승강기 안전관리법 시행규칙

288485 · 2026-08-30

Ministry of the Interior and Safety (Elevator Policy Division), 044-205-4297 Chapter 1 General Provisions Article 1 (Purpose) This Rule prescribes matters delegated by the Elevator Safety Management Act and its Enforcement Decree and matters necessary for their implementation. Article 2 (Types of Elevators) The detailed types of elevators classified by structure or use pursuant to each subparagraph of Article 3, Paragraph 1 of the Enforcement Decree of the Elevator Safety Management Act (hereinafter referred to as the “Decree”) are as shown in Table 1 . Article 3 (Scope of Elevator Replacement) The term “elevator replacement within the scope prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 2, subparagraph 4 of the “Elevator Safety Management Act” (hereinafter referred to as the “Act”)refers to the replacement of an elevator in any of the following cases: 1. In the case of an elevator pursuant to Article 3 , Paragraph 1, Subparagraph 1 of the Enforcement Decree (hereinafter referred to as “elevator”) or a wheelchair lift pursuant to Subparagraph 3 of the same Paragraph (hereinafter referred to as “wheelchair lift”), if all elevator parts are replaced excluding elevator parts falling under any of the following subparagraphs a. Counterweight B. Machine stand c. Buffer support D. Driving guide rail E. Parts of the guide rail f. Door frames of entrances 2. In the case of an escalator pursuant to Article 3 , Paragraph 1, Subparagraph 2 of the Enforcement Decree (hereinafter referred to as “escalator”), if all elevator parts are replaced, excluding elevator parts falling under any of the following subparagraphs a. Frame structure (Truss) B. Parts of the frame structure C. Platform protection measures Chapter 2 Manufacturing or Importing of Elevators, etc. Article 4 (Application for Registration of Manufacturing or Importing Business, etc.) ① Any person who intends to register to engage in the manufacturing or importing business of elevators or elevator parts pursuant to Article 9 and Annex 2 of the Enforcement Decree (hereinafter referred to as “manufacturing or importing business”) pursuant to the first part of Article 6, Paragraph 1 of the Act shall submit the application for registration of manufacturing or importing business (including electronic documents) in Form No. 1 of the Attached Form, along with the documents (including electronic documents) listed in each of the following subparagraphs, to the Special City Mayor, Integrated Special City Mayor, Metropolitan City Mayor, Special Self-Governing City Mayor, Provincial Governor, or Special Self-Governing Provincial Governor having jurisdiction over the location of the principal office (hereinafter referred to as “City/Provincial Governor”). In this case, the City/Provincial Governor shall verify the business registration certificate through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act, and shall require the applicant to attach the relevant documents if the applicant does not consent to the verification. <Amended Sep. 7, 2021; Jul. 29, 2026> 1. Deleted <July 29, 2026> 2. Business Plan 3. Post-management plan for elevators or elevator parts to be manufactured or imported 4. Documents proving that the registration standards for manufacturing or importing business pursuant to Article 10 and Annex 1 of the Enforcement Decree have been met 5. If the applicant (in the case of a corporation, the representative of the corporation) is a foreigner, documents classified according to the following items that can confirm that the applicant does not fall under any of the grounds for disqualification specified in each subparagraph of Article 7 of the Act a. In the case of a country that has concluded the "Convention Abolishing the Requirement of Legalization for Foreign Public Documents": a document issued by the government or other competent authority of such country, or a statement of the relevant foreign national notarized by a notary public, for which an Apostille (Apostille: refers to a certificate issued by the Minister of Foreign Affairs or the Minister of Justice confirming the authenticity of a public document submitted to a country that has concluded the Convention Abolishing the Requirement of Legalization for Foreign Public Documents; hereinafter the same) has been issued by the authority in such country having the authority to issue such Apostilles. B. In the case of a country that has not concluded the "Convention Abolishing the Requirement of Legalization for Foreign Public Documents": a document issued by the government or other competent authority of the country concerned, or a statement of the relevant foreign national notarized by a notary public and verified by the Korean consul residing in the country concerned. ② In the latter part of Article 6, Paragraph 1 of the Act , “matters prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the matters in each of the following subparagraphs. 