위험물안전관리법 시행규칙

287841 · 2026-07-01

National Fire Agency ( Dangerous Goods Safety Division ), 044-205-7485 Chapter 1 General Provisions Article 1 (Purpose) The purpose of this Ruleis to prescribe matters delegated by the Dangerous Goods Safety Management Act and its Enforcement Decree , as well as matters necessary for the implementation thereof. <Amended May 26, 2005> Article 2 (Definitions) The definitions of terms used in this Rule are as follows. <Amended May 26, 2005; September 15, 2009; Feb. 5, 2013; Jan. 22, 2016> 1. “Expressway” refers to an expressway pursuant to Article 10, subparagraph 1 of the “Road Act” . 2. The term “road” means any of the following: a. A road pursuant to Article 2, Subparagraph 1 of the Road Act B. Roads corresponding to port transportation facilities among port facilities under Article 2, Subparagraph 5 of the Port Act C. A private road pursuant to the provisions of Article 2 of the "Private Road Act" (d) Other roads used for general traffic with a width of 2 meters or more that are capable of vehicular traffic. 3. “River” means a river as defined in Article 2, subparagraph 1 of the River Act . 4. “Fire-resistant structure” means a fire-resistant structure pursuant to Article 2, subparagraph 7 of the Enforcement Decree of the Building Act . 5. “Non-combustible materials” means non-combustible materials other than glass as defined in subparagraph 10 of Article 2 of the Enforcement Decree of the Building Act . Article 3 (Designation of Dangerous Goods Product Names) ①In Item 10 of the Product Name column of Class 1 in Annex 1 of the Enforcement Decree of the Dangerous Goods Safety Management Act (hereinafter referred to as the “Decree”), the term “those prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any of the following: < Amended May 26, 2005; March 17, 2009; March 23, 2013; November 19, 2014; July 26, 2017; May 20, 2024> 1. Periodates 2. Periodic acid 3. Oxides of chromium, lead, or iodine 4. Nitrites 5. Hypochlorites 6. Chlorinated isocyanuric acid 7. Peroxodisulfates 8. Peroxobors ② In Item 11 of the product name column of Class 3 of Annex 1 of the Enforcement Decree, the term “as prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to silicon chloride compounds. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ③ In Item 10 of the product name column of Class 5 of Annex 1 of the Enforcement Decree, the term “as prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any of the following items: <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> 1. Metal azide compounds 2. Guanidine nitrate ④ In Item 4 of the product name column of Class 6 of Annex 1 of the Enforcement Decree, “those prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to interhalogen compounds. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017; May 20, 2024> Article 4 (Name of Dangerous Goods) ①Dangerous goods falling under any of the subparagraphs of Article 3, Paragraphs 1 and 3 shall each be deemed to be dangerous goods with different names. ② Dangerous goods under Item 11 of the Class 1, Item 8 of the Class 2, Item 12 of the Class 3, Item 11 of the Class 5, or Item 5 of the Class 6 of Annex 1 of the Enforcement Decree, wherein the name of the dangerous goods contained therein is different, shall each be deemed as dangerous goods of a different name. Article 5 (Criteria for Calculating Tank Volume) ① The capacity of a tank for storing or handling hazardous materials shall be the volume obtained by subtracting the spatial volume from the internal volume of the tank. In this case, the capacity of a tank fixed to a vehicle pursuant to Subparagraph 6 of Annex 2 of the Enforcement Decree for storing or handling hazardous materials (hereinafter referred to as a “mobile storage tank”) shall be no more than or equal to the maximum load capacity prescribed by the “Rules on Performance and Standards of Automobiles and Automobile Parts . ” <Amended May 26, 2005; Jan 22, 2016> ② The method for calculating the internal volume and spatial volume of tanks pursuant to the provisions of Paragraph 1 shall be determined and announced by the Commissioner of the National Fire Agency . <Amended Nov. 19, 2014; Jul. 26, 2017> ③ Notwithstanding the provisions of Paragraph 1, in the case where the maximum amount of hazardous materials within a tank handling hazardous materials at a manufacturing plant or general handling facility is less than or equal to the capacity prescribed in Paragraph 1 due to the use of a special structure or equipment, said maximum amount shall be the capacity. Chapter 2 Application for Permission and Inspection of Manufacturing Facilities, etc. Article 6 (Application for Permission to Install Manufacturing Facility, etc.) Pursuant to the first part of Article 6, Paragraph 1 of the “Dangerous Goods Safety Management Act” (hereinafter referred to as the “Act”)and Article 6 , Paragraph 1 of the Enforcement Decree, any person who intends to obtain a permission to install a manufacturing facility, etc. shall submit an application form in Form No. 1 or Form No. 2 (including an application form in electronic form) with the following documents (including electronic documents) attached to it to the Mayor of a Special City, the Mayor of a Consolidated Special City, the Mayor of a Metropolitan City, the Mayor of a Special Self-Governing City, the Governor of a Province, or the Governor of a Special Self-Governing Province (hereinafter referred to as the “City/Provincial Governor”) or the head of a fire station. However, if information regarding the attached documents can be verified through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the “Electronic Government Act,” such verification may substitute for the attached documents. <Amended May 26, 2005; December 3, 2007; December 18, 2008; November 8, 2010; January 22, 2016; May 20, 2024; July 1, 2026> 1. Drawings regarding the location, structure, and facilities of the manufacturing plant, etc., specifying the matters in each of the following subparagraphs a. Layout of major buildings and structures within and around the business premises, including the relevant manufacturing plant, etc. B. Layout and structure of parts within the building where the relevant manufacturing facility, etc. is installed that are not used for the purpose of the manufacturing facility, etc. c. Layout of buildings, structures, machinery, equipment, and other facilities constituting the relevant manufacturing plant, etc. (including an outline of the process in the case of a manufacturing plant or general handling plant) (d) Structures of buildings, structures, machinery, equipment, and other facilities used for storing or handling hazardous materials at the relevant manufacturing facility, etc. (in the case of a refueling station, including the structures of buildings and structures pursuant to the provisions of each item of Item 1 of Subparagraph V of Annex 13 ) E. Overview of electrical equipment, lightning protection equipment, fire extinguishing equipment, alarm equipment, and evacuation equipment installed in the relevant manufacturing facility, etc. f. In the case of manufacturing facilities, etc., that install equipment related to emergency measures such as pressure safety devices, leak detection devices, and emergency shut-off valves, an overview of said equipment 2. Specification of structures and equipment according to Forms No. 3 through No. 15 attached hereto corresponding to the relevant manufacturing facility, etc. 3. In the case of manufacturing facilities, etc., where fire extinguishing facilities (excluding fire extinguishing equipment) are installed, the design documents of said facilities 4. In the case of manufacturing facilities, etc., where fire detection equipment is installed, the design documents of said equipment 5. In the case of an outdoor tank storage facility with a capacity of 500,000 liters or more, design documents, construction plans, construction schedules, geological survey data, and other necessary materials regarding the foundation and ground of the tank (hereinafter referred to as the “outdoor storage tank”) and the tank body, as well as materials regarding the tank, such as descriptions regarding welded parts. 6. In the case of a rock cavern tank storage facility, design documents, construction plans, construction schedules, and geological and hydraulic survey reports for the tank body, tunnels, piping, and other facilities of the rock cavern tank. 7. In the case where the outdoor storage tank is an underground tank (referring to a cylindrical, vertical hazardous material tank in which the bottom is below the ground surface, the top is above the ground surface, and the highest liquid level of the hazardous material inside the tank is below the ground surface; hereinafter the same applies), data regarding the ground, such as design documents, construction plans, construction schedules, and geological survey data of the ground and the tank body of the relevant underground tank. 8. In the case where the outdoor storage tank is a marine tank [referring to a hazardous materials tank stationed at the same location on the sea and connected to facilities and piping, etc. installed on land; hereinafter the same applies], the design documents, construction plan, and construction schedule for the tank body, stationary facilities (referring to facilities for stationing the marine tank at the same location; hereinafter the same applies), and other facilities of said marine tank. 9. In the case of a transfer handling station, the construction plan, construction schedule, and documents pursuant to the provisions of Attached Table 1 10. A technical review report issued by the Korea Institute of Fire Industry Technology (hereinafter referred to as the “Institute”) pursuant to Article 14 of the Act on the Promotion of the Fire Industry ( limited to cases where a technical review by the Institute has been received in advance pursuant to the provisions of Article 6, Paragraph 3 of the Enforcement Decree) Article 7 (Application for Permission to Change Manufacturing Facility, etc.) A person who intends to obtain permission to change the location, structure, or facilities of a manufacturing facility, etc., pursuant tothe latter part of Article 6 , Paragraph 1 of the Act and Article 6, Paragraph 1 of the Enforcement Decree, shall submit an application form in Annex No. 16 or Annex No. 17 (including an application form in electronic document format) to the Mayor/Do Governor or Fire Chief who granted the installation permit, attaching the documents specified in each of the following subparagraphs (including electronic documents). However, if information regarding the attached documents can be verified through the joint use of administrative information pursuant to Article 36 , Paragraph 1 of the Electronic Government Act , such verification may substitute for the attached documents. <Amended May 26, 2005; December 3, 2007; November 8, 2010; July 13, 2021> 1. Certificate of Consent to Completion Inspection of Manufacturing Plant, etc. 2. Documents pursuant to the provisions of Article 6 , Subparagraph 1 (the documents under Subparagraphs (d) through (f) shall be limited to those related to the change) 3. Documents related to the change among the documents pursuant to the provisions of Article 6, subparagraphs 2 through 10 4. Documents stating fire prevention measures pursuant to the proviso of Article 9, Paragraph 1 of the Act (limited to cases where parts unrelated to the alteration work are to be used prior to the completion inspection) Article 8 (Cases Requiring Permission for Change of Manufacturing Facility, etc.) In the latter part of Article 6, Paragraph 1 of the Act , the term “matters prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to matters set forth in Annex 1-2 . <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> [Wholly Amended Aug. 3, 2006] Article 9 (Application for Technical Review, etc.) ① Any person who intends to receive a technical review in advance pursuant to Article 6 , Paragraph 3 of the Enforcement Decree shall submit an application form (including an application form in the form of an electronic document) and documents (including electronic documents) to the Institute, in accordance with the classifications in each of the following subparagraphs. However, if information regarding documents required to be submitted can be verified through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act, such verification may substitute for the submission of the documents. <Amended Dec. 18, 2008; Nov. 8, 2010; Feb. 5, 2013> 1. Application for technical review regarding matters under Article 6, Paragraph 2, Subparagraph 3, Item (a) of the Enforcement Decree : Application form in Annex 17-2 and relevant documents among the documents under Article 6 , Subparagraphs 1 (excluding Item (a)) through 4 (in cases related to a permit for change, limited to documents related to the change) 2. Application for technical review regarding matters under Article 6, Paragraph 2, Subparagraph 3, Item (b) of the Enforcement Decree: Application form in Annex 18 and relevant documents among the documents under Article 6 , Subparagraph 3 and Subparagraphs 5 through 8 (in cases related to a permit for change, limited to documents related to the change) ② If the Institute determines that the contents of the application under Paragraph 1 conform to the standards specified in each of the following subparagraphs, it shall issue a technical review report; if it determines that they do not conform, it shall notify the applicant of the reasons in writing and request supplementation. <Amended Dec. 18, 2008; Feb. 5, 2013> 1. Application for technical review regarding matters under Article 6, Paragraph 2, Subparagraph 3, Item ( a) of the Enforcement Decree : Standards in Annex 4 IV through XII, Standards in Annex 16 I, VI, XI, and XII, and relevant regulations in Annex 17 2. Application for technical review regarding matters under Article 6, Paragraph 2, Subparagraph 3, Item B of the Enforcement Decree : Standards in Annex 6 IV through VIII, XII, and XIII, and relevant regulations regarding fire extinguishing equipment in Annex 12 and Annex 17 I. [Wholly Amended Dec. 3, 2007] Article 10 (Notification of Change of Product Name, etc.) Any person who intends to report a change regarding the product name, quantity, or multiple of the designated quantity of hazardous materials stored or handled pursuant to Article 6, Paragraph 2 of the Act shall submit a report in the form of Annex No. 19 (including a report in the form of an electronic document) to the Mayor/Do Governor or the Fire Chief, attaching the Certificate of Acceptance of the Completion Inspection of the Manufacturing Facility, etc. <Amended May 26, 2005; July 13, 2021> Article 11 (Documents, etc. Concerning the Installation, etc. of Military Hazardous Materials Facilities) ①In the main text of Article 7, Paragraph 1 of the Enforcement Decree, the term “documents prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the documents pursuant to the provisions of Article 6 or 7 concerning construction work for the installation or alteration of manufacturing facilities, etc., for military purposes or military unit facilities . < Amended Mar. 17 , 2009 ; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ② In the latter part of Article 7, Paragraph 3 of the Act , the term “matters prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the matters in each of the following subparagraphs. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017; Jul. 2, 2024> 1. Date of completion and date of commencement of use of manufacturing facility, etc. 2. Results of tank safety performance inspection ( limited to cases where there are hazardous material tanks subject to tank safety performance inspection pursuant to the provisions of Article 8 , Paragraph 1 of the Enforcement Decree) 3. Results of the final inspection 4. Safety Manager Appointment Plan 5. Preventive provisions ( limited to cases of manufacturing facilities, etc. falling under any of the subparagraphs of Article 15, Paragraph 1 of the Enforcement Decree) Article 12 (Standards, etc., for Foundation and Ground Inspection) ① In Subparagraph (a) of Item 1 of Annex 4 of the Enforcement Decree, the term “standards prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the standards concerning foundations and ground pursuant to the provisions of Annex 6 IV and V among matters concerning the structure and facilities of the relevant hazardous material tank. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ② In Item 1, Subparagraph (b) of Annex 4 of the Enforcement Decree, the term “tank prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to underground tanks and offshore tanks (hereinafter referred to as “special liquid hazardous materials tanks”). <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ③ In Item 1, Subparagraph (b) of Annex 4 of the Enforcement Decree, the term “construction work prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to construction work concerning the ground in the case of underground tanks, and construction work concerning the ground of stationary facilities in the case of offshore tanks. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ④ In Item 1, Subparagraph (b) of Annex 4 of the Enforcement Decree, the term “standards prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the standards under Item 2, Subparagraph (d) of Annex 6 XII in the case of underground tanks, and the standards under Item 3, Subparagraph (d) of Annex 6 XIII in the case of offshore tanks. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ⑤ Pursuant to Article 8, Paragraph 2 of the Act , the Institute may conduct foundation and ground inspections for outdoor tank storage facilities with a capacity of 1 million liters or more by verifying the process and results of foundation and ground tests conducted by engineering business operators pursuant to the Engineering Industry Promotion Act . <Amended May 26, 2005; December 18, 2008; Feb. 5, 2013> Article 13 (Standards, etc. Concerning Water Filling and Hydrostatic Pressure Inspections) ① In Subparagraph 2 of Annex 4 of the Enforcement Decree, the term “standards prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any of the standards falling under any of the following subparagraphs. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> 1. In the case of liquid hazardous material tanks of 1 million liters or more, the standards pursuant to the provisions of Item 1, VI of Annex 6 [limited to the parts concerning the water filling test (including tests conducted by filling with a suitable liquid other than water; hereinafter the same applies) or hydrostatic pressure test] 2. In the case of liquid hazardous material tanks with a capacity of less than 1 million liters , the standards pursuant to the provisions of Annex 4 IX Item 1(a), Annex 6 VI Item 1, Annex 7 I Item 1(e), Annex 8 I Item 6, II Items 1 , 4, 6 , and III, Annex 9 Item 6, Annex 10 II Item 1 and X Item 1(a), Annex 13 III Item 3, and Annex 16 I Item 1 (limited to the parts of tank safety performance tests related to safety regarding water filling tests, hydrostatic pressure tests, and other tank leakage and deformation safety tests) ② Pursuant to the provisions of Article 8, Paragraph 2 of the Act , the Institute may conduct the hydrostatic pressure inspection under Paragraph 1, Subparagraph 2 for double-walled tanks under the provisions of Article 18, Paragraph 6 by verifying the process and results of the hydrostatic pressure test conducted by the tank safety performance tester (hereinafter referred to as the “tank tester”) under the provisions of Article 16, Paragraph 1 of the Act. <Amended Dec. 18, 2008> Article 14 (Standards, etc. Concerning Inspection of Welded Parts) ① In Subparagraph 3 of Annex 4 of the Enforcement Decree, the term “standards prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any of the standards falling under any of the following subparagraphs. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> 1. For hazardous material tanks other than special liquid hazardous material tanks: Standards pursuant to Item 2, VI of Annex 6 2. In the case of underground tanks: Standards pursuant to the provisions of Subparagraph 4)d) of Item 2, Subparagraph E of Annex 6 XII (limited to parts related to welds) ② Pursuant to the provisions of Article 8, Paragraph 2 of the Act , the Institute may conduct weld inspections by verifying the process and results of tests regarding welds conducted by the tank tester. <Amended Dec. 18, 2008> Article 15 (Standards, etc. for Inspection of Rock Rock Tanks) ① In Subparagraph 4 of Annex 4 of the Enforcement Decree, the term “standards prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the standards set forth in Annex 12 I. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> ② Pursuant to Article 8, Paragraph 2 of the Act , the Institute may conduct rock cavern tank inspections by verifying the process and results of tests concerning rock cavern tanks conducted by engineering business operators pursuant to the Engineering Industry Promotion Act . <Amended May 26, 2005; December 18, 2008; Feb. 5, 2013> Article 16 (Detailed Standards, etc. Concerning Tank Safety Performance Inspection) Except for the matters prescribed in Articles 13 through 15, necessary matters concerning the detailed standards, methods, and procedures for tank safety performance inspection, and the verification, etc. by the Institute regarding tank safety performance tests conducted by tank testers or engineering business operators, shall be determined and announced by the Commissioner of the National Fire Agency . <Amended Dec. 18, 2008; Nov. 19, 2014; Jan. 22, 2016; Jul. 26, 2017> Article 17 (Criteria for Exclusion from Weld Inspection) ① Deleted <Aug. 3, 2006> ② The criteria for being recognized as a tank excluded from weld inspection pursuant to the proviso of Article 8, Paragraph 1, Subparagraph 3 of the Enforcement Decree shall be the criteria set forth in Subparagraph 2 of Table 6 VI. [Title amended Mar. 17, 2009] Article 18 (Application for Tank Safety Performance Inspection, etc.) ①Any person required to undergo a tank safety performance inspection pursuant to Article 8, Paragraph 1 of the Act shall submit an application form in the format of Annex 20 (including an application form in the form of an electronic document) to the head of the fire station or the technical institute having jurisdiction over the installation site of the relevant hazardous material tank. However, in the case of a tank safety performance inspection (limited to water filling and hydrostatic pressure inspections) for a hazardous material tank not manufactured at the installation site, an application may be submitted to the head of the fire station having jurisdiction over the manufacturing site of the relevant hazardous material tank by attaching one copy of the structural specifications of the relevant hazardous material tank to the application form in the format of Annex 20 (including an application form in the form of an electronic document). <Amended May 26, 2005; December 3, 2007; December 18, 2008> ② Any person who wishes to undergo a tank safety performance test pursuant to the latter part of Article 8, Paragraph 1 of the Act may apply to the Institute or the tank tester by attaching one copy of the structural specifications of the relevant hazardous material tank to the application form in Annex 20. <Amended Dec. 3, 2007; Dec. 18, 2008> ③ Any person who wishes to be exempted from the water filling and hydrostatic pressure inspection pursuant to Article 9, Paragraph 2 of the Enforcement Decree shall submit a Certificate of Confirmation of Completion of Tank Test ( Form No. 21) to the Fire Chief, attaching the tank test report. <Amended Sep. 15, 2009; Jul. 13, 2021> ④ The timing of the application for tank safety performance inspection pursuant to the provisions of Paragraph 1 shall be determined according to the classifications in each of the following subparagraphs. 1. Foundation and Ground Inspection: Before the commencement of construction work regarding the foundation and ground of the hazardous material tank 2. Water Filling and Hydrostatic Pressure Inspection: Before attaching piping and other auxiliary equipment to tanks storing or handling hazardous materials 3. Weld Inspection: Before the commencement of work on the tank body 4. Rock Tank Inspection: Prior to the commencement of work regarding the main body of the rock tank ⑤ When the head of the fire station or the technical institute determines, as a result of conducting a tank safety performance inspection, that the tank complies with the standards under Article 12 , Paragraphs 1 and 4, Article 13, Paragraph 1 , Article 14, Paragraph 1 , and Article 15, Paragraph 1, they shall issue a Certificate of Conformity to the Tank Inspection in the form of Annex 21 to the person who applied for the relevant tank safety performance inspection ; however, when it is determined that the tank does not comply, they shall notify the applicant of the reasons in writing. <Amended Dec. 18, 2008; July 13, 2021> ⑥ In Article 22, Paragraph 2, Subparagraph 1, Item ( c) of the Enforcement Decree, “liquid hazardous material tanks prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to double-walled tanks pursuant to Annex 8, Item II. <Amended May 20, 2024> Article 19 (Application for Completion Inspection, etc.) ①Any person who intends to undergo a completion inspection for a manufacturing facility, etc. pursuant to Article 9 of the Act shall submit an application form in Form No. 22 or Form No. 23 (including an application form in electronic form) to the Mayor/Do Governor or the Fire Chief (or the Institutein the case of a manufacturing facility, etc. where the completion inspection is entrusted to the Institute pursuant to Article 22, Paragraph 2, Subparagraph 2 of the Enforcement Decree), attaching the documents listed in each of the following subparagraphs (including electronic documents). However, the attached documents may be submitted until the completion inspection is conducted; provided, however, that if information regarding the attached documents can be verified through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act, such verification may substitute for the attached documents. <Amended May 26, 2005; December 3, 2007; December 18, 2008; November 8, 2010; July 13, 2021; May 20, 2024> 1. Documents proving that the piping has passed pressure tests, non-destructive tests, etc. (limited to cases where pressure tests, etc. are required for piping) 2. A Certificate of Consent for Tank Inspection or a Certificate of Consent for Tank Test issued by the Fire Chief, the Institute, or the Tank Tester (excluding cases where the Fire Chief or Institute conducting the completion inspection of the relevant hazardous material tank has conducted the tank safety performance inspection of the hazardous material tank) 3. Documents proving the performance of the material (limited to double-walled tanks) ② When the Institute conducts a completion inspection pursuant to Article 22, Paragraph 2, Subparagraph 2 of the Enforcement Decree , it shall send the completion inspection report to the head of the fire station and prepare a completion inspection work ledger containing the name of the inspection subject, date and time of receipt, inspection date, inspection number, inspector, inspection result, and date of dispatch of the inspection report, and retain it for 10 years. <Amended Dec. 18, 2008; Sep. 15, 2009; May 20, 2024> ③ The Certificate of Consent to Completion Inspection under Article 10, Paragraph 2 of the Enforcement Decree shall be in accordance with Form No. 24 or Form No. 25 of the Attached Form . <Amended July 13, 2021> ④ An application for the reissuance of a Certificate of Consent to Completion Inspection pursuant to Article 10, Paragraph 3 of the Enforcement Decree shall be made using the application form in Annex 26. <Amended July 13, 2021> Article 20 (Timing of Application for Completion Inspection) The timing for applying for a completion inspection of a manufacturing facility, etc., pursuant to Article 9, Paragraph 1 of the Act shall be in accordance with the classifications in each of the following subparagraphs. <Amended Aug. 3, 2006; Dec. 18, 2008; Jul. 13, 2021> 1. In the case of manufacturing facilities, etc. with underground tanks: Before burying the said underground tank 2. In the case of mobile tank storage facilities: After completing the mobile storage tank and securing a permanent installation site (hereinafter referred to as the “permanent site”) 3. In the case of a transfer handling station: After the completion of all or part of the transfer pipeline construction. However, in the case of construction for transfer pipelines buried underground, in rivers, etc., before the transfer pipeline is buried. 4. Cases where it is difficult to conduct a final inspection after the entire construction is completed: The time specified in each of the following items a. The time when the installation of hazardous materials facilities or piping is completed and the leak test or pressure test is conducted. b. In cases where piping is installed underground, immediately before burying the portion designated by the Mayor/Do Governor, Fire Chief, or Technical Institute C. Timing of non-destructive testing for parts designated by the Institute 5. In the case of manufacturing facilities, etc. not falling under Subparagraphs 1 through 4: after the completion of construction of the manufacturing facilities, etc. Article 21 (Application for Temporary Use During Alteration Works) Pursuant to the proviso to Article 9, Paragraph 1 of the Act , any person who wishes to use a part unrelated to the alteration work during alteration work of a manufacturing facility, etc., shall apply to the Mayor/ Do Governor orChief by attaching documents (including electronic documents) stating measures for fire prevention related to the alteration work to the application form in Annex No. 16 or Annex No. 17 (including an application in electronic form) or the application form in Annex No. 27 (including an application in electronic form). <Amended May 26, 2005> Article 22 (Reporting of Succession of Status) A person who intends to report the succession of status of the installer of a manufacturing facility, etc., pursuant to Article 10, Paragraph 3 of the Act , shall submit a report in the form of Annex No. 28 (including a report in the form of an electronic document) to the Mayor/Do Governor or the Fire Chief, attaching the Certificate of Passage of the Completion Inspection of the Manufacturing Facility, etc., and documents proving the succession of status (including electronic documents). <Amended May 26, 2005; July 13, 2021> Article 23 (Reporting of Discontinuation of Use) ①Any person who intends to report the discontinuation of use of a manufacturing facility, etc. pursuant to Article 11 of the Act shall submit a report in the form of Annex No. 29 (including a report in the form of an electronic document) attached to the Certificate of Passage of the Completion Inspection of the Manufacturing Facility, etc., to the Mayor/Do Governor or the Head of the Fire Station. <Amended May 26, 2005; July 13, 2021> ② If the Mayor/Do Governor or the head of the fire station who has received the report pursuant to the provisions of Paragraph 1 verifies the relevant manufacturing facility, etc., and recognizes that safety measures necessary for the discontinuation of use, such as the removal of hazardous materials facilities, have been taken, they shall indicate the fact of acceptance on a copy of the report and notify the person who filed the report for discontinuation of use. <Amended Aug. 3, 2006> Article 23-2 (Notification of Suspension of Use or Resumption of Use, etc.) ① The term “safety measures prescribed by the Ordinance of the Ministry of the Interior and Safety, such as the removal of hazardous materials and control of access to manufacturing facilities, etc.” in Article 11-2, Paragraph 1 of the Act refers to the measures in each of the following subparagraphs. 1. Removal of hazardous materials and flammable vapors, etc. from facilities storing or handling hazardous materials, such as tanks and piping 2. Measures prohibiting entry to the relevant manufacturing facility, etc. by persons who are not related parties 3. Posting of the fact of suspension of use of the relevant manufacturing facility, etc. 4. Other measures necessary to prevent accidents involving hazardous materials ② Any person who intends to report the suspension or resumption of use of a manufacturing facility, etc. pursuant to Article 11-2, Paragraph 2 of the Act shall submit a report in the form of Annex 29-2 (including a report in the form of an electronic document) to the mayor/governor of the city/province or the head of the fire station, attaching the certificate of passing the completion inspection of the relevant manufacturing facility, etc. ③ If the mayor or provincial governor or fire chief who has received a report of suspension of use pursuant to Paragraph 2 recognizes that the safety measures under the main clause of Paragraph 1 of Article 11-2 of the Act or the performance of duties by the hazardous materials safety manager under the proviso of the same paragraph for the relevant manufacturing facility, etc. are appropriate, he or she shall indicate the fact of acceptance on a copy of the report and notify the person who made the report. [This Article Newly Inserted Oct. 21, 2021] Article 24 (Notification of Processing Results) ① Where a City or Provincial Governor receives and processes the submission of documents related to installation or alteration under Article 7 , Paragraph 1 of the Enforcement Decree; the application for installation permit under Article 6 ; the application for alteration permit under Article 7 ; the notification of change of product name, etc. under Article 10 ; the application for completion inspection under Article 19, Paragraph 1; the application for approval of temporary use under Article 21 ; the notification of succession of status under Article 22; the notification of discontinuation of use under Article 23, Paragraph 1 ; or the notification of suspension or resumption of use under Article 23-2, Paragraph 2, respectively, they shall send copies of the application or notification form and attached documents, as well as the processing results, to the head of the competent fire station. <Amended Oct. 21, 2021> ② In cases where the Mayor/Do Governor or the Fire Station Chief receives and processes the submission of documents related to installation or modification under Article 7 , Paragraph 1 of the Enforcement Decree; the application for installation permit under Article 6 ; the application for modification permit under Article 7 ; the notification of change of product name, etc. under Article 10 ; the application for completion inspection under Article 19, Paragraph 1; the notification of succession of status under Article 22 ; the notification of discontinuation of use under Article 23, Paragraph 1; or the notification of suspension or resumption of use under Article 23-2, Paragraph 2, respectively, they shall send copies of the application or notification form, the structural equipment specifications (limited to applications for installation or modification permits), and the results of processing to the competent Mayor, County Head, or District Head. <Amended Oct. 21, 2021> [Wholly Amended Aug. 3, 2006] Article 25 (Criteria for Dispositions such as Revocation of Permit, etc.) The criteria for dispositions regarding the revocation of a permit and suspension of use for manufacturing facilities, etc. pursuant to Article 12 of the Act are as set forth in Attached Table 2 . Article 26 (Amount of Surcharge) The amount of a surcharge imposed pursuant to Article 13, Paragraph 1 of the Act , based on the type of violation and the degree of violation, etc., shall be calculated according to the standards set forth in each of the following subparagraphs. 