum, jib, trolley frame, hook block, etc. shall be made by Babbitt metal fastening, socket fastening, clamp fastening, cotter fastening, eye-splice, and clip fastening.
② When using clip fastening, it must meet the standards in the following table. In this case, the spacing between clips shall be at least 6 times the diameter of the wire rope.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34721298" alt="img34721298" >
┌──────────┬────┐
Wire rope diameter (mm) Number of clips
├──────────┼────┤
16 or less 4 items
├──────────┼────┤
5 items greater than 16 and less than or equal to 28
├──────────┼────┤
More than 28 6 or more
└──────────┴────┘
</img>
③ When securing a wire rope to a drum with clamps, there must be at least two clamps, and they must be securely fastened to prevent the wire rope from coming loose. <Newly added 2013.1.30>
④ Drums, sheaves, etc. shall be equipped with a structure that prevents the wire rope from detaching during operations such as hoisting, traveling, and traversing. <Newly added 2020.7.31>
Article 103 (Strength of Drums, etc.) Parts such as drums, shafts, and pins constituting the hoisting device, etc., shall possess sufficient strength and shall be free from wear, deformation, cracks, etc. that impede operation.
Article 104 (Safety Factor of Wire Rope)
① The safety factor of a wire rope refers to the value obtained by dividing the breaking load of the wire rope by the maximum load applied to the wire rope. In this case, the safety factor for hoisting wire ropes and wire ropes for hoisting a jib is calculated by reflecting the weight of the wire rope and the efficiency of the sheave.
② Wire ropes shall have a safety factor in accordance with the following table.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34721370" alt="img34721370" >
┌────────────────┬───┐
Types of Wire Ropes Safety Factor
├────────────────┼───┤
Kick-off Wire Rope 5.0
Wire rope for jib
Traverse Wire Rope
├────────────────┼───┤
Wire rope for supporting a jib 4.0
Auxiliary rope and fixing wire rope
└────────────────┴───┘
</img>
③ In the case of hoisting wire ropes and wire ropes for lifting jibs, there must be sufficient slack length to allow for at least two windings around the drum when the lifting device and jib are positioned at their lowest point.
④ Wire ropes for tower cranes shall be made of steel core. <Revised 2013.1.30>
Article 105 (Hoisting Chains) Hoisting chains shall meet the standards of each of the following subparagraphs.
1. The safety factor (referring to the value obtained by dividing the chain's breaking load by the maximum load applied to the chain) shall be 5 or greater.
2. Measure the five connected links, and the elongation shall be 5/100 or less of the length at the time of manufacture. In this case, the amount of wear on the sliding surface is included.
3. The reduction in the diameter of the link cross-section shall be 10/100 or less of the diameter at the time of manufacture
4. Be free from cracks and corrosion
5. There shall be no cracks or groove-shaped defects
6. No severe deformation
Article 106 (Welding) When welding steel materials used in structural parts, the provisions of each of the following subparagraphs shall apply. <Amended Oct. 21, 2009>
1. It shall be performed by arc welding or an equivalent or superior welding method
2. Welding electrodes shall conform to Korean Industrial Standard D 7004 (Coated Arc Welding Electrodes for Mild Steel) or be of equivalent or superior quality.
3. The temperature at the welding location shall be 0 degrees Celsius or higher, except when preheating the base material
4. Do not weld riveted structural parts
5. The weld shall be free from defects such as cracks, undercuts, overlaps, and craters
Article 107 (Assembly State)
① Bolts and nuts used for the assembly of major parts shall be made of materials with high tensile strength or equivalent mechanical properties, and shall be equipped with anti-loosening measures. However, in the case of friction joints using high-tensile bolts for structural parts, anti-loosening measures may be omitted.
② Bolts must have a clearance of at least 2 threads after assembling nuts, etc.
③ Each part shall not have sharp edges, and safety measures shall be taken, such as ensuring there are no protruding parts. <Newly added 2013.1.30>
4. Structural parts, such as masts, jibs, and foundations, shall use products manufactured in accordance with the standards prescribed and notified by the Minister of Land, Infrastructure and Transport. <Newly added Jan. 30, 2013; Mar. 23, 2013>
Article 107-2 (Weights) Weights installed in the air shall satisfy the standards of each of the following subparagraphs.
1. The structure shall be such that the weights are in close contact and fixed to each other to prepare for unexpected movement or removal.
2. Weight must be indicated
[This Article Newly Established 2020.7.31]
Article 108 (Installation of Winch, etc.)
① Winches used in hoisting or lifting devices must be securely fixed to prevent lifting, slipping, or shaking.
② Climbing or telescopic devices must be equipped with a structure for safe mast raising operations.
Article 108-2 (Hydraulic Lifting Device)
① The hydraulic pump piping and hose connections of the hydraulic lifting device must be designed to prevent leakage of hydraulic oil.
② The hydraulic lifting device shall be equipped with a safety valve to prevent excessive rise in hydraulic pressure.
③ Hydraulic pumps, hydraulic motors, and control valves must be constructed to withstand sudden load fluctuations.
④ The hydraulic piping of the hydraulic lifting device must be able to withstand at least three times the operating pressure.
[This Article Newly Established 2020.7.31]
Article 108-3 (Power for Slewing Devices) Power for the slewing device shall be supplied in the same manner as a slip ring. However, if it is difficult to install a slip ring, a slewing limiting device shall be installed to prevent damage to the power cable due to jib rotation.
[This Article Newly Established 2020.7.31]
Article 108-4 (Protection of Rotating Parts) Appropriate safety measures, such as installing covers or guards, shall be taken for rotating parts, such as gears, shafts, and couplings, that may pose a danger to workers.
[This Article Newly Established 2020.7.31]
Article 109 (Overwinding Prevention Device) An overwinding prevention device shall be installed on hoisting devices and lifting devices. However, this shall not apply in any of the following cases:
1. Hoisting and lifting devices using hydraulic power
2. Hoisting and lifting devices using an internal combustion engine as power
3. A hoisting device capable of structurally preventing overwinding, such as a friction clutch type
Article 110 (Performance of Overwinding Prevention Device)
① The overwinding prevention device shall comply with the standards of each of the following subparagraphs.
1. It shall have a function to automatically cut off power to the motor and stop operation in order to prevent overwinding.
2. It shall be a structure capable of adjusting the distance between the upper part of a lifting device, such as a hook (including the hoisting sheave of the said lifting device), a sheave that is likely to come into contact therewith (excluding inclined sheaves), and the lower part of a trolley frame, etc., to be 0.25 meters or more (0.05 meters or more for a direct-acting overwinding prevention device).
3. It must have a structure that is easy to inspect
② Among overwinding prevention devices, electric types shall meet the standards of each of the following subparagraphs in addition to the requirements of each subparagraph of Paragraph 1. <Amended 2009.10.21, 2021.8.27>
1. The outer casing of contacts, terminals, wiring, and other electrically conductive parts (hereinafter referred to as "electrically conductive parts" in this Article) shall be made of steel plate or have a sturdy structure.
2. The insulation condition between the energized part and the outer box shall have an insulation effect that meets the standards according to Korean Industrial Standard C 4504 (AC Electronic Switches) and Korean Industrial Standard C 4505 (Switches for Operating AC Electronic Switches).
3. On the external casing of the energized part, the rated voltage and rated current shall be indicated in an easily visible location, or a nameplate bearing these values shall be attached.
4. The insulation of wires installed under conditions where there is a risk of getting wet or where dust, etc. is flying shall not deteriorate due to water or dust, etc.
5. The structure shall be designed so that the overwinding prevention device operates when the contact is opened.
6. The temperature test results for the energized parts (referring to structures that directly cut off power) shall comply with the standards according to Korean Industrial Standard C 4504 (AC Electronic Switches).
Article 111 (Overwinding Alarm Device) Hoisting devices and lifting devices using the power of an internal combustion engine shall be equipped with an overwinding alarm device that meets the standards of each of the following subparagraphs.
1. It shall be a structure that operates when the distance between the upper part of the hook or hanging device and the sheave installed at the end of the jib reaches 1 meter.
2. It shall be a structure that prevents functional impairment due to moisture, dust, vibration, etc.
3. It shall be easy to inspect, and the alarm sound shall be sufficiently audible to workers within the working radius
Article 111-2 (Speed Limiting Device) Where a tower crane lacks an automatic braking function for operating speed and there is a risk of exceeding the maximum permissible speed, the speed limiting devices specified in each of the following subparagraphs must be installed to ensure that the operating speed remains within the maximum permissible speed.
1. Lifting speed limiting device
2. Lowering speed limiting device
3. Jib undulation speed limiter
[This Article Newly Established 2020.7.31]
Article 112 (Overload Protection Device) Tower cranes shall be equipped with an overload protection device that meets the standards of each of the following subparagraphs. However, this shall not apply if a safety valve has been installed in accordance with Article 113, Paragraph 1. <Amended Jan. 30, 2013; Jul. 31, 2020>
1. It must have received safety certification pursuant to Article 84 of the Industrial Safety and Health Act
2. When lifting 1.05 times the rated load, the hoisting operation (including the raising and lowering of the jib) shall stop with an alarm, and the structure shall be designed to make it impossible to increase the load.
3. It shall be sealed so that it cannot be arbitrarily adjusted
4. It shall be installed in an easily accessible location, and the pilot shall be able to easily hear the warning in case of overload
5. When the overload protection device operates, maintain the operating state of Subparagraph 2 until the overload is removed and the corresponding controller returns to the neutral or stop position.
Article 112-2 (Rated Load Warning Device and Verification Device)
① A rated load warning device and a rated load verification device shall be installed in the control room or remote controller of a tower crane.
② The rated load warning device shall provide a warning indication using both visual and auditory methods so that the pilot can perceive it whenever a load of 90 percent or more of the rated load is applied.
③ The rated load verification device must allow the pilot to visually confirm the state in which the rated load changes according to the position of the hook.
[This Article Newly Established 2020.7.31]
Article 112-3 (Abnormal Warning Device) An abnormal warning device conforming to the standards of each of the following subparagraphs shall be installed so that not only the operator but also surrounding workers can be aware that an abnormality has occurred in the event that an abnormality occurs in the operation of safety devices, etc., during the operation of a tower crane.
1. The structure shall ensure that the warning sound is clearly audible up to a radius of 10 meters from the center of the mast relative to the ground work surface.
2. The warning light must be installed on the turntable of the slewing device (referring to a rotary device for changing the direction of the tower crane jib), and shall have a luminous intensity of 135 candela or higher and be a structure that flashes red.
[This Article Newly Established 2020.7.31]
Article 112-4 (Alarm Device for Traveling Tower Cranes) Traveling tower cranes shall be equipped with an alarm device such as a bell or a buzzer. However, tower cranes operated from the working floor and in which the load and the operator move together shall be excluded.
[This Article Newly Established 2020.7.31]
Article 113 (Safety Valves, etc.)
① A safety valve with a set pressure indicated shall be installed in hoisting or lifting devices using hydraulic power to prevent excessive rise in hydraulic pressure.
② The hoisting device or lifting device referred to in Paragraph 1 shall be equipped with a check valve to prevent the sudden descent of the lifting mechanism caused by an abnormal decrease in hydraulic pressure. However, this shall not apply if a braking device pursuant to Article 99 is installed.
Article 114 (Inclination Angle Indicator) A tower crane equipped with a lifting and lowering device shall be equipped with an inclination angle indicator in the control cabin or on the jib so that it is easily visible to the operator.
