Rules on the Determination, Structure, and Installation Standards of Underground Public Pedestrian Facilities
247763 · 2023-01-06
Article 1 (Purpose) The purpose of this Rule is to prescribe necessary matters concerning the standards for the determination, structure, and installation of underground public pedestrian facilities pursuant to the provisions of Article 16, Paragraph 2 and Article 17, Paragraph 2 of the "Rules on the Determination, Structure, and Installation Standards of Urban Planning Facilities."
Article 2 (Definitions) The definitions of terms used in this Rule are as follows.
1. The term "underground public pedestrian facilities" refers to underground pedestrian walkways, underground plazas, underground shopping arcades installed beneath roads, plazas, etc. (hereinafter referred to as "roads, etc."), and the associated underground access facilities (including entrances; hereinafter the same applies), underground connecting passages, and ancillary facilities.
2. The term "underground pedestrian walkway" refers to a facility installed underground beneath a road, etc., for the passage of pedestrians, excluding underground passage entrance facilities and underground connecting passages. In this case, underground pedestrian crossings installed solely for the purpose of providing passage for pedestrians as a replacement for surface pedestrian crossings shall be excluded.
3. The term "underground plaza" refers to an open space installed adjacent to an underground pedestrian walkway beneath a road, etc., for the purpose of pedestrian rest, etc.
4. The term "underground shopping arcade" refers to an area where shops are lined up and installed adjacent to an underground pedestrian walkway beneath a road, etc.
5. The term "underground passage access facility" refers to a facility installed for the purpose of entering an underground public pedestrian facility from a surface road, etc., or exiting an underground public pedestrian facility to a surface road, etc., and includes the entrance and the facility extending from the entrance to the point where the access stairs or access ramp end.
6. The term "entrance/exit" refers to the part of an underground passage access facility that abuts a road, etc., on the surface.
7. The term "underground floor connection" refers to a staircase or passageway installed to enable passage between an underground pedestrian walkway and the underground floor of an adjacent building (including underground structures such as subway stations).
Article 3 (Installation Areas for Underground Public Pedestrian Facilities)
① Underground public pedestrian facilities shall be installed in any of the following areas, except as provided by other laws and regulations.
1. Downtown and sub-downtown areas where pedestrian traffic needs to be handled underground to ensure the smooth flow of surface traffic, and areas with railway stations, subway stations, or passenger bus terminals
2. An area expected to have a high population concentration according to surrounding land use plans, where it is necessary to install underground public pedestrian facilities to facilitate smooth pedestrian traffic
3. Areas containing facilities used by a large number of residents, such as sports fields, performance halls, and markets, where it is necessary to install three-dimensional underground public pedestrian facilities to facilitate the smooth flow of pedestrians
② If an area falling under any of the subparagraphs of Paragraph 1 is a flood-prone area located within the catchment area of a retention basin, underground public pedestrian facilities shall not be installed.
Article 4 (Determination, Structure, and Installation Standards for Underground Public Pedestrian Facilities)
① Underground public pedestrian facilities shall be installed in accordance with a city or county management plan after being determined in consideration of future expansion possibilities, etc. <Amended Apr. 13, 2012>
② In sections where the installation of urban or county planning facilities, such as water supply facilities, sewers, or common utility tunnels, is planned or necessary underground for roads, etc., underground public pedestrian facilities may not be installed within 4 meters of the surface. However, this shall not apply in the case of expanding existing underground public pedestrian facilities. <Amended Apr. 13, 2012>
③ Underground public pedestrian facilities shall be installed in harmony with roads, etc., to perform organic functions.
4. The scale of underground public pedestrian facilities shall be determined appropriately in anticipation of the long-term development and maintenance of the installation area.
⑤ Underground public pedestrian facilities shall be installed in consideration of connectivity with multi-use facilities, such as commercial areas, located in the basements of adjacent buildings.
6. Underground public pedestrian facilities shall be installed with sufficient consideration for the safety of surrounding buildings resulting from their installation.
Article 5 (Installation Standards for Underground Pedestrian Walkways)
① Underground pedestrian walkways shall be designed to be convenient to use and facilitate easy evacuation in the event of an emergency, and shall be installed in a manner that does not hinder the use of persons with disabilities, the elderly, pregnant women, etc.
② The width of the underground pedestrian walkway shall be calculated according to the following formula and must be at least 6 meters. The same applies to the width of each underground pedestrian walkway in cases where the underground pedestrian walkway is separated into two or more sections by underground shopping arcades, etc.