1. Trade name (in the case of a corporation, the name of the corporation. The same applies hereinafter) 2. Location of the principal office 3. Number and location of factories (referring to factories manufacturing elevators or elevator parts pursuant to Article 2, Subparagraph 1 of the Act on Promotion of Industrial Agglomeration and Factory Establishment ) 4. Representative 5. Types of manufacturing or import business pursuant to Article 8 and Annex 1 of the Enforcement Decree ③ A person who has registered to engage in manufacturing or importing business pursuant to the first part of Article 6, Paragraph 1 of the Act (hereinafter referred to as “manufacturer/importer”) shall, in the event that any of the matters falling under each subparagraph of Paragraph 2 are changed, submit an application for change of registration of manufacturing or importing business in the form of Annex 2 (including electronic documents), attaching the documents (including electronic documents) of each of the following subparagraphs, to the Mayor/Do Governor having jurisdiction over the location of the principal office. In this case, if the matters under subparagraph 2 of Paragraph 2 are changed, the application for change of registration shall be submitted to the Mayor/Do Governor having jurisdiction over the location of the changed principal office. 1. Manufacturing or Import Business Registration Certificate 2. Documents verifying the changes ④ In addition to the matters prescribed in paragraphs 1 through 3, necessary matters concerning the examination of applications for registration or change of registration for manufacturing or importing businesses and the method of assigning registration numbers, etc. shall be determined and announced by the Minister of the Interior and Safety . Article 5 (Issuance of Registration Certificate for Manufacturing or Importing Business, etc.) ① The Mayor or Provincial Governor shall issue a manufacturing or importing business registration certificate in the form of Annex 3 to a manufacturer or importer who has registered pursuant to the first part of Article 6, Paragraph 1 of the Act. The same shall apply to a manufacturer or importer who has registered a change pursuant to Article 4, Paragraph 2 . ② Any manufacturer or importer who wishes to obtain a reissuance of the manufacturing or import business registration certificate pursuant to Paragraph 1 due to loss or damage must submit an application for reissuance of the manufacturing or import business registration certificate in the form of Annex 4 (including electronic documents) to the mayor or provincial governor. Article 6 (Registration Register for Manufacturing or Importing Businesses) When a mayor or provincial governor has issued a manufacturing or importing business registration certificate pursuant to Article 5, Paragraph 1, they shall prepare and manage a registration register using the elevator safety comprehensive information network pursuant to Article 73 of the Act (hereinafter referred to as the “elevator safety comprehensive information network”). Article 7 (Reporting of Closure, Suspension, or Resumption of Manufacturing or Import Business) In accordance with Article 6, Paragraph 4 of the Act , any manufacturer or importer who intends to close or suspend a manufacturing or import business, or to resume a suspended business, shall submit to the Mayor or Provincial Governor the Reporting of Closure, Suspension, or Resumption of Manufacturing or Import Business ( Form No. 5 ) (including electronic documents), attaching the Certificate of Registration of Manufacturing or Import Business (applicable only to the case of reporting closure, and including electronic documents). However, if the Certificate of Registration of Manufacturing or Import Business cannot be attached due to reasons such as loss or damage, the reason may be stated in the Reporting of Closure, Suspension, or Resumption of Manufacturing or Import Business and submitted. <Amended July 29, 2026> Article 8 (Parts for elevator maintenance) In Article 8, Paragraph 1, Subparagraph 1 of the Act , “parts for elevator maintenance prescribed by the Ordinance of the Ministry of the Interior and Safety”refers to parts for elevator maintenance pursuant to Annex 2 . Article 9 (Materials related to maintenance) In Article 8, Paragraph 1, Subparagraph 3, Item B of the Act , the term “materials related to maintenance prescribed by the Ordinance of the Ministry of the Interior and Safety, such as maintenance manuals” refers to the materials in each of the following subparagraphs. 1. Machine drawing 2. Electrical drawings (only applicable if electrical drawings exist) 3. List of Electrical and Electronic Components and Product Guides 4. Installation Manual 5. Maintenance Manual 6. Defect or Fault Diagnosis Guide Article 10 (Detailed Standards for Administrative Dispositions against Manufacturers and Importers, etc.) ① The detailed standards for administrative dispositions against manufacturers and importers pursuant to Article 9, Paragraph 1 of the Act are as set forth in Attached Table 3 . ② In cases where a mayor or provincial governor cancels the registration of a manufacturing or import business or imposes a suspension of all or part of the business pursuant to Article 9, Paragraph 1 of the Act (including cases where a penalty surcharge is imposed in lieu of a business suspension pursuant to Article 10, Paragraph 1 of the Act ), they must announce such fact on the internet homepage without delay. ③ A person who has received a supplementary order pursuant to Article 9, Paragraph 2 of the Act shall supplement the information within the supplementary period and report to the mayor or provincial governor by attaching