Article 114-2 (Anemometer) An anemometer conforming to the standards of each of the following subparagraphs shall be installed at the highest point of the fixed structure of a tower crane. <Amended Aug. 27, 2021>
1. It shall be structured so that the operator can easily confirm, by sight or hearing, when the instantaneous wind speed required to suspend tower crane operation in accordance with Article 37, Paragraph 2 of the "Rules on Industrial Safety and Health Standards" is reached.
2. In the case of anemometers that move according to the wind direction, attach a mark indicating the wind direction.
3. Specify the measurable wind speed range on the display.
[This Article Newly Established 2020.7.31]
Article 115 (Release Device) Hooks shall be equipped with a release device to prevent wire ropes, etc. from coming loose. However, this shall not apply in cases where a dedicated lifting device enables the hanging of loads without the assistance of a worker.
Article 116 (Operating Circuits, etc.)
① Solenoid switches or contactors, etc., that are at risk of being closed in an operating circuit where one line of the secondary side of a control transformer is grounded shall be connected in accordance with the standards of each of the following subparagraphs.
1. Connect one end of the coil to the ground wire.
2. There shall be no switch between the coil and the ground-side wire.
② Tower cranes shall be equipped with stopping devices, such as trolley travel limit switches, that stop operation when the trolley approaches the outermost and innermost parts of the jib.
③ Tower cranes shall be equipped with a swing angle limiting switch to protect electrical wiring, etc., between the slewing structure and the fixed part. However, this shall not apply if protection of the electrical wiring, etc. is structurally possible.
④ An incoming switch shall be installed at the incoming point for supplying power to the tower crane in accordance with the standards of each of the following subparagraphs. <Amended Aug. 27, 2021>
1. The capacity of the incoming switch shall be greater than or equal to the load rated current capacity of the relevant tower crane, and shall be less than or equal to the sum of 2.5 times the motor rated current and other load currents.
2. The incoming switch box shall be installed in a conspicuous location where the power to the tower crane can be easily switched on and off from the ground.
3. Attach a nameplate indicating the name of the relevant tower crane and the power supply rating to the external casing of the incoming switch.
4. Install a locking device
Article 116-2 (Electricity Relations)
① A nameplate indicating the control panel name, rated voltage of the power supply, frequency, and constants, etc., must be attached to each control panel.
② The lighting device shall comply with the standards of each of the following subparagraphs.
1. The cockpit lighting shall be designed so as not to interfere with control.
2. Night work lighting shall be designed so as not to interfere with the work of pilots and signalmen
③ Tower cranes installed outdoors shall be equipped with devices to protect them from lightning strikes in accordance with the classifications in each of the following subparagraphs.
1. In cases where the cross-sectional area of the mast steel structure is 300 square millimeters or less (excluding cases where the mast connection is electrically continuous): Install lightning rods and conductors, etc.
2. In cases where the cross-sectional area of the steel mast structure exceeds 300 square millimeters or the mast connection is electrically continuous: When performing lightning protection grounding work, the lightning conductor and the object to be grounded or the grounding electrode shall be securely fastened together by welding or bolts, and the lightning protection grounding work shall be performed using corrosion-resistant materials.
④ Wiring shall be captyre cables conforming to the Korean Industrial Standard (KS C IEC60502-1) or shall possess dielectric strength, oil resistance, strength, and durability equal to or greater than that thereof, and the wire gauge shall be manufactured with a structure suitable for the relevant electrical machinery and equipment.
[This Article Newly Established 2020.7.31]
Article 117 (Controller)
① Tower cranes equipped with a control cabin shall display information regarding the type of operation, direction, emergency stop, etc., in a location easily visible to the operator. However, this shall not apply if the tower crane automatically returns to a position where operation stops when the operator releases their hands from the controller.
② The wireless remote controller of a tower crane shall meet the requirements of each of the following subparagraphs. <Amended 2013.1.30>
1. Markings consistent with the type and direction of operation of the tower crane must be displayed, and the crane must not be operated at intermediate positions other than the designated operating position.
2. The wireless remote controller shall not malfunction or become inoperable due to interference from the operating frequencies of other wireless remote controllers installed nearby or similar operating mechanisms in the vicinity.
3. The wireless remote controller shall be designed to stop operation immediately upon receiving an impact during use.
4. If combined with a cockpit, pendant switch, or radio remote control, a selector switch shall be installed.
5. Install locking devices, etc. on wireless remote controllers to prevent handling by persons other than authorized personnel.
6. Each controlled tower crane shall be indicated on the wireless remote controller.
7. The tower crane shall not be operated by signals other than those from a designated wireless remote controller.
8. The wireless remote controller shall be structured so that the tower crane automatically stops in cases corresponding to any of the following items
A. When a stop signal is received
B. When a system fault signal is detected
c. If a clear signal is not detected within the specified time
9. In the case of a controller using battery power, dangerous situations shall not be caused by changes in battery power.
10. If there are two or more controllers, ensure that the operation of the tower crane is controlled by only one controller.
11. The wireless remote controller shall have push buttons or lever-type switches, etc., operate normally, and automatically return to the stop position when the hand is released.
12. Lever-type switches shall be equipped with a mechanical locking device or a deadman's handle circuit at the stop position.
③ A sign indicating the same direction as the tower crane's operating direction displayed on the pendant switch or wireless remote controller must be attached in a location easily visible to the operator.
Article 117-2 (Image Verification Device) Tower cranes operated using a remote controller shall be equipped with an image verification device at the following locations so that the operator can verify whether the wire rope has detached and the lifting status of the heavy load.
1. Location where the operating status of the hoisting device can be checked
2. Location to check the operating status of the jib tilting device
3. Locations according to the classifications in each of the following items where the lifting status of heavy objects can be verified
A. In the case of a horizontal jib type, the trolley
B. In the case of a luffing jib type, the end of the main jib
[This Article Newly Established 2020.7.31]
Article 118 (Emergency Stop Device) A tower crane shall be equipped with an emergency stop switch that meets the standards of each of the following subparagraphs at a location where the operator can operate it in an emergency.
1. Ensure that the power supplied to the tower crane is cut off when the emergency stop switch is operated.
2. The operation immediately preceding the emergency stop operation shall not be automatically triggered by the return of the emergency stop switch.
3. The emergency stop push button shall be marked in red, and shall have a structure in which the head part protrudes and allows for manual return.
Article 119 (Pendant Switch)
① The pendant switch shall be equipped with a push button for the emergency stop of the tower crane and push buttons or switches for each type of operation that automatically return to the stop position when the hand is released, and shall operate normally.
② The voltage of the electrical circuit for operating the pendant switch shall be 150 volts or less for AC ground or 300 volts or less for DC.
③ Wires connected to the pendant switch must be supported by auxiliary wire ropes or the like to prevent twisting or the application of excessive force, and a ground wire must be connected. However, if the external box structure of the pendant switch is an insulated product, a ground wire may not be connected. <Revised Aug. 27, 2021>
④ The outer casing of a pendant switch shall be of an easily identifiable color and shall meet or exceed the protection class specified in each of the following subparagraphs in accordance with the classification of protection classes for outer casings of rotating machinery under the Korean Industrial Standard. <Newly added 2013.1.30, 2021.8.27>
1. For indoor use: IP 43 (Ingress Protection 43)
2. For outdoor use: IP 55 (Ingress Protection 55)
⑤ The pendant switch shall be located at a height of 0.9 meters or more and 1.7 meters or less from the floor surface of the work location. <Newly added 2013.1.30>
Article 119-2 (Electric Shock Prevention Device)
① The electrical equipment of a tower crane shall be equipped with an electric shock prevention device to prevent electric shock accidents caused by direct or indirect contact.
② Direct contact protection and indirect contact protection of electrical devices shall comply with the Korean Industrial Standards for Electric Shock Protection.
[This Article Newly Established 2013.1.30]
Article 120 (Stopping mechanism of rail, etc.)
① A buffer device, buffer material, or a stopping mechanism with a height of at least one-quarter of the diameter of the tower crane's traversing wheel shall be installed at both ends of the traversing rail of a tower crane.
② On the traversing rails of a tower crane with a traversing speed of 48 meters per minute or more, an electrical stopping device, such as a limit switch, shall be installed at a position prior to reaching the buffer device, buffer material, and stopping mechanism pursuant to Paragraph 1.
③ On the travel rails of a traveling tower crane, a buffer device, a buffer material, or a stopping mechanism with a height of at least half the diameter of the tower crane's travel wheel shall be installed at both ends.
④ Electrical stopping devices, such as limit switches, shall be installed on the traveling rails of a traveling tower crane at a position prior to reaching the buffer device, buffer material, and stopping mechanism specified in Paragraph 3.
Article 120-2 (Release of Slewing Brake) In the event that there is a risk of a tower crane overturning due to the influence of wind, the slewing brake shall be released to enable slewing operation, so that the jib can rotate according to the direction of the wind.
[This Article Newly Established 2013.1.30]
Article 120-3 (Anti-slip Fixing Devices) Fixing devices for traveling tower cranes installed outdoors shall comply with the Korean Industrial Standards for Fixing Devices for Crane Operation and Idleness.
[This Article Newly Established 2013.1.30]
Article 120-4 (Prime mover for driving)
① Traveling tower cranes installed outdoors shall be equipped with a prime mover capable of traveling to a location where an anti-slip fixing device is installed, even when winds blow at a speed of 16 meters per second.
② The travel speed of a traveling tower crane, in which the load and the operator move together by operating a pendant switch or wireless remote controller from the working floor, shall be 45 meters per minute or less.
[This Article Newly Established 2013.1.30]
Article 120-5 (Trolley Traveling Device) The trolley traveling device shall be capable of moving along the jib under rated load conditions.
[This Article Newly Established 2020.7.31]
Article 120-6 (Trolley Basket) The width and length of a trolley basket shall be at least 0.5 meters and 0.35 meters, respectively, and the permissible load or passenger capacity shall be indicated.
[This Article Newly Established 2020.7.31]
Article 121 (Press Release)
① A walkway with a width of at least 40 centimeters shall be installed along the entire length of the jib of a tower crane. However, this shall not apply if an inspection platform or other facilities capable of inspecting the tower crane are provided.
② Reports shall comply with the standards of each of the following subparagraphs. <Amended Jan. 30, 2013, Jul. 31, 2020>
1. Install handrails at a height of at least 90 centimeters from the sidewalk surface
2. Install the intermediate band
3. Install toe boards at a height of at least 10 centimeters from the sidewalk surface. However, for the sidewalk surface of the main jib, toe boards shall be installed on only one side at a height of at least 3 centimeters; provided, if the height from the sidewalk surface to the top is 1.8 meters or more, toe boards must be installed on both sides.
4. The sidewalk surface shall be of a structure that eliminates the risk of slipping or falling.
Article 122 (Ladders) A ladder conforming to the standards of each of the following subparagraphs shall be installed on a tower crane to carry out inspection, maintenance, and examination. <Amended Jan. 30, 2013>
1. The spacing between stepping stones shall be between 25 centimeters and 35 centimeters, with equal spacing.
2. The horizontal distance between the scaffolding and the jib or other objects shall be at least 15 centimeters
3. It shall have a structure that prevents the foot from easily slipping or falling.
4. For ladders exceeding 15 meters in height, a landing shall be installed every 10 meters or less.
5. For ladders exceeding 6 meters in height, a guardrail shall be installed. In this case, the guardrail must be raised at least 2.2 meters from the ground.
6. To prevent falls, the ladder passages shall be of a non-continuous structure, such as being arranged in a zigzag pattern at each rung of the mast.