1. In the case of violations committed during the period from February 1, 2016 to December 31, 2018: Appendix 3 2. In the case of a violation committed on or after January 1, 2019: Appendix 3-2 [Wholly Amended Jan. 22, 2016] Article 27 (Procedures for Collection of Surcharges) The Enforcement Rules of the National Treasury Management Act shall applymutatis mutandis to the procedures for the collection of surcharges pursuant to Article 13, Paragraph 2 of the Act . <Amended May 26, 2005; March 17, 2009; January 22, 2016> [Title amended Mar. 17, 2009] Chapter 3 Standards for Location, Structure, and Facilities of Manufacturing Plants, etc. Article 28 (Standards for Manufacturing Facilities) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to Article 5, Paragraph 4 of the Act ( including standards and methods for the installation of non-smoking area signs pursuant to Article 19-2, Paragraph 2 of the Act , and the same applies hereinafter up to Article 40 ), those relating to manufacturing facilities areas set forth in Annex 4. <Amended July 30, 2024> Article 29 (Standards for Indoor Storage Facilities) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 4 of the Act , those concerning indoor storage facilities are as set forth in Table 5 . Article 30 (Standards for Outdoor Tank Storage Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , regarding outdoor tank storage facilities are as set forth in Table 6 . Article 31 (Standards for Indoor Tank Storage Facilities) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 4 of the Act , those concerning indoor tank storage facilities are as set forth in Table 7 . Article 32 (Standards for Underground Tank Storage Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act, regarding underground tank storage facilities are as set forth in Table 8 . Article 33 (Standards for Simple Tank Storage Facilities) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 4 of the Act , those concerning simple tank storage facilities are as set forth in Table 9 . Article 34 (Standards for Mobile Tank Storage Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , regarding mobile tank storage facilities are as set forth in Table 10 . Article 35 (Standards for Outdoor Storage Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , regarding outdoor storage facilities are as set forth in Table 11 . Article 36 (Standards for Rock Tank Storage Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , regarding rock tank storage facilities are as set forth in Table 12 . Article 37 (Standards for Fueling Stations) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 4 of the Act , those relating to fueling stations are as set forth in Table 13 . Article 38 (Standards for Sales Outlets) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , concerning sales outlets are as set forth in Table 14 . Article 39 (Standards for Transfer Handling Stations) Among the standards for the location, structure, and facilities of manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 4 of the Act , those relating to transfer handling stations are as set forth in Table 15 . Article 40 (Standards for General Handling Facilities) The standards for the location, structure, and facilities of manufacturing facilities, etc., pursuant to the provisions of Article 5, Paragraph 4 of the Act , concerning general handling facilities are as set forth in Table 16 . Article 41 (Standards for Fire Extinguishing Equipment) ① In accordance with the provisions of Article 5, Paragraph 4 of the Act , fire extinguishing equipment suitable for extinguishing fires shall be installed in manufacturing facilities, etc., according to the degree to which extinguishing fires is difficult in the event of a fire. ② The firefighting difficulty levels according to the degree of difficulty in extinguishing fires pursuant to the provisions of Paragraph 1 shall be classified into Firefighting Difficulty Grade I, Firefighting Difficulty Grade II, and Firefighting Difficulty Grade III, and the scale of manufacturing facilities, etc. corresponding to each firefighting difficulty grade, the names and maximum quantities of hazardous materials stored or handled, etc., and the types of firefighting equipment to be installed for each manufacturing facility, etc. accordingly, the suitability of each firefighting equipment, and the installation standards for firefighting equipment are as set forth in Table 17 . Article 42 (Standards for Alarm Equipment) ①In accordance with the provisions of Article 5, Paragraph 4 of the Act , manufacturing facilities, etc. (excluding mobile tank storage facilities) that store or handle hazardous materials in quantities exceeding 10 times the designated quantity specified in Annex 1 of the Enforcement Decree shall install alarm equipment capable of notifying of a fire in the event of a fire. ② The alarm equipment under Paragraph 1 shall be classified into automatic fire detection equipment, automatic fire alarm reporting equipment, emergency alarm equipment (including emergency bell devices or alarm bells), loudspeaker devices (including portable loudspeakers), and emergency broadcasting equipment; provided, however, that the types of alarm equipment to be installed and installation standards for each manufacturing facility, etc. are as set forth in Attached Table 17. <Amended Oct. 12, 2020> ③ In the case of manufacturing facilities, etc., equipped with sprinkler systems or water spray fire extinguishing systems with automatic signaling devices, they shall be deemed to have installed automatic fire detection systems in accordance with the provisions of Paragraph 2. Article 43 (Standards for Evacuation Facilities) ① Pursuant to the provisions of Article 5, Paragraph 4 of the Act , evacuation facilities shall be installed in gas stations where the second floor or higher of the building is used for the purposes of a store, rest area/restaurant, or exhibition hall, as well as in indoor gas stations. <Amended Nov. 8, 2010> ② The installation standards for evacuation facilities pursuant to the provisions of Paragraph 1 are as set forth in Table 17 . Article 44 (Detailed Standards for the Installation of Fire Extinguishing Facilities, etc.) In addition to the standards under Articles 41 through 43 , the Commissioner of the National Fire Agency shall determine and publicly announce the detailed standards necessary for the installation of fire extinguishing facilities, alarm facilities, and evacuation facilities . <Amended Nov. 19, 2014; Jul. 26, 2017> Article 45 (Type Approval of Fire Extinguishing Equipment, etc.) Fire extinguishing equipment, alarm equipment, and evacuation equipmentshall be those that have received type approval from the Commissioner of the National Fire Agency pursuant to Article 37 of the Act on the Installation and Management of Firefighting Facilities . <Amended May 26, 2005; Feb. 5, 2013; Nov. 19, 2014; Aug. 2, 2016; Jul. 26, 2017; Dec. 1, 2022> Article 46 (Application of Fire Safety Standards, etc.) With respect to installation standards, etc. for fire extinguishing equipment, alarm equipment, and evacuation equipment installed in manufacturing facilities, etc.,except for the standards set forth in Articles 41 through 44, the fire safety standards under Subparagraph 6 of Article 2 of the Act on Installation and Management of Firefighting Facilities and the seismic design standards under Article 7 of the same Act shall apply. <Amended Aug. 2, 2016; Dec. 1, 2022; May 20, 2024> [Wholly Amended Feb. 5, 2013] [Title Amended May 20, 2024] Article 47 (Special Provisions for Standards for Manufacturing Facilities, etc.) ① The Governor of a City or Province or the Head of a Fire Station shall not apply the provisions of this Chapter in any of the following cases: <Amended Mar. 17, 2009> 1. In cases where, considering the name and maximum quantity of hazardous materials, multiples of the designated quantity, methods of storage or handling of hazardous materials, the topography surrounding the manufacturing facility, etc., and other circumstances, it is recognized that the occurrence of fire and the degree of combustion, or the damage caused by a disaster such as fire, is equivalent to or less than that under the standards for the location, structure, and facilities of the manufacturing facility, etc., pursuant to the provisions of this Chapter 2. Cases involving the use of unexpected special structures or facilities that are recognized as having an effect equivalent to or greater than that based on the standards for the location, structure, and facilities of manufacturing facilities, etc., under the provisions of this Chapter ② In reviewing whether to apply special provisions to the standards for manufacturing facilities, etc., the Mayor/Do Governor or the head of the fire station may take into account the safety assessment of the relevant manufacturing facility, etc. conducted by the Institute (hereinafter referred to as “safety assessment” in this Article) regarding matters deemed to require expert technical judgment. <Newly added Mar. 17, 2009> ③ Any person who intends to undergo a safety assessment may apply for such assessment by submitting to the Institute the relevant documents among those required under Subparagraphs 1 through 4 and Subparagraphs 7 through 9 of Article 6. <Newly added Mar. 17, 2009> ④ The Institute that receives an application for safety assessment shall notify the applicant of the results of the safety assessment within 30 days, following deliberation by a committee composed of experts in the relevant field, such as Professional Engineers in Fire Protection and Master Craftsmen in Hazardous Materials (hereinafter referred to as the “Safety Assessment Committee” in this Article). <Newly added Mar. 17, 2009> ⑤ Other matters necessary for safety assessment, such as the composition and operation of the Safety Assessment Committee and application procedures, shall be determined by the President of the Institute. <Newly added Mar. 17, 2009> Article 48 (Special Provisions for Dangerous Goods Classified as Explosives) For manufacturing facilities, etc. that store or handle dangerous goodsclassified as explosives under the Act on the Safety Management of Firearms, Swords, Explosives, etc. among chlorates, perchlorates, nitrates, sulfur, iron powder, metal powder, magnesium, nitrate esters, and nitro compounds, Annex 4 Subparagraphs II, IV, IX, and X, and Annex 5 I Subparagraphs 1, 2, 4 through 8, 14, 16, II, and III shall not apply. <Amended May 26, 2005; Jan. 22, 2016; Oct. 12, 2020; May 20, 2024> Chapter 4 Standards for the Storage and Handling of Hazardous Materials Article 49 (Standards for Storage and Handling of Dangerous Goods in Manufacturing Facilities, etc.) The standards for the storage and handling of dangerous goods in manufacturing facilities, etc. pursuant to the provisions of Article 5, Paragraph 3 of the Act are as set forth in Table 18 . Chapter 5 Standards for the Transport and Transportation of Dangerous Goods Article 50 (Standards for the Transport of Dangerous Goods) The standards for the transport of dangerous goods pursuant to the provisions of Article 20, Paragraph 1 of the Act are as set forth in Table 19 . Article 51 (Inspection of Transport Containers) ① In the proviso to Article 20, Paragraph 3 of the Act , “those prescribed by the Ordinance of the Ministry of the Interior and Safety”refers to transport containers pursuant to Annex 20. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017; Jun. 10, 2021> ② Any person who wishes to undergo inspection of a transport container pursuant to Article 20, Paragraph 3 of the Act shall submit an application in the form of Annex 30 (including an application in the form of an electronic document) to the Institute, attaching the design drawings of the container and a description of the materials. However, this shall not apply if the container has been inspected by a relevant inspection agency in accordance with the standards set forth in the UN Recommendations on the Transport of Dangerous Goods (RTDG). <Amended May 26, 2005; December 18, 2008; August 2, 2016; June 10, 2021> ③ When the Institute determines that a transport container for which an inspection application has been submitted pursuant to Paragraph 2 conforms to the standards set forth in Annex 19 I and that there is no impediment to the transport of hazardous materials , it shall issue a Certificate of Conformity for Container Inspection in the form of Annex 31. <Amended Dec. 18, 2008; Jun. 10, 2021; July 13, 2021> ④ The Director of the Institute shall determine and operate the procedures and methods for handling transport container inspection work. <Amended Dec. 18, 2008; Feb. 5, 2013; Aug. 2, 2016; Jun. 10, 2021> ⑤ The Director of the Institute shall report the results of the previous year's transport container inspection work to the Mayor/Do Governor by January 31 of each year, and the Mayor/Do Governor shall submit the results of the transport container inspection work received from the Institute to the Commissioner of the National Fire Agency by the end of February of each year. <Newly added Aug. 2, 2016; Jul. 26, 2017; Jun. 10, 2021> Article 52 (Standards for Transport of Dangerous Goods) ① The person responsible for the transport of dangerous goods pursuant to the provisions of Article 21, Paragraph 2 of the Act shall be any of the persons falling under any of the following subparagraphs. 1. Persons who have obtained a national technical qualification regarding the handling of the relevant hazardous materials and have at least one year of experience in related work. 2. Persons who have completed safety training regarding the transportation of dangerous goods pursuant to Article 28, Paragraph 1 of the Act and have at least two years of experience in related work. ② The methods of supervision or support for the person responsible for the transport of dangerous goods pursuant to the provisions of Article 21, Paragraph 2 of the Act and the matters to be observed during the transport of dangerous goods pursuant to the provisions of Article 21 , Paragraph 3 of the Act are as set forth in Attached Table 21 . Chapter 6 Safety Managers, etc. Article 53 (Reporting of Appointment of Safety Manager, etc.) ① In cases where a person concerned with a manufacturing facility, etc., intends to report the appointment of a safety manager (including safety managers under Article 29 , Paragraphs 1 and 3 and Article 32 , Paragraph 1 of the Special Measures Act on Deregulation of Corporate Activities and safety management agencies under Article 57 , Paragraph 1 ) pursuant to Article 15, Paragraph 3 of the Act, they shall submit a report in the form of Annex 32 (including a report in electronic form) to the Head of the Fire Department or the Head of the Fire Station, attaching the relevant documents (including electronic documents) specified in each of the following subparagraphs. <Amended July 17, 2015; Jan. 22, 2016> 1. Contract for Dangerous Goods Safety Management Services ( limited to safety management agencies pursuant to Article 57 , Paragraph 1 ) 2. Certificate of Completion for Hazardous Materials Safety Management Training ( limited to those who have received the safety manager training course pursuant to Article 78 , Paragraph 1 and Annex 24 ) 3. Documents proving the fact of appointment as a relevant safety manager who may concurrently hold the position of hazardous materials safety manager (limited to a safety manager falling under Article 29, Paragraph 1 , Subparagraphs 1 through 3 and Paragraph 3 of the Special Measures Act on Deregulation of Corporate Activities, or a person falling under any of the subparagraphs of Article 11, Paragraph 3 of the Enforcement Decree who is not a holder of a national technical qualification in the handling of hazardous materials). 4. Certificate of Firefighter Career (Limited to those with firefighter experience) ② The public official in charge who receives a report pursuant to Paragraph 1 shall verify the administrative information set forth in each of the following subparagraphs through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act . However, if the reporter does not consent to the verification, the reporter shall be required to submit the relevant documents (in the case of a national technical qualification certificate, a copy thereof). <Amended Nov. 8, 2010> 1. National Technical Qualification Certificate (limited to holders of national technical qualifications regarding the handling of hazardous materials) 2. National Technical Qualification Certificate ( Limited to persons falling under Article 29, Paragraphs 1 and 3 of the Special Measures Act on the Deregulation of Business Activities and holders of national technical qualifications) [Wholly Amended Dec. 13, 2007] Article 54 (Deputy of Safety Manager) In the first part of Article 15, Paragraph 5 of the Act , the term “person prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any person falling under any of the following subparagraphs. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jan. 22, 2016; Aug. 2, 2016; Jul. 26, 2017> 1. Persons who have received safety education pursuant to Article 28 , Paragraph 1 of the Act 2. Deleted <August 2, 2016> 3. Persons in positions directing and supervising safety managers in hazardous materials safety management duties at manufacturing facilities, etc. Article 55 (Duties of Safety Managers) Pursuant to Article 15, Paragraph 6 of the Act , a safety manager shall faithfully perform the duties set forth in each of the following subparagraphs regarding safety management and supervision concerning the handling of hazardous materials. <Amended May 26, 2005; August 3, 2006; January 22, 2016> 1. Duties of participating in hazardous materials handling operations and directing and supervising relevant workers (including qualified hazardous materials handlers participating in said operations) to ensure that said operations comply with the technical standards for storage or handling pursuant to Article 5 , Paragraph 3 of the Act and the preventive regulations pursuant to Article 17 of the Act . 2. Emergency measures and contact with fire departments, etc. in the event of a disaster such as a fire 3. In the case of manufacturing facilities, etc. that appoint a separate person responsible for the safety of hazardous materials facilities, instructions to such person regarding the duties prescribed in each of the following subparagraphs; in the case of other manufacturing facilities, etc., the duties prescribed in each of the following subparagraphs. a. Inspections to maintain the location, structure, and facilities of manufacturing plants, etc., in compliance with the technical standards under Article 5, Paragraph 4 of the Act , and the recording and preservation of inspection status B. In the event of discovering abnormalities in the structure or facilities of the manufacturing plant, etc., contact relevant personnel and take emergency measures C. Contact fire departments, etc., and take emergency measures in the event of a fire or a significant risk of fire. D. Proper maintenance and management of measuring devices, control devices, safety devices, etc. in manufacturing facilities, etc. E. Maintenance and preservation of design documents, etc. regarding the location, structure, and facilities of manufacturing plants, etc., and management of affairs regarding the safety of the structure and facilities of manufacturing plants, etc. 4. Maintaining a cooperative system with relevant personnel of adjacent manufacturing facilities, etc., and other related facilities regarding the prevention of disasters such as fire and emergency measures. 5. Preparation and recording of logs regarding the handling of hazardous materials 6. Performing necessary supervision regarding safety in other work related to the handling of hazardous materials, such as loading containers containing hazardous materials onto vehicles and repairing hazardous materials facilities. Article 56 (Repositories, etc., where a single safety manager may be appointed multiple times) ①The term “repository prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 12, Paragraph 1, Subparagraph 3 of the Enforcement Decree refers to a repository falling under any of the following subparagraphs. < Amended May 26 , 2005; March 17, 2009; March 23, 2013; November 19, 2014; July 26, 2017> 1. 10 or fewer indoor storage units 2. 30 or fewer outdoor tank storage facilities 3. Indoor tank storage 4. Underground tank storage 5. Temporary tank storage 6. 