Rules on Housing Construction Standards, etc.
288501 · 2026-07-29
Article 1 (Purpose) The purpose of these Rules is to prescribe matters delegated by Articles 38, 39, and 51 Paragraph 1 of the Housing Act and the Regulations on Housing Construction Standards, etc., and matters necessary for their implementation. <Amended Jul. 20, 1993; Sep. 29, 1999; Dec. 15, 2003; Jun. 30, 2014; Dec. 24, 2014; Aug. 12, 2016>
Article 2 (Special Provisions for Application) Pursuant to Article 7, Paragraph 6 of the “Regulations on Housing Construction Standards, etc.” (hereinafter referred to as the “Enforcement Decree”), the construction standards for housing falling under each of the following subparagraphs and the installation standards for ancillary facilities and welfare facilities shall be in accordance with Annex 1. <Amended Oct. 19, 2020>
1. Housing constructed for low-income workers with an exclusive area of 60 square meters or less per household (hereinafter referred to as "worker housing")
2. A house falling under any of the following items
A. Permanent rental housing pursuant to Article 2, Paragraph 1, Subparagraph 1 of the Enforcement Decree of the Special Act on Public Housing, wherein the exclusive area per household is 50 square meters or less (hereinafter referred to as "permanent rental housing")
B. Happy Housing pursuant to Article 2, Paragraph 1, Subparagraph 3 of the Enforcement Decree of the Special Act on Public Housing (hereinafter referred to as "Happy Housing")
C. Publicly purchased rental housing pursuant to Article 43, Paragraph 1 of the Special Act on Public Housing, which is a house improved by purchasing existing houses, etc. in accordance with Article 37, Paragraph 2 of the Enforcement Decree of the same Act (hereinafter referred to as "house improved after purchasing existing houses, etc.")
[Wholly Revised 2016.9.12]
Article 3 (Dimensions and Standard Scales) The floor plans and dimensions and standard scales of each part of a dwelling pursuant to Article 13 of the Enforcement Decree shall be as follows: <Amended Mar. 14, 2008; Sep. 25, 2008; Mar. 23, 2013; Jul. 15, 2013>
1. Dimensions and reference scales shall, in principle, be based on visual dimensions. However, centerline dimensions may be used if necessary in accordance with the methods for establishing modular grids and reference planes based on the principles of modular alignment prescribed by Korean Industrial Standards.
2. The length of each side of the floor plan of the living room and bedroom shall be based on a standard scale of 5 centimeters.
3. The length or width of each side of the floor plan of kitchens, dining rooms, bathrooms, toilets, corridors, stairs, and landings, etc., shall be based on a standard scale of 5 centimeters. However, if prefabricated bathrooms for residential use specified in the Korean Industrial Standards are used, they shall comply with the standard module nominal dimensions specified in the Korean Industrial Standards.
4. The ceiling height of living rooms and bedrooms (only applicable if a ceiling is installed) shall be at least 2.2 meters, and the floor height shall be at least 2.4 meters, with each using a standard scale based on a unit of 5 centimeters.
5. The dimensions of openings for window and door installation shall be in accordance with the standard module nominal dimensions of window and door openings and window and door components as prescribed by the Korean Industrial Standards. However, matters not specified by the Korean Industrial Standards shall be in accordance with the standard detailed architectural drawings prescribed and announced by the Minister of Land, Infrastructure and Transport.
6. Specific matters other than those specified in Subparagraphs 1 through 5 shall comply with the standards determined and notified by the Minister of Land, Infrastructure and Transport.
[Wholly Revised 1997.7.21]
Article 3-2 (Exclusion from Application of Floor Impact Sound Performance Standards) In subparagraph 2, item (b) of Article 14-2 of the Enforcement Decree, the term "parts prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, such as balconies and entrances" refers to parts falling under each of the following subparagraphs. <Amended Aug. 12, 2016; Aug. 4, 2022>
1. Balcony
2. Entrance
3. Laundry Room
4. Evacuation Space
5. Wall-partitioned warehouse
6. In addition to the parts corresponding to Subparagraphs 1 through 5, a space where the authority approving the business plan pursuant to Article 15 of the Housing Act (hereinafter referred to as the "Act") (hereinafter referred to as the "Business Plan Approval Authority") recognizes that the application of floor impact sound performance standards is unnecessary due to a low possibility of damage caused by inter-floor noise.
[This Article Newly Established 2013.7.15]
Article 4 (Elevators) Pursuant to the main text of Article 15, Paragraph 1 of the Enforcement Decree, the installation standards for passenger elevators installed in multi-unit dwellings with six or more floors are as follows: <Amended July 15, 2013>
1. In multi-unit dwellings of the stairwell type, at least one unit shall be installed in each stairwell (two units in the case of a stairwell-type multi-unit dwelling of 22 stories or more where three or more households are combined on one floor), provided that the passenger capacity shall be at least the number calculated at a rate of 0.3 persons (0.15 persons in the case of single-person housing) per household on floors 4 or higher using the same stairwell (fractions of 1 person or less shall be deemed 1 person; the same shall apply hereinafter in this Article).
2. In corridor-type multi-unit dwellings, at least one additional unit shall be installed for every 80 households exceeding 100 households, provided that the passenger capacity is at least the number calculated at a rate of 0.2 persons per household (0.1 persons in the case of single-person housing) for floors 4 or higher.
Article 5 (Installation Standards for Flagpole Holders) In cases where a device for inserting a flagpole is installed at a ground-level entrance of each building pursuant to the proviso of Article 18, Paragraph 4 of the Enforcement Decree, it shall be installed in the center or on the left side (referring to the left side when viewing the building from the front of the entrance) of the wall above the said entrance.
[This Article Newly Established 2021.1.12]
Article 6 (Roads within Housing Complexes)
① A child safety protection zone pursuant to Article 26, Paragraph 4 of the Enforcement Decree (hereinafter referred to as "child safety protection zone") shall be established in a place where vehicle entry and exit are easy, with a space of at least an area sufficient for parking passenger vehicles, and necessary measures to ensure the safety of children shall be taken, such as marking vehicle speed limits on the surrounding road surface or on traffic safety signs. <Amended Dec. 26, 2017>
② In addition to the matters prescribed in Paragraph 1, necessary matters concerning specific installation standards for child safety protection zones may be determined by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province, City, or County. <Newly added 2017.12.26>
③ The installation standards for roads installed within a housing complex pursuant to Article 26, Paragraph 5 of the Enforcement Decree are as follows: <Amended 2017.12.26>
1. Roadways within the housing complex shall be paved with asphalt, concrete, stone, or other similar materials, and installed in a manner that ensures unimpeded drainage of rainwater, etc.
2. Sidewalks among the roads within the housing complex shall comply with the standards of each of the following items:
a. It shall be paved with paving blocks, stone, or other similar materials, and installed in such a way that there is no obstruction to the drainage of rainwater, etc.
B. For the safety of pedestrians, sidewalks shall be installed at least 10 centimeters higher than the roadway surface, or separated from the roadway by installing flowerbeds, short posts, or other similar facilities on the road.
C. When installing roadside facilities, such as street trees, on sidewalks, they shall be installed in a manner that does not obstruct pedestrian traffic.
3. The boundary between sidewalks and crosswalks within housing complexes, and the boundary between sidewalks and roadways in front of building entrances, shall be constructed in a structure convenient for the passage of persons with physical disabilities.
④ The installation standards for traffic safety facilities installed within a housing complex pursuant to Article 26, Paragraph 5 of the Enforcement Decree are as follows: <Amended 2017.12.26>
1. Install crosswalks on roadways where pedestrian safety needs to be ensured, such as access roads, intersections within residential complexes, and roads surrounding neighborhood facilities and children's playgrounds.