7. The cross-sectional shape of the treads shall be uniform along the entire length of the ladder, and polygonal and U-shaped treads shall be arranged so that the walking surface remains horizontal.
8. The diameter of the footplate shall be between 20 millimeters and 35 millimeters.
Article 122-2 (Rest Stairs on the Mast)
① Mast rest platforms must be installed with a structure capable of safely supporting workers across the entire cross-sectional area of the mast.
② Handrails must be installed at a height of 90 centimeters or more and 120 centimeters or less from the resting platform. However, they may not be required if fall prevention measures are taken using diagonal or horizontal members of the mast.
③ A toe board must be installed at a height of at least 10 centimeters from the resting platform. However, it may be omitted if the structure poses a danger to workers' walking due to the installation of the toe board.
[This Article Newly Established 2020.7.31]
Article 122-3 (Structure of Stairs) When stairs are installed on a traveling tower crane, they shall comply with the standards of each of the following subparagraphs.
1. The slope shall be 75 degrees or less with respect to the horizontal plane
2. The height of the step shall be 30 centimeters or less, and the width of the step shall be 10 centimeters or more.
3. When the height exceeds 10 meters, install a landing every 7 meters.
4. Install handrails along the railing
[This Article Newly Established 2020.7.31]
Article 123 (Control Cab of a Tower Crane)
① A tower crane shall be equipped with a control cabin in any of the following cases. However, this shall not apply to tower cranes operated on the work floor. <Newly added 2013.1.30>
1. Tower crane installed in locations where dust is significantly emitted
2. Tower crane installed in locations with severe temperature fluctuations
3. Tower crane installed outdoors
② The control cabin of a tower crane (including a fixed location where the tower crane is operated using a wireless remote controller or a pendant switch) shall meet the standards of each of the following subparagraphs. <Amended Jan. 30, 2013>
1. Ensure sufficient visibility for the pilot to operate safely
2. Install switches, controllers, braking systems, warning systems, etc., in locations easily accessible to the pilot.
3. Install covers or guards to prevent electric shock on live parts where there is a risk of electric shock to the pilot.
4. The control room shall be constructed to prevent the intrusion of dust.
5. Safety nets, etc. shall be installed in the control cabins of tower cranes installed in locations where there is a risk of falling objects.
6. The cockpit shall be securely fixed without shaking in a position that does not collide with lifting devices such as hooks.
7. The control room shall be equipped with adequate lighting
8. The floor of the control room shall be of a non-slip structure.
9. The driver's cab shall be naturally ventilated or equipped with a ventilation system
10. The windows of the cockpit shall be one of tempered glass, laminated glass, or glass-plastic combination glass.
11. Welds and bolts in the cockpit shall be crack-free and securely fastened.
Article 124 (Nameplates, etc.)
① A nameplate displaying the matters of each of the following subparagraphs shall be fixed or installed on the operator's cabin or control panel of a tower crane, and the contents displayed thereon shall be easily recognizable by anyone. <Amended 2020.7.31>
1. Rated Load and Model Name
2. Production Year
3. Creator
4. Production Serial Number
② A load chart for each jib length shall be attached to the cockpit, and a section-specific load and distance display board shall be attached to the jib in a location clearly visible to the operator. However, if the section-specific load and distance can be checked via a monitor installed in the cockpit, a section-specific load and distance display board may not be attached to the jib. <Revised 2009.10.21>
③ The manufacturing serial number shall be engraved in a conspicuous place on major structural parts, such as the mast and jib. <Newly added 2013.1.30>
④ The engraving pursuant to Paragraph 3 shall not be erased or made difficult to identify due to corrosion, etc. <Newly added 2013.1.30>
Article 124-2 (Warning Signs) The manufacturer of a tower crane shall attach warning signs to appropriate parts of the tower crane so as to warn of dangers that cannot be prevented by design or the installation of safety devices.
[This Article Newly Established 2013.1.30]
Article 124-3 (Video Recording Device) The manufacturer or owner of a tower crane may install a video recording device on the tower crane to verify the installation, dismantling, and lifting operations, etc.
[This Article Newly Established 2018.8.8]
Article 125 (Maintenance of Performance, etc.)
① Tower cranes shall not deform under continuous rated load conditions.
② The assembly or clamping condition of the tower crane shall not impair performance and safety, and there shall be no significant corrosion, etc.
③ Attachments such as advertising boards that may generate additional stress on the structural parts due to the influence of wind pressure not reflected in the manufacturing design shall not be installed on the upper part of a tower crane. <Amended 2009.10.21>
④ The foundation of a tower crane must be a robust structure free from cracking or differential settlement.
Article 125-2 (Fixing of Tower Cranes)
① In principle, when installing a tower crane at a height exceeding its self-supporting height, it shall be supported by the walls of a building. However, in unavoidable circumstances, such as when the tower crane cannot be supported by a wall, it may be supported by wire ropes. <Amended July 31, 2020>
② When supporting a tower crane on a wall, all of the following items must be complied with.
1. Install using materials and parts that comply with the design and manufacturing standards for each type and model, in accordance with the tower crane manufacturer's installation instructions.
2. When fixing to a concrete structure, ensure that it is sufficiently supported by methods such as embedding or penetrating.
3. In cases where it supports a facility under construction, care must be taken to ensure that the structural stability of the same facility is not affected.
③ When supporting a tower crane with wire ropes, all of the following items must be complied with.
1. The dedicated support frame for securing the wire rope shall be installed using standard methods, employing materials and components that comply with the tower crane manufacturer's design and manufacturing standards.
2. The installation angle of the wire rope shall be within 60 degrees from the horizontal plane, and there shall be at least 4 support points, installed at the same angle.
3. When securing wire ropes, use products conforming to the Korean Industrial Standards for tumble buckles, tensioning devices, clips, shackles, etc., or, in the case of parts without Korean Industrial Standards, use products of equivalent specifications. Ensure that installed tensioning devices, clips, etc. do not loosen and maintain sufficient strength and tension during use.
4. Maintain an appropriate distance between the working wire rope and the support/fixing wire rope.
[This Article Newly Established 2013.1.30]
Article 125-3 (Verification of Structure of Buildings, etc.) The building owner shall possess documents confirming that the building structure on which the tower crane is installed is capable of supporting the load caused by the tower crane.
[This Article Newly Established 2013.1.30]
Article 126 (Material Standards, etc.) Except for matters specified in this Section, detailed standards regarding the structure, specifications, and performance of tower cranes, such as material standards, allowable stress, strength calculations of structural parts, mechanical devices, and electrical devices, shall be determined and publicly notified by the Minister of Land, Infrastructure and Transport. <Amended Mar. 14, 2008; Mar. 23, 2013>
Chapter 3 General Provisions for Construction Machinery
Section 1 Prime Engine Part
Article 127 (General Structure)
① The prime mover shall be constructed to withstand shocks or sudden torque fluctuations when operating at rated output under normal working conditions.
② The concentration standards for exhaust gases shall comply with the permissible standards pursuant to Article 46 of the Air Environment Preservation Act.
③ The prime mover of construction machinery shall be free from any malfunction in the operation of its various parts, and the main starting and stopping devices shall be structured to enable the operator to start or stop the prime mover. <Revised Mar. 31, 2026>
④ The power transmission system of construction machinery shall be free from damage to connecting parts or oil leakage, etc.
Article 128 (Cooling System) The cooling water shall be able to maintain an appropriate temperature even when the prime mover operates continuously at rated speed.
Article 129 (Electrical Equipment)
① Electrical wiring must be insulated, and there must be no exposed areas.
② The wires connected to the starter motor must have sufficient capacity to allow current to flow smoothly during starting.
③ When starting the engine, it must start with three or fewer operations of the start button or switch (one operation shall take approximately 15 seconds).
④ Fuses must be installed in the circuits connecting the electrical devices and batteries of construction machinery, and the specifications and functions of each fuse must be indicated on the fuse box.
⑤ Electrical terminals and electrical switches must be covered with insulating material.
Article 129-2 (Electrical Safety of Electric Construction Machinery)
① The structure and devices of electric construction machinery shall be designed and installed to prevent the risk of electric shock to the human body and fire.
② Electrical devices of electric construction machinery using AC voltage of 600 volts or higher shall be marked with "High Voltage" and "Danger" in a location easily visible to people.
③ Electric construction machinery shall be equipped with a device capable of cutting off the power supply in the event of maintenance, operation, or the occurrence of an electrical short circuit in the construction machinery. Furthermore, in the event of an electrical short circuit, it shall be equipped with a device for automatically cutting off the power supply and an alarm function. <Amended May 27, 2013>
④ Electric construction machinery using external power shall be equipped with a device that automatically cuts off the power supply when the machinery exceeds the usage range of the power supply cable. <Newly added 2013.5.27>
[This Article Newly Established 2009.10.21]
Article 129-3 (Grounding, etc. of Electric Construction Machinery)
① Electric construction machinery using an external power source shall be equipped with a grounding device to prevent electric shock to the human body caused by current in electrical circuits, etc., and shall satisfy the insulation and grounding resistance standards in accordance with Annex 4. <Revised May 27, 2013>
② The electrical wiring of electric construction machinery shall be properly supported and constructed so as not to interfere with or be damaged by other objects.
[This Article Newly Established 2009.10.21]
Article 130 (Storage Battery)
① A storage battery with sufficient voltage and capacity and clearly marked markings must be used.
② Lead-acid batteries shall maintain a specific gravity of 1.18 or higher and 1.38 or lower. <Revised 2026.3.31>
③ The battery must be secured so that it does not move or get damaged by the vibration or shock of the construction machinery.
④ The positive (+) terminal of the battery must be marked in red to prevent confusion during wiring.
⑤ The connection terminals of the storage battery must have rubber or plastic covers capable of preventing leakage current.
⑥ The storage battery must be installed in a well-ventilated area.
Article 130-2 (High-voltage Electrical Equipment) High-voltage electrical equipment shall comply with the standards regarding insulation safety, etc., of high-voltage electrical equipment set forth in Annex 4-2. However, this shall not apply in cases where lead-acid batteries are used for driving purposes.
[This Article Newly Established 2026.3.31]
Article 130-3 (Driving Battery) Driving batteries shall comply with the standards of each of the following subparagraphs. However, this shall not apply to cases where lead-acid batteries are used for driving purposes.
1. It shall be a structure isolated from the vehicle room by walls or protective plates, etc.
2. It shall be equipped with a function capable of preventing overcharging exceeding the designed range and interrupting overcurrent.
3. It shall not ignite or explode in accordance with the physical, chemical, electrical, and thermal shock standards prescribed and notified by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2026.3.31]
Article 131 (Lubrication Devices)
① The lubrication system must be structured to maintain the lubricating oil pressure at an appropriate state.
② Flow measuring instruments (oil gauges) shall be installed in an easily accessible location and made easily identifiable. <Revised May 27, 2013>
Article 132 (Fuel System) The fuel tank, filler port, and gas exhaust port of construction machinery shall comply with the standards of each of the following subparagraphs. <Amended Aug. 27, 2021>
1. Fuel shall not leak from the fuel tank, fuel pump, fuel piping, and various joints
2. The type of fuel used must be indicated near the fuel filler neck, and it must not be easily erased by solvents such as fuel.