Width of underground walkway (meters) = {Maximum number of pedestrians using the underground walkway per hour (persons) / 1,600}
+ Safety margin (2 meters if there is an underground shopping arcade, 1 meter if there is no underground shopping arcade)
③ Stairs shall not be installed on the floor of underground pedestrian walkways, and the slope of the floor shall comply with the standards set forth in Subparagraph 1, Item (b) of Annex 1 of the Enforcement Rule of the Act on the Guarantee of Convenience Promotion for Persons with Disabilities, the Elderly, Pregnant Women, etc. However, stairs may be installed on the floor of underground pedestrian walkways in cases where the installation of a ramp is difficult and detailed standards regarding the evacuation and safety of users are prescribed by ordinance. <Amended 2011.11.1>
④ The ceiling height of underground pedestrian walkways must be at least 3 meters from the floor.
⑤ Underground pedestrian walkways shall be of a single-story structure and shall not have dead ends. However, if detailed standards regarding lighting, ventilation, and the evacuation and safety of users are prescribed by ordinance, underground pedestrian walkways may be of a multi-story structure. <Amended 2011.11.1>
Article 6 (Structure and Installation Standards for Underground Plazas)
① The area of the underground plaza must be at least 10% of the area of the underground shopping arcade.
② The ceiling height of the underground plaza must be at least 30 centimeters higher than the ceiling height of the underground pedestrian walkway.
③ At least one underground plaza must be installed adjacent to the underground pedestrian walkway.
Article 7 (Structure and Installation Standards, etc. of Underground Shopping Arcades)
① Underground shopping arcades shall be installed in compliance with the standards of each of the following subparagraphs.
1. The total area of shops installed in the underground shopping arcade shall be less than or equal to the sum of the area of the underground pedestrian walkway and the area of the underground plaza.
2. Shops of the underground shopping mall shall not be installed within 3 meters from the entrance to the underground public pedestrian facility (excluding underground access facilities and underground floor connecting passages) at the end of the access stairs or ramps of the underground access facilities, or from the entrance to the underground public pedestrian facility (excluding underground access facilities and underground floor connecting passages) accessed from a nearby building (including underground structures such as subway stations) using an underground floor connecting passage.
3. One side of a store installed in an underground shopping arcade shall face the underground pedestrian walkway for at least 3 meters.
4. Stores located at the corners of an underground shopping arcade shall not be installed outside the line connecting two points, each set back 2 meters along the corner from the intersection of the store corners.
5. The entrance doors of shops installed in underground shopping arcades shall be of a sliding or inward swing type.
② Stores of any business type falling under any of the following subparagraphs shall not be installed in underground shopping arcades. <Amended Jan. 6, 2023>
1. Gas handling business pursuant to the “High-Pressure Gas Safety Management Act,” the “City Gas Business Act,” and the “Act on Safety Management and Business of Liquefied Petroleum Gas”
2. Business of handling dangerous goods, etc. under the "Dangerous Goods Safety Management Act"
3. Liquor sales business pursuant to the Act on Liquor Licenses, etc. Provided, however, that stores falling under Article 9, Paragraph 5, Subparagraph 1, Item (a) or Subparagraph 2 of the Enforcement Decree of the same Act are excluded.
4. Business handling explosives, etc. under the "Act on the Control of Firearms, Swords, Explosives, etc."
5. Industries that generate noise, vibration, dust, or odors
6. Business types such as performance venues and theaters that operate in enclosed spaces or where an unspecified number of people gather at once
7. Other business types for which the installation of stores in underground shopping arcades in the relevant area is prohibited by ordinance of a Special City, Metropolitan City, or Province due to a risk to hygiene, safety, or passage.
③ In accordance with Article 19 of the Parking Lot Act, a parking lot attached to a building belonging to the underground shopping mall (hereinafter referred to as "parking lot attached to the underground shopping mall") shall be installed in the underground shopping mall. In this case, the entrance to the parking lot may be used jointly by connecting it to the basement floor of an adjacent building.
④ Facilities and equipment for shops, etc., in underground shopping arcades using gas shall be installed in compliance with the standards of each of the following subparagraphs, in addition to the standards prescribed by the “High-Pressure Gas Safety Management Act,” the “City Gas Business Act,” the “Act on Safety Management and Business of Liquefied Petroleum Gas,” the “Act on Installation, Maintenance and Safety Management of Firefighting Facilities,” and other relevant laws and regulations.
1. When using a combustion device, install an instantaneous safety device.
2. Install a gas leak detection device, and provide a device that automatically transmits the location of the gas leak to the fire control room.