2. At entrances and exits of underground parking lots, sloping or curved roadways, and other places where it is necessary to limit vehicle speed, speed bumps with a height of at least 7.5 centimeters and a width of at least 1 meter shall be installed, and road markings painted with reflective paint shall be installed to inform drivers of the location of such facilities.
3. Road reflectors, traffic safety signs, guardrails, speed limit signs, lighting facilities, and other necessary traffic safety facilities shall be installed where deemed necessary for the safety of road traffic. In this case, the installation standards for traffic safety signs shall be in accordance with Article 8, Paragraph 2 and Annex 6 of the Enforcement Rules of the Road Traffic Act.
4. In places where it is necessary to prevent illegal parking, such as the boundary between sidewalks and crosswalks, sidewalks in front of building entrances, and the boundary between sidewalks and roadways near the entrances of housing complexes, short posts or similar structures that are easy to install or remove shall be installed on the sidewalk. In this case, care must be taken to ensure that the passage of persons with physical disabilities is not obstructed.
[Wholly Revised 2013.7.15]
Article 6-2 (Structure and Facilities of Parking Lots)
① The standards for the structure and facilities of parking lots pursuant to Article 27, Paragraph 8 of the Enforcement Decree are as follows: <Amended Sep. 29, 1999; Nov. 5, 2009; Oct. 29, 2010; Jan. 6, 2011; Aug. 12, 2016; Dec. 26, 2017; Jan. 16, 2019; Jan. 7, 2020; Jan. 12, 2021; Feb. 11, 2022; Dec. 19, 2022; Jan. 30, 2026; Jul. 29, 2026>
1. The parking unit sections of the parking lot shall comply with the standards pursuant to Article 3 of the Enforcement Rules of the Parking Lot Act.
2. Subparagraphs 1 through 9 and 11 of Article 6, Paragraph 1 of the Enforcement Rules of the Parking Lot Act shall apply mutatis mutandis. However, where a roadway in an above-ground parking lot allowing vehicle access to each building of a multi-unit dwelling, or a road within a housing complex pursuant to Article 26 of the Enforcement Decree, is not installed, the height of the parking lot roadway (limited to the roadway of the relevant floor where direct access from the ground level is possible to the entrance of each building, in cases where the parking lot consists of two or more floors) shall be at least 2.7 meters from the parking floor surface, notwithstanding Article 6, Paragraph 1, Subparagraph 5, Item (a) of the Enforcement Rules of the Parking Lot Act, except in cases falling under any of the following subparagraphs.
A. In cases where, as a result of deliberation, etc. pursuant to each subparagraph of Article 18, Paragraph 1 of the Act regarding the housing construction project plan, it is recognized that vehicle access to all buildings is possible at the ground level, considering the layout of the housing complex and road conditions inside and outside the housing complex, etc.
B. In the case of remodeling pursuant to Article 2, Subparagraph 25, Item C of the Act or a maintenance project pursuant to Article 2, Subparagraph 2, Items B and C of the Urban and Residential Environment Improvement Act, where the relevant association has determined the height of the parking lot lanes to be the height pursuant to Article 6, Paragraph 1, Subparagraph 5, Item A of the Enforcement Rules of the Parking Lot Act
3. When installing a mechanical parking device under Article 2, Subparagraph 2 of the Parking Lot Act, installation may be limited to cases falling under any of the following subparagraphs, and it shall comply with the standards pursuant to Article 16-2 of the Enforcement Rule of the Parking Lot Act.
A. In cases where apartment-type housing pursuant to Article 10, Paragraph 1, Subparagraph 1 of the Enforcement Decree of the Housing Act and facilities other than housing are constructed as the same building in a commercial area or semi-residential area pursuant to Article 30 of the Enforcement Decree of the National Land Planning and Utilization Act
B. In the case of a mechanical parking facility including an automatic transfer parking device pursuant to the part other than each item of Article 6, Paragraph 1, Subparagraph 11 of the Enforcement Rules of the Parking Lot Act, where the project plan approval authority recognizes that there is no impediment to the residential environment
C. In the case of a mechanical parking facility including an auto-valet parking device pursuant to Article 16-2, Paragraph 1, Subparagraph 2, Item C of the Enforcement Rules of the Parking Lot Act, where the authority approving the business plan recognizes that there is no impediment to the residential environment
4. Install at least the number of outlets capable of using portable chargers for electric vehicles pursuant to Article 2, Subparagraph 3 of the "Act on the Promotion of Development and Dissemination of Environmentally Friendly Vehicles" (hereinafter referred to as "portable chargers") (referring to outlets installed to allow simultaneous use of portable chargers for each outlet and to charge fees to users; hereinafter the same applies) equal to the total number of parking unit spaces pursuant to Article 2, Subparagraph 7 of the "Parking Lot Act" multiplied by the ratios classified in each of the following subparagraphs (rounded up to the nearest whole number). However, if necessary considering the regional electric vehicle penetration rate, etc., the installation standards may be strengthened or relaxed by ordinance of a Special Self-Governing City, Special Self-Governing Province, City, County, or Autonomous District within the range of one-fifth of the ratios prescribed in each of the following subparagraphs.
A. Until June 31, 2023: 4 percent
B. From July 1, 2023 to December 31, 2024: 7 percent
C. After January 1, 2025: 10 percent
② Where outlets capable of using portable chargers are installed pursuant to the main text or proviso of Paragraph 1, Subparagraph 4, and rapid charging facilities or slow charging facilities pursuant to Article 18-7, Paragraph 1, Subparagraph 1 or 2 of the Enforcement Decree of the Act on Promotion of Development and Dissemination of Environmentally Friendly Vehicles are installed in the parking lot, the same number of outlets shall be deemed to have been installed. <Newly added 2022.12.19>
[This Article Newly Established 1993.7.20]
Article 7 (Flood Prevention)
① In cases where a slope exists within a housing complex (including the outer perimeter surrounding the complex boundary), measures for flood prevention, etc. shall be taken in accordance with the provisions of each of the following subparagraphs. <Amended Mar. 26, 2001; Dec. 15, 2003; Jul. 15, 2013>
1. Install drainage channels using stone, synthetic resin, or concrete to prevent soil erosion
2. If the height of the slope exceeds 3 meters, terraces shall be constructed at intervals of no more than 3 meters in height, with an area equivalent to at least one-fifth of the slope's surface area. However, this shall not apply if the project plan approval authority deems that there is no impediment to the safety of the building based on the soil quality, slope gradient, etc. of the slope.
3. Trees shall be planted and grass laid on the slopes. However, if necessary for the safety of the slopes, stone paving or concrete grid blocks and other slope protection structures shall be installed.
② The positional relationship between the slope and buildings, etc. shall comply with each of the following subparagraphs. <Amended Jul. 20, 1993; Mar. 26, 2001; Jan. 30, 2026>
1. The outer perimeter of a building shall be set back from the closer of the upper or lower edge of the slope by an amount equal to the height of the slope. However, this shall not apply if the project plan approval authority recognizes that there is no impediment to the safety of the building based on the soil quality, slope gradient, etc. of the slope.
2. If there is a retaining wall or embankment (hereinafter referred to as "retaining wall, etc.") at the lower part of the slope, a step with a width of at least 1 meter shall be constructed between the retaining wall, etc. and the slope.
3. If there is a retaining wall, etc. at the upper part of the slope, a step shall be constructed between the retaining wall, etc. and the slope with a width of at least 1.5 meters and a width equivalent to at least half the height of the said retaining wall, etc.