3. Be at least 20 centimeters away from exposed electrical terminals and electrical switches (excluding fuel tanks)
4. The fuel filler neck shall be at least 30 centimeters away from the end of the exhaust pipe
5. The fuel tank shall be structured to be separated from the cockpit by a wall or protective plate, etc.
6. The fuel tank shall be securely fixed to the construction machinery body
7. The governor (referring to the fuel injection amount regulator) of construction machinery using diesel fuel shall be sealed so that the fuel injection amount cannot be manipulated.
Article 133 (Gas Fuel System) Fuel systems of construction machinery using gaseous fuels such as liquefied petroleum gas and natural gas as fuel shall comply with the standards of each of the following subparagraphs. <Amended June 1, 2018, July 31, 2020>
1. Must meet the standards of each subparagraph of Article 132
2. The gas container shall be a container falling under any one of the following subparagraphs
a. As a container under Article 3, Subparagraph 2 of the High-Pressure Gas Safety Management Act, it must have passed the inspection pursuant to Article 17 of the same Act.
B. As a pressure vessel under Article 2, Subparagraph 4-2 of the Automobile Management Act, it shall comply with the standards of Article 35-5 of the same Act.
3. Gas cylinders shall be securely fastened to the vehicle body so as not to loosen due to the movement of the construction machinery.
4. Protective devices shall be installed on gas containers and piping where necessary.
5. Gas containers and piping shall be equipped with necessary heat dissipation devices so as not to be directly affected by heat generated by exhaust pipes and noise prevention devices.
6. Piping shall be made of steel, copper, or oil-resistant rubber. However, in the case of hydrogen gas piping, the part directly connected to the container may not be made of oil-resistant rubber.
7. Pipes with both ends fixed (excluding oil-resistant rubber pipes) shall be secured to the vehicle body in a curved shape at intervals of at least 1 meter (0.6 meters for hydrogen gas pipes).
8. Piping in high-pressure sections shall be able to withstand a pressure of 1.5 times the gas cylinder filling pressure
9. The gas filling valve shall be installed near the filling port, and for wheeled construction machinery with a maximum driving speed of 50 kilometers per hour or more, an intermediate shut-off valve operating device (including the starting device if operated by a starting device) shall be installed in a location easily accessible to the operator.
10. Gas containers and their valves, etc. shall be installed at a distance of at least 50 millimeters from the rearmost and sidemost edges of the vehicle body.
Article 133-2 (Hydrogen Fuel Cell Construction Machinery) Hydrogen fuel cell construction machinery shall comply with the standards in each of the following subparagraphs to prevent accidents caused by the leakage of hydrogen gas. <Amended Jul. 31, 2020; Mar. 31, 2026>
1. The hydrogen concentration of the gas emitted from the exhaust of hydrogen fuel cell construction machinery shall not exceed an average of 4 percent and an instantaneous maximum of 8 percent.
1-2. Even if hydrogen gas leaks from the fuel system after the automatic fuel supply shut-off device of the pressure vessel (hereinafter referred to as the "shut-off valve" in this paragraph), the hydrogen concentration in the air in the cockpit, sealed or semi-sealed space, etc. shall not exceed 1 percent.
2. Install a hydrogen leak detector having the functions of each of the following items in the fuel system after the shut-off valve
a. Hydrogen concentration in the air in the cockpit, enclosed or semi-enclosed spaces, etc., exceeds a range within a 1 percent margin of error above or below 2 percent: Red warning light illuminates
B. In cockpits, enclosed or semi-enclosed spaces, etc., if the hydrogen concentration in the air exceeds a margin of error of within 1 percent above or below the 3 percent standard: Shut-off valve activation
3. Install an automatic indicator having the functions of each of the following items
A. The red warning light will illuminate if a hydrogen leak is detected
B. If the shut-off valve fails, a yellow or amber warning light will illuminate
C. If the hydrogen leak detector malfunctions, keep the red warning light continuously illuminated
D. Include visual images or text
[New article established 2018.6.1]
[Title Revised 2020.7.31]
[Moved from Article 26-4 <2020.7.31>]
Section 2 Body Part
Article 134 (Frame or Chassis) The frame or chassis shall be free from bending, cuts, cracks, or corrosion.
Article 134-2 (Chassis and Body)
① The chassis (or the vehicle body for construction machinery without a chassis) shall be of a robust structure capable of ensuring safe operation, and the vehicle body shall be firmly attached to the chassis so as not to loosen due to vibration or impact.
② Combustible parts of the vehicle body shall not come into contact with the exhaust pipe.
[This Article Newly Established 2013.5.27]
Article 134-3 (Anti-theft Device) Truck-mounted construction machinery shall be equipped with a key locking device that complies with the standards of each of the following subparagraphs.
1. It shall be able to suppress the normal operation of the prime mover or power source when the key is removed from the locking device
2. When the key is removed from the lock, it shall be equipped with any of the following functions:
A. Function to suppress the steering function of construction machinery
B. Function to suppress the position manipulation function of the transmission
C. Function to restrain the movement of construction machinery
3. The steering function shall be able to operate normally even if the operation of the prime mover or power source is stopped while the key is not removed from the locking device
4. The number of combinations for key locking devices shall be at least 1,000. However, if the number of manufactured construction machines is 1,000 or less, the number of combinations may be based on the number of manufactured machines.
[This Article Newly Established 2013.5.27]
Article 135 (Side Guards) Truck-type construction machinery shall be equipped with side guards that meet the standards of each of the following subparagraphs. However, they may not be installed if the structure prevents pedestrians, etc. from being entangled by the rear wheels, if installation is difficult due to the vehicle body or structure of the construction machinery, or if the distance between steering axles is 2,100 millimeters or less. <Amended Oct. 21, 2009; May 27, 2013; July 31, 2020>
1. The distance between both ends of the side guard and the front and rear wheels shall be within 40 centimeters for each. However, in the case of construction machinery with a structure where it is difficult to install the side guard with a distance of within 40 centimeters between both ends and the front and rear wheels, this shall not apply when installed at the position closest to the front and rear wheels.
2. The gap between the lowest part of the side guard and the ground shall be within 50 centimeters
3. The distance between the uppermost part of the side guard and the ground shall be at least 70 centimeters. However, this shall not apply to construction machinery with a structure where it is difficult to install such a distance of at least 70 centimeters.
4. Side guards shall be positioned inside the outermost surface of the vehicle body, and the gap shall be 12 centimeters or less.
Article 136 (Rear Safety Plate)
① Truck-mounted construction machinery shall be equipped with a rear safety plate that meets the standards of each of the following subparagraphs. However, if necessary for special operations, it may be installed as a foldable type; furthermore, installation may be omitted if the structure is such that there is no risk of the front part of the vehicle body entering due to the body or structure in the event of a collision, such as with a concrete pump hopper, or if it is used only in limited locations other than roads (referring to roads as defined in Article 2, subparagraph 1 of the Road Traffic Act; hereinafter the same applies). <Amended 2009.10.21, 2013.5.27, 2020.7.31>
1. The width shall be between 50% and 100% of the width of the construction machinery.
2. The gap between the lowest part and the ground shall be within 55 centimeters
3. The minimum height of the vertical cross-section shall be at least 10 centimeters
4. The radius of curvature of the corners shall be 2.5 millimeters or more
5. The distance between both ends of the rear safety plate and the outer surfaces of the left and right outer wheels of the widest rear axle shall each be within 10 centimeters
6. The rear safety plate shall be installed within 60 centimeters inward along the longitudinal direction of the construction machine from the rear end of the vehicle body located at a height of no more than 150 centimeters from the ground. However, this shall not apply to construction machines where it is difficult to install within 60 centimeters due to the structure of the machine.
② The rear safety plate pursuant to Paragraph 1 shall comply with the test load and installation strength standards of Annex 5. <Newly added 2013.5.27>
Article 137 (Shocking Device) The shocking device shall not have any severed or loosened parts, and shall maintain balance on both the left and right sides.
Article 138 (Electric Transmission Device)
① Direct drive type electric motors shall meet the standards of each of the following subparagraphs.
1. The clutch must be detached accurately, and there should be no excessive noise during detachment.
2. The clutch must be able to transmit the designed torque at low rotational speeds, prevent overload, and have a structure with good heat dissipation efficiency.
3. The clutch shall have a structure convenient for the inspection and maintenance of each part
4. The transmission shall be noise-free, easy to operate, and reliable when operated
5. The transmission shall not leak oil
② Power shift type electric motors shall meet the standards of each of the following subparagraphs.
1. The torque converter shall not leak oil from the oil seals and other connections during operation.
2. Maintain hydraulic pressure and oil temperature inside the torque converter within an appropriate range.
Article 139 (Main Braking System)
① The main braking system installed on wheeled construction machinery shall comply with the standards of each of the following subparagraphs. <Amended 2009.10.21, 2013.5.27>
1. The braking capability of the main braking system shall comply with the standards of Attached Table 6
2. It shall be a structure that brakes all wheels equipped with a main braking system simultaneously
3. The recommended specifications for the brake fluid shall be indicated on the brake fluid reservoir
4. The main braking system and the parking braking system shall each be structured to operate independently.
② The main braking system of wheeled construction machinery shall be equipped with a warning device (referring to a warning sound or warning light) that indicates a defect in the braking function when the standard flow rate of the brake fluid (or standard air pressure in the case of a pneumatic system) is insufficient, and the warning device shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013>
1. Warning sounds or warning lights used in a warning device shall be distinguishable from warning sounds or warning lights of other warning devices. However, this shall not apply in cases where they are used in combination with the display device of a parking brake system.
2. The warning light shall be a red light of sufficient brightness and installed in a location easily visible to the pilot.
3. The warning sound shall be at least 75 decibels when measured at the pilot's ear level
③ Truck-type construction machinery shall be equipped with a warning device (referring to a warning sound or a yellow warning light) to allow the operator to check the wear condition of the main braking system lining, or the structure shall be designed so that it can be directly visually inspected from the outside of the construction machinery. <Newly added 2013.5.27, 2021.8.27>
Article 139-2 (Emergency Automatic Braking System) Truck-type construction machinery with a gross weight exceeding 3.5 tons may be equipped with an emergency automatic control system compliant with the standards of Annex 6-2.
[This Article Newly Established 2020.7.31]
Article 140 (Parking Braking System) Wheeled construction machinery (excluding excavators, cranes, loaders, and forklifts) shall be equipped with a braking system primarily used during parking that meets the standards of each of the following subparagraphs (hereinafter referred to as the "parking braking system" in this Section). <Amended July 31, 2020>
1. It shall be easily parked on a paved slope having any of the following inclinations using a pedal, lever, or other device
A. Inclination of 16/100 when loaded
B. Inclination of 20/100 when empty
2. It shall be a structure in which the locked state is maintained by a mechanical device
3. It shall be a structure capable of braking even while driving
4. The parking brake shall operate independently of the main brake.
Article 141 (Anti-lock Braking System) Notwithstanding Articles 139 and 140, construction machinery with a maximum speed of 70 kilometers per hour or more shall be equipped with an anti-lock braking system that meets the standards of each of the following subparagraphs. However, this shall not apply in cases where the machinery is used only in limited areas other than roads. <Amended Oct. 21, 2009, May 27, 2013>
1. The braking capability of the anti-lock braking system shall comply with the standards of Item 6 of Attached Table 6.
2. In the event of sudden braking, no part of the construction machinery shall deviate from a lane with a width of 3.7 meters.
3. During sudden braking, each wheel shall not lock up at speeds of 16 kilometers per hour or more, and shall be able to come to a stop without abnormal vibration.
4. Install a warning device that allows the pilot to easily recognize a failure of the anti-lock wheel main braking system.