3. In the event of a gas leak, a device shall be installed in the fire control room to immediately shut off the gas to prevent it from spreading to other locations.
Article 8 (Structure and Installation Standards for Underpass Access Facilities)
① At least one entrance shall be installed in a single underground passage access facility, and the width of each entrance shall be at least 2 meters. However, if only one entrance is provided, it shall be equal to or greater than the width of the underground pedestrian walkway.
② At least one upward and downward escalator shall be installed in underground passage access facilities leading directly to the underground plaza. However, if it is difficult to secure space due to buildings or structures that are difficult to relocate, etc., it may be installed in another underground passage access facility.
③ When an entrance (including an entrance to a parking lot attached to an underground shopping mall) is installed on a ground-level sidewalk, the width of the ground-level sidewalk, excluding the said entrance, shall be at least 3 meters. However, if the number of pedestrians on the ground-level sidewalk is low and it is deemed that there is no hindrance to walking, the width may be at least 2 meters.
4. Access stairs shall be installed in accordance with the provisions of Article 15 of the “Rules on Standards for Evacuation, Fire Protection, and Structures of Buildings.”
⑤ The floor at the end of an entrance facing the ground shall be constructed in a way that prevents surface water from flowing into the interior of the underground public walkway facility.
6. The inner spacing between underground passageway access facilities (including underground connecting passages in buildings that are functionally accessible and open to the general public 24 hours a day) shall be within 100 meters. However, if unavoidable due to conditions above or below ground, it may be extended within a range of 20 meters. <Amended 2011.11.1>
7. A roof or cover facility of a safe structure shall be installed at entrances to prevent rainwater, etc., from falling directly into the interior of the underground public pedestrian facility. However, if installation is difficult due to local conditions or urban aesthetics, it may be omitted following deliberation by the Urban Planning Committee affiliated with the authority approving the implementation plan for the relevant city or county planning facility project; provided, however, that the structure shall be designed to prevent rainwater, etc., from flowing into the interior of the underground public pedestrian facility. <Amended 2012.4.13>
Article 9 (Structure and Installation Standards for Underground Connections)
① Underground connecting passages may be installed when public accessibility, such as user convenience and evacuation, is enhanced overall.
② The width of the underground connecting passageway shall be the same as the width of the underground pedestrian walkway. However, this shall not apply if the underground connecting passageway is installed in a direction different from that of the underground pedestrian walkway.
③ In underground passageways connecting an underground pedestrian walkway to the basement floor of an adjacent above-ground building, access stairs conforming to the provisions of Article 8, Paragraph 4 shall be installed to connect to the ground level, and the width shall be at least 2 meters.
Article 10 (Installation Standards for Skylights, etc.) In underground public pedestrian facilities, skylights necessary for natural lighting, ventilation, and smoke exhaust shall be installed covering at least 2% of the area of the underground shopping arcade. However, if the installation of skylights is difficult, skylights or similar devices using other methods may be installed.
Article 11 (Standards for Installation of Advertisements) When installing advertisements in underground public pedestrian facilities, they shall be installed in compliance with the standards of each of the following subparagraphs, taking into consideration safety and aesthetics.
1. Advertisements shall be installed so as not to protrude more than 5 centimeters from the wall surface, and the corners of the advertisements shall not be right angles.
2. Advertisements shall be installed so as not to obstruct the identification of guide signs, such as exit lights, entrance indicator lights, and directional signs.
3. Advertisements or other attachments shall not be installed on the ceiling of underground pedestrian walkways, except for the guide signs prescribed in Subparagraph 2.
Article 12 (Types and Installation Standards of Ancillary Facilities) The types and installation standards of ancillary facilities to be installed in underground public pedestrian facilities are as follows.
1. Firefighting facilities shall be installed in accordance with the provisions of Article 9 of the Act on Installation, Maintenance and Safety Management of Firefighting Facilities
2. The central fire control room shall be installed in accordance with the standards of each of the following items
A. It shall be installed in a location that allows for easy assessment of the overall situation of the underground public pedestrian facility and easy access to the ground level.
B. Fire and smoke compartments shall be formed from other parts.
C. Equip the facility with wired and wireless communication capabilities with relevant agencies, such as civil defense agencies, fire departments, police agencies, gas operators, and underground station disaster prevention agencies (limited to cases connected to an underground station), as well as its own surveillance camera (CCTV) facilities.