documents proving the results. Article 10-2 (Deferral of Surcharge Payment Deadline or Payment in Installments) ① A person seeking an extension of the deadline for payment of a surcharge or payment in installments under Article 15 (5) and (6) of the Decree (including where these provisions apply mutatis mutandis under Article 24 (6), Article 32 (4) and Article 35 (3) of the Decree) shall submit an application for deferral in attached Form No. 5-2 or an application for installment payment in attached Form No. 5-3, together with documents proving the reason for the application, to the authority imposing the surcharge no later than ten days before the payment deadline. ② The imposing authority that receives the application under Paragraph 1 shall decide whether to approve the extension of the payment deadline or installment payment of the penalty surcharge by 5 days prior to the payment deadline and notify the applicant. [This Article Newly Inserted Feb. 21, 2022] Chapter 3 Safety Certification of Elevator Parts, etc. Article 11 (Model of Elevator Safety Parts) In Article 11, Paragraph 1 of the Act , “unique name prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to a unique name assigned to each elevator safety part with different designs and functions, etc., in accordance with the model classification criteria in Annex 4 , in order to distinguish elevator safety parts (hereinafter referred to as “elevator safety parts”) pursuant to Article 16 of the Enforcement Decree. Article 12 (Application for Safety Certification of Parts, etc.) ① Where a manufacturer or importer of elevator safety parts seeks safety certification for such parts (hereinafter referred to as “parts safety certification”) under Article 11 (1) of the Act, the manufacturer or importer shall, before shipment or customs clearance, submit an application for parts safety certification for each model in attached Form No. 6 (including an electronic document), together with the documents specified in the following subparagraphs (including electronic documents), to the Minister of the Interior and Safety; where the Korea Elevator Safety Agency under Article 55 of the Act (hereinafter referred to as the “Agency”) or a corporation, institution or organization designated under Article 23 (1) of the Act as an agency for parts safety certification (hereinafter referred to as a “designated certification institution”) has been entrusted under Article 22 (1) of the Act to perform all or part of the certification duties, the application shall be submitted to the Agency or that designated certification institution, respectively. This meaning of Minister shall apply in this Article through Article 14 and Article 16. 1. Copy of Business Registration Certificate 2. Instruction manual for elevator safety parts 3. Documents proving that the elevator safety parts are identical (applicable only if there are two or more factories manufacturing the same elevator safety parts) 4. Technical drawings pursuant to Article 17 , subparagraph 1 of the Enforcement Decree 5. Certificate of exemption pursuant to the first part of Article 17, Paragraph 2 (only applicable if a certificate of exemption has been obtained) 6. Sample of the part safety certification mark pursuant to Item 1 of Annex 5 ② Manufacturers and importers of elevator safety parts who intend to apply for part safety certification pursuant to Paragraph 1 shall submit the following samples required for safety testing pursuant to Article 17 , Subparagraph 2 of the Enforcement Decree . 1. Relevant elevator safety parts 2. Among the elevator components constituting the relevant elevator safety component, elevator components that are electrical products under Article 2 , Paragraph 1 of the Electrical Appliances and Household Goods Safety Management Act and fall under any of the following subparagraphs a. Electrical products that have not received safety certification pursuant to Article 5 of the Electrical Appliances and Household Goods Safety Management Act B. Electrical appliances for which a safety confirmation report has not been filed pursuant to Article 15 of the Electrical Appliances and Household Goods Safety Management Act C. Electrical appliances for which a Supplier Conformity Report has not been filed pursuant to Article 23 of the Electrical Appliances and Household Goods Safety Management Act 3. Among the elevator parts constituting the relevant elevator safety parts, excluding those under Subparagraph 2, elevator parts for which the Minister of the Interior and Safety recognizes that safety testing is necessary for the purpose of part safety certification and notifies thereof. ③ The Minister of the Interior and Safety shall complete the examination and testing prescribed in each subparagraph of Article 17 of the Enforcement Decree and notify the applicant of the results of the parts safety certification within 45 days from the date of receipt of the application under Paragraph 1. However, in cases falling under any of the following subparagraphs, the processing period may be extended by the corresponding period. <Amended Feb. 21, 2022> 1. The period exceeding 30 days in cases where, due to the characteristics of the relevant elevator safety component, the period required for the design review pursuant to Article 17 , Subparagraph 1 of the Enforcement Decree or the