10 or fewer outdoor storage units 7. Rock tank storage facilities with 10 or fewer ② In Article 12, Paragraph 1, Subparagraph 5 of the Enforcement Decree, the term “manufacturing facilities, etc. prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to a storage facility storing hazardous materials for supplying to the fixed refueling equipment of a ship refueling station and the said ship refueling station. <Amended Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017> Article 57 (Designation of Safety Management Agencies, etc.) ① A management agency capable of receiving and performing the duties of a hazardous materials safety manager pursuant to Article 40, Paragraph 1, Subparagraph 3 of the Special Measures Act on the Deregulation of Business Activities (hereinafter referred to as the “Safety Management Agency”) shall be an agency falling under any of the following subparagraphs andshall obtain designation from the Commissioner of the National Fire Agency after meeting the designation criteria for safety management agencies set forth in Annex 22. <Amended May 26, 2005; November 19, 2014; July 26, 2017> 1. A corporation registered as a tank tester pursuant to the provisions of Article 16 , Paragraph 2 of the Act 2. A corporation designated, approved, etc., as an agency performing safety management duties on behalf of others under other laws. ② Any person who wishes to be designated as an agency for safety management shall submit an application in the form of Annex 33 (including an application in electronic form) to the Commissioner of the National Fire Agency, attaching the documents specified in each of the following subparagraphs (including electronic documents). <Amended May 26, 2005; Aug. 3, 2006; Nov. 19, 2014; Jul. 26, 2017> 1. Deleted <Aug. 3, 2006> 2. List of Technical Personnel and Technical Qualifications 3. Documents proving the securing of an office 4. Equipment Holdings List ③ Upon receiving an application for designation pursuant to the provisions of Paragraph 2, the Commissioner of the National Fire Agency shall review the qualification requirements, technical personnel, and current status of facilities and equipment holdings, etc., and if deemed suitable, issue a Certificate of Designation as a Dangerous Goods Safety Management Agency in the form of Annex 34. Furthermore , regarding the technical qualification certificates of technical personnel submitted pursuant to the provisions of Paragraph 2, Subparagraph 2, the Commissioner shall issue the certificates with a statement indicating that the qualified person is a technical personnel of the safety management agency. <Amended Nov. 19, 2014; Jul. 26, 2017> ④ The Commissioner of the National Fire Agency shall provide necessary guidance and supervision to safety management agencies. <Amended Nov. 19, 2014; Jul. 26, 2017> ⑤ In the event of any change to the designated matters, a safety management agency shall submit a report on the change of hazardous materials safety management agency in the form of Annex 35 (including a report in electronic form) to the Commissioner of the National Fire Agency within 14 days from the date the cause for such change occurred, attaching the documents (including electronic documents) classified according to each of the following subparagraphs. <Amended May 26, 2005; Aug. 3, 2006; Nov. 19, 2014; Jul. 26, 2017; May 20, 2024> 1. In the case of changing the location of the business office, the corporate name, or the representative A. Deleted <Aug. 3, 2006> B. Designation of Dangerous Goods Safety Management Agency 2. In case of changing technical personnel A. List of Technical Personnel B. Technical qualifications of changed technical personnel 3. Deleted <May 20, 2024> ⑥ If a safety management agency intends to suspend, resume, or close its operations, it shall submit a Report on Suspension, Resumption, or Closure of Dangerous Goods Safety Management Agency (Form No. 35-2, including reports in electronic form) to the Commissioner of the National Fire Agency by attaching the Certificate of Designation as a Dangerous Goods Safety Management Agency (including electronic documents) no later than one day prior to the intended suspension, resumption, or closure. <Newly added May 20, 2024> ⑦ In the event that an application form under Paragraph 2 or a report under Paragraph 5, Subparagraph 1 is received, the public official in charge shall verify the contents through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act in lieu of receiving a certificate of corporate registration . <Newly added Aug. 3, 2006; Dec. 3, 2007; Nov. 8, 2010; May 20, 2024> Article 58 (Cancellation of Designation, etc. of Safety Management Agency) ① Pursuant to the provisions of Article 40, Paragraph 3 of the Special Measures Act on Deregulation of Business Activities, the Commissioner of the National Fire Agency may, when a safety management agency falls under any of the following subparagraphs, cancel its designation in accordance with the standards of Annex 2 , order the suspension of its operations for a period not exceeding six months, or require corrective action. However, if it falls under any of the provisions of Subparagraphs 1 through 3, the designation shall be canceled. <Amended May 26, 2005; November 19, 2014; July 26, 2017; May 20, 2024> 1. When designation was obtained through false or other fraudulent means 2. When the registration of a tank tester or the designation, approval, etc. of an agency performing safety management duties on their behalf under other laws is revoked 3. When lending the designation certificate to another person 4. When the designation criteria for safety management agencies specified in Annex 22 are not met 5. When failing to comply without justifiable reason with the guidance and supervision of the Commissioner of the Fire Service pursuant to the provisions of Article 57, Paragraph 4 6. When a report of change pursuant to Article 57, Paragraph 5 is not filed at least twice a year 6-2. When a report on suspension or resumption of business pursuant to Article 57, Paragraph 6 is not filed at least twice a year 7. When the technical personnel of the safety management agency fail to faithfully perform the safety management duties pursuant to the provisions of Article 59 ② When the Commissioner of the National Fire Agency designates, suspends the operations of, or revokes the designation of an agency for safety management, he/she shall publish such fact in the Official Gazette. <Amended Nov. 19, 2014; Jul. 26, 2017> ③ When the designation of a safety management agency is revoked, the designation certificate must be retrieved. Article 59 (Performance of Duties by Safety Management Agency) ① When a safety management agency is entrusted with the duties of a safety manager, it shall designate technical personnel who comply with the provisions of Article 13 and Annex 6 of the Enforcement Decree as the safety manager of the relevant manufacturing facility, etc., and have them perform the duties of the safety manager. ② In designating technical personnel as safety managers pursuant to the provisions of Paragraph 1, if a single technical personnel is designated as the safety manager for multiple manufacturing facilities, etc., the agency shall make the designation in accordance with the provisions of Article 12, Paragraph 1 of the Enforcement Decree and Article 56 of these Rules, or designate the number of manufacturing facilities, etc. managed within the scope where the duties of the safety manager can be faithfully performed on their behalf, so that it does not exceed 25. In this case, the person in charge of each manufacturing facility, etc. (excluding storage facilities storing 20 times or less of the designated quantity) shall designate a person holding a national technical qualification in the handling of hazardous materials or a person who has received safety training pursuant to Article 28, Paragraph 1 of the Act as a safety manager for each said facility, etc., to assist in the duties of the safety manager designated by the agency. <Amended Aug. 3, 2006; Mar. 17, 2009> ③ Technical personnel of a safety management agency designated as a safety manager pursuant to Paragraph 1 (hereinafter referred to as “technical personnel” in this paragraph) or persons designated as safety managers pursuant to Paragraph 2 shall participate in hazardous material handling operations and faithfully perform the duties of a safety manager pursuant to Article 15 of the Act and Article 55 of these Rules; and in cases where technical personnel do not participate in hazardous material handling operations, they shall conduct inspections pursuant to Subparagraph 3, Item ( a) of Article 55 and supervision pursuant to Subparagraph 6 of the same Article at least four times a month (twice a month in the case of storage facilities). <Amended Aug. 3, 2006; Mar. 17, 2009> ④ If a technical personnel of the safety management agency designated as a safety manager pursuant to the provisions of Paragraph 1 is temporarily unable to perform their duties due to travel, illness, or other reasons, the safety management agency shall designate other technical personnel belonging to the safety management agency as the safety manager to continue performing the duties of the safety manager. Article 60 (Application for Registration of Tank Tester, etc.) ①Any person who intends to register as a tank tester pursuant to Article 16, Paragraph 2 of the Act shall submit an application in the form of Annex 36 (including an application in the form of an electronic document) to the Mayor or Provincial Governor, attaching the documents specified in each of the following subparagraphs (including electronic documents). <Amended May 26, 2005; August 3, 2006; December 18, 2008; February 5, 2013> 1. Deleted <Aug. 3, 2006> 2. List of Technically Capable Personnel and Technical Qualifications 3. Specifications of Safety Performance Test Equipment 4. Data regarding equipment and test methods if a technical review has been received from the Institute. 5. One copy of the Permit for the Transfer and Use of Radioactive Isotopes or the Permit for the Transfer and Use of Radiation-Generating Devices pursuant to the Atomic Energy Safety Act 6. Documents proving the securing of an office ② Upon receipt of an application pursuant to Paragraph 1, the public official in charge shall verify the contents through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act in lieu of receiving a certificate of corporate registration. <Newly added Aug. 3, 2006; Dec. 3, 2007; Nov. 8, 2010> ③ When a City or Provincial Governor receives an application under Paragraph 1, if they recognize within 15 days that the application conforms to the registration standards under Article 14, Paragraph 1 of the Enforcement Decree, they shall issue a Certificate of Registration for Hazardous Material Tank Safety Performance Testers in the form of Annex 37 , and shall issue a technical qualification certificate of the technical personnel submitted under Paragraph 1 with a note indicating that said technical personnel are technical personnel of the relevant tank testing institution. <Amended Aug. 3, 2006; Sep. 15, 2009> Article 61 (Reporting of Changes, etc.) ① In the event that a tank testerchanges important matters falling under any of the following subparagraphs pursuant to the provisions of Article 16, Paragraph 3 of the Act , the tank tester shall submit a report in the form of Annex 38 (including a report in the form of an electronic document) to the Mayor or Provincial Governor, attaching the documents (including electronic documents) classified according to the following subparagraphs. <Amended May 26, 2005; August 3, 2006> 1. Change of business location: Documents proving use of the office and registration certificate for hazardous material tank safety performance testers 2. Change in Technical Capability: Qualifications of the technical personnel being changed and Registration Certificate of Hazardous Material Tank Safety Performance Testers 3. Change of Representative: Hazardous Material Tank Safety Performance Tester Registration Certificate 4. Change of trade name or designation: Hazardous Material Tank Safety Performance Tester Registration Certificate ② In the event that a report is received pursuant to Paragraph 1, the public official in charge shall verify the contents through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act in lieu of receiving a certificate of corporate registration. <Newly added Aug. 3, 2006; Dec. 3, 2007; Nov. 8, 2010> ③ When the Mayor or Provincial Governor accepts the report under Paragraph 1, they shall issue a new registration certificate or issue a submitted registration certificate with the changes recorded thereon, and issue a technical qualification certificate with the changed details recorded thereon. <Amended Aug. 3, 2006> Article 62 (Cancellation of Registration, etc.) ①The standards for cancellation of registration and suspension of business of a tank tester pursuant to the provisions of Article 16, Paragraph 5 of the Act are as set forth in Attached Table 2 . ② When a City or Provincial Governor receives the registration of a tank tester pursuant to Article 16, Paragraph 2 of the Act , or cancels the registration or suspends business pursuant to Article 16, Paragraph 5 of the Act , they shall publish such fact in the official gazette of the Special City, Integrated Special City, Metropolitan City, Special Self-Governing City, Province, or Special Self-Governing Province (hereinafter referred to as “City or Province”). <Amended Jan. 22, 2016; July 1, 2026> ③ When the Mayor or Provincial Governor cancels the registration of a tank tester, they shall retrieve the registration certificate. Chapter 7 Prevention Regulations Article 63 (Preparation of Preventive Regulations, etc.) ①Pursuant to Article 17, Paragraph 1 of the Act , persons concerned with a manufacturing facility, etc. falling under any of the subparagraphs of Article 15, Paragraph 1 of the Enforcement Decree shall prepare preventive regulations containing the matters of each of the following subparagraphs. <Amended July 17, 2015; July 2, 2024> 1. Matters concerning the duties and organization of persons responsible for the safety management of hazardous materials 2. Matters concerning a substitute for the safety manager in the event that the safety manager is unable to perform their duties due to travel, illness, etc. 3. Matters concerning the organization of the in-house fire brigade and the deployment of chemical fire trucks in cases where an in-house fire brigade must be established pursuant to the provisions of Article 18 of the Enforcement Decree 4. Matters concerning safety education and training for persons engaged in work related to the safety of hazardous materials 5. Matters concerning safety patrols of hazardous materials facilities and workplaces 6. Matters concerning the inspection and maintenance of hazardous materials facilities, firefighting facilities, and other related facilities 7. Matters concerning the operation or handling of hazardous materials facilities 8. Matters concerning standards for hazardous materials handling operations 9. In the case of transfer handling stations, matters concerning the supervision system for piping construction sites, such as the qualifications of the site manager for piping construction, and matters concerning ensuring the safety of piping when construction is performed outside the transfer handling station facilities surrounding the piping. 10. Matters concerning measures to be taken in the event of a disaster or other emergency 11. Matters concerning records regarding the safety of hazardous materials 12. Matters concerning the maintenance of documents and drawings specifying the location, structure, and facilities of manufacturing plants, etc. 13. Other matters necessary for the safe management of hazardous materials ② Preventive regulations may be prepared in conjunction with the safety and health management regulations pursuant to Article 25 of the Occupational Safety and Health Act , the process safety report pursuant to Article 44 of the same Act , or the chemical accident prevention and management plan pursuant to Article 23 of the Chemical Substances Control Act . <Amended May 26, 2005; Oct. 12, 2020; Dec. 31, 2024> ③ In the event that a person concerned with a manufacturing facility, etc. falling under any of the subparagraphs of Article 15, Paragraph 1 of the Enforcement Decree establishes or amends preventive regulations, he or she shall submit a Form for Submission of Preventive Regulations (Form No. 39) to the Mayor/Do Governor or the Fire Chief, attaching one copy of the established or amended preventive regulations. <Amended Sep. 15, 2009; Jul. 2, 2024> Article 63-2 (Evaluation of Implementation Status of Preventive Regulations) ① The evaluation of the implementation status of preventive regulations pursuant to Article 17, Paragraph 4 of the Act shall be conducted according to the classifications in each of the following subparagraphs. 1. Initial Assessment: Conducted in the year in which the third anniversary of the date of the initial submission of the preventive regulations falls, in accordance with the first part of Article 17, Paragraph 1 of the Act . 2. Regular evaluation: Conducted every four years based on the date of the initial evaluation or the most recent regular evaluation. However, if an ad hoc evaluation is conducted pursuant to Subparagraph 3, it shall be conducted every four years based on the date of the ad hoc evaluation. 