Article 8 (Standards for Installation Space of Air Conditioning Exhaust Devices)
① In Article 37, Paragraph 6 of the Enforcement Decree, the term "standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" refers to those that satisfy all of the requirements of each of the following subparagraphs.
1. The space shall be partitioned to be separated from the area where residents normally live, so that the residential environment does not deteriorate when the cooling system is in operation. However, this shall not apply if the space for installing the exhaust device is provided in a location directly exposed to outside air.
2. The size shall be the sum of the specifications of the exhaust device for the cooling system, which has a capacity appropriate for the exclusive residential area of each household, plus the margin space required for the installation, maintenance, and management of the exhaust device.
3. In cases where the exclusive residential area per household exceeds 50 square meters and there are two or more living rooms or bedrooms within the household, connecting pipes for the air conditioning exhaust system shall be installed in at least two spaces, including the living room.
4. If the installation space for the air conditioning exhaust device is provided in a location directly exposed to outside air, a railing conforming to Article 18, Paragraphs 1 and 2 of the Enforcement Decree shall be installed around the installation space.
② The clearance space required for the installation, maintenance, and management of the exhaust device pursuant to Paragraph 1, Subparagraph 2 shall be in accordance with the classifications in each of the following subparagraphs.
1. In cases where the installation space for the exhaust device is provided in a location directly exposed to outside air, and an access door is installed in the space for the cooling system exhaust device, allowing the exhaust device to be installed with the door open: Width 0.5 meters or more
2. In other cases: Width 0.5 meters or more and height 0.7 meters or more
[New article established 2020.1.7]
Article 9 (Standards for Installation of Image Information Processing Devices) The term "standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" in Article 39 of the Enforcement Decree refers to the standards set forth in each of the following subparagraphs. <Amended Dec. 11, 2023, Jan. 30, 2026>
1. Install cameras of image information processing devices (hereinafter referred to as "image information processing devices") pursuant to Article 3, Paragraph 1, Subparagraph 1 or 2 of the Enforcement Decree of the Personal Information Protection Act at every entrance of elevators, children's playgrounds, and each building of multi-unit housing.
2. The camera of the image information processing device shall be installed so that the entire or major parts can be viewed and clearly identified, and the camera resolution shall be 1.3 million pixels or higher.
3. The number of cameras of the image information processing device and the number of monitors of the recording device shall be installed to be equal. However, this shall not apply if the monitor screen is capable of being divided into multiple channels and satisfies all of the requirements of each of the following subparagraphs.
A. When monitoring multi-channel camera signals connected to a single recording device, all connected camera signals must be displayed on the monitor screen, and the diagonal size of a single-channel monitoring screen must be at least 4 inches.
B. The monitor screen displaying multi-channel signals shall have an magnified monitoring function for each channel.
c. Recorded footage must be playable, and there must be a screen size adjustment function during playback.
4. When installing a network camera pursuant to Article 3, Paragraph 1, Subparagraph 2 of the Enforcement Decree of the Personal Information Protection Act, all of the following requirements shall be satisfied:
A. Take necessary technical measures to ensure that video information is continuously stored without interruption even in the event of an internet failure.
B. Major facilities, such as servers and storage devices, shall be installed domestically.
C. Install so as to operate for a period exceeding the repair cycle specified in the standards for establishing a long-term repair plan under Annex 1 of the Enforcement Rules of the Multi-Family Housing Management Act.
[Wholly Revised 2019.1.16]
Article 10 (Drainage Facilities, etc.)
① Drainage facilities pursuant to the provisions of Article 43, Paragraph 4 of the Enforcement Decree shall be connected to the sewage pipeline.
② With respect to the standards for the installation and structure of piping facilities pursuant to the provisions of Article 43, Paragraph 7 of the Enforcement Decree, the provisions of Article 17 and Article 18 of the Rules on Standards for Building Facilities, etc. shall apply mutatis mutandis.
[Wholly Revised 1997.7.21]
Article 11 (Exhaust Facilities) Exhaust facilities installed in kitchens, bathrooms, and toilets of residential buildings pursuant to Article 44 of the Enforcement Decree shall comply with each of the following subparagraphs. <Amended Nov. 5, 2009; Mar. 17, 2015; Jan. 12, 2021>
1. The exhaust vent shall be installed at a height of no more than 80 centimeters above or below the ceiling, and shall be constructed to be able to be kept open at all times.
2. The exhaust pipe and exhaust port shall be constructed in such a way that exhaust is not obstructed by the airflow of the outside air.
3. The exhaust pipe shall not have any openings except for its uppermost part and the exhaust port.
4. The uppermost part of the exhaust pipe shall be directly open to the outside air, but shall be equipped with facilities to block rainwater, etc.
5. Install an electric ventilation system in the exhaust vent installed in the kitchen
6. The exhaust pipe shall be constructed in a manner corresponding to any of the following items to prevent smoke, odors, etc. from flowing back into the room.
a. Install an automatic backflow prevention damper (referring to a device structured to automatically open or close by electric or mechanical force when the exhaust vent inside the unit opens or the electric ventilation system operates, and must be a product with performance compliant with the group standards under Article 27 of the Industrial Standardization Act) or an exhaust system device with the same function in the exhaust pipe inside the unit.
B. Install so that exhaust pipes between households are not connected to each other and open directly to the outside air.
Article 12 (Trunk Facilities)
① The installation standards for access roads (including trunk roads adjacent to the relevant site; hereinafter the same applies in this Article), water supply and sewage facilities, and electrical facilities, which are trunk facilities pursuant to the provisions of Article 57 of the Enforcement Decree, are as follows: <Amended Jan. 30, 2026>
1. Access Road
A. Access roads must ensure a road width equal to or greater than the standards specified in the following table.
<img src="http://www.law.go.kr/flDownload.do?flSeq=22558896" alt="img22558896" >
(Unit: Meter)
┌────────┬──────────────────────┐
Site area Width adjacent to main road or width of access road
├────────┼──────────────────────┤
Less than 20,000 square meters 8 or more
│ │ │
20,000 square meters or more 12 or more
Less than 40,000 square meters
│ │ │
40,000 square meters or more 15 or more
Less than 80,000 square meters
│ │ │
80,000 square meters or more 20 or more
└────────┴──────────────────────┘
</img>
B. If there are two or more access roads that meet the standards set forth in the following table, the provisions of A. may not apply. In this case, a road with a width of less than 6 meters shall be deemed an access road only if it is within 200 meters of the main road in terms of travel distance.
<img src="http://www.law.go.kr/flDownload.do?flSeq=22558897" alt="img22558897" >
(Unit: Meter)
┌────────┬───────────────────────────┐
Site area Sum of the widths of two access roads among access roads with a width of 4 meters or more
├────────┼───────────────────────────┤
Less than 20,000 square meters 12 or more
│ │ │
20,000 square meters or more 16 or more
Less than 40,000 square meters
│ │ │
40,000 square meters or more 20 or more
Less than 80,000 square meters
│ │ │
80,000 square meters or more 25 or more
└────────┴───────────────────────────┘
</img>
2. Water Supply Facilities
Water supply facilities must be capable of supplying a daily water volume of at least 0.1 tons per square meter of site area to the relevant site.
3. Sewerage Facilities
Sewerage facilities must be capable of treating at least 0.1 tons of wastewater per day per square meter of site area.
4. Electrical Facilities
The electrical facilities must be transmission facilities capable of supplying at least 35 watts of power per square meter of site area to the relevant site.