5. The warning device of subparagraph 4 shall be of a structure that turns on when the ignition key is placed in the operating position, turns off if there is no malfunction, and remains on if there is a malfunction.
6. The anti-lock braking system of towed construction machinery (excluding construction machinery towed temporarily) shall be structured to operate in conjunction with the anti-lock braking system of the towing construction machinery.
Article 142 (Standings) Wheeled construction machinery (excluding excavators, cranes, loaders, and forklifts) shall be equipped with two or more standings that meet the standards of each of the following subparagraphs. <Amended July 31, 2020>
1. If the tire radius is less than 480 millimeters
A. Standard floor specifications: Length 320 mm or more, Width 160 mm or more
B. Stand height: 190 millimeters
C. Bracket radius: 460 millimeters
2. If the tire radius is 480 millimeters or more
A. Standard floor specifications: Length 400mm or more, Width 200mm or more
B. Stand height: 230 mm
C. Bracket radius: 560 millimeters
Article 143 (Steering System of Wheeled Construction Machinery) The steering system of wheeled construction machinery shall comply with the standards of each of the following subparagraphs.
1. The steering angle of the steering tire shall be in a proportional relationship with the rotation angle of the steering wheel
2. There shall be no significant difference in steering force between the left and right sides.
3. Each part of the steering system shall not come into contact with other parts of the construction machinery, such as the frame and chassis, during operation, shall be free from damage such as cracks or fissures, and shall not have any abnormalities in operation.
4. Delete<2020.7.31>
Article 143-2 (Steering System of Truck-Type Construction Machinery)
① The steering system of truck-type construction machinery shall comply with the standards of each of the following subparagraphs. <Amended 2020.7.31>
1. The structure shall ensure that the turning circle of the construction machine remains the same or increases when traveling tangent to a curve with a radius of 50 meters at a speed of 40 kilometers per hour.
2. The construction machine shall be capable of straight-line driving without the steering wheel being operated abnormally or the steering device vibrating abnormally while traveling up to maximum speed. However, vibration caused by the steering device pursuant to Subparagraph 7(a) shall be excluded.
3. The construction machinery shall withstand stresses generated during normal operation.
4. The steering system shall not be affected in operation by magnetic or electric fields
5. The device for adjusting the coupling structure of the steering system shall be secured by a locking device.
6. All relevant parts of the steering system requiring mechanical rigidity shall ensure the same level of safety as essential parts such as the braking system, and parts for which failure is feared to render the construction machinery uncontrollable shall be manufactured of metal or materials having similar properties, and shall not undergo serious deformation during normal operation.
7. In the event of a failure that impedes the function of the steering system (excluding failures of mechanical parts), the aircraft shall be equipped with a warning device that enables the pilot to clearly identify the failure. However, in any of the following cases, the aircraft shall be deemed to be equipped with a warning device:
A. In the case of a structure designed to intentionally generate vibration in the steering system upon failure
B. In the case of a structure where the steering control force of the construction machinery increases upon failure
8. The steering mechanism shall not catch on the pilot's clothing or accessories during operation.
② The play of the steering wheel (referring to the distance the steering wheel moves until just before the steering wheel moves) shall be within 12.5 percent of the diameter of the steering wheel of the construction machine concerned.
③ The lateral slip of the steering wheels shall be within 5 millimeters in each side for every 1 meter of driving, and the alignment of each wheel shall not impede safe driving.
④ The steering control system of truck-type construction machinery with two or more steering axles shall have a steering control force of 500 Newtons (N) or less in a failure state (excluding cases where a component mechanically transmitting steering functions fails).
[This Article Newly Established 2013.5.27]
Article 143-3 (Lane Departure Warning System) Truck-type construction machinery with a gross weight exceeding 3.5 tons shall be equipped with a lane departure warning system compliant with Annex 6-3. However, truck-type construction machinery for which the Minister of Land, Infrastructure and Transport deems it difficult or unnecessary to install a lane departure warning system, considering the structure or operating conditions of the construction machinery, may be exempt from installation.
[This Article Newly Established 2020.7.31]
Article 144 (Steering System of Tracked Construction Machinery) The steering system of tracked construction machinery shall be structured to enable left and right steering and to allow one of the tracks to be braked and rotated.
Article 145 (Tires, etc.)
① Tires must meet the standards of each of the following subparagraphs.
1. There must be no damage severe enough to cause cracks, splits, or exposure of the cord layer, and in the case of an uneven type, the depth of the unevenness must be maintained at 1.6 millimeters or more.
2. Each part of the wheels or other running gear of the construction machinery shall be securely connected.
② The tire nominal size, operating air pressure, maximum permissible load, and operating conditions shall comply with Korean Industrial Standards. However, if not specified in Korean Industrial Standards, the specifications set forth in the industrial standards of the tire manufacturing country shall apply. <Revised 2009.10.21, 2018.6.1>
③ Solid tires shall not exhibit tire deformation, heat-induced cracking, or separation of the adhesive joints under conditions of the construction machinery's maximum driving speed and maximum load capacity. <Revised Aug. 27, 2021>
④ Wheeled construction machinery with a maximum driving speed of 50 kilometers per hour or more shall be equipped with mudguards behind the wheels.
Article 146 (Tire Load Rate)
① The tire load factor is calculated according to the following formula. In this case, the number of double tires is set to 2.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34721438" alt="img34721438" >
┌─────────────────────────────────┐
Tire Load Ratio = Axle Load × 100
│ ─────────────────── │
Maximum permissible load × Number of tires
└─────────────────────────────────┘
</img>
② The tire load ratio pursuant to Paragraph 1 shall be calculated separately for the maximum load weight condition and the self-weight condition. <Amended May 27, 2013>
③ The tire load factor of construction machinery shall be 100 percent or less. However, in the case of tires on axles other than the steering axle under maximum load capacity, it shall be 120 percent or less.
Article 147 (Travel Devices of Tracked Construction Machinery) The travel devices of tracked construction machinery shall comply with the standards of each of the following subparagraphs.
1. It shall be structured to enable operation on sloped terrain and withstand severe impact when working in rocky areas.
2. Capable of working on soft ground
3. The tension of the tracks shall be adjusted evenly on the left and right sides.
4. Track pins or bushings must be designed to be easily replaceable
5. The cylinder for adjusting track tension shall be in an easily adjustable position
Article 148 (Hydraulic System)
① Oil shall not leak at the connections of the hydraulic pump's piping and hoses.
② The hydraulic system shall be equipped with a safety valve to prevent excessive rise in hydraulic pressure.
③ Hydraulic pumps, hydraulic motors, and control valves shall be constructed to withstand sudden load fluctuations. <Newly added 2013.5.27>
④ The hydraulic piping of the working device shall be able to withstand at least three times the operating pressure of the construction machinery. <Newly added 2013.5.27>
Article 148-2 (Operating fluid filters, etc.)
① When installing a hydraulic fluid filter, it must be installed in the hydraulic system to filter out impurities mixed in the hydraulic fluid and protect the hydraulic equipment.
② The hydraulic fluid tank shall have a capacity sufficient to provide cooling and bubble removal effects through the natural heat dissipation of the hydraulic fluid, or a hydraulic fluid cooler shall be installed for cooling the hydraulic fluid, and the flow rate must be verifiable.
[This Article Newly Established 2013.5.27]
Article 148-3 (Outrigger Hydraulic System, etc.)
① A safety valve shall be installed on the outriggers installed on construction machinery to prevent the construction machinery from losing balance even in the event of a hydraulic system failure.
② The outrigger actuation switch shall be installed in a location where there is no danger from the outrigger during operation by the pilot.
[This Article Newly Established 2013.5.27]
Article 149 (Cockpit)
① A cab shall be installed on construction machinery equipped with a cockpit. However, this shall not apply if the Minister of Land, Infrastructure and Transport recognizes that there is no need to install a cab due to usage conditions. <Amended Mar. 14, 2008; Mar. 23, 2013>
② The cab of a construction machinery operator's cabin must be structured to protect the operator and the equipment within the cabin, facilitate inspection and maintenance of the equipment, and be detachable depending on the intended use.
③ Doors, windows, etc., shall be constructed so that they do not easily open or close due to vibration or wind.
④ If there are high-pressure hoses or piping inside the cockpit, covers must be installed.
⑤ The operator's cab of earthwork construction machinery shall be constructed to allow for easy escape, or a device capable of breaking the window glass shall be installed inside the cab for escape in an emergency, and the escape method shall be indicated in a place easily visible to the operator inside the cab. <Amended May 27, 2013>
⑥ The cockpit shall be constructed to allow for adjustment of direction and height if necessary.
⑦ The cockpit shall be equipped with a horizontal movement device and a horizontal movement lock.
⑧ The cockpit must be able to secure a sufficient field of view during operation to improve work efficiency and prevent accidents.
⑨ In the case of construction machinery with a non-sealed cockpit cab, the electrical and control systems must be designed so that no malfunction occurs due to rain, wind, etc. <Newly added 2013.5.27>
Article 149-2 (Operation of control devices)
① In the case of construction machinery having two or more cockpits with the same control device arrangement, they must be operable in the same manner, and the connection of the control devices must be indicated by audible or visual means.
② Construction machinery capable of operating work devices from outside the cockpit using a remote controller shall be equipped with an emergency stop device that enables the operator to rapidly halt operations in emergency situations.
[This Article Newly Established 2013.5.27]
Article 149-3 (Minimum Operator's Space) The height of the operator's cabin of earthmoving construction machinery shall be at least 920 millimeters vertical from the seating reference point to the ceiling of the operator's cabin, or at least 1,000 millimeters vertical from the seat to the ceiling, and the width of the operator's cabin shall be at least 560 millimeters.
[This Article Newly Established 2013.5.27]
Article 149-4 (Ventilation and pressurization systems)
① The ventilation device installed in the control room of an earthmoving construction machine equipped with a sealed cab shall be capable of supplying purified air into the interior of the cab.
② When pressurizing to increase the air pressure inside the cab of an earthmoving construction machine equipped with a sealed cab, the pressure inside the cab must be at least 50 Pascals (Pa) higher than the external pressure.
[This Article Newly Established 2013.5.27]
Article 149-5 (Operator Protection Structures, etc.) When installing operator protection structures on earthwork construction machinery (excluding excavators), they shall comply with the standards of each of the following subparagraphs. <Amended July 31, 2020>
1. In the case of installing a capsizing protection structure, the test methods and standards for the capsizing protection structure shall comply with Attached Table 7.
2. Where fall protection structures are installed to protect the pilot from objects falling from above the cockpit, the test methods and standards for the fall protection structures shall comply with Attached Table 7.
3. Attach a label in a permanently visible location to provide information regarding the pilot's protective structure.
[This Article Newly Established 2013.5.27]
Article 149-6 (Visibility Enhancement Device)
① Truck-mounted construction machinery shall be equipped with a device for removing frost and fog from the windshield, as well as an automatic window cleaner and cleaning fluid sprayer.
② When installing an automatic window cleaner on the front windshield in accordance with Paragraph 1, it shall comply with the standards of each of the following subparagraphs.
1. There shall be at least two types of operating cycles
2. The minimum operating cycle shall be at least 20 times per minute, and the other operating cycle shall be at least 45 times per minute
3. The difference between the peak operating cycle and another operating cycle shall be at least 15 times per minute
4. It shall be designed to automatically return to the initial position when operation is stopped
[This Article Newly Established 2013.5.27]
Article 149-7 (Flammability of Cab Interior Materials) The interior materials specified in each of the following subparagraphs installed in the cab of an earthmoving construction machine equipped with a sealed cap shall burn at a rate of no more than 200 millimeters per minute (no more than 250 millimeters per minute in the case of a forklift).