3. Ad-hoc Assessment: Conducted when the Commissioner of the Fire Department deems it necessary to assess compliance with preventive regulations by persons responsible for or employees of manufacturing facilities, etc., in the event of an accident such as a hazardous material leak, fire, or explosion. ② When the Commissioner of the National Fire Agency conducts an evaluation pursuant to Paragraph 1, he/she may do so by means of a written inspection or an on-site inspection, taking into consideration the risks, etc., of manufacturing facilities, etc., in accordance with the latter part of Article 15, Paragraph 2 of the Enforcement Decree. In this case, on-site inspections shall be conducted only for manufacturing facilities, etc. in the high-risk group designated and notified by the Commissioner of the National Fire Agency. ③ When conducting an evaluation pursuant to Paragraph 1, the Commissioner of the Fire Department shall notify the persons in charge of the manufacturing facility, etc., of matters concerning the evaluation date, evaluation items, and detailed evaluation schedule by 30 days prior to the evaluation date (7 days prior in the case of Paragraph 1, Item 3). ④ The evaluation under Paragraph 1 shall be conducted on the detailed items of the preventive regulations under each subparagraph of Article 63 , Paragraph 1. However, in cases where an evaluation of the implementation status of a process safety report under Article 46, Paragraph 4 of the Occupational Safety and Health Act or an inspection of the implementation of a chemical accident prevention and management plan under Article 23-2, Paragraph 2 of the Chemical Substances Control Act has been received during the one year immediately preceding the date of the evaluation, and there are items that overlap with the said evaluation or inspection items, the evaluation of said items may be exempted. ⑤ When the Commissioner of the Fire Department has completed the evaluation of the implementation status of the prevention regulations in accordance with the provisions of paragraphs 1 through 4, he/she shall notify the persons in charge of the relevant manufacturing facility, etc. of the results. In this case, the Commissioner of the Fire Department may recommend that the persons in charge of the manufacturing facility, etc. implement necessary measures, etc., for fire prevention and the efficient execution of emergency measures in the event of a fire or other disaster. ⑥ In addition to the matters prescribed in paragraphs 1 through 5, necessary matters concerning the content, procedures, methods, etc. of the evaluation of the implementation status of preventive regulations shall be determined and announced by the Commissioner of the Fire Department . [This Article Newly Inserted July 2, 2024] Chapter 8 Regular Inspection Article 64 (Frequency of Periodic Inspections) Pursuant to the provisions of Article 18, Paragraph 1 of the Act , persons responsible for a manufacturing facility, etc. shall conduct a periodic inspection of the said manufacturing facility, etc. at least once a year. Article 65 (Periodic Inspection of Specific and Semi-Specific Outdoor Tank Storage Facilities) ① Pursuant to Article 18, Paragraph 1 of the Act , for outdoor tank storage facilities where the maximum quantity of liquid hazardous materials stored or handled is 500,000 liters or more (hereinafter referred to as “Specific and Semi-Specific Outdoor Tank Storage Facilities”), in addition to the periodic inspection under Article 64, a safety inspection regarding the structure, etc. of specific and semi-specific outdoor storage tanks (tank of specific and semi-specific outdoor tank storage facilities) must be conducted at least once within a period corresponding to any of the following subparagraphs (hereinafter referred to as “structural safety inspection”). However, if it is difficult to conduct a structural safety inspection within the relevant period due to the suspension of use of specific or semi-specific outdoor storage tanks, etc., an application for an extension of the inspection period (including an application by electronic document) may be submitted to the head of the competent fire station in accordance with Form No. 39-2; and the head of the fire station who receives such application may extend the inspection period within the range of one year (or the period of suspension of use in cases where the use of specific or semi-specific outdoor storage tanks has been suspended). <Amended May 26, 2005; December 18, 2008; December 29, 2017; October 12, 2020; July 13, 2021> 1. 12 years from the date of issuance of the Certificate of Consent to Completion Inspection pursuant to the installation permit for specific or quasi-specific outdoor tank storage facilities 2. 11 years from the date of the most recent periodic precision inspection under Article 70 , Paragraph 1, Subparagraph 1 3. In cases where safety measures have been taken for specific or quasi-specific outdoor storage tanks pursuant to Paragraph 2, and an application for an extension of the structural safety inspection period is filed pursuant to Article 71, Paragraph 2, and the said safety measures are recognized as appropriate, 13 years from the date of the most recent detailed periodic inspection under Article 70, Paragraph 1, Subparagraph 1 . ② The safety measures for specific and semi-specific outdoor storage tanks under Paragraph 1, Subparagraph 3 shall be any one of the following measures necessary to ensure the safety of specific and semi-specific outdoor storage tanks against corrosion, etc. <Amended Dec. 29, 2017; Jul. 13, 2021> 1. Measures in each of the following subparagraphs for preventing corrosion, etc. of specific and quasi-specific outdoor storage tanks a. Coating to prevent internal corrosion of specific or quasi-specific outdoor storage tanks [limited to glass particle (glass flake) coating or glass fiber reinforced plastic lining (lining: the application of chemicals, etc., to the contact surface of materials to prevent erosion and corrosion)] or measures equivalent to or better than these. B. Measures to prevent corrosion of the outer surfaces of the annular plate and bottom plate of specific and semi-specific outdoor storage tanks C. Measures to ensure that the thickness of the annular plate and bottom plate of specific and semi-specific outdoor storage tanks is maintained at an appropriate level D. Measures to ensure that repairs potentially affecting the structure of specific or quasi-specific outdoor storage tanks are not performed or that no deformation occurs. E. Measures to prevent the phenomenon of the structure sinking significantly unevenly (hereinafter referred to as “uneven settlement”). f. Measures to ensure sufficient ground bearing capacity while simultaneously ensuring sufficient safety against settlement G. Proper maintenance of the maintenance management system for specific and semi-specific outdoor storage tanks 2. Measures in each of the following subparagraphs regarding the storage and management of hazardous materials a. Proper management of components such as water that affect the occurrence of corrosion B. Measures to prevent the storage of significantly corrosive hazardous materials in specific and semi-specific outdoor storage tanks c. Measures to prevent changes in storage conditions that significantly affect the occurrence of corrosion D. The corrosion rate of the annular plates and bottom plates of specific and semi-specific outdoor storage tanks (a value obtained by dividing the decrease in the annular plates and bottom plates due to corrosion by the elapsed years of the plates) shall be 0.05 millimeters or less per year. E. Measures to prevent corrosion on the outer surfaces of annular plates and bottom plates of specific and semi-specific outdoor storage tanks f. Measures to ensure that the thickness of the annular plate and bottom plate of specific and semi-specific outdoor storage tanks is maintained at an appropriate level d. Measures to prevent repairs that may have a structural impact on specific or quasi-specific outdoor storage tanks, or to ensure that there is no deformation. Ah. Measures to prevent significant differential settlement Z. Measures to ensure sufficient ground bearing capacity while simultaneously ensuring sufficient safety against settlement. D. Proper maintenance of the maintenance management system for specific and semi-specific outdoor storage tanks ③ An application pursuant to the provisions of Paragraph 1, Subparagraph 3 shall be made using the application form in Annex 40 or Annex 41 . [Title amended Dec. 29, 2017] Article 66 (Contents of Periodic Inspections, etc.) Technical standards regarding the contents, methods, etc. of periodic inspections necessary to verify whether the location, structure, and facilities of manufacturing facilities, etc., comply with the technical standards under Article 5 , Paragraph 4 of the Act, and other matters necessary for inspections, shall be determined and announced by the Commissioner of the National Fire Agency . <Amended Nov. 19, 2014; Jul. 26, 2017> Article 67 (Persons Conducting Periodic Inspections) ① Persons responsible for a manufacturing facility, etc. shall,in accordance with the provisions of Article 18, Paragraph 1 of the Act , have a safety manager (limited to a person possessing the knowledge and skills regarding inspection methods prescribed and notified by the Commissioner of the National Fire Agency pursuant to Article 66 in the case of periodic inspections under the provisions of Article 65 ) ora hazardous materials transporter (limited to the case of mobile tank storage facilities). In this case, if a hazardous materials safety manager directly conducts a structural safety inspection of an outdoor tank storage facility,such inspection shall be conducted after equipping the facility with the personnel and equipment specified in Annex 7 of the Enforcement Decree necessary for the inspection. <Amended May 26, 2005; November 19, 2014; July 26, 2017> ② Notwithstanding Paragraph 1, the persons responsible for a manufacturing facility, etc. may request a safety management agency ( excluding periodic inspections of specific or quasi-specific outdoor tank storage facilities pursuant to Article 65 ) or a tank tester to conduct a periodic inspection. In this case, the safety manager of the relevant manufacturing facility, etc., shall attend the inspection site of the safety management agency or the tank tester. <Amended Mar. 17, 2009; Dec. 29, 2017; July 13, 2021> Article 68 (Recording and Maintenance of Periodic Inspections) ① Pursuant to Article 18, Paragraph 1 of the Act , persons concerned with a manufacturing facility, etc. shall record the matters in each of the following subparagraphs after a periodic inspection. <Amended July 13, 2021> 1. Name of the manufacturing facility, etc. where the inspection was conducted 2. Inspection Method and Results 3. Inspection Date 4. Name of the safety manager who conducted the inspection or the tank tester who conducted the inspection and the safety manager who observed the inspection ② The periodic inspection records pursuant to the provisions of Paragraph 1 shall be preserved for the periods classified in each of the following subparagraphs. 1. Records regarding structural safety inspections of outdoor storage tanks pursuant to the provisions of Article 65, Paragraph 1 : 25 years (30 years in cases subject to the period prescribed in Subparagraph 3 of the same paragraph) 2. Records of periodic inspections not falling under Item 1: 3 years Article 69 (Request for Periodic Inspection, etc.) ① When a person in charge of a manufacturing facility, etc.,has a tank tester conductthe periodic inspection under Article 18, Paragraph 1 of the Act in accordance with the provisions of Article 67, Paragraph 2 , he/she shall submit a request for periodic inspection in the form of Annex 42 to the tank tester. ② When the tank tester determines that the maintenance status of the tank, etc. is compliant as a result of conducting a periodic inspection, he/she shall issue a periodic inspection result report in the form of Annex 43 to the person in charge of the manufacturing facility, etc., within 10 days from the date of completion of the inspection, attaching a copy of the registration certificate of the hazardous material tank safety performance tester and the test report, and if it is not compliant, he/she shall notify the person in charge of the manufacturing facility, etc. of the matters to be improved. ③ Persons responsible for a manufacturing facility, etc., who have been notified of matters requiring improvement pursuant to the provisions of Paragraph 2, shall request a re-inspection after making the improvements. In this case, the tank tester shall record the matters requiring improvement (including the matters repaired directly by the tank tester, if such repairs were made) in the periodic inspection results report. ④ When a tank tester issues a report on the results of a periodic inspection pursuant to the provisions of Paragraph 2, they shall record the contents in the periodic inspection ledger and keep it for the period specified in each subparagraph of Paragraph 2 of Article 68 . Chapter 9 Periodic Inspection Article 70 (Timing of Periodic Inspection) ① Persons responsible for specific or quasi-specific outdoor tank storage facilities subject to periodic inspection pursuant to Article 18 , Paragraph 3 of the Act (hereinafter referred to as “periodic inspection”) shall undergo a detailed periodic inspection and an intermediate periodic inspection in accordance with the classifications in each of the following subparagraphs. However, if it is deemed inappropriate to conduct the periodic inspection at the relevant time due to the occurrence of a disaster or other emergency, the necessity for maintaining safety, or a change in usage conditions, the periodic inspection may be received at a time separately designated by the Chief of the Fire Station ex officio or upon the application of the person responsible. <Amended Mar. 17, 2009; Dec. 29, 2017; Oct. 12, 2020; July 13, 2021; Oct. 21, 2021> 1. Detailed periodic inspection: Once within any of the following periods a. 12 years from the date of issuance of the Certificate of Completion of Completion Inspection pursuant to the installation permit for specific or quasi-specific outdoor tank storage facilities B. 11 years from the date of the most recent detailed periodic inspection 2. Interim Regular Inspection: Once within any of the following periods a. 4 years from the date of issuance of the Certificate of Completion of Completion Inspection pursuant to the installation permit for specific or quasi-specific outdoor tank storage facilities B. 4 years from the date of the most recent detailed periodic inspection or interim periodic inspection ② Deleted <March 17, 2009> ③ Notwithstanding Paragraph 1, a person responsible for a specific or quasi-specific outdoor tank storage facility required to undergo a detailed periodic inspection pursuant to Paragraph 1, Subparagraph 1 (hereinafter referred to as “detailed periodic inspection”) may undergo the detailed periodic inspection together with the structural safety inspection pursuant to Article 65, Paragraph 1. <Amended Dec. 29, 2017; Oct. 12, 2020> Article 71 (Application for Periodic Inspection, etc.) ① Persons concerned with a specific or quasi-specific outdoor tank storage facility subject to periodic inspection shall submit an application in the form of Annex No. 44 (including an application in electronic form) to the Institute, attaching the documents specified in each of the following subparagraphs (including electronic documents), and pay the fee to the Institute pursuant to Subparagraph 8 of Annex 25. However, the documents specified in Subparagraphs 2 and 4 may be submitted at the time the periodic inspection is conducted. <Amended May 26, 2005; December 3, 2007; December 18, 2008; December 29, 2017; October 12, 2020; July 13, 2021> 1. Structural Equipment Specification Table ( Form No. 5) 2. Drawings regarding the location, structure, and facilities of the manufacturing plant, etc. 3. Certificate of Passing Completion Inspection 4. Documents regarding the repair history of baseboards, sideboards, roofboards, and openings ② Any person who intends to undergo a structural safety inspection within the period specified in Article 65, Paragraph 1, Subparagraph 3 shall submit an application form in the format of Annex No. 40 or Annex No. 41 (including an application form in electronic form) to the Institute together with the application for a periodic inspection in accordance with the main text of the part other than the subparagraphs of Paragraph 1. <Amended May 26, 2005; Oct. 12, 2020> ③ Any person who intends to change the timing of a periodic inspection pursuant to the proviso of the part other than the subparagraphs of Article 70, Paragraph 1, shall submit an application in the form of Annex 45 (including an application in the form of an electronic document) to the Chief of the Fire Station, attaching documents (including electronic documents) stating the reasons for the need to change the timing of the periodic inspection. <Amended May 26, 2005; Oct 12, 2020> ④ If the Institute, having conducted a periodic inspection in accordance with the standards prescribed and notified by the Commissioner of the National Fire Agency pursuant to Article 72, Paragraph 4, deems that the matters classified in each of the following subparagraphs are compliant, it shall issue a Certificate of Compliance with Periodic Inspection (Form No. 46) to the relevant person within 10 days from the date of completion of the inspection and prepare a report on the results to submit to the head of the fire station. <Amended Oct. 12, 2020; Jul. 13, 2021> 1. In cases subject to detailed periodic inspection: The following matters regarding specific and semi-specific outdoor storage tanks a. Matters concerning verticality and horizontality (excluding those concerning underground tanks) B. Matters concerning the thickness of the bottom plate (in the case of underground tanks, this refers to the leak prevention plate). C. Matters concerning welded parts D. Matters concerning the appearance of the structure and facilities 2. In cases subject to interim periodic inspection pursuant to Article 70, Paragraph 1, Subparagraph 2 : Matters concerning the external appearance of the structure and facilities of specific and semi-specific outdoor storage tanks ⑤ If the Institute finds the regular inspection to be non-compliant, it shall notify the applicant and the Fire Station Chief of the matters requiring improvement. The relevant parties who have received such notification shall resubmit an application in the form of Annex 44 to the Institute after completing the improvements. <Amended Dec. 18, 2008; Oct. 12, 2020; May 20, 2024> ⑥ Persons related to a manufacturing facility, etc. that has undergone a periodic inspection and the technical institute that conducted the periodic inspection shall retain documents related to the periodic inspection, such as the Certificate of Consent to the Periodic Inspection, until the next periodic inspection of the relevant manufacturing facility, etc. <Amended Dec. 18, 2008; Oct. 12, 2020; Jul. 13, 2021> Article 72 (Method of Periodic Inspection, etc.) ① Periodic inspections shall be conducted using inspection methods suitable for verifying safety, taking into consideration the location, structure, and characteristics of facilities of specific and quasi-specific outdoor tank storage facilities. <Amended Dec. 29, 2017; Jul. 13, 2021> ② When a person responsible for a specific or quasi-specific outdoor tank storage facility applies for a detailed periodic inspection after having inspected in advance the matters specified in each item of Article 71, Paragraph 4, Subparagraph 1 during the structural safety inspection pursuant to Article 65, Paragraph 1 , the detailed periodic inspection regarding such matters shall be conducted by selecting and inspecting an arbitrary part from the entire scope of the inspection. <Amended Dec. 29, 2017; Oct. 12, 2020> ③ When conducting a tank safety performance inspection pursuant to a permit for modification of a specific outdoor tank storage facility, if a detailed periodic inspection is carried out concurrently and the scopes of the inspections overlap, either inspection within the relevant scope shall be omitted. <Amended Oct. 12, 2020> ④ The inspection methods and judgment criteria pursuant to the provisions of Paragraphs 1 through 3, and other matters necessary for the implementation of periodic inspections, shall be determined and announced by the Commissioner of the National Fire Agency . <Amended Nov. 19, 2014; Jul. 26, 2017; Oct. 12, 2020> Chapter 10 In-house Fire Brigade Article 73 (General Handling Stations Excluded from Installation of Private Fire Brigades) In the proviso to Article 18, Paragraph 1, Subparagraph 1 of the Enforcement Decree, the term “general handling station prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to a general handling