② Notwithstanding the provisions of Paragraph 1, if a plan regarding the planned number of housing units, etc. is included in a land development project plan pursuant to Article 15 of the Act, the standards for access roads, etc. may be in accordance with the following subparagraphs. <Amended Sep. 29, 1999; Dec. 15, 2003; Aug. 12, 2016; Jan. 30, 2026>
1. Access road: In accordance with the provisions of Article 25 of the Enforcement Decree.
2. Water Supply and Sewerage Facilities: The supply and treatment capacities must each be at least 1 ton per household per day.
3. Electrical Facilities: The transmission facilities must be capable of supplying at least 3 kilowatts of power to the relevant site per household (in cases where the exclusive area per household is 60 square meters or more, the value calculated by adding 0.5 kilowatts for every 10 square meters exceeding 60 square meters to 3 kilowatts).
Article 12-2 (Display of Multi-Family Housing Performance Grade) In the part other than the subparagraphs of Article 39 of the Act, the term "method prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" refers to the method of obtaining a Multi-Family Housing Performance Grade Certificate in the form of Annex No. 1 and displaying it in the notice of recruitment of residents pursuant to Articles 19 through 21 of the Rules on Housing Supply. In this case, the Multi-Family Housing Performance Grade Certificate must be displayed in an easily recognizable location with an easily legible font size. <Amended Dec. 29, 2015; Aug. 12, 2016; Jan. 16, 2019>
[This Article Newly Established 2014.6.30]
[Formerly Article 12-2 moved to Article 12-3 <2014.6.30>]
Article 12-3 (Application for Designation of Floor Impact Sound Performance Grade Certification Agency)
① Delete <2013.2.22>
② The application form for designation as an institution accredited for floor impact sound performance grades pursuant to Article 60-2, Paragraph 1 of the Enforcement Decree shall be in accordance with Form No. 1-2 of the Attached Subparagraph. <Amended July 15, 2013>
[This Article Newly Established 2008.9.25]
[Title Revised 2013.2.22]
[Moved from Article 12-2 <2014.6.30>]
Article 12-4 (Quality Management Standards for Products with Recognized Floor Impact Sound Performance Grades) In Article 41, Paragraph 2, Subparagraph 3 of the Act, the term "quality management standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" refers to standards for quality management regarding matters falling under each of the following subparagraphs concerning products that have received recognition for a floor impact sound performance grade from a floor impact sound performance grade recognition agency pursuant to Article 41, Paragraph 1 of the Act (hereinafter referred to as "recognized products"). In this case, the Minister of Land, Infrastructure and Transport may determine and publicly announce detailed matters concerning such quality management standards. <Amended Aug. 12, 2016; Aug. 4, 2022>
1. Quality control of raw materials constituting approved products
2. Quality Control of Manufacturing Process for Approved Products
3. Maintenance and Management of Manufacturing and Inspection Facilities for Approved Products
4. Quality Control of Finished Certified Products
[This Article Newly Established 2014.12.24]
Article 12-5 (Application for Designation of Floor Impact Sound Performance Inspection Agency) In the first part other than the subparagraphs of Article 60-9, Paragraph 2 of the Enforcement Decree, the term "application form prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" refers to the Application for Designation of a Floor Impact Sound Performance Inspection Agency in Form No. 1-3 of the Appendix. <Amended Jan. 30, 2026>
[This Article Newly Established 2022.8.4]
Article 13 (Performance and Production Standards for Industrialized Housing) The performance and production standards for industrialized housing pursuant to Article 51, Paragraph 1 of the Act (hereinafter referred to as "industrialized housing") are as set forth in Attached Table 6. <Amended Sep. 29, 1999; Dec. 15, 2003; Aug. 12, 2016; May 6, 2026>
[This Article Newly Established 1993.7.20]
[Former Article 13 deleted, moved from Article 22-2 <1999.9.29>]
Article 14 (Constructor of Industrialized Housing Not Subject to Design and Supervision by an Architect) In Article 53, Paragraph 2 of the Act, the phrase "a person possessing technical capabilities prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" refers to a person who holds at least one architect under the Architects Act and at least one Professional Engineer in Structural Engineering or Professional Engineer in Construction under the National Technical Qualifications Act.
[Wholly Revised 2026.5.6]
Article 15 (Application for Recognition of Industrialized Housing, etc.)
① Any person who intends to obtain recognition of an industrialized housing pursuant to Article 61-2, Paragraph 1 of the Enforcement Decree shall submit an application for recognition of industrialized housing in the form of Annex 1-4 to the Minister of Land, Infrastructure and Transport.
② The Certificate of Recognition for Industrialized Housing pursuant to Article 61-2, Paragraph 3 of the Enforcement Decree shall be in accordance with Form No. 2 of the Attached Form.
③ A person who has been issued a Certificate of Recognition for Industrialized Housing pursuant to Paragraph 3 of Article 61-2 of the Enforcement Decree shall, in the event that any of the matters in the following subparagraphs are changed pursuant to Paragraph 4 of the same Article, submit an Application for Change of Recognition for Industrialized Housing in the form of Annex 1-4 to the Minister of Land, Infrastructure and Transport within 30 days from the date of such change, attaching the Certificate of Recognition for Industrialized Housing in the form of Annex 2, the details of the change pursuant to the first part of Paragraph 4 of Article 61-2 of the Enforcement Decree, and documents capable of proving such change.
1. Factory Location
2. Performance of industrialized housing (referring to the performance level confirmed by quality certifications, test reports, etc., regarding the performance standards pursuant to Item 1 of Annex 6, and the validity period, etc.)
3. Production Facilities for Industrialized Housing
④ Any person who wishes to obtain a reissuance of the Certificate of Recognition for Industrialized Housing pursuant to Paragraph 2 due to falling under any of the following subparagraphs shall submit an application for reissuance of the Certificate of Recognition for Industrialized Housing in the form of Annex 3 to the Minister of Land, Infrastructure and Transport.
1. In case the Certificate of Recognition for Industrialized Housing is lost or damaged
2. In case the trade name, designation, or representative's name has been changed
⑤ Any person who intends to extend the validity period of the recognition of industrialized housing pursuant to Article 61-3, Paragraph 2 of the Enforcement Decree shall submit to the Minister of Land, Infrastructure and Transport an application for extension of the recognition validity period in the form of Annex 1-4, attaching the certificate of recognition of industrialized housing in the form of Annex 2.
⑥ A person who has been issued a Certificate of Recognition for Industrialized Housing pursuant to Paragraphs 3 and 4 of Article 61-2 of the Enforcement Decree shall submit a Report on the Production and Construction Performance of Industrialized Housing in the form of Annex 4 to the Minister of Land, Infrastructure and Transport by January 15 of each year, pursuant to Paragraph 1 of Article 61-4 of the Enforcement Decree.
[Wholly Revised 2026.5.6]
Article 16 (Application for Long-Life Housing Certification, etc.)
① In the case where a project entity pursuant to Subparagraph 10 of Article 2 of the Act (hereinafter referred to as the "Project Entity") constructs multi-unit housing with 1,000 or more households, it shall apply for Long-Life Housing Certification before applying for approval of the housing construction project plan pursuant to Article 15, Paragraph 1 of the Act. <Amended Aug. 12, 2016>
② In order for a project owner to obtain certification for a long-life housing, they shall submit an application for certification of a long-life housing in the form of Annex 5 (including an application in the form of an electronic document) to the head of the certification body pursuant to Article 65-2, Paragraph 4 of the Enforcement Decree (hereinafter referred to as the "head of the certification body"), attaching the documents specified in each of the following subparagraphs (including electronic documents).