period required for the safety test pursuant to Article 17 , Subparagraph 2 of the Enforcement Decree exceeds 30 days. 2. The period during which the reason is recognized when the applicant requests an extension of the processing period due to unavoidable circumstances such as a disaster. ④ When the Minister of the Interior and Safety anticipates that he/she will be unable to notify the results of the parts safety certification within the processing period under Paragraph 3 due to unavoidable reasons, such as a rapid increase in applications for parts safety certification, he/she shall notify the applicant of the reason and the expected processing period. ⑤ If the results of the examination and test under each subparagraph of Article 17 of the Enforcement Decree meet the standards of each of the following subparagraphs, the Minister of the Interior and Safety shall issue a parts safety certification in the form of Annex 7 to the applicant. 1. Standards regarding the safety of elevator safety components themselves pursuant to Article 11, Paragraph 3, Subparagraph 1 of the Act (hereinafter referred to as “Elevator Safety Component Safety Standards”) 2. Standards regarding facilities and technical capabilities, etc. required for the manufacture of elevator safety parts pursuant to Article 11, Paragraph 3, Subparagraph 2 of the Act (hereinafter referred to as the “Parts Factory Inspection Standards”) Article 13 (Issuance Register of Component Safety Certificates, etc.) ① When the Minister of the Interior and Safety issues a component safety certificate pursuant to Article 12, Paragraph 5, he/she shall create and manage an issuance register using the Elevator Safety Comprehensive Information Network. ② If a person who has received a parts safety certification pursuant to Article 12, Paragraph 5 requests confirmation of the fact that they have received the parts safety certification , the Minister of the Interior and Safety shall issue a document confirming such fact. Article 14 (Application for Change of Component Safety Certification, etc.) ① If a manufacturer or importer of elevator safety componentsintends to change the matters for which component safety certification has been obtained pursuant to the main clause of Article 11, Paragraph 2 of the Act , they must submit to the Minister of the Interior and Safety, prior to shipment or customs clearance of the relevant elevator safety components, an application for change of component safety certification (including electronic documents) in Form No. 8 of the Appendix, with documents proving the fact of change (including electronic documents) attached. ② When the Minister of the Interior and Safety receives an application for change pursuant to Paragraph 1, he/she shall verify whether the contents of the application for change comply with the safety standards for elevator safety parts and the parts factory inspection standards, and issue a new parts safety certification in the form of Annex 7 to the applicant. ③ When the Minister of the Interior and Safety issues a parts safety certification pursuant to Paragraph 2, he/she shall prepare and manage an issuance register using the Elevator Safety Comprehensive Information Network. ④ If a person who has received a parts safety certification pursuant to paragraph 2 requests confirmation of the fact that they have received the parts safety certification, the Minister of the Interior and Safety shall issue a document confirming such fact. ⑤ In the proviso to Article 11, Paragraph 2 of the Act , “cases where minor matters prescribed by the Ordinance of the Ministry of the Interior and Safety are changed” refers to any of the cases falling under any of the following subparagraphs. <Amended Feb. 21, 2022> 1. In the case of changing the circuit of the secondary side of the transformer used in elevator safety components (limited to AC power of 30 volts or less or DC power of 42 volts or less; hereinafter the same applies) (excluding safety circuits in accordance with the safety standards for elevator safety components), elevator components, insulation materials, or changing materials for combustion prevention 2. In the case of changing the color of elevator safety components 3. Cases where only the control circuit is changed without modifying the safety circuit in accordance with the safety standards for elevator safety components 4. Cases where design and manufacturing drawings are modified without changing the specifications or materials related to the design and manufacturing of elevator safety components, and the history of such changes is managed internally. 