station falling under any of the following subparagraphs. <Amended May 26, 2005; Aug. 3, 2006; Mar. 17, 2009; Mar. 23, 2013; Nov. 19, 2014; Jul. 26, 2017; Oct. 12, 2020> 1. General handling facilities that consume hazardous materials using boilers, burners, or other similar devices 2. General handling facilities that inject hazardous materials into mobile storage tanks or other similar devices 3. General handling station for transferring hazardous materials into containers 4. General handling facilities that handle hazardous materials using hydraulic systems, lubricating oil circulation systems, or other similar devices 5. General handling facilities subject to the Mining Safety Act Article 74 (Special Provisions for Organization of In-House Fire Brigade) In cases where two or more business establishments have entered into an agreement on mutual support pursuant to the proviso of Article 18, Paragraph 3 of the Enforcement Decree, all such business establishments shall be regarded as a single business establishment, and the total quantity of Class 4 hazardous materials handled at manufacturing or handling facilities shall be deemed as the maximum quantity of Class 4 hazardous materials handled at a single business establishment, thereby determining the number of chemical fire trucks and in-house fire brigade members in accordance with the provisions of the main text of the said paragraph. In this case, the in-house fire brigade of each business establishment that has entered into an agreement on mutual support shall have at least half the number of chemical fire trucks as stipulated in the main text of Article 18, Paragraph 3 of the Enforcement Decree, and at least five in-house fire brigade members for each chemical fire truck. Article 75 (Standards for Chemical Firefighting Vehicles, etc.) ① The standards for firefighting capacity and equipment to be provided for chemical firefighting vehicles (including explosion-proof chemical vehicles and decontamination vehicles) pursuant to the provisions of the Note in Table 8 of the Enforcement Decree are as set forth in Table 23 . ② The number of chemical firefighting vehicles that discharge blasting solution shall be at least two-thirds of the number of chemical firefighting vehicles as stipulated in Article 18, Paragraph 3 of the Enforcement Decree. Chapter 11 Questioning, Examination, etc. Article 76 (Fire Inspection Report) When a public official conducting entry, inspection, etc., pursuant to Article 22, Paragraph 1 of the Act discovers matters that do not comply with the Act or any order or ordinance based on the Act, he/she shall provide a copy of the Fire Inspection Report for a Dangerous Goods Manufacturing Facility, etc., in the form of Annex 47, containing the details thereof , to the person in charge of the manufacturing facility, etc., at the site of inspection. However, this shall not apply in cases where a mobile tank storage facility in motion on a road is stopped for inspection. Article 77 (Matters to be Notified Regarding Mobile Tank Storage Facilities) When a mayor or provincial governor, the head of a fire department, or a fire station chief issues an order to a person in charge of a mobile tank storage facility to comply with standards for the storage or handling of hazardous materials pursuant to the provisions of Article 26, Paragraph 3 of the Act , they shall notify the fire station chief who granted the permit for the said mobile tank storage facility of the following matters: 1. The Mayor/Provincial Governor, Head of Fire Department, or Fire Station Chief who issued the order 2. Name, designation, and address of the person who received the order 3. Installer, installation location, and permit number for installation or modification of the mobile tank storage facility related to the order 4. Details of the violation 5. Contents of the Order and Matters of Its Implementation 6. Other matters that the Mayor/Do Governor, Head of the Fire Department, or Fire Station Chief who issued the order deems necessary to notify. Chapter 12 Supplementary Provisions Article 78 (Safety Education) ① Safety education shallbe classified into education for persons specified in each subparagraph of Article 28 , Paragraph 1 of the Act and Article 20 of the Enforcement Decree (hereinafter referred to as “practical training”) and education for persons specified in Article 22, Paragraph 1, Subparagraph 1, Items ( a ) and (b) of the Enforcement Decree (hereinafter referred to as “instructional training”). <Amended May 20, 2024> ② The course and duration of the safety education under Paragraph 1 and other matters concerning the implementation of the education are as set forth in Attached Table 24. <Amended May 20, 2024> ③ The Institute or the Korea Fire Safety Institute pursuant to Article 40 of the Framework Act on Firefighting (hereinafter referred to as the “Institute”) shall formulate an annual education implementation plan and obtain approval from the Commissioner of the National Fire Agency by the end of the year preceding the year in which the education is conducted, and shall report the results of the education conducted for the relevant year to the Commissioner of the National Fire Agency by January 31 of the year following the year in which the education was conducted. <Amended Aug. 2, 2016; Jul. 26, 2017; Jan. 3, 2019> ④ The Head of the Fire Department shall notify the Safety Institute of the status of persons subject to practical training within their jurisdiction by the end of October each year and shall provide guidance and supervision regarding safety training conducted by the Safety Institute within their jurisdiction. <Amended Jan. 3, 2019> Article 79 (Fees, etc.) ①Fees and education expenses pursuant to Article 31 of the Act shall be as set forth in Attached Table 25 . ② Fees or training expenses pursuant to the provisions of Paragraph 1 shall be paid to the agency directly performing the duties of the relevant permit, etc. at the time of application or notification; provided, however, that fees payable to the Mayor/Do Governor or the Fire Chief shall be paid using revenue stamps of the relevant Mayor/Do. Provided, however, that the Mayor/Do Governor or the Fire Chief may allow such payment to be made via electronic money, electronic payment, etc., using an information and communications network. Article 80 (Review of Regulations) The Commissioner of the Fire Department shall review the validity of the evaluation methods, etc. regarding the implementation status of the preventive regulations under Article 63-2 every five years starting from January 1, 2025 (meaning before January 1 of every fifth year) and take measures such as improvements. [This Article Newly Inserted July 2, 2024] ADDENDA <Ministry of Government Administration and Home Affairs Decree No. 242, July 7, 2004> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Special Provisions Concerning the Application of Facility Standards for Petroleum Sales Outlets Established Previously)  ① Petroleum sales outlets established under the former Fire Prevention Act at the time of the enforcement of this Rule that have indoor tank storage facilities shall be deemed to have been licensed as general transfer outlets pursuant to the provisions of Annex 16 VII of this Rule. ② When a mayor or provincial governor, the head of a fire department, or the head of a fire station recognizes that a petroleum sales handling facility established under the former Fire Prevention Act that performs the work of transferring hazardous materials into mobile storage tanks does not comply with the standards for general handling facilities under this Rule and that repair, modification, or relocation of its location, structure, or facilities is necessary for fire prevention, they may issue a necessary order pursuant to the provisions of Article 14, Paragraph 2 of the Act. Article 3 (Special provisions regarding the first periodic inspection of manufacturing facilities, etc.)  Notwithstanding the provisions of the main text of Article 64, persons responsible for manufacturing facilities, etc. that received installation permits under the former Fire Prevention Act at the time of enforcement of this Rule shall conduct the first periodic inspection of said manufacturing facilities, etc. by May 29, 2005. Article 4 (Special provisions regarding structural safety inspections and periodic inspections of specific outdoor tank storage facilities)  ① The first structural safety inspection and periodic inspection of a specific outdoor tank storage facility for which a leak inspection has been conducted pursuant to the provisions of Article 10-4, Paragraph 1 of the Enforcement Rule of the Fire Prevention Act, Ministry of Home Affairs Decree No. 667 (amended on December 29, 1995) shall be conducted within 7 years from the date the said leak inspection was conducted. ② The first structural safety inspection under this Rule for a specific outdoor tank storage facility that has undergone a structural safety inspection pursuant to Article 17-2 of the former Fire Prevention Act and Article 10-5 of the Enforcement Rule of the same Act (hereinafter referred to as “former structural safety inspection” in this paragraph) must be carried out within 11 years from the date of passing the former structural safety inspection (in cases where the inspection period was extended pursuant to the Enforcement Rule of the former Fire Prevention Act, the inspection period prior to the extension; hereinafter the same applies in this paragraph), and the first periodic inspection must be received within one year before or after the date marking 10 years from the date of passing the former structural safety inspection. ③ The extension of the period for conducting structural safety inspections pursuant to the provisions of Paragraphs 1 and 2 shall be in accordance with the provisions of the proviso to Paragraph 1 of Article 65. ④ Changes to the timing of periodic inspections under the provisions of Paragraphs 1 and 2 shall be in accordance with the provisions of the proviso to Paragraph 1 of Article 70 and Paragraph 3 of the same article. Article 5 (Special provisions regarding the first periodic inspection of specific outdoor tank storage facilities)  Persons concerned with a specific outdoor tank storage facility that received an installation permit under the former Fire Prevention Act at the time of enforcement of this rule shall undergo the first periodic inspection of the said specific outdoor tank storage facility within 12 years from the date of passing the completion inspection. Article 6 (Transitional Measures Concerning the Issuance of Certificate of Completion Inspection)  Any person who has installed a manufacturing facility, etc. under the former Fire Prevention Act at the time of enforcement of this Rule shall return the former permit for the installation of the manufacturing facility, etc. by December 31, 2004, and receive a certificate of completion inspection in the form of Annex No. 24 or Annex No. 25. Article 7 (Transitional Measures Concerning Outdoor Tank Storage Facilities with Previously Installed Underground Tanks)  ① Persons responsible for outdoor tank storage facilities with underground tanks pursuant to the provisions of Article 30 and Annex 6 XII that were already installed at the time of the enforcement of this Rule shall submit a facility management plan regarding the installation status and maintenance of the said outdoor tank storage facility to the competent authority having jurisdiction over the installation location of the said outdoor tank storage facility by December 31, 2004. It must be submitted to the fire chief. ② If the person responsible for an outdoor tank storage facility pursuant to the provisions of Paragraph 1 submits a facility management plan regarding the installation status and maintenance of the said outdoor tank storage facility, it shall be deemed to have received the permit pursuant to the provisions of Article 6, Paragraph 1 of the Act and the completion inspection pursuant to the provisions of Article 9 of the Act. Article 8 (Transitional Measures Concerning Safety Education)  Persons who have received education on the handling of hazardous materials pursuant to the proviso of Article 20, Paragraph 1 of the former Fire Prevention Act at the time of the enforcement of this Rule shall be deemed to have received the instructional education for hazardous materials transporters under this Rule. Article 9 (Transitional Measures Concerning Safety Management Agencies)  Any person who was designated as a safety management agency pursuant to the provisions of the former Enforcement Rule of the Fire Prevention Act at the time of the enforcement of this Rule shall be deemed to have been designated as a safety management agency pursuant to the provisions of Article 57 of this Rule. Article 10 (Relationship with Other Laws and Regulations)  Where, at the time of the enforcement of this Rule, other laws and regulations refer to the former Enforcement Rules of the Fire Prevention Act or the Rules on Technical Standards for Firefighting, or their provisions, and there are corresponding provisions in this Rule, it shall be deemed that this Rule or the relevant provisions of this Rule have been referred to in place of the former provisions. ADDENDA <Ministry of Government Administration and Home Affairs Decree No. 283, May 26, 2005> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of Government Administration and Home Affairs Decree No. 340, Aug. 3, 2006> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of Government Administration and Home Affairs Decree No. 405, Dec. 3, 2007> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of Government Administration and Home Affairs Decree No. 407, Dec. 13, 2007> (Partial Amendment to the Enforcement Rules of the Act on Contracts to Which Local Governments Are a Party, etc. for the Expansion of Joint Use of Administrative Information) This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of Public Administration and Security Decree No. 47, Dec. 18, 2008> (Enforcement Rule of the Act on the Promotion of the Firefighting Industry) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Amendment of Other Laws)  ① through ④ Omitted ⑤ Part of the Enforcement Rules of the Dangerous Goods Safety Management Act is amended as follows. In Article 6, subparagraph 10, “the Korea Fire Testing Corporation pursuant to Article 45 of the Framework Act on Firefighting (hereinafter referred to as the “Corporation”)” shall be changed to “the Korea Fire Industry Technology Institute pursuant to Article 14 of the Act on the Promotion of the Fire Industry (hereinafter referred to as the “Institute”)”, and “Corporation” shall be changed to “Institute”. In the main text of Article 9, Paragraph 1 (excluding the numbered items), Article 16, the main text of Article 18, Paragraph 1 and Paragraph 2 of the same article, the main text of Article 19, Paragraph 1 (excluding the numbered items), the main text of Article 51, Paragraph 2, Article 65, Paragraph 1, Item 3, the main text of Article 71, Paragraph 1 (excluding the numbered items), and Article 78, Paragraph 3, “Corporation” shall be changed to “Institute of Technology”. In the part other than the subparagraphs of Article 9, Paragraph 2, Article 12, Paragraph 5, Article 13, Paragraph 2, Article 14, Paragraph 2, Article 15, Paragraph 2, Article 18, Paragraph 5, Article 19, Paragraph 2, Article 51, Paragraph 3, and Article 71, Paragraphs 4 and 6, “the Corporation” shall be replaced with “the Institute of Technology”. In Article 19, Paragraph 1, Subparagraph 2, replace “Corporation” with “Institute of Technology” and “the Corporation” with “the Institute of Technology”; in Article 20, Subparagraph 4, Items (b) and (c), replace “the Corporation” with “the Institute of Technology”; in Article 51, Paragraph 4, replace “the President of the Corporation” with “the Director of the Institute of Technology”; in Article 60, Paragraph 1, Subparagraph 4, replace “from the Corporation” with “from the Institute of Technology”; and in Article 71, Paragraph 5, replace “the Corporation” with “the Institute of Technology” and “the Corporation” with “the Institute of Technology”. In the educational institution column of practical training in Item 1 of Annex 24, Item 2 (b) of the same Annex, and Items 4 and 5 of the same Annex, “Corporation” shall be changed to “Technology Institute”, and in the proviso of the part other than each item of Item 4 of Annex 25, “Corporation” shall be changed to “Technology Institute”. In Item 7(a) of the remarks column of Form No. 1, replace “the Korea Fire Testing Corporation pursuant to Article 45 of the Fire Protection Act” with “the Korea Fire Industry Technology Institute pursuant to Article 14 of the Act on the Promotion of the Fire Industry”; in Item 9 of the attached documents column of the same form, replace “the Korea Fire Testing Corporation pursuant to the provisions of Article 45 of the Fire Protection Act” with “the Korea Fire Industry Technology Institute pursuant to Article 14 of the Act on the Promotion of the Fire Industry” and replace “Corporation” with “Institute”; and in Item 8(a) of the remarks column of Form No. 16, replace “the Korea Fire Testing Corporation pursuant to Article 45 of the Fire Protection Act” with “the Korea Fire Industry Technology Institute pursuant to Article 14 of the Act on the Promotion of the Fire Industry”; and in Item 10 of the attached documents column of the same form, replace “the Korea Fire Testing Corporation pursuant to the provisions of Article 45 of the Fire Protection Act” with “the fire industry "The Korea Fire Industry Technology Institute pursuant to Article 14 of the Act on Promotion" shall be changed to "the Corporation" and "the Institute" to "the Institute". In the processing agency section on the back of Form No. 17-2, Form No. 18, Form No. 20, Form No. 22, Form No. 30, Form No. 40, Form No. 41, and Form No. 44, “Korea Fire Safety Testing Corporation” shall be changed to “Korea Fire Industry Technology Institute”. In Forms No. 21, No. 24, No. 31, and No. 46, “President of the Korea Fire Testing Corporation” shall be changed to “President of the Korea Fire Industry Technology Institute”. ADDENDA <Ministry of Public Administration and Security Decree No. 70, Mar. 17, 2009> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Application)  The amended provisions of Items 6 and 16 of Annex 8 I shall apply starting from the first application for a permit under Article 6, Paragraph 1 of the Dangerous Goods Safety Management Act after the enforcement of this Rule. ADDENDA <Ministry of the Interior and Safety Decree No. 105, Sep. 15, 2009> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 170, Nov. 8, 2010> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 297, May 31, 2012> (Partial Amendment to the Enforcement Rules of the Act on the Management of Public Records, etc. for the Protection of Personal Information) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Transitional Measures Regarding Amendment of Forms)  Forms under the previous regulations at the time of enforcement of this rule may be used together with the forms under this rule until August 31, 2012. ADDENDA <Ministry of the Interior and Safety Decree No. 345, Feb. 5, 2013> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Applicability to the Expansion of Permissions for Changes to Manufacturing Facilities, etc.)  