1. Self-assessment report for long-life housing prescribed and notified by the Minister of Land, Infrastructure and Transport
2. Documents proving that the contents included in the self-assessment report of the long-life housing pursuant to Item 1 are true
③ The head of the certification body shall process the certification within 10 days from the date the application under Paragraph 2 is received.
4. If the head of the certification body has unavoidable reasons preventing the processing of certification within the period under Paragraph 3, he/she shall notify the project entity of such reasons and may extend the certification processing period once within a range of 5 days.
⑤ If the contents of the documents submitted by the project entity pursuant to Paragraph 2 are insufficient or differ from the facts, the head of the certification body may request the project entity to supplement the documents within 5 days from the date of receipt. In this case, the period during which the project entity supplements the submitted documents shall not be included in the period specified in Paragraph 3.
[This Article Newly Established 2014.12.24]
Article 17 (Examination for Long-Life Housing Certification, etc.)
① Upon receiving an application for certification pursuant to Article 16, Paragraph 2, the head of the certification body shall constitute a certification review team, conduct a document review in accordance with the certification standards of Article 18, and determine whether to grant certification and the certification grade by considering the review contents and scores, etc.
② Notwithstanding Paragraph 1, if the head of the certification body deems it necessary, the eligibility for certification and the certification grade may be determined through deliberation by the Certification Deliberation Committee. In this case, members of the Certification Deliberation Committee must not be persons affiliated with the relevant certification body.
③ The certification audit team under Paragraph 1 shall be composed of at least one auditing expert for each relevant specialized field.
④ Matters necessary for the composition and operation, etc. of the Certification Review Team under Paragraph 1 and the Certification Deliberation Committee under Paragraph 2 shall be determined by the Minister of Land, Infrastructure and Transport and announced by public notice.
[This Article Newly Established 2014.12.24]
Article 18 (Certification Standards for Long-Life Housing)
① Certification of long-life housing shall be reviewed based on the comprehensive score obtained by evaluating the performance of each of the following subparagraphs. <Amended Mar. 6, 2025>
1. Durability considering the following items for each housing structure
A. In the case of reinforced concrete structures: Concrete quality and rebar cover thickness, etc.
B. In the case of steel frame structures: Corrosion resistance performance of steel, etc.
2. Variability of wall materials and arrangement of piping and columns, etc.
3. Repairability, including ease of modification, maintenance, and inspection
② Detailed matters concerning the certification standards for long-life housing pursuant to Paragraph 1 shall be determined and announced by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2014.12.24]
Article 19 (Issuance of Long-Life Housing Certificates, etc.)
① When certifying a long-life housing, the head of the certification body shall issue a long-life housing certification in the form of Annex 6 to the project owner.
② If the project entity makes a change to the housing construction project plan that alters the certification grade after receiving the Long-Life Housing Certification pursuant to Paragraph 1, it must obtain the Long-Life Housing Certification again.
③ When the head of the certification body has issued a certificate pursuant to Paragraph 1, he/she shall prepare and retain certification audit results including the subject of certification, the certification date, the certification grade, and the list of members of the certification audit team and the certification audit committee (in the case of the certification audit committee, this applies only if the committee has been constituted).
[This Article Newly Established 2014.12.24]
Article 20 (Request for Re-examination, etc.)
① A project owner who has an objection to the certification grade of a long-life housing certificate issued pursuant to Article 19, Paragraph 1, may request a re-examination from the head of the certification body.
② Detailed matters concerning re-examination, such as procedures for requesting re-examination, notification of re-examination results, and reissuance of certificates, shall be determined and announced by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2014.12.24]
Article 21 (Certification Fee)
① When submitting an application for certification of a long-life housing pursuant to Article 16, Paragraph 2, the project owner shall pay the certification fee prescribed and notified by the Minister of Land, Infrastructure and Transport to the head of the relevant certification body.
② A project entity applying for re-examination pursuant to Article 20, Paragraph 1 shall pay an additional certification fee prescribed and notified by the Minister of Land, Infrastructure and Transport.
③ The certification fees pursuant to Paragraphs 1 and 2 shall be paid in cash or by means such as electronic money or electronic payment using an information and communications network.
④ The grounds for refund, scope of return, payment period, and other matters necessary for the payment of certification fees pursuant to Paragraphs 1 through 3 shall be determined by the Minister of Land, Infrastructure and Transport and announced by public notice.
[This Article Newly Established 2014.12.24]
Article 22 (Relaxation of Building Coverage Ratio, etc. for Long-Life Housing) The phrase "grade equal to or higher than the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport" in Article 38, Paragraph 7 of the Act refers to a grade of "Excellent" or higher among the certification grades under Article 65-2, Paragraph 1 of the Enforcement Decree. <Amended Aug. 12, 2016>
[This Article Newly Established 2014.12.24]
Article 22-2
[Formerly Article 22-2 moved to Article 13 <1999.9.29>]
Article 22-3
[Formerly Article 22-3 moved to Article 14 <1999.9.29>]
Article 22-4
[Formerly Article 22-4 moved to Article 15 <1999.9.29>]
Article 23 Deleted <1999.9.29>
Article 24 Deleted <1999.9.29>
Article 25 Deleted <1999.9.29>
Article 26 Deleted <1999.9.29>
Article 27 Deleted <1999.9.29>
■ Rules on Housing Construction Standards, etc. [Attachment Form No. 1] <Amended June 30, 2023>
┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
Multi-unit Housing Performance Grade Certificate
1. Apartment Name:
2. Applicant:
3. Site Location:
4. Performance Grade
┃ ┃
A. Noise-related rating C. Environmental-related rating
┃ ┌───────────────────────┬────┐ ┌─────────────────────┬────┐ ┃
Performance Item Performance Grade Performance Item Performance Grade
┃ ├───────────────────────┼────┤ ├─────────────────────┼────┤ ┃
1. Lightweight impact sound insulation performance 20. Creation of linked green axes
┃ ├───────────────────────┼────┤ ├─────────────────────┼────┤ ┃
2. Impact Sound Insulation Performance 21. Natural Ground Greenness Ratio
┃ ├───────────────────────┼────┤ ├─────────────────────┼────┤ ┃
3. Sound insulation performance of boundary walls between households 22. Ecological area ratio
┃ ├───────────────────────┼────┤ ├─────────────────────┼────┤ ┃
4. Indoor and outdoor noise regarding traffic noise (roads, railways) 23. Creation of biological habitats (biotopes)
also
24. Application of Low Indoor Air Pollutant Emission Products
5. Bathroom water supply and drainage noise
25. Ensuring Natural Ventilation Performance
┃ ├─────────────────────┼────┤ ┃
B. Structural Grades 26. Ensuring Ventilation Performance for Unit Households
┃ ┌────────────┬────┐ ├─────────────────────┼────┤ ┃
Performance Item Performance Grade 27. Temperature Control System Installation Level
┃ ├────────────┼────┤ └─────────────────────┴────┘ ┃
1. Durability
D. Rating related to living environment
2. Variability
Performance Item Performance Grade
3. Repairability Dedicated Parts
1. Creation of pedestrian-only roads within and outside the complex and annual
4. Repairability Common Areas Conclusion
┃ └────────────┴────┘ ├──────────────────────┼────┤ ┃
2. Proximity to Public Transportation
C. Environmental Rating
3. Suitability of Bicycle Parking Lots and Bicycle Paths
Performance Item Performance Grade
4. Accessibility to daily amenities
1. Ecological Value of the Existing Site
5. Environmental Management Plan for Construction Sites
2. Avoid excessive underground development
6. Provision of Operation and Maintenance Documents and Manuals
3. Earthwork Cut and Embankment Volume (Earth Excavation and Embankment
Amount) Minimize 7. User manual provided
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
4. Validity of measures to prevent interference with sunlight rights 8. Provision of information related to Green Building Certification
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
5. Energy Performance 9. Consideration for the Socially Vulnerable in Unit Households
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
6. Energy monitoring and management support devices 10. Consideration for the socially vulnerable in common spaces
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
7. Use of New and Renewable Energy 11. Standard of Development for Community Centers and Facility Spaces
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
8. Application of low-carbon energy source technology 12. Sunlight securing rate within household
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
9 Ban on the use of specific substances for the protection of the ozone layer 13. Home Network Integrated System
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
10. Use of Environmentally Declared Products (EPD) 14. Crime Prevention & Safety Content
┃ ├───────────────────────┼────┤ ├──────────────────────┼────┤ ┃
11. Use of low-carbon materials 15. Securing additional parking spaces
┃ ├───────────────────────┼────┤ └──────────────────────┴────┘ ┃
12. Use of Circular Resource Materials
E. Fire and Firefighting Related Grades
13. Use of materials for reducing hazardous substances
Performance Item Performance Grade
14. Application Rate of Green Building Materials
1. Detection and Alarm Equipment
15. Installation of Storage Facilities for Recyclable Resources
2. Smoke Control System
16. Rainwater Management
3. Fire Resistance Performance
17. Use of rainwater and groundwater runoff
4. Horizontal Evacuation Distance
18. Use water-saving devices
5. Effective width of corridors and stairs
19. Water Usage Monitoring
6. Evacuation Facilities
┃ └─────────────┴────┘ ┃
┃ ┃
Article 16 of the "Act on Support for the Creation of Green Buildings," Article 11 of the "Rules on Green Building Certification," and the "Housing Act"
Pursuant to Article 39, the Multi-unit Housing Performance Grade Certificate is hereby issued as stated above.