3. Fire compartment facilities shall be installed in accordance with the provisions of Article 39 of the Building Act.
4. Air purification and ventilation facilities shall be installed in accordance with the provisions of Article 8 of the "Act on the Management of Indoor Air Quality in Multi-Use Facilities, etc."
5. Drainage facilities shall be installed so that their treatment capacity is at least twice the total volume of rainwater and wastewater, including natural inflow.
6. Heating and cooling facilities shall be installed using a centralized or individual air conditioning system (limited to systems capable of integrated control).
7. Elevator facilities for persons with disabilities shall be installed in accordance with Article 2 of the Enforcement Rule of the Act on the Guarantee of Convenience Promotion for Persons with Disabilities, the Elderly, and Pregnant Women, etc. However, regarding elevators, one 8-passenger standard unit shall be installed for underground shopping mall areas up to 3,000 square meters, and for areas exceeding 3,000 square meters, an additional number shall be installed at a rate of one unit for every 2,000 square meters exceeding that amount (a 16-passenger unit shall be deemed as two units).
8. Public restrooms shall be installed in accordance with the provisions of Article 7 of the "Act on Public Restrooms, etc."
9. Public telephones shall be installed so as not to obstruct pedestrian traffic.
10. The management office shall be installed in a location with convenient access to ensure the smooth maintenance and management of underground public pedestrian facilities.
Article 13 (Use of Non-combustible Materials, etc.)
① Display stands, information signs, and advertisements in underground public pedestrian facilities shall use non-combustible materials pursuant to Article 6 of the “Rules on Standards for Evacuation, Fire Protection, and Structures of Buildings, etc.” (hereinafter referred to as “non-combustible materials”) or semi-non-combustible materials pursuant to Article 7 of the same Rules.
② Non-combustible materials shall be used for interior finishing materials and insulation materials for equipment such as piping in underground public pedestrian facilities.
③ Flame-retardant materials installed in underground public pedestrian facilities shall be installed in accordance with the provisions of Article 12 of the Act on Installation, Maintenance and Safety Management of Firefighting Facilities.
Article 14 (Relationship with Other Laws)
① Except for matters prescribed in this Rule, the provisions of the Building Act, the Act on Installation, Maintenance and Safety Management of Firefighting Facilities, the Natural Disaster Countermeasures Act, the Road Act, the Public Health Management Act, and other relevant laws and regulations shall apply.
② Matters necessary for the structure and installation, etc. of underground public pedestrian facilities, other than those prescribed in this Rule, may be determined by the ordinances of Special Cities, Metropolitan Cities, and Provinces.
Article 15 (Management of Underground Public Pedestrian Facilities) In cases where matters concerning the management of underground public pedestrian facilities are determined by ordinance pursuant to the provisions of Article 43, Paragraph 3 of the National Land Planning and Utilization Act, they shall include the matters in each of the following subparagraphs.
1. Matters concerning safety education and training of relevant personnel, disaster prevention and security such as fire plans, and evacuation measures in case of emergency
2. Matters concerning restrictions on acts causing inconvenience to pedestrians, such as the external installation of product display stands and the installation of disorderly advertisements
3. Other matters concerning the maintenance, repair, and management of underground public pedestrian facilities
Revision
⊙Ministry of Land, Infrastructure and Transport Decree No. 1186
The Partial Amendment to the Rules on the Determination, Structure, and Installation Standards of Underground Public Pedestrian Facilities is hereby promulgated as follows.
January 6, 2023
Minister of Land, Infrastructure and Transport (Seal)
Partial Amendment to the Rules on the Determination, Structure, and Installation Standards of Underground Public Pedestrian Facilities
The Rules on the Determination, Structure, and Installation Standards of Underground Public Pedestrian Facilities are partially amended as follows.
In the part other than the subparagraphs of Article 7, Paragraph 2, "shall not be installed" shall be changed to "shall not be installed," and Subparagraph 3 of the same paragraph shall be as follows.
3. Liquor sales business pursuant to the Act on Liquor Licenses, etc. Provided, however, that stores falling under Article 9, Paragraph 5, Subparagraph 1, Item (a) or Subparagraph 2 of the Enforcement Decree of the same Act are excluded.
Supplementary Provisions
This rule shall take effect from the date of its promulgation.
Reason for Enactment/Amendment
[Partial revision]
◇ Reasons for Amendment and Key Contents
The purpose is to relax the scope of alcohol sales businesses prohibited from establishing stores in underground shopping arcades, in order to ease standards regarding alcohol sales businesses that are currently banned there, thereby allowing the sale of alcohol at supermarkets, convenience stores, and other establishments located within the arcades.