The amended provisions of Annex 1-2 shall apply from the time of the enforcement of this rule to change the location, structure, or facilities of a manufacturing facility, etc. Article 3 (Applicability to changes in standards, etc. regarding the location, structure, and facilities of outdoor tank storage facilities, etc.)  The amended provisions of Annex 6, Annex 13, and Annex 18 shall apply from the time an application for installation permit or modification permit is made pursuant to Article 6, Paragraph 1 of the Act after the enforcement of this Rule. Article 4 (Applicability to Safety Education for Technical Personnel of Tank Testers)  The amended provisions of Annex 24 shall apply to persons who newly become technical personnel of a tank tester after the enforcement of this rule. ADDENDA <Ministry of Security and Public Administration Decree No. 3, Mar. 23, 2013> (Enforcement Rule for the Organization of the National Fire Agency and its Affiliated Agencies) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2  omitted Article 3 (Amendment of Other Laws)  ① through ⑦ Omitted ⑧ Part of the Enforcement Rules of the Dangerous Goods Safety Management Act is amended as follows. In Article 3, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, Paragraph 3 (excluding the numbered items), Paragraph 4 of the same article, Article 8, Article 11, Paragraph 1, Paragraph 2 (excluding the numbered items), Article 12, Paragraphs 1 through 4, Article 13, Paragraph 1 (excluding the numbered items), Article 14, Paragraph 1 (excluding the numbered items), Article 15, Paragraph 1, Article 18, Paragraph 6, Article 51, Paragraph 1, Article 54 (excluding the numbered items), Article 56, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, and Article 73 (excluding the numbered items), “Ordinance of the Ministry of Public Administration and Security” shall be changed to “Ordinance of the Ministry of Safety and Security”. Omit ⑨ through ⑫ ADDENDA <Ministry of Security and Public Administration Decree No. 73, June 23, 2014> This rule shall take effect from the date of its promulgation. ADDENDA <Prime Minister's Decree No. 1105, Nov. 19, 2014> (Enforcement Rule for the Organization of the Ministry of Public Safety and Security and Its Affiliated Agencies) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, among the Ministerial Ordinances amended pursuant to Article 6 of the Addenda, the parts amending Prime Ministerial Ordinances or Ministerial Ordinances that were promulgated prior to the enforcement of this Rule but whose effective date has not yet arrived shall enter into force on the respective effective dates of the said Prime Ministerial Ordinances or Ministerial Ordinances. Articles 2 through 5  omitted Article 6 (Amendment of Other Laws)  ① through ㉒ Omitted 23 Part of the Enforcement Rules of the Dangerous Goods Safety Management Act is amended as follows. In Article 3, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, Paragraph 3 (excluding the numbered items), Paragraph 4 of the same article, Article 8, Article 11, Paragraph 1, Paragraph 2 (excluding the numbered items), Article 12, Paragraphs 1 through 4, Article 13, Paragraph 1 (excluding the numbered items), Article 14, Paragraph 1 (excluding the numbered items), Article 15, Paragraph 1, Article 18, Paragraph 6, Article 51, Paragraph 1, Article 54 (excluding the numbered items), Article 56, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, and Article 73 (excluding the numbered items), “Ordinance of the Ministry of Public Administration and Security” shall be changed to “Ordinance of the Prime Minister.” In Article 5, Paragraph 2; Article 16; Article 44; Article 45; the part other than the subparagraphs of Article 57, Paragraph 1; the part other than the subparagraphs of Article 57, Paragraph 2; Paragraphs 3 and 4; the part other than the subparagraphs of Article 57, Paragraph 5; the main text of Article 58, Paragraph 1, the part other than the subparagraphs; Subparagraph 5 of the same Paragraph; Paragraph 2 of the same Article; Article 66; the first part of Article 67, Paragraph 1; Article 71, Paragraph 4; Article 72, Paragraph 4; and Article 78, Paragraphs 1 and 3, “Commissioner of the National Fire Agency” shall be changed to “Minister of Public Safety and Security”. The violation column of Subparagraph 2, Item (b) (5) of Annex 2; the first part of Subparagraph 2 of IV of Annex 4; the part other than the detailed items of Subparagraph 1) and Subparagraph 2) of Subparagraph 2) of IV of Annex 6, and Subparagraphs (a) and (b) of Subparagraph 2), Subparagraphs (c), (d), and (f) of Subparagraph 2); Subparagraphs 3 and 4 of the same Table IV; the part other than the detailed items of Subparagraph 1) and Subparagraph 2) of Subparagraph 3 of the same Table V, and Subparagraphs (a) and (b) of Subparagraph 2), Subparagraphs (c) through (e) of Subparagraph 4 of the same Table V; Subparagraphs 1, 2, and 3, Item (b) of the same Table VI; Subparagraph 2, Item (a) of the same Table VII, the latter part of Subparagraph (b) of Subparagraph 2, Item (c) of Subparagraph 2; the latter part of the part other than the subparagraphs of Subparagraph 3 of the same Table VII; Subparagraph 4 of the same Table VII; Subparagraphs (b) and (c) of Subparagraph 2 of the same Table VIII; the latter part of Subparagraph 3 of the same Table VIII; the same Table VIII No. 4, the part excluding the sub-items of Item 2(a) of Table XII, Item 2 of the same sub-item (b), (d), (e), (f), (f), Item 2 of the same sub-item (e), Item 4)(a) through (d), the main text of Item (j) of the same sub-item, Item (j) of the same sub-item, the main text of Item (k) of the same sub-item, Table XII No. 3, the latter part of Item 6 of Annex 8 I, the latter part of Item 2(b)(1)(a) of Table II of the same sub-item, Table II No. 6, Annex 10 II No. 1(a), Table IV No. 2, Table V No. 3, Annex 13 V No. 1(h), the part excluding the sub-items of Item V No. 3 of the same table, Table VII No. 1, Annex 15 II No. 5, Items 5(b), 6(b), 20(b), and 21 of Table IV, Table V No. 5 Appendix 18 IV, Item 5, Subparagraph (g) 3), Appendix 18 V, Item 1, Subparagraph (a); Appendix 19 I, Item 3, Subparagraph (a) proviso, proviso of the part other than the sub-item of Subparagraph (b) 6), Appendix 19 I, Items 4 and 5 and Item 6, Subparagraph (a) main text and proviso, Subparagraph (b) main text and proviso; Appendix 19 II, Item 2, Subparagraph (g) and Item 6, Subparagraph (b); Appendix 19 II, Item 8, proviso of the part other than the items; Appendix 19 II, Item 13, proviso of the part other than the items; Subparagraph (d) of the same item; Appendix 24, Item 5, the first part other than the table; the fee column for foundation/ground inspection to double-wall tank inspection in the bottom table of Appendix 25, Item 3, Subparagraph (a); the fee column for foundation/ground inspection to double-wall tank inspection in the bottom table of Subparagraph (b) 3; the proviso of the part other than the items of Item 4 4 3; and “Commissioner of the National Fire Agency” in Items 8 through 10 3, respectively It shall be the “Minister of Public Safety and Security”. In the proviso to Item 3) of Subparagraph 2 of Annex 6 XII, “National Fire Agency” shall be changed to “Minister of Public Safety and Security”. In Form No. 33, “Commissioner of the National Fire Agency” shall be changed to “Minister of Public Safety and Security,” and in the processing procedure section of the same form, “Commissioner of the National Fire Agency (Department in charge of hazardous materials)” shall be changed to “Ministry of Public Safety and Security (Department in charge of hazardous materials).” In Form No. 34, “Minister of Fire and Disaster Prevention” shall be changed to “Minister of Public Safety and Security”. In Form No. 35, “Commissioner of the National Fire Agency” shall be changed to “Minister of Public Safety and Security,” and in the processing procedure section of the same form, “Commissioner of the National Fire Agency (Department in charge of hazardous materials)” shall be changed to “Ministry of Public Safety and Security (Department in charge of hazardous materials).” omitted from 24 to 46 ADDENDA <Prime Minister's Decree No. 1178, July 17, 2015> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, the amended provisions of Item 21 of Annex 6 VI shall enter into force on January 1, 2016. Article 2 (Applicability to the Location, Structure, and Equipment, etc. of Manufacturing Plants, etc.)  The amended provisions of Annex 6 VI No. 21, Annex 6 IX No. 1, Annex 8 I Nos. 8 and 9, and Annex 13 IV No. 2 shall apply from the time an application for installation or modification of a manufacturing plant, etc. is made after the enforcement of this rule. Article 3 (Transitional Measures concerning Standards for Drafting Preventive Regulations)  In the case of a manufacturing facility, etc., where a person concerned is required to establish preventive regulations, and the facility, etc. has established and submitted preventive regulations at the time of enforcement of this Rule, the preventive regulations must be changed to comply with the amended provisions of Article 63, Paragraph 1, Subparagraph 4 by December 31, 2016. ADDENDA <Prime Minister's Decree No. 1243, Jan. 22, 2016> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, the amended provisions of Article 26, subparagraph 1 and Annex 3 shall enter into force on February 1, 2016, and the amended provisions of Article 26, subparagraph 2 and Annex 3-2 shall enter into force on January 1, 2019. Article 2 (Transitional Measures Concerning Criteria for Imposing Surcharges)  Notwithstanding the amended provisions of Article 26, Annex 3, and Annex 3-2, the former provisions shall apply to the criteria for imposing surcharges for violations committed prior to February 1, 2016. ADDENDA <Prime Minister's Decree No. 1247, Jan. 27, 2016> (Partial Amendment to the Enforcement Rules of the Act on 119 Rescue and Emergency Medical Services, etc. for the Batch Amendment of Legal Forms) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Transitional Measures Regarding Forms)  Forms under the previous regulations at the time of enforcement of this rule may be used together with the forms under this rule for three months after enforcement of this rule. ADDENDA <Prime Minister's Decree No. 1306, Aug. 2, 2016> This rule shall enter into force on the date of its promulgation. However, the amended provisions of Subparagraph III, Item 2 of Annex 19 shall enter into force on January 1, 2017. ADDENDA <Ministry of the Interior and Safety Decree No. 2, July 26, 2017> (Enforcement Rule for the Organization of the National Fire Agency and its Affiliated Agencies) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, among the Decrees of the Prime Minister amended pursuant to Article 3 of the Addenda, the parts amending Decrees of the Prime Minister that were promulgated prior to the enforcement of this Decree but whose enforcement date has not yet arrived shall enter into force on the respective enforcement dates of those Decrees. Article 2  omitted Article 3 (Amendment of Other Laws)  ① through ⑬ Omitted 14. Part of the Enforcement Rules of the Dangerous Goods Safety Management Act is amended as follows. In Article 3, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, Paragraph 3 (excluding the numbered items), Paragraph 4 of the same article, Article 8, Article 11, Paragraph 1, Paragraph 2 (excluding the numbered items), Article 12, Paragraphs 1 through 4, Article 13, Paragraph 1 (excluding the numbered items), Article 14, Paragraph 1 (excluding the numbered items), Article 15, Paragraph 1, Article 18, Paragraph 6, Article 51, Paragraph 1, Article 54 (excluding the numbered items), Article 56, Paragraph 1 (excluding the numbered items), Paragraph 2 of the same article, and Article 73 (excluding the numbered items), the term “Prime Minister’s Decree” shall be changed to “Ministry of the Interior and Safety Decree”. In Article 5, Paragraph 2; Article 16; Article 44; Article 45; Article 51, Paragraph 5; the part other than the subparagraphs of Article 57, Paragraph 1; the part other than the subparagraphs of Article 57, Paragraph 2; Paragraphs 3 and 4 of Article 57; the part other than the subparagraphs of Article 58, Paragraph 5; the main text of the part other than the subparagraphs of Article 58, Paragraph 1; Subparagraph 5 of the same Paragraph; Paragraph 2 of Article 58; Article 66; the first part of Article 67, Paragraph 1; Article 71, Paragraph 4; Article 72, Paragraph 4; and Article 78, Paragraphs 1 and 3, “Minister of Public Safety and Security” shall be changed to “Commissioner of the Fire Department”. Appendix 2, Subparagraph 2, Item (b) (5); Appendix 4, IV, Item 2, first part; Appendix 6, IV, Subparagraph 2, Item (b) 1), part other than (a) through (c) of Subparagraph 2), (a) and (b) of Subparagraph 2), (c), (d), and (f) of Subparagraph 4; Appendix IV, Item 3, Item 4; Appendix V, Subparagraph 3, Item (b) 1), part other than (a) and (b) of Subparagraph 2), (a) and (b) of Subparagraph 2), (c) through (e) of Subparagraph 2; Appendix V, Item 4; Appendix VI, Items 1 and 2; Appendix VI, Subparagraph 3, Item (b); Appendix VI, Item 21; Appendix VII, Subparagraph 2, Items (a) through (c); the latter part other than each item of Appendix VII, Item 4; Appendix VIII, Subparagraph 2, Items (b) and (c); The latter part of Item 3 in VIII, Item 4 in VIII, Item 3 in Table IX, the part other than Items 1) and 2) of Subparagraph (a) of Item 2 in Table XII, Subparagraph (d) 2)b), d), e), f), Subparagraph (e) 2), the proviso to Subparagraph 3), Subparagraph 4)a) through d), the main text of Subparagraph (j), Subparagraph (j), the main text of Subparagraph (k), Item 3 in Table XII, the latter part of Item 6 in Appendix 8 I, the latter part of Subparagraph (b) 1)a) of Item 2 in Table II, Item 6 in Table II, Item 1 subparagraph (a) in Appendix 10 II, Item 2 in Table IV, Items 1 and 2 in Table V, Subparagraph (i) of Item 1 in Appendix 13 V, the part other than each subparagraph of Item 3 in Table V, Item 1 in Table VII, Item 5 in Appendix 15 II, Table IV Item 5 Subparagraph (b), IV Item 6 Subparagraph (b), IV Item 20 Subparagraph (b), IV Item 21, Table V Item 5, Appendix 18 IV Item 5 Subparagraph (g) 3), Table V Item 1 Subparagraph (a), Appendix 19 I Item 3 Subparagraph (a) proviso, proviso to the part excluding Subparagraph (b) 1) through 6), Subparagraph 6), I Items 4 and 5, I Item 6 Subparagraph (a) main text and proviso, I Item 6 Subparagraph (b) main text and proviso, Table II Item 2 Subparagraph (g), II Item 6 Subparagraph (b), proviso to the part excluding each subparagraph of II Item 8, proviso to the part excluding each subparagraph of II Item 13, Subparagraph (d), Appendix 24 Item 5 front section excluding the table, Appendix 25 Item 3 Subparagraph (a) from the foundation and ground inspection table The term "fees up to double-walled tank inspection," the term "fees from foundation and ground inspection to double-walled tank inspection" in the table under subparagraph (b) of the same subparagraph, the proviso in the part other than each item of subparagraph 4 of the same table, and subparagraphs 8 through 10 of the same table shall each replace "Minister of Public Safety and Security" with "Commissioner of the National Fire Agency." In Form No. 33, the front of Form No. 34, and Form No. 35, “Minister of Public Safety and Security” shall be changed to “Commissioner of the Fire Department”. In the processing procedure section of Form No. 33 and Form No. 35, “Ministry of Public Safety and Security” shall be changed to “Fire Agency”. Omit 15 through 17 ADDENDA <Ministry of the Interior and Safety Decree No. 32, Dec. 29, 2017> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Transitional Measures Concerning the Timing of Structural Safety Inspections for Quasi-Specific Outdoor Tank Storage Facilities)  ① Persons responsible for outdoor tank storage facilities installed before the enforcement of this Rule that store or handle a maximum quantity of liquid hazardous materials of 500,000 liters or more and less than 1,000,000 liters (hereinafter referred to as “quasi-specific outdoor tank storage facilities”) shall undergo a structural safety inspection within the period specified in each of the following subparagraphs, notwithstanding the main text of the part other than each subparagraph of Article 65, Paragraph 1 and each subparagraph of the same Paragraph. 1. In the case of quasi-specific outdoor tank storage facilities that passed the leak inspection pursuant to Article 13, Paragraph 3 of the Soil Environment Conservation Act prior to the enforcement of this Rule: 8 years from the date of receiving the notification of the leak inspection results 2. In the case of a quasi-specific outdoor tank storage facility other than the quasi-specific outdoor tank storage facility under Subparagraph 1: the period according to the classification of each of the following items a. In cases where the initial completion inspection was passed prior to 1987: December 31, 2018 B. In the case of passing the initial completion inspection during the period from 1988 to 1997: June 30, 2019 C. In the case of passing the final inspection for the first time during the period from 1998 to 2005: December 31, 2019 D. In the case of passing the final inspection for the first time during the period from 2006 to 2008: December 31, 2020 ② The extension of the period for conducting structural safety inspections pursuant to Paragraph 1 shall be in accordance with the amended provisions of the proviso to the part other than each subparagraph of Article 65, Paragraph 1. Article 3 (Transitional Measures Concerning the Timing of Periodic Inspections for Quasi-Specific Outdoor Tank Storage Facilities)  ① Notwithstanding the main text of the part other than the subparagraphs of Article 70, Paragraph 1 and the subparagraphs of the same paragraph, persons concerned with quasi-specific outdoor tank storage facilities installed prior to the enforcement of this Rule shall undergo periodic inspections pursuant to Article 18, Paragraph 2 of the Act within the period specified in the subparagraphs of Article 2, Paragraph 1 of the Addenda. ② Changes to the timing of periodic inspections pursuant to Paragraph 1 shall be in accordance with the proviso to the part other than each subparagraph of Article 70, Paragraph 1 and the amended provisions of Paragraph 3 of the same article. ADDENDA <Ministry of the Interior and Safety Decree No. 88, Jan. 3, 2019> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 206, Oct. 12, 2020> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, the amended provisions of each of the following subparagraphs shall enter into force on the date specified in each of the following subparagraphs. 