Year Month Day
┃ ┏━━┓ ┃
Seal of the Head of the Certification Body
┃ ┗━━┛ ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
210mm×297mm[white paper 120g/㎡]
Original file: /LSW/flDownload.do?flSeq=167515783
Original file: /LSW/flDownload.do?flSeq=167515785
Original file: /LSW/flDownload.do?flSeq=167515787
■ Rules on Housing Construction Standards, etc. [Form No. 1-2] <Amended Jul. 15, 2013>
Application for Designation as Floor Impact Sound Performance Grade Accreditation Agency
──────────┬────────────────────────┬────────────
Receipt No. Receipt Date Processing Period 20 days
──────────┴────────────────────────┴────────────
─────┬───────────┬──────────────────────────────
Applicant Company Name Business Registration Number
├───────────┼──────────────────────────────
Representative's Date of Birth
├───────────┼──────────────────────────────
Business Location Phone Number/Fax
─────┴───────────┴──────────────────────────────
Designation of Floor Impact Sound Performance Grade Accreditation Agency Pursuant to Article 60-2, Paragraph 1 of the "Regulations on Housing Construction Standards, etc."
.
Year Month Day
Applicant (Signature or Seal)
To the Minister of Land, Infrastructure and Transport
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
───────┬──────────────────────────────────┬─────
Applicant 1. Executive Register Fee
Submission Documents 2. No documents proving personnel and equipment standards
3. Implementation Plan for Floor Impact Sound Performance Grade Certification Work
───────┼──────────────────────────────────┤
Responsible Public Official Certificate of Corporate Registration
Checklist
───────┴──────────────────────────────────┴─────
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Processing procedure
────────────────────────────────────────────────
┌──────┐ ┌──┐ ┌──┐ ┌─────┐
Application Submission ? Receipt ? Review ? Designation Notification
└──────┘ └──┘ └──┘ └─────┘
Applicant Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport
────────────────────────────────────────────────
210mm×297mm[White Paper 80g/㎡ (Recycled)]
Original file: /LSW/flDownload.do?flSeq=167515789
Original file: /LSW/flDownload.do?flSeq=167515791
Original file: /LSW/flDownload.do?flSeq=167515793
■ Rules on Housing Construction Standards, etc. [Form No. 1-3] <Amended Jan. 30, 2026>
Application for Designation as Floor Impact Sound Performance Inspection Agency
※ The applicant does not need to fill out the dark-colored boxes.
─────────┬─────────┬─────────────────────────────────────────
Receipt No. Receipt Date Processing Period 20 days
─────────┴─────────┴─────────────────────────────────────────
─────┬────────────┬──────────────────────────────────────────
Applicant's Business Name Business Registration Number
├────────────┼──────────────────────────────────────────
Representative Phone Number/Fax
├────────────┴──────────────────────────────────────────
Business Location
─────┴───────────────────────────────────────────────────────
Pursuant to Article 41-2, Paragraph 2 of the Housing Act and Article 60-9, Paragraph 2 of the Regulations on Housing Construction Standards, etc., floor layer
I am applying for designation as a sound acument performance testing agency.
Year Month Day
Applicant (Signature or Seal)
To the Minister of Land, Infrastructure and Transport
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
───────┬───────────────────────────────────────────────┬─────
Applicant 1. Fee proving compliance with the personnel and equipment standards pursuant to Annex 6 of the "Regulations on Housing Construction Standards, etc."
Submitted Documents No Documents
2. Implementation Plan for Performance Inspection of Floor Impact Sound Insulation Structures
───────┼───────────────────────────────────────────────┤
Responsible Public Official Certificate of Corporate Registration
Checklist
───────┴───────────────────────────────────────────────┴─────
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Processing procedure
─────────────────────────────────────────────────────────────
┌──────┐ ┌──┐ ┌──┐ ┌─────┐
Application Submission ? Receipt ? Review ? Designation Notification
└──────┘ └──┘ └──┘ └─────┘
Applicant Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport
─────────────────────────────────────────────────────────────
210mm×297mm[White Paper 80g/㎡ (Recycled)]
Original file: /LSW/flDownload.do?flSeq=167515795
Original file: /LSW/flDownload.do?flSeq=167515797
Original file: /LSW/flDownload.do?flSeq=167515799
Application for Industrialized Housing (Approval, Modified Approval, Extension of Approval Validity Period)
■ Rules on Housing Construction Standards, etc. [Form No. 1-4] <Amended May 6, 2026>
Application for Recognition of Industrialized Housing [ ]
[ ] Change Acknowledged
[ ] Extension of Recognition Validity Period
※ Mark the appropriate box in [ ]. (Front)
────────┬───────┬──────────────────────────────────
Receipt No. Receipt Date Processing Period 60 days
────────┴───────┴──────────────────────────────────
━━━━━━┯━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Applicant's Business Name or Designation Business Registration Number
├─────────┼──────────────────────────────────
Representative Name Date of Birth
├─────────┼──────────────────────────────────
Factory Location Phone Number
├─────────┴──────────────────────────────────
Capital or property
━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
※ Fill out only applicable items.
━━━━━━┯━━━━┯━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Name and dimensions of the housing for which approval is requested
Overview
Main Constituent Materials Usage Area
│ ├─────┼─────────────────────────────────
Structure Type Production Capacity
━━━━━━┷━━━━┷━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━┯━━━━┯━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Change Approved Change Date Before Change After Change
Apply
│ │ │
━━━━━━┷━━━━┷━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━┯━━━━┯━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Validity Period Industrialized Housing Recognition Number Recognition Date
Extension Application Approval Details
Name of the house
├────┼───────────────────────────────────────
Extension Period
├────┼───────────────────────────────────────
Reason for extension
━━━━━━┷━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Article 51, Paragraph 1 of the Housing Act, Article 61-2, Paragraphs 1 and 4, and Article 61-3, Paragraph 2 of the Regulations on Housing Construction Standards, etc., and
I hereby apply as stated above in accordance with Article 15, Paragraphs 1, 3, and 5 of the "Rules on Housing Construction Standards, etc."