1. Seat, Seat Back, and Seatbelt
2. Armrests & Headrests
3. Tea Room Ceiling, Tea Room Floor, and Mats
4. Inner Panel
[This Article Newly Established 2013.5.27]
Article 149-8 (Speedometer and Odometer)
① The speed display unit of a speedometer installed on truck-type construction machinery shall comply with the standards of each of the following subparagraphs.
1. The speed display shall allow the pilot to clearly read the speed value during day and night
2. The speed display range shall include the maximum speed of the construction machinery
3. The scale shall be divided into units of 1 kilometer, 2 kilometers, 5 kilometers, or 10 kilometers per hour
② The indication error of the speedometer installed on truck-type construction machinery shall conform to the following formula when the speed on a flat road surface is 25 kilometers per hour or higher.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34721500" alt="img34721500" >
┌─────────────────────┐
O ≤ V₁-V₂≤ V₂/10 + 6(kilometers/hour)
└─────────────────────┘
* V₁: Indicated speed (kilometers/hour), V₂: Actual speed (kilometers/hour)
</img>
③ The odometer must be structured to display the total mileage.
[This Article Newly Established 2013.5.27]
Article 149-9 (Cockpit Doors)
① Handrails for boarding and alighting and footrests shall be installed at the entrances of earthwork construction machinery. The height of the first step of the entrance footrest shall be 70 centimeters or less from the ground, and the surface of the footrest shall be rough or non-slip. However, if the upper part of a crawler track shoe can be used as a footrest at a height of 70 centimeters or less from the ground, the upper part of said shoe may be used as the first step. <Amended 2020.7.31>
② Access steps mounted on the track frame of crawler-type construction machinery shall be installed at an inward angle of no more than 15 degrees from the edge of the track shoe.
[This Article Newly Established 2013.5.27]
Article 149-10 (Wireless Remote Controller) A wireless remote controller for controlling construction machinery shall meet the requirements of each of the following subparagraphs. <Amended Aug. 27, 2021>
1. The construction machinery must be marked to correspond to its type and direction of operation, and must not be operated at intermediate positions other than the designated operating location.
2. It shall not malfunction or become inoperable due to interference from the operating frequencies of other wireless remote controllers installed nearby or similar operating mechanisms in the vicinity.
3. If the cockpit and radio remote control are combined, a selector switch shall be installed.
4. Each controlled construction machine shall be indicated on the wireless remote controller
5. The construction machine shall not be operated by signals other than those from a designated wireless remote controller
6. The wireless remote controller shall be designed so that the construction machinery automatically stops in cases falling under any of the following subparagraphs
A. When a stop signal is received
B. When a system fault signal is detected
c. If a clear signal is not detected within the specified time
7. The wireless remote controller shall comply with the technical standards pursuant to Article 45 of the Radio Waves Act
8. The wireless remote controller control box shall be equipped with an emergency stop control device
9. In the case of wireless remote controllers using battery power, dangerous situations shall not be caused by changes in battery power
10. The external casing of the wireless remote controller shall be an easily identifiable color, and the dust and water resistance rating shall be IP 65 or higher.
11. The wires connecting the wireless remote controller shall be manufactured to prevent damage from the outside
[This Article Newly Established 2013.5.27]
Article 149-11 (Control devices, etc.)
① Construction machinery equipped with a cockpit shall have the following control devices and display devices arranged so that the operator can easily operate and identify them while seated in the cockpit.
1. Main starting device, stopping device, acceleration control device and other operating devices of the prime mover
2. Operating device of braking system and power transmission system
3. Transmission, window wipers, cleaning fluid sprayers, defrosters, fog removers, headlights, lighting systems, emergency warning lights, turn signals, and horn operation devices
4. Speedometer, turn signals, driving beam, fuel system, engine coolant, lubricating oil, brake warning light, charging system, and economic driving indicator
② The return mechanism of the acceleration control device of truck-type construction machinery shall have at least two devices capable of returning the prime mover's acceleration control device from the acceleration position to the idle position when the force applied from the accelerator pedal is removed, and the operating position for each gear ratio shall be indicated on the control lever of the transmission (or a location easily identifiable by the operator if it is difficult to mark on the transmission lever).
③ The automatic transmission of truck-type construction machinery shall comply with the standards of each of the following subparagraphs.
1. The neutral position shall be between the forward position and the reverse position
2. If the control lever is installed on the steering column, the direction of operation of the control lever from the neutral position to the forward position shall be clockwise.
3. If a parking position is present, it shall be located at the end closest to the reverse position. However, this shall not apply if the steering levers are not operated in sequence.
④ When installing a vertically movable variable axle on wheeled construction machinery, the pressure regulating device must indicate the appropriate pressure range.
[This Article Newly Established 2013.5.27]
Article 150 (Seat Belts, etc.)
① Forklifts, construction machinery equipped with rollover protection structures or overturning protection structures, and wheeled construction machinery capable of reaching speeds of 30 kilometers per hour or more shall be equipped with seat belts that meet the standards of each of the following subparagraphs. <Amended Mar. 14, 2008; Mar. 23, 2013; May 27, 2013; Mar. 31, 2026>
1. It must be a product certified pursuant to Article 15 of the Industrial Standardization Act, a product safety certified pursuant to Article 5 of the Electrical Appliances and Household Goods Safety Management Act, a product conforming to internationally recognized standards, or a product recognized by the Minister of Land, Infrastructure and Transport as equivalent or superior thereto.
2. It must have a structure that allows the user to easily lock and unlock
② Truck-mounted construction machinery (limited to truck-mounted construction machinery capable of reaching a speed of 30 kilometers per hour or more) shall be equipped with a device that emits a warning light or sound so that the operator in the cockpit may be notified if the engine is started without wearing a seatbelt. <Amended May 27, 2013>
③ Seats of truck-type construction machinery shall be equipped with seat belts of three points or more. However, in the case of middle seats of the construction machinery or seats where it is difficult to install seat belts of three points or more due to the structure of the seat, two-point seat belts may be installed. <Newly added May 27, 2013>
Article 151 (Indirect Clocking Mechanisms, etc.)
① Wheeled construction machinery (excluding non-self-propelled types) shall be equipped with an indirect visibility device conforming to the standards of each of the following subparagraphs so as to check traffic or work conditions to the left, right, and rear. <Amended May 27, 2013, March 31, 2026>
1. It must have a structure that allows the field of view to be easily adjusted
2. It must be easily detachable
3. It shall be a structure and location that is not easily damaged
② Truck-mounted construction machinery with a gross weight exceeding 7.5 tons shall be equipped with an indirect watch device conforming to the standards of Annex 8. <Amended Mar. 31, 2026>
[Title Revised 2026.3.31]
Article 151-2 (Confirmation Device) Wheeled construction machinery with a cockpit installed in a sealed cab shall be equipped with, in addition to interior and exterior indirect visibility devices, a device enabling the operator to check the rear from the moment of reversing until coming to a stop. <Amended Mar. 31, 2026>
[This Article Newly Established 2013.5.27]
Article 152 (Switches, Pedales and Leveres)
① Major pedals and levers shall be installed within easy reach of the pilot, and the operating force and stroke length of major pedals and levers operated by human power shall conform to the standards in the following table.
<img src="http://www.law.go.kr/flDownload.do?flSeq=34737376" alt="img34737376" >
┌────────────────┬─────┬─────────────┐
Classification Operating Force (kg) Stroke (cm)
├─────────────┬──┼─────┼─────────────┤
If speed is less than 60km/h, pedal 90 or less 30 or less
│ ├──┼─────┼─────────────┤
Lever 50 or less, neutral position, forward/backward 30 or less
├─────────────┼──┼─────┼─────────────┤
If speed is 60km/h or higher, pedal 70 or less 30 or less
│ ├──┼─────┼─────────────┤
Lever 30 or less from neutral position forward/backward 30 or less
├─────────────┼──┼─────┼─────────────┤
Tower crane pedal 50 or less 30 or less
│ ├──┼─────┼─────────────┤
Lever 30 or less from neutral position forward/backward 30 or less
└─────────────┴──┴─────┴─────────────┘
</img>
② Switches and levers related to safety shall be marked with easily identifiable colors and equipped with a structure capable of preventing malfunctions caused by contact during operation.
③ The surface of the pedal must not be slippery, and the edges must be rounded.
Article 153 (Windows)
① Windows must be equipped with handles so that they can be easily opened from the inside.
② The space in the cockpit shall not be narrowed when the windows are opened. However, this shall not apply to earthmoving construction machinery equipped with front and rear windows that open inward. <Amended May 27, 2013>
③ The windows of the cockpit shall be made of tempered glass, laminated glass, double-glazed glass, glass-plastic composite glass, or plastic glass. However, the front windows of construction machinery falling under any of the subparagraphs of Article 73, Paragraph 1 of the Enforcement Rule of the Construction Machinery Management Act shall be laminated glass or glass-plastic composite glass. <Amended May 27, 2013, March 31, 2026>
Article 154 (Specifications, etc.)
① A specification sheet for the relevant construction machinery shall be attached to the vehicle body in a conspicuous location as prescribed by the Minister of Land, Infrastructure and Transport. <Amended Mar. 14, 2008, Mar. 23, 2013>
② Construction machinery capable of operating while slewing, such as excavators and cranes, must have a sign reading "No Access Within Working Radius" attached to or displayed on its rear. <Amended July 31, 2020>
Article 155 (Lighting Devices)
① Lighting devices shall be installed on wheeled construction machinery in accordance with the classifications in each of the following subparagraphs. <Amended 2020.7.31>
1. Construction machinery with a maximum driving speed of less than 15 kilometers per hour
A. Headlights
B. Brake lights. Provided, however, that construction machinery that decelerates or accelerates speed by flow control is excluded.
C. Rear reflector
D. Rear reflector or rear reflective sheet
2. Construction machinery with a maximum driving speed of 15 kilometers per hour or more and less than 50 kilometers per hour
A. Lighting devices corresponding to each item of Subparagraph 1
B. Turn signal
C. Number plate light
D. Taillight
E. Side marker lights
3. Construction machinery operated by a driver's license obtained pursuant to Article 80 of the Road Traffic Act in accordance with the proviso to Article 26, Paragraph 1 of the Act, or wheeled construction machinery capable of driving at a speed of 50 kilometers per hour or more
A. Lighting device according to subparagraphs 1 and 2
B. Backlight
C. Emergency flashing indicator light
② Notwithstanding the provisions of Articles 157 through 160, Articles 160-2 through 160-4, and Article 161, if it is difficult to install a lighting device at the location prescribed by the relevant regulations due to the structure of the construction machinery, the installation location may be changed.
[Wholly Revised 2009.10.21]
Article 156 (Headlights)
① Headlights shall comply with the standards set forth in each of the following subparagraphs. However, earthmoving construction machinery and construction machinery without a steering device installed on the first axle shall be excluded. <Amended May 27, 2013>
1. One must be installed on each side (in the case of a 4-light system, two are considered as one).
2. The light color shall be white
3. The luminous intensity per lamp (referring to the luminous intensity at the point of maximum luminous intensity; hereinafter the same) shall conform to the criteria of each of the following items
A. Driving Beam: 15,000 candela (12,000 candela for 4-lamp systems where the driving beam and conversion beam light up simultaneously) or more, and 112,500 candela or less.