1. Amended provisions of Subparagraph 2(a) of Attached Table 25 and Notes Subparagraphs 1 and 2 of the same subparagraph: January 1, 2021 2. Amended provisions of Article 65, Paragraph 1; Article 70, Paragraphs 1 and 3; Article 71, Paragraphs 1 and 4; Article 72, Paragraphs 2 and 3; the front of Form No. 44; the front of Form No. 45; and Form No. 46: March 1, 2021 3. Amended provisions of Article 42, Paragraph 2, Annex 6 VI, Item 7, Subparagraph (a) 3), and Annex 17 II, Items 1 through 3: July 1, 2021 Article 2 (Transitional Measures Concerning Intermediate Periodic Inspections, etc.)  ① Specific or quasi-specific outdoor tank storage facilities that have undergone a periodic inspection pursuant to the former Article 70, Paragraph 1 at the time of enforcement pursuant to Subparagraph 2 of Article 1 of the Addenda shall be deemed to have undergone a detailed periodic inspection pursuant to the amended provisions of Article 70, Paragraph 1, Subparagraph 1. ② Notwithstanding the amended provisions of Article 70, Paragraph 1, Subparagraph 2, persons concerned with specific or quasi-specific outdoor tank storage facilities installed prior to the effective date pursuant to Subparagraph 2 of Article 1 of the Addenda shall undergo an interim periodic inspection pursuant to the amended provisions of Article 70, Paragraph 1, Subparagraph 2 within the deadlines specified in each of the following subparagraphs. 1. If the initial completion inspection or the most recent periodic detailed inspection was passed before January 1, 2014: December 31, 2021 2. If the initial completion inspection or the most recent periodic precision inspection was passed during the period from January 1, 2014, to December 31, 2016: December 31, 2022 3. If the initial completion inspection or the most recent periodic precision inspection was passed during the period from January 1, 2017 to December 31, 2019: December 31, 2023 ③ Notwithstanding Paragraph 2, if a person with a specific or semi-specific outdoor tank storage facility installed prior to the effective date pursuant to Subparagraph 2 of Article 1 of the Addenda does not undergo the intermediate periodic inspection pursuant to Subparagraph 1 of Paragraph 2 if they undergo and pass the detailed periodic inspection within the said period and pass the detailed periodic inspection within the said period. Article 3 (Transitional Measures Concerning the Installation of Flame-Prevention Devices and Inflammability Prevention Devices)  In the case of an outdoor tank storage facility for which an installation permit was obtained pursuant to the main text of Article 6, Paragraph 1 of the Act prior to the effective date pursuant to Subparagraph 3 of Article 1 of the Addenda, the former provisions shall apply notwithstanding the amended provisions of Subparagraph 3, Item 7 (a) of Annex 6 VI. However, in the case of applying for a permit for modification pursuant to the proviso of Article 6, Paragraph 1 of the Act (excluding permits for modification corresponding to Subparagraphs e through g, g and h) of Subparagraph 3 of Annex 1-2 of this Rule) or a detailed periodic inspection for the said outdoor tank storage facility after the effective date pursuant to Subparagraph 3 of Article 1 of the Addenda, the amended provisions of Subparagraph 3, Item 7 (a) of Annex 6 VI shall apply. Article 4 (Transitional Measures Concerning the Installation of Alarm Equipment)  In the case of an outdoor tank storage facility for which an installation permit was obtained pursuant to the main text of Article 6, Paragraph 1 of the Act on the effective date pursuant to Subparagraph 3 of Article 1 of the Addenda, the former provisions shall apply notwithstanding the amended provisions of Item 1, Subparagraph (e) of Annex 17 II. However, if an application for a permit for change pursuant to the proviso of Article 6, Paragraph 1 of the Act (excluding permits for change corresponding to Items 3, Subparagraphs (e) through (g), (g) and (s) of Annex 1-2 of this Rule) or a detailed periodic inspection is made for the said outdoor tank storage facility after the effective date pursuant to Subparagraph 3 of Article 1 of the Addenda, the amended provisions of Item 1, Subparagraph (e) of Annex 17 II shall apply. Article 5 (Transitional Measures Concerning Practical Training)  ① If a person who is appointed as a safety manager of a manufacturing facility, etc., or is engaged as a dangerous goods transporter at the time of the enforcement of this Rule has not received practical training pursuant to Item 1 of Annex 24 of the former, he/she must receive practical training within six months from the date of enforcement of this Rule, notwithstanding the amended provisions of Item 1 of Annex 24. ② If a person who is appointed as a safety manager of a manufacturing facility, etc., or is engaged as a dangerous goods transporter at the time of the enforcement of this rule has received practical training pursuant to Item 1 of Annex 24 of the former, the date on which such practical training was received shall be deemed to have received the practical training required to be received within six months from the date of appointment or the date of employment pursuant to the amended provisions of Item 1 of Annex 24. ADDENDA <Ministry of the Interior and Safety Decree No. 254, June 10, 2021> This rule will take effect on June 10, 2021. ADDENDA <Ministry of the Interior and Safety Decree No. 268, July 13, 2021> (Ministry of the Interior and Safety Decree on the Partial Amendment of 13 Laws for the Reorganization of Difficult Legal Terms) This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 284, Oct. 21, 2021> This rule shall take effect on October 21, 2021. ADDENDA <Ministry of the Interior and Safety Decree No. 360, Dec. 1, 2022> (Enforcement Rule of the Act on Installation and Management of Firefighting Facilities) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. <Proviso Omitted> Articles 2 through 5  omitted Article 6 (Amendment of Other Laws)  ① through ④ Omitted ⑤ Part of the Enforcement Rules of the Dangerous Goods Safety Management Act is amended as follows. In Article 45, “Article 36 of the Act on Fire Prevention, Installation and Maintenance of Firefighting Facilities and Safety Management” shall be changed to “Article 37 of the Act on Installation and Management of Firefighting Facilities”. In Article 46, “the Act on Fire Prevention, Installation and Maintenance of Firefighting Facilities and Safety Management” shall be changed to “the Act on Installation and Management of Firefighting Facilities”. ⑥ Omitted Article 7  omitted ADDENDA <Ministry of the Interior and Safety Decree No. 373, Jan. 5, 2023> (Ministry of the Interior and Safety Decree on the Partial Amendment of Two Acts for the Support of Economic Recovery of Small Business Owners) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Applicability to Standards for Administrative Dispositions)  The amended provisions of Articles 1 and 2 shall apply even when administrative dispositions are imposed after the enforcement of this Rule for violations committed prior to the enforcement of this Rule. ADDENDA <Ministry of the Interior and Safety Decree No. 409, June 29, 2023> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Transitional measures concerning standards for the location, structure, and facilities of gas stations)  Gas stations that had charging facilities for electric vehicles installed prior to the enforcement of this rule shall be subject to the former regulations notwithstanding the amended provisions of Subparagraph 2) and 4) of Item 1, Subparagraph (a) of Annex 13 VI. ADDENDA <Ministry of the Interior and Safety Decree No. 482, May 20, 2024> Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. However, the amended provisions of Item 5, Subparagraph (e) of Annex 15 III shall enter into force three months after the date of promulgation, and the amended provisions of Item 1, Subparagraph (e) and Item 2, Subparagraph (e) of Annex 16 X-3, Item 1, Subparagraph (e) and Item 2, Subparagraph (e) of Annex X-4, and Item 6 of Note 1 of Annex 17 I shall enter into force one year after the date of promulgation. Article 2 (Transitional Measures Concerning Forms)  Forms in use pursuant to the previous regulations at the time of the enforcement of this Rule may continue to be used together with the forms pursuant to this Rule (excluding Form No. 35). In this case, the parts amended pursuant to this Rule must be modified before use. Article 3 (Transitional Measures Concerning the Processing Period of Reports)  Notwithstanding the amended provisions of Forms No. 29-2 and No. 35-2, the processing period for reports submitted at the time of the enforcement of this Rule shall be governed by the former provisions. ADDENDA <Ministry of the Interior and Safety Decree No. 493, July 2, 2024> Article 1 (Enforcement Date)  This rule shall enter into force on July 4, 2024. Article 2 (Special provisions regarding the evaluation of the implementation status of preventive regulations)  Notwithstanding the amended provisions of Article 63-2, Paragraph 1, Item 1, for manufacturing facilities, etc. that submitted preventive regulations pursuant to Article 17, Paragraph 1 of the Act prior to the enforcement of this Rule, an initial evaluation shall be conducted within 3 years from the date of enforcement of this Rule. ADDENDA <Ministry of the Interior and Safety Decree No. 503, July 30, 2024> This rule shall take effect on July 31, 2024. ADDENDA <Ministry of the Interior and Safety Decree No. 530, Dec. 31, 2024> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 628, July 1, 2026> (Ministry of the Interior and Safety Decree on the Partial Amendment of 22 Laws under the Jurisdiction of the National Fire Agency Pursuant to the Establishment of Integrated Special Cities) This rule shall take effect on July 1, 2026. [Attached Table 1] Documents to be attached to the application for a transfer handling facility permit (related to Article 6, Item 9) [Appendix 1-2] Cases requiring permission for change of manufacturing facility, etc. (Related to Article 8) [Appendix 2] Standards for Administrative Dispositions (Related to Article 25, Article 58 Paragraph 1, and Article 62 Paragraph 1) [Attached Table 3] Amount of Surcharge (Related to Article 26, Item 1) [Attached Table 3-2] Amount of Surcharge (Related to Article 26, Subparagraph 2) [Appendix 4] Standards for Location, Structure, and Facilities of Manufacturing Plants (Related to Article 28), Standards for Reduction of Safety Distances for Manufacturing Plants, etc. (Related to Appendix 4) [Appendix 5] Standards for Location, Structure, and Facilities of Indoor Storage Facilities (Related to Article 29) [Appendix 6] Standards for Location, Structure, and Facilities of Outdoor Tank Storage Facilities (Related to Article 30) [Appendix 7] Standards for Location, Structure, and Facilities of Indoor Tank Storage Facilities (Related to Article 31) [Appendix 8] Standards for Location, Structure, and Facilities of Underground Tank Storage Facilities (Related to Article 32) [Appendix 9] Standards for Location, Structure, and Facilities of Simple Tank Storage Facilities (Related to Article 33) [Appendix 10] Standards for Location, Structure, and Facilities of Mobile Tank Storage Facilities (Related to Article 34) [Appendix 11] Standards for Location, Structure, and Facilities of Outdoor Storage Facilities (Related to Article 35) [Appendix 12] Standards for Location, Structure, and Facilities of Rock Tank Storage Facilities (Related to Article 36) [Appendix 13] Standards for Location, Structure, and Facilities of Gas Stations (Related to Article 37) [Appendix 14] Standards for Location, Structure, and Facilities of Sales Outlets [Related to Article 38] [Appendix 15] Standards for Location, Structure, and Facilities of Transfer Handling Stations (Related to Article 39) [Appendix 16] Standards for Location, Structure, and Facilities of General Handling Stations (Related to Article 40) [Appendix 17] Standards for Fire Extinguishing, Alarm, and Evacuation Facilities (Related to Article 41, Paragraph 2, Article 42, Paragraph 2, and Article 43, Paragraph 2) [Appendix 18] Standards for the Storage and Handling of Dangerous Goods at Manufacturing Facilities, etc. (Related to Article 49), Maximum Volume or Weight of Transport Containers (Related to Appendix 18) [Appendix 19] Standards for the Transport of Dangerous Goods (Related to Article 50), Maximum Volume or Weight of Transport Containers (Related to Appendix 19), Standards for Mixing Dangerous Goods of Different Classes (Related to Appendix 19) [Attached Table 20] Maximum volume of transport containers designed for mechanical unloading (related to Article 51, Paragraph 1) [Appendix 21] Methods of supervision or support by the person responsible for transporting dangerous goods and matters to be observed during the transport of dangerous goods [Related to Article 52, Paragraph 2] [Appendix 22] Criteria for Designation of Safety Management Agencies (Related to Article 57, Paragraph 1) [Appendix 23] Standards for Firefighting Capabilities and Equipment to be Equipped with Chemical Firefighting Vehicles [Related to Article 75, Paragraph 1] [Appendix 24] Courses and duration of safety education and other matters concerning the implementation of education, etc. (Related to Article 78, Paragraph 2) [Attached Table 25] Fees and Education Expenses (Related to Article 79, Paragraph 1) [Attachment Form No. 1] Application for Permit for Installation of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 2] Application for Permission to Install Transfer Handling Station [Attachment Form No. 3] (Manufacturing Plant, General Handling Plant) Specification of Structure and Equipment [Attachment Form No. 4] Specification of Structure and Equipment for Indoor Storage Facilities [Attachment Form No. 5] Specification of Structure and Equipment for Outdoor Tank Storage Facilities [Attachment Form No. 6] Specification of Structure and Equipment for Indoor Tank Storage Facilities [Attachment Form No. 7] Specification of Structure and Equipment for Underground Tank Storage [Attachment Form No. 8] Specification of Structure and Equipment for Simple Tank Storage Facilities [Attachment Form No. 9] Specification of Structure and Equipment for Mobile Tank Storage Facilities [Attachment Form No. 11] Specification of Structure and Equipment for Outdoor Storage Facilities [Attachment Form No. 12] Specification of Structure and Equipment for Rock Tank Storage [Attachment Form No. 13] Specification of Structure and Equipment for Gas Stations [Attachment Form No. 14] (Type 1 Sales Outlet, Type 2 Sales Outlet) Specification of Structure and Facilities [Attachment Form No. 15] Specification of Structure and Equipment for Transfer Handling Station [Attachment Form No. 16] Application for Change of Permit for Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 17] Application for Permission to Change Transfer Handling Station [Form No. 17-2] Application for Technical Review (Manufacturing Plant, General Handling Plant) [Attachment Form No. 18] Application for Technical Review (Outdoor Tank Storage, Rock Tank Storage) [Attachment Form No. 19] Notification of Change in Name, Quantity, or Multiple of Designated Quantity for Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 20] Application for Safety Performance Inspection (Test) of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) Tank [Attachment Form No. 21] Certificate of Passage for Tank Inspection (Test) [Attachment Form No. 22] Application for Completion Inspection of Hazardous Materials [Manufacturing Facility, Storage Facility, Handling Facility (All, Partial)] [Attachment Form No. 23] Application for Completion Inspection of Transfer Handling Station [Attachment Form No. 24] Certificate of Completion Inspection for Hazardous Material Manufacturing Facilities, etc. [Attachment Form No. 25] Certificate of Completion Inspection for Mobile Tank Storage Facility [Attachment Form No. 26] Application for Reissuance of Certificate of Passing Completion Inspection [Attachment Form No. 27] Application for Approval of Temporary Use of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 28] Notification of Succession of Status of Installer of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 29] Notification of Decommissioning of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Form No. 29-2] Notification of Use (Suspension, Resumption) of Hazardous Materials (Manufacturing Facility, Storage Facility, Handling Facility) [Attachment Form No. 30] Application for Inspection of Hazardous Material Containers [Attachment Form No. 31] Certificate of Passing Dangerous Goods Container Inspection [Attachment Form No. 32] Report on Appointment of Safety Manager [Attachment Form No. 33] Application for Designation of Dangerous Goods Safety Management Agency [Attachment Form No. 34] Designation of Dangerous Goods Safety Management Agency [Attachment Form No. 35] Notification of Change of Dangerous Goods Safety Management Agency [Form No. 35-2] Report on Dangerous Goods Safety Management Agency (Suspension, Closure, Resumption) [Attachment Form No. 36] Application for Registration of Hazardous Material Tank Safety Performance Tester [Form No. 37] Registration Certificate for Hazardous Material Tank Safety Performance Testers [Attachment Form No. 38] Notification of Change of Hazardous Material Tank Safety Performance Tester [Attachment Form No. 39] Submission Form for Preventive Regulations (Enactment, Amendment) [Form No. 39-2] Application for Extension of Structural Safety Inspection Period for Specific/Semi-Specific Outdoor Tank Storage Facilities [Attachment Form No. 40] Application for Extension of Structural Safety Inspection Period for Specific and Semi-Specific Outdoor Tank Storage Facilities (Status of Tank Corrosion Prevention, etc.) [Attachment Form No. 41] Application for Extension of Structural Safety Inspection Period for Specific and Semi-Specific Outdoor Tank Storage Facilities (Status of Storage Management of Hazardous Materials, etc.) [Attachment Form No. 42] Request for Periodic Inspection of Hazardous Material Manufacturing Facilities, etc. [Attachment Form No. 43] Periodic Inspection Results Report for Hazardous Material Manufacturing Facilities, etc. [Attachment Form No. 44] Application for Periodic Inspection of Specific/Semi-Specific Outdoor Tank Storage Facilities (Precision, Intermediate) [Attachment Form No. 45] Application for Approval of Change in Periodic Inspection Schedule for Specific/Semi-Specific Outdoor Tank Storage Facilities (Precision, Intermediate) [Attachment Form No. 46] Certificate of Passing Periodic Inspection for Specific/Semi-Specific Outdoor Tank Storage Facilities (Precision, Intermediate) [Attachment Form No. 47] Fire Inspection Report for Hazardous Material Manufacturing Facilities, etc. [Attachment Form No. 48] Dangerous Goods Safety Card