Year Month Day
Applicant (Signature or Seal)
To the Minister of Land, Infrastructure and Transport
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
───────┬───────────────────────────────────────────
Refer to back of attachments
───────┴───────────────────────────────────────────
210mm×297mm[Standard Paper 60g/㎡ (Recycled)]
(Back)
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━┯━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Application for Recognition of Attached Documents 1. Design and Product Description (1 copy).
2. One copy each of design drawings, fabrication drawings, and specifications
3. Test report regarding structure and performance or certificate of structural safety (Professional Engineer in the field of architectural structures
applies only to those prepared after confirming that structural safety performance evaluation is possible) 1 copy.
4. One copy of the document specifying the production process, construction process, production capacity, and quality control plan.
├─────┼───────────────────────────────────────
Recognition of Change 1. Article 51, Paragraph 1 of the Housing Act and Article 61-2, Paragraph 3 of the Regulations on Housing Construction Standards, etc.
│Application │Certificate of Recognition for Industrialized Housing pursuant to Item
2. Details of the change pursuant to the first part of Article 61-2, Paragraph 4 of the "Regulations on Housing Construction Standards, etc." and
Documents proving this
├─────┼───────────────────────────────────────
Validity Period Article 51, Paragraph 1 of the "Housing Act" and Article 61-3, Paragraph 2 of the "Regulations on Housing Construction Standards, etc."
Certificate of Recognition for Industrialized Housing Following Application for Extension
─────┴─────┴───────────────────────────────────────
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Processing procedure
───────────────────────────────────────────────────
┌──────┐ ┌───┐ ┌───┐ ┌─────────┐ ┌────────┐
Application Form Submission ? Submission ? Review ? Certificate of Industrialized Housing ? Industrialized Housing Recognition
Issuance Notice
└──────┘ └───┘ └───┘ └─────────┘ └────────┘
Applicant Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport
───────────────────────────────────────────────────
210mm×297mm[Standard Paper 60g/㎡ (Recycled)]
Original file: /LSW/flDownload.do?flSeq=167515801
Original file: /LSW/flDownload.do?flSeq=167515803
Original file: /LSW/flDownload.do?flSeq=167515805
Original file: /LSW/flDownload.do?flSeq=167515807
■ Rules on Housing Construction Standards, etc. [Attachment Form No. 2] <Amended May 6, 2026>
┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃ ┃
┃ ┃
Recognition No.
┃ ┃
Certificate of Industrialized Housing
┃ ┃
1. Trade Name or Designation
2. Representative's Name
3. Factory Location
4. Name of Industrialized Housing
5. Major Constituent Materials
6. Area of Use
7. Validity Period: From to
┃ ┃
Article 51, Paragraph 1 of the Housing Act and Article 61-2 of the Regulations on Housing Construction Standards, etc.
I hereby certify that it has been recognized as an industrialized housing in accordance with Paragraph 3.
┃ ┃
Year Month Day
┃ ┃
┃ ┃
┃ ┏━━┓ ┃
Official Seal of the Minister of Land, Infrastructure and Transport
┃ ┗━━┛ ┃
┃ ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
210mm×297mm[Preservation Paper 120g/㎡]
Original file: /LSW/flDownload.do?flSeq=167515809
Original file: /LSW/flDownload.do?flSeq=167515811
Original file: /LSW/flDownload.do?flSeq=167515813
■ Rules on Housing Construction Standards, etc. [Attachment Form No. 3] <Amended May 6, 2026>
Application for Reissuance of Industrialized Housing Certificate
─────────────┬─────────────────────┬─────────
Receipt No. Receipt Date Processing Period Immediate
─────────────┴─────────────────────┴─────────
─────┬───────────────┬───────────────────────
Applicant's Business Name or Designation Business Registration Number
├───────────────┼───────────────────────
Representative Name Date of Birth
├───────────────┴───────────────────────
Address (Location for corporations)
─────┴───────────────────────────────────────
─────┬──────┬────────┬───────────────────────
Application Details Industrialized Housing Recognition Number Recognition Date
Acknowledgements
Name of the house
├──────┼────────────────────────────────
Reason for Application
─────┴──────┴────────────────────────────────
I hereby apply for the reissuance of the Certificate of Recognition for Industrialized Housing pursuant to Article 15, Paragraph 4 of the "Rules on Housing Construction Standards, etc."
.
Year Month Day
Applicant (Signature or Seal)
To the Minister of Land, Infrastructure and Transport
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
──────┬──────────────────────────────┬───────
No attachments Fee
None
──────┴──────────────────────────────┴───────
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Processing procedure
─────────────────────────────────────────────
┌──────┐ ┌───┐ ┌───┐ ┌──────────┐
Application Form Completion ? Submission ? Review ? Industrialized Housing Certification Re-
Issue
└──────┘ └───┘ └───┘ └──────────┘
Applicant Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport Ministry of Land, Infrastructure and Transport
─────────────────────────────────────────────
210mm×297mm[Standard Paper 70g/㎡ (Recycled)]
Original file: /LSW/flDownload.do?flSeq=167515815
Original file: /LSW/flDownload.do?flSeq=167515817
Original file: /LSW/flDownload.do?flSeq=167515819
■ Rules on Housing Construction Standards, etc. [Attachment Form No. 4] <Amended Apr. 3, 2012>
Production and Construction Performance of Industrialized Housing
(Unit: )
┏━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
Recognition Number Housing Name
┠─────────┼──────────────────────────────────────────────┨
Company Name or Designation Business Registration Number
┠─────────┼──────────────────────────────────────────────┨
Representative's Date of Birth
┗━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
┏━━━━┯━━━━┯━━━━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━┓
Part Name Production Quantity Construction Actual Remarks
┣━━━━┿━━━━┿━━━━━━━━━━━━━━━━━━━━━━┿━━━━━━━━━━━━━━━━━━━━━━━┫
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┠────┼────┼──────────────────────┼───────────────────────┨
┃ │ │ │ ┃
┗━━━━┷━━━━┷━━━━━━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━┛
※ If there is a track record of self-construction, indicate ( ) in the Construction Track Record column.
210mm×297mm[Newspaper Paper (Grade 2) 64g/㎡]
Original file: /LSW/flDownload.do?flSeq=167515821
Original file: /LSW/flDownload.do?flSeq=167515823
Original file: /LSW/flDownload.do?flSeq=167515825
■ Rules on Housing Construction Standards, etc. [Attachment Form No. 5] <Newly Inserted Dec. 24, 2014>
Application for Long-Life Housing Certification
───────────┬───────────────────┬────────────────────────────
Receipt No. Receipt Date Processing Period Within 10 days
───────────┴───────────────────┴────────────────────────────
──────┬───────────────────────┬─────────────────────────────
Business Entity Trade Name Registration Number
├───────────────────────┼─────────────────────────────
Representative's Date of Birth (Corporate Registration Number)
├───────────────────────┴─────────────────────────────
Business Location
(Phone Number : )
├────┬──────────────────┬────────────┬────────────────
Working Name Department Position
Person in Charge
Phone Number Fax Number Email
──────┴────┴──────────────────┴────────────┴────────────────
──────┬───────────────────────┬─────────────────────────────
Designer Name Credential Number
(Signature or Seal)
├───────────────────────┼─────────────────────────────
Office Name Registration Number
├───────────────────────┴─────────────────────────────
Office Location
(Phone Number: )
──────┴─────────────────────────────────────────────────────
──────┬───────────────────────┬─────────────────────────────
Site Conditions Building Name Site Location
├───────────────────────┼─────────────────────────────
Zoning Area Zoning District
├───────────────────────┼─────────────────────────────
Land Category Area (㎡)
──────┴───────────────────────┴─────────────────────────────
──────┬───────────────────────┬─────────────────────────────
Scale Building Area (㎡) Building Coverage Ratio (㎡)
├───────────────────────┼─────────────────────────────
Gross Floor Area (㎡) Gross Floor Area (㎡) for Floor Area Ratio Calculation
├───────────────────────┼─────────────────────────────
Floor Area Ratio (㎡) Height (m)
──────┴───────────────────────┴─────────────────────────────
Pursuant to Article 21-6 of the Housing Act and Article 16, Paragraph 2 of the Rules on Housing Construction Standards, etc., the new long-life housing certification
.