B. Conversion Beam: Must be between 3,000 candela and 45,000 candela
4. The direction of illumination by the travel beam shall be the same as the direction of travel of the construction machinery, and the left-right, up-down amplitude illuminated by the main light axis at a distance of 10 meters in front shall comply with the criteria of each of the following items.
a. The left and right amplitudes of the main beam axis shall be within 300 millimeters. However, the leftward amplitude of the left headlight shall be within 150 millimeters.
B. The upward amplitude of the main optical axis shall be within 100 millimeters.
c. The downward amplitude of the main light axis shall be within 3/10 of the light installation height or within 300 millimeters.
5. The center point of the lights shall be symmetrical with respect to the centerline of the construction machinery and installed so that it is between 500 millimeters and 1,200 millimeters above the ground in a self-weight state. However, this shall not apply if the lights are installed at the lowest position of the vehicle body in cases where it is unavoidable due to the structure of the construction machinery.
6. The direction in which the conversion beam shines must be the same as the direction of travel of the construction machinery, and it must be a structure capable of reducing the luminous intensity of the main optical axis of the driving beam or converting the shining direction downward.
7. When illuminated, the lenses of the driving beam and the conversion beam shall not be obscured by other parts of the vehicle body when observing in accordance with each of the following items. In this case, when the driving beam and the conversion beam use a single lens, the observation angle of the conversion beam lens shall apply.
A. Driving Beam Lens Viewing Angle: Up 5°, Down 5°, Inward 5°, Outer 5°
B. Conversion Beam Lens Viewing Angle: Up 15°, Down 10°, Inward 10°, Outward 45°
8. The sum of the maximum luminous intensities of the driving beams (referring to the total sum of the maximum luminous intensities of the driving beams for each headlight installed on the construction machinery) shall be 225,000 candela or less.
② Headlights using discharge bulbs shall comply with the standards of each of the following subparagraphs in addition to the standards under Paragraph 1.
1. A device capable of automatically adjusting the optical axis of the headlights shall be installed. However, this shall not apply to construction machinery equipped with a device, such as an air suspension system, that automatically adjusts the optical axis of the headlights downward.
2. It shall not affect the electrical and electronic devices of construction machinery
[Wholly Revised 2009.10.21]
Article 157 (Side Marking Lights) Side marker lights shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013, March 31, 2026>
1. Install on both sides of the front of the construction machinery or on the front of both sides
2. The luminous intensity per lamp shall be between 4 candela and 125 candela above the lamp centerline, and between 4 candela and 250 candela below it.
3. In the self-weight state, the lights shall be symmetrical with respect to the centerline of the construction machinery, and the center point of the lights shall be installed at a position between 35 centimeters and 200 centimeters above the ground. The outermost edge of the light-emitting surface shall be installed within 40 centimeters from the outer edge of the vehicle body. However, this requirement may be omitted if the headlights are installed within 65 centimeters from the outer edge of the vehicle body.
4. The light color shall be white, yellow, or amber, and the light colors of both sides shall be identical.
[Wholly Revised 2009.10.21]
Article 158 (Number Lights, etc.) Number lights shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013; June 1, 2018; March 31, 2026>
1. It must be a structure that clearly illuminates the license plate on the rear
2. The installation and luminance standards for number lights shall comply with Attached Table 9.
3. The light color shall be white
4. Delete <2026.3.31>
5. The structure shall be such that the light source is not directly visible from immediately behind the number plate light
[Wholly Revised 2009.10.21]
Article 159 (Brake Lights)
① Brake lights shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013, July 31, 2020>
1. Install on both sides of the rear of the construction machinery
2. The light color shall be red
3. The luminous intensity per lamp shall be between 40 candela and 420 candela.
4. Brake lights used in conjunction with other lighting shall increase in luminous intensity by at least three times when braking is applied.
5. The center point of the lights shall be at a height of 35 centimeters to 200 centimeters above the ground in a self-weight state, and shall be installed symmetrically with respect to the centerline of the construction machinery.
6. Delete <2020.7.31>
7. Deleted <2018.6.1>
② One auxiliary brake light may be installed on the rear of construction machinery, and it may not be used in combination with other lights.
③ Brake lights shall be illuminated in the following cases and shall remain illuminated until the braking force is released. However, in the case of selective braking, the brake lights shall not be illuminated, and in the case of braking by an auxiliary braking device, they may be illuminated or not illuminated depending on the deceleration or acceleration. <Amended 2020.7.31, 2026.3.31>
1. When the main braking system is activated by the operator
2. When the main braking system is activated by automatic braking control. However, if the deceleration/acceleration is 1.3 meters (1.3 m/s²) or less per square second, the indicator light may not be illuminated.
[Wholly Revised 2009.10.21]
Article 160 (Turn Signals) Turn signals shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013, July 31, 2020>
1. Lights shall be installed on both sides or the side of the front and rear of construction machinery (excluding the front in the case of towed construction machinery) in a manner symmetrical with respect to the centerline of the construction machinery, and the center point of the lights shall be positioned at a height of 35 centimeters to 200 centimeters above the ground in a state of self-weight. However, if auxiliary turn signals are installed on the side, they shall be installed within 200 centimeters from the very front of the construction machinery for construction machinery less than 600 centimeters in length, and within 60 percent of the length of the construction machinery from the very front for construction machinery 600 centimeters or longer.
2. Delete <2020.7.31>
3. Delete <2018.6.1>
4. Install with a clearance of at least 50 percent of the vehicle body width
5. It shall be a structure that flashes or increases/decreases luminous intensity at a constant cycle of 60 to 120 times per minute
6. The light color shall be yellow or amber
7. The luminous intensity per lamp shall be 50 candela or more and 1,050 candela or less. However, in the case of auxiliary turn signals pursuant to the proviso of Subparagraph 1, it shall be 0.3 candela or more and 300 candela or less.
[Wholly Revised 2009.10.21]
Article 160-2 (Taillights) Taillights shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013, July 31, 2020>
1. Install on both sides of the rear of the construction machinery
2. The luminous intensity per lamp shall be between 2 candela and 25 candela.
3. The light color shall be red
4. It shall be symmetrical with respect to the centerline of the construction machinery, and the center point of the light shall be installed at a height of 35 centimeters to 200 centimeters above the ground under its own weight.
5. Delete <2020.7.31>
[This Article Newly Established 2009.10.21]
Article 160-3 (Retreat Lights, etc.) Retreat lights shall comply with the standards of each of the following subparagraphs. <Amended May 27, 2013>
1. Install on the rear of the construction machine
2. Install 2 or fewer
3. The light color shall be white or yellow, and the center point of the light shall be installed at a height of 25 centimeters to 120 centimeters above the ground under its own weight.
4. If the luminous intensity per lamp below the intersection line (H-line) between the horizontal plane on the ground passing through the light source of the lighting device and the test screen exceeds 300 candela, the main light axis shall be oriented downward, and the device shall be installed to illuminate the ground within 75 meters behind the construction machinery.
5. Ensure that the indicator light illuminates when the transmission of the construction machinery is operated to the retracted position
6. The luminous intensity per lamp shall be between 80 candela and 600 candela above the lamp centerline, and between 80 candela and 5,000 candela below it.
7. After attaching an observation marker with a diameter of 2.5 centimeters to the lens aligned with the center point of the light source, the entire observation marker shall be visible from any position within the range including 90 centimeters behind the construction machine and 90 centimeters to the left and right of its outermost edges, and within a height range of 60 centimeters to 180 centimeters.
[This Article Newly Established 2009.10.21]
Article 160-4 (Emergency Flashing Indicator Light)
① Emergency flashing indicator lights shall comply with the standards of each of the following subparagraphs. <Amended Mar. 31, 2026>
1. Install one unit each on the left and right sides of the front and rear of the construction machinery. However, in the case of towed construction machinery, one unit each must be installed on the left and right sides of the rear.
2. All emergency flashing indicator lights shall be designed to operate simultaneously
3. The hazard flashing indicator light shall be designed to be illuminated regardless of the operation of the ignition switch
② The provisions of Article 160 concerning turn signals shall apply mutatis mutandis to the standards for emergency flashing indicator lights pursuant to Paragraph 1.
[This Article Newly Established 2009.10.21]
Article 160-5 (Fog Lights)
① When installing fog lights on the front of construction machinery, they shall be installed in compliance with the standards of each of the following subparagraphs. <Amended May 27, 2013>
1. Orient the illumination toward the front direction of travel and install one on each side.
2. The luminous intensity per lamp shall be between 940 candela and 10,000 candela.
3. The light color shall be white or yellow, and the light colors of both sides shall be the same.
4. The center point of the light shall be symmetrical with respect to the vehicle centerline, and the lowest point of the light-emitting surface in a self-weight state shall be at least 25 centimeters above the ground; furthermore, the highest point of the light-emitting surface shall be installed at or lower than the highest point of the light-emitting surface of the conversion beam headlight.
5. It shall be structured to be able to turn on or off independently of the headlights while the taillights are illuminated
② When installing fog lights on the rear of construction machinery, they shall be installed in compliance with the standards of each of the following subparagraphs. <Amended May 27, 2013>
1. Install 2 or fewer
2. The center point of the light shall be installed symmetrically to the left and right with respect to the centerline of the construction machinery. However, if only one light is installed, it must be installed on the centerline of the construction machinery or to the left of the centerline.
3. The luminous intensity per lamp shall be between 150 candela and 300 candela.
4. The light color shall be red
5. The center point of the light shall be installed at a position between 25 centimeters and 100 centimeters above the ground under self-weight conditions
6. Deleted <2018.6.1>
7. The light-emitting surface of the lighting shall maintain a distance of at least 10 centimeters from the brake lights
8. It shall be structured to be able to turn on or off in conjunction with the front fog lights, or structured to be able to turn on or off independently of other lighting devices while the front fog lights are illuminated.
9. Install a lighting indicator device so that the driver can know the lighting status.
10. When illuminated, the fog light lens shall not be obscured by other parts of the vehicle body when viewed from an angle of 5 degrees vertically and 25 degrees horizontally (in the case of two fog lights, this refers to a horizontal angle of 25 degrees on the outer side of the construction machinery).
[This Article Newly Established 2009.10.21]
Article 160-6 (Parking Lights) When installing parking lights on construction machinery, they shall be installed in compliance with each of the following subparagraphs.
1. The front shall be white (amber if combined with auxiliary turn signals or side indicators), and the rear shall be red.
2. It must be a structure linked to the parking brake system
[This Article Newly Established 2009.10.21]
Article 160-7 (Work Lights)
① When installing work lights on construction machinery, the light color must be white.
② Work lights installed on truck-mounted construction machinery must be designed so that operation to turn them on while in operation is impossible, or they must be designed to automatically turn off when operating at a speed of 20 kilometers per hour or more.
[Wholly Revised 2013.5.27]
Article 160-8 (Upper End Indicator Light) When installing an upper end indicator light on construction machinery, it shall be installed in compliance with each of the following subparagraphs.
1. For the front side, there shall be two white or amber lights
2. For the rear, there shall be two red or amber lights
[This Article Newly Established 2009.10.21]
Article 161 (Rear Reflectors, etc.)
① Rear reflectors shall comply with the standards of each of the following subparagraphs. <Revised May 27, 2013, March 31, 2026>
1. Install on both sides of the rear of the construction machinery. In this case, auxiliary reflectors may be installed on the sides.
2. The shape of the reflective part shall be a shape other than a triangle, and its area shall be at least 1,000 square millimeters for small construction machinery and at least 2,000 square millimeters for other construction machinery.