Year Month Day
Project Entity (Signature or Seal)
Application Receiving Agency (Name of Receiving Department and Recipient)
To the Head of the Certification Body
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
─────┬───────────────────────────────────────────┬──────────
Attachment 1. Fee for the self-assessment report on long-life housing prescribed and notified by the Minister of Land, Infrastructure and Transport
2. Documents proving that the contents included in the self-assessment report of the long-life housing pursuant to Item 1 are true
The Minister of Land, Infrastructure and Transport
Noticed Amount
─────┴───────────────────────────────────────────┴──────────
Processing Procedure: Application Form Submission ? Receipt ? Review ? Approval ? Applicant for Certificate Issuance Certification Body Certification Body Certification Body (Certification Processing Department) (Certification Processing Department (Certification Processing Department) Office) 210mm×297mm [White paper 80g/㎡ (Recycled)] Original File: /LSW/flDownload.do?flSeq=167515827 Original File: /LSW/flDownload.do?flSeq=167515829 Original File: /LSW/flDownload.do?flSeq=167515831 ■ Rules on Housing Construction Standards, etc. [Attachment Form No. 6] <Newly Added 2014.12.24.> Long-Life Housing Certificate 1. Certification Number: 2. Applicant (Project Owner): 3. Building Name: 4. Site Location: 5. Certification Grade: Performance Category Score Grade 1) Durability Score ☆☆☆☆ 2) Adaptability Score ☆☆☆☆ 3) Repairability Exclusive Score ☆☆☆☆ Common Score ☆☆☆☆ Overall Score (1 + 2 + 3) Total Score out of 100 □Excellent □Good □Fair □General In accordance with Article 21-6 of the Housing Act and Article 19, Paragraph 1 of the Rules on Housing Construction Standards, etc., a Long-Life Housing Certificate is hereby issued as above. Year Month Day Seal of the Head of the Certification Agency
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
210mm×297mm[White Paper 80g/㎡ (Recycled)]
Original file: /LSW/flDownload.do?flSeq=167515833
Original file: /LSW/flDownload.do?flSeq=167515835
Original file: /LSW/flDownload.do?flSeq=167515837
Delete <1999.9.29>
[Form 7] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515839
Original file: /LSW/flDownload.do?flSeq=167515841
Original file: /LSW/flDownload.do?flSeq=167515843
Delete <1999.9.29>
[Form 8] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515845
Original file: /LSW/flDownload.do?flSeq=167515847
Original file: /LSW/flDownload.do?flSeq=167515849
Delete <1999.9.29>
[Form 9] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515851
Original file: /LSW/flDownload.do?flSeq=167515853
Original file: /LSW/flDownload.do?flSeq=167515855
Delete <1995.2.23>
[Form 10] Delete <1995.2.23>
Original file: /LSW/flDownload.do?flSeq=167515857
Original file: /LSW/flDownload.do?flSeq=167515859
Original file: /LSW/flDownload.do?flSeq=167515861
Delete <1999.9.29>
[Form 11] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515863
Original file: /LSW/flDownload.do?flSeq=167515865
Original file: /LSW/flDownload.do?flSeq=167515867
Delete <1999.9.29>
[Form 12] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515869
Original file: /LSW/flDownload.do?flSeq=167515871
Original file: /LSW/flDownload.do?flSeq=167515873
Delete <1999.9.29>
[Form 13] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515875
Original file: /LSW/flDownload.do?flSeq=167515877
Original file: /LSW/flDownload.do?flSeq=167515879
Delete <1999.9.29>
[Format 14] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515881
Original file: /LSW/flDownload.do?flSeq=167515883
Original file: /LSW/flDownload.do?flSeq=167515885
Delete <1999.9.29>
[Form 15] Delete <1999.9.29>
Original file: /LSW/flDownload.do?flSeq=167515887
Original file: /LSW/flDownload.do?flSeq=167515889
Original file: /LSW/flDownload.do?flSeq=167515891
Delete <1995.2.23>
[Form 16] Delete <1995.2.23>
Original file: /LSW/flDownload.do?flSeq=167515893
Original file: /LSW/flDownload.do?flSeq=167515895
Original file: /LSW/flDownload.do?flSeq=167515897
Revision
⊙Ministry of Land, Infrastructure and Transport Decree No. 1605
The Partial Amendment to the Rules on Housing Construction Standards, etc. is hereby promulgated as follows.
July 29, 2026
Minister of Land, Infrastructure and Transport (Seal)
Partial Amendment to the Rules on Housing Construction Standards, etc.
The Rules on Housing Construction Standards, etc. are partially amended as follows.
Article 6-2, Paragraph 1, Subparagraph 3, Item (b) shall be renumbered as Item (c), and Item (b) shall be newly added to the same subparagraph as follows; wherein in Item (c) of the same subparagraph (formerly Item (b), "the proviso to the part other than the items of Article 16-2, Paragraph 1, Subparagraph 1" shall be changed to "Article 16-2, Paragraph 1, Subparagraph 2, Item (c)."
B. In the case of a mechanical parking facility including an automatic transfer parking device pursuant to the part other than each item of Article 6, Paragraph 1, Subparagraph 11 of the Enforcement Rules of the Parking Lot Act, where the project plan approval authority recognizes that there is no impediment to the residential environment
Supplementary Provisions
Article 1 (Enforcement Date) This Rule shall enter into force on the date of its promulgation.
Article 2 (Applicability to Structure and Facilities of Parking Lots) The amended provisions of Article 6-2, Paragraph 1, Subparagraph 3, Item (b) shall apply from the time an application under each of the following subparagraphs is made after the enforcement of this Rule.
1. Application for approval of a business plan pursuant to Article 15, Paragraph 1 or 3 of the Act (in the case of approval for change pursuant to Paragraph 4 of the same Article, limited to prior to the public notice of resident recruitment)
2. Application for permission, authorization, approval, etc. under other laws where the approval under Subparagraph 1 is deemed to be granted
Article 3 (Amendment of Other Laws) Part of the Rules on the Calculation, etc. of Sale Prices of Multi-Unit Housing is amended as follows.
In Item 11 of Annex 1-3, "the proviso to Article 6-2, Item 2 of the 'Rules on Housing Construction Standards, etc.'" shall be changed to "the proviso to the part other than the items of Article 6-2, Paragraph 1, Item 2 of the 'Rules on Housing Construction Standards, etc.'".
Reason for Enactment/Amendment
[Partial revision]
◇ Reasons for Amendment and Key Contents
This is intended to allow the installation of mechanical parking lots equipped with a mechanical device that uses a parking robot to lift a vehicle or carrier after the driver exits and moves it to a parking space for parking, in order to secure parking spaces within multi-unit housing complexes, provided that the project plan approval authority approves it.