3. Delete <2026.3.31>
4. The reflected light from the reflector shall be one of the following colors
A. Rear Reflector: Red
B. Auxiliary reflector on the front side: Yellow or amber
C. Auxiliary reflector on the rear side: Red or amber
5. The center point of the reflector shall be at a height of 350 millimeters or more and 1,500 millimeters or less above the ground in a self-weight state.
6. When the auxiliary reflector is of a lighting structure, the reflective performance shall comply with the standards of Subparagraph 3.
7. The reflective performance of the reflector shall conform to the standards of Attached Table 10
② The rear reflector or rear reflective sheet shall comply with the standards of each of the following subparagraphs. <Revised May 27, 2013, March 31, 2026>
1. It shall be installed on the rear of the construction machinery so as to be symmetrical to the left and right with respect to the centerline of the construction machinery. However, if a rear safety plate pursuant to Article 136 is installed, it may be installed on the rear safety plate.
2. The shape, reflective performance, and attachment method of the rear reflector or rear reflector shall conform to the standards of Attached Table 10. However, if attachment is difficult due to the structure of the construction machinery, the shape and attachment method may be different.
3. Delete <2026.3.31>
4. The reflected light of the reflective and fluorescent parts shall be the colors of each of the following items
A. Reflective part: Yellow or red
B. Fluorescent part: Red
5. The center point of the reflective part shall be at a height of 250 millimeters or more and 1,500 millimeters or less above the ground in a self-weight state
[Wholly Revised 2009.10.21]
Article 161-2 (Release Device) When installing a hook on construction machinery, a release device that prevents wire ropes, etc. from detaching must be installed. However, this shall not apply in cases where a dedicated lifting device enables load hanging without the assistance of a worker.
[This Article Newly Established 2026.3.31]
Article 162 (Connecting Device)
① The connecting device must operate accurately and be constructed so that it does not separate due to vibration or shock.
② A structural or towing hook device capable of withstanding a force of at least half of the self-weight of the construction machinery (in the case of construction machinery that moves by disassembly, this refers to the weight at which it can drive independently after disassembly) when the construction machinery is towed in the longitudinal direction shall be installed on the front or rear of the construction machinery (excluding towed construction machinery). <Amended May 27, 2013, July 31, 2020>
③ The connecting device shall be equipped with two or more mechanical safety locking devices, and the strength of the safety locking devices shall be capable of withstanding a force of at least 3.5 times the weight of the connected working device.
Article 163 (Maximum Speed Limiting Device)
① Dump trucks, truck-mounted concrete pumps, and concrete mixer trucks with a maximum driving speed exceeding 90 kilometers per hour shall be equipped with a maximum speed limiting device. <Amended Oct. 21, 2009>
② The maximum speed limiting device referred to in Paragraph 1 shall be structured so that the maximum speed of the construction machinery does not exceed 90 kilometers per hour.
Article 164 (Tachograph)
① Dump trucks, truck-mounted concrete pumps, and concrete mixer trucks shall be equipped with tachographs to verify the speed and mileage of the construction machinery by operating time. <Amended Oct. 21, 2009>
② Construction machinery required to install a tachograph pursuant to Paragraph 1 may not be required to install a tachograph if it is equipped with a maximum speed limiting device or if its maximum driving speed is 60 kilometers per hour or less.
Article 165 (Exhaust Port)
① The end of the exhaust pipe of truck-type construction machinery shall be installed so as not to protrude outside the vehicle body. <Revised Mar. 31, 2026>
② The opening direction of the exhaust port of truck-mounted construction machinery shall not be opened more than 45 degrees to the left or right with respect to the centerline of the construction machinery. <Amended Mar. 31, 2026>
③ The exhaust pipe shall not pose a risk of igniting the construction machinery or cargo, or impeding other functions of the construction machinery, and shall be installed securely.
Article 166 (Fire Extinguishing Equipment)
① At least one fire extinguisher that has received type approval, etc., in accordance with Article 37 of the Act on the Installation and Management of Firefighting Facilities shall be installed in construction machinery. <Amended Mar. 31, 2026>
② Necessary matters, such as the performance and number of fire extinguishers to be installed pursuant to Paragraph 1, shall be announced by public notice by the Minister of Land, Infrastructure and Transport in consultation with the Commissioner of the National Fire Agency. <Amended Mar. 31, 2026>
[Wholly Revised 2013.5.27]
Article 167 (Noise)
① Dump trucks, concrete mixer trucks, and truck-mounted concrete pumps shall be manufactured and assembled in compliance with the permissible noise standards for manufactured vehicles pursuant to Article 30 of the Noise and Vibration Control Act. <Amended June 30, 2010>
② Construction machinery manufactured and assembled in accordance with Paragraph 1 and in operation shall comply with the permissible noise standards for vehicles in operation pursuant to Article 35 of the Noise and Vibration Control Act. <Amended June 30, 2010>
[Wholly Revised 2009.10.21]
Article 167-2 (other parts)
① The sum of the wheel loads of the steering wheels of wheeled construction machinery (excluding forklifts) shall be at least 20 percent of the self-weight and gross weight in the driving position determined by the manufacturer, etc.
② Wheeled construction machinery must be equipped with a device that generates a warning sound of sufficient volume to be perceived by people at the rear of the machinery and in the surrounding area from the moment it starts reversing until it comes to a stop.
③ The minimum ground clearance of truck-mounted construction machinery must be at least 120 millimeters.
④ Appropriate safety devices, such as installing safety covers, must be installed on gears, cooling fans, and other dangerous parts that are easily accessible to the operator's hands while operating construction machinery.
⑤ Delete <2018.6.1>
⑥ Bolts, nuts, keys, cotters, pins, etc., of major parts shall be equipped with appropriate anti-loosening devices to prevent them from loosening unintentionally.
[This Article Newly Established 2013.5.27]
Chapter 4 Large Construction Machinery
Article 168 (Special Markings) Large construction machinery shall be affixed with or painted with special markings that comply with the standards of each of the following subparagraphs. <Amended Mar. 31, 2026>
1. In the case of large construction machinery falling under any of the requirements of each item of Subparagraph 33 of Article 2, the special marking shall be a rectangle measuring 481 millimeters in width and 100 millimeters in height, and the applicable requirement shall be indicated as follows:
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865835" alt="img12865835" >
(Example): If the width is 2.82 meters
</img>
2. In the case of large construction machinery meeting two or more of the requirements of each item of Subparagraph 33 of Article 2, the special label shall be a rectangle measuring 481 millimeters in width and 200 millimeters in height, and the applicable requirements shall be indicated as follows. However, if there are three or more applicable requirements, only the two applicable items shall be indicated in the order of gross weight, width, height, length, and minimum turning radius.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865836" alt="img12865836" >
(Example): If gross weight and width apply
</img>
3. The background of the special cover shall be black, and the text and borders shall be white; attach or painted
4. Special markings shall be affixed or painted on the surface bearing the registration number. However, if unavoidable due to the structure of the construction machinery, they may be affixed or painted on the left and right sides of the construction machinery.
5. The number of special markings to be attached or painted shall be equal to the number of registration number plates to be attached to the relevant construction machinery. However, in cases falling under the proviso of Subparagraph 4, one plate shall be attached or painted on each side (left and right).
[Title Revised 2026.3.31]
Article 169 (Special Painting and Attachment of Reflective Strips) Large construction machinery shall be specially painted or fitted with reflective strips in a form conforming to the standards of each of the following subparagraphs. However, this shall not apply to construction machinery with a maximum driving speed of less than 35 kilometers per hour. <Amended May 27, 2013; March 31, 2026>
1. In the case of construction machinery equipped with bumpers, the front and rear bumpers shall be painted sequentially, either vertically or at an angle, with a width of 120 millimeters, using one of the following: black and luminous yellow, luminous yellow and luminous red, or luminous red and luminous white, respectively, or reflective strips shall be attached.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865837" alt="img12865837" >
(Example)
</img>
2. In the case of construction machinery without bumpers, the left and right edges of the surface where the construction machinery registration number plate is attached shall be painted sequentially in black and luminous yellow, each 120 millimeters wide, either vertically or at an angle, as follows, or reflective strips shall be attached.
<img src="http://www.law.go.kr/flDownload.do?flSeq=12865670" alt="img12865670" >
(Example)
</img>
[Title Revised 2026.3.31]
Article 170 (Warning Signs) In the case of heavy construction machinery, warning signs conforming to the standards of each of the following subparagraphs shall be affixed or painted in a place easily visible to the operator inside the cockpit. <Amended Jul. 15, 2014, Mar. 31, 2026>
1. The specifications of the warning sign shall be a rectangle measuring 165 millimeters in width and 110 millimeters in height.
2. The warning sign shall contain the following content: "Caution, Operators. This construction machinery is subject to operation restrictions pursuant to Article 77 of the Road Act. Therefore, when driving on roads pursuant to Article 2 of the same Act, you may be subject to punishment if you do not obtain permission from the road management authority or disassemble and move the machine to avoid operation restrictions. Let us exercise caution to protect roads, which are the property of the people, and to ensure traffic safety."
3. The background of the warning sign shall be painted black, the text and border lines white, and the text shall be in Gothic font.
4. Delete <2026.3.31>
[Title Revised 2026.3.31]
Chapter 5 Supplementary Provisions <Newly Inserted May 27, 2013>
Article 171 (Special Provisions for Safety Standards)
① The Minister of Land, Infrastructure and Transport may grant special exceptions to safety standards for construction machinery manufactured for public purposes, such as national security and public order, or that possesses special functions and uses, in cases where it is deemed particularly necessary, taking into consideration the manufacturing purpose, use, and functions of such machinery; in such cases, conditions necessary for operation and work may be attached.
② Notwithstanding this Rule, if there is a new device superior to the devices prescribed in this Rule, or a device deemed necessary to ensure safety, the Minister of Land, Infrastructure and Transport may order the installation of such device.
③ Even in the case of construction machinery for which a special provision has been recognized pursuant to Paragraph 2, the application of other laws and regulations related to the operation of construction machinery, such as the Road Act and the Road Traffic Act, shall not be excluded.
[This Article Newly Established 2013.5.27]
Article 172 (Notification of Test Methods, etc.) The Minister of Land, Infrastructure and Transport may prescribe and notify detailed standards and test methods, etc. necessary for the implementation of the standards prescribed in this Rule.
[This Article Newly Established 2013.5.27]
Revision
Ministry of Land, Infrastructure and Transport Decree No. 1583
The Partial Amendment to the Rules on Safety Standards for Construction Machinery is hereby promulgated as follows.
May 19, 2026
Minister of Land, Infrastructure and Transport (Seal)
Partial Amendment to the Rules on Safety Standards for Construction Machinery
The Partial Amendment to the Rules on Safety Standards for Construction Machinery, Ministry of Land, Infrastructure and Transport Decree No. 1573, is hereby amended as follows.
In Note 1) of Attached Table 8, change "Subparagraph 2(c)" to "Subparagraph 2(c)2)", and amend Subparagraph 2(c) of the same table as follows.
<img src="http://www.law.go.kr/flDownload.do?flSeq=164241725" alt="img164241725" >
</img>
Supplementary Provisions
This rule shall take effect on October 1, 2026.
Reason for Enactment/Amendment
[Partial revision]
◇ Key Contents
This is intended to improve and supplement certain shortcomings observed in the operation of the current system, such as requiring the installation of extended-range proximity viewing devices for construction machinery exceeding a gross weight of 3.5 tons that is permitted to install mirrors at a height of 2.4m or more from the ground.