5. When changing electrical installations and electrical equipment to those standardized in accordance with Korean Industrial Standards (KS) or those having performance of an equivalent or higher level Article 15 (Application of New Safety Standards for Elevator Safety Components) ① Any person falling under any of the following subparagraphs may apply to the Minister of the Interior and Safety for the enactment or amendment of new safety standards for elevator safety components applicable to said elevator safety components in cases where safety standards for elevator safety components have not been notified or where notified safety standards for elevator safety components cannot be applied, in accordance with the proviso to the part other than the subparagraphs of Article 11, Paragraph 3 of the Act. 1. Manufacturers and importers of elevator safety components seeking component safety certification 2. The Korea Elevator Safety Agency or a designated certification institution performing parts safety certification duties on behalf of the Minister ② The Minister of the Interior and Safety shall notify the applicant of whether the enactment or revision of new elevator safety component safety standards applicable to the relevant elevator safety component is being pursued within 15 days from the date of receiving the application under Paragraph 1, and may notify the Corporation and designated certification bodies of any of the standards falling under any of the following subparagraphs to have them perform the work of component safety certification on their behalf. 1. Industrial standards pursuant to Article 12 of the Industrial Standardization Act 2. International standards pursuant to Article 3, Subparagraph 2 of the Framework Act on National Standards 3. Standards deliberated and resolved by the Elevator Safety Committee (hereinafter referred to as the “Committee”) pursuant to Article 5 of the Enforcement Decree Article 16 (Conditions for Safety Certification of Parts) Pursuant to Article 11, Paragraph 4 of the Act , the Minister of the Interior and Safety may attach any of the following conditions. 1. Implementation of self-assessment pursuant to Article 13 , Paragraph 2 of the Act 2. Supplement elevator safety components to meet elevator safety component safety standards 3. Improve factory facilities to meet parts factory inspection standards 4. Report on the fulfillment of conditions pursuant to the provisions of Subparagraphs 1 through 3 Article 17 (Application for Exemption from Parts Safety Certification, etc.) ① Any person who wishes to be exempted in whole or in part from parts safety certification pursuant to Article 12 of the Act shall, in accordance with Article 18, Paragraph 4 of the Enforcement Decree, submit to the Corporation, prior to shipment or customs clearance of the relevant elevator safety parts, an application for exemption from parts safety certification (including electronic documents) in the form of Annex No. 9 , attaching the documents listed in each of the following subparagraphs (including electronic documents). 1. Copy of Business Registration Certificate 2. Documents proving a fact falling under any of the subparagraphs of Article 12 of the Act (excluding subparagraph 2 of the same article ) ② Upon receiving an application for exemption pursuant to Paragraph 1, the Corporation shall issue a Confirmation of Exemption from Part Safety Certification in the form of Annex 10 to the applicant if the relevant elevator safety part falls under any of the subparagraphs of Article 12 of the Act ( excluding subparagraph 2 of the same article ) . In this case, the Corporation shall issue a mark of exemption from part safety certification pursuant to subparagraph 2 of Annex 5 to the applicant who has been exempted from the entire part safety certification. Article 18 (Verification of Elevator Safety Parts for Research and Development, etc.) ① Any person who intends to obtain verification for elevator safety parts manufactured or imported for the purpose of research and development, exhibition, or testing for parts safety certification pursuant to Article 12, subparagraph 1 of the Act shall submit to the Corporation documents or explanatory statements proving whether the relevant elevator safety parts correspond to elevator safety parts pursuant to Article 18, paragraph 2 and Annex 5 of the Enforcement Decree. ② When the Corporation receives documents or descriptions pursuant to Paragraph 1, it shall verify whether the relevant elevator safety parts correspond to elevator safety parts pursuant to Article 18, Paragraph 2 and Annex 5 of the Enforcement Decree. Article 19 (Verification of Self-Safety Testing of Elevator Safety Components) ① The term “ manufacturer or importer of elevator safety components possessing testing capabilities of a certain level or higher as prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 12, subparagraph 5 of the Act refers to a manufacturer or importer falling under any of the following subparagraphs. 1. Manufacturers and importers of elevator safety components that are testing and inspection agencies accredited by an accreditation body pursuant to Article 23, Paragraph 2 of the Framework Act on National Standards 2. Manufacturers and importers of elevator safety components who have been recognized as testing laboratories by an accredited institution in accordance with the International Organization for Standardization (ISO) certification system for elevator safety components. ② A manufacturer or importer of elevator safety parts pursuant to Paragraph 1 who intends to obtain confirmation from the Corporation pursuant to Article 12 , Item 5 of the Act shall conduct a safety test on the relevant elevator safety parts independently pursuant to Article 17, Item 2 of the Enforcement Decree and submit the results to the Corporation. ③ The Corporation shall verify whether the safety test under Paragraph 2 has been conducted in accordance with the safety standards for elevator safety components. Article 20 (Exemption from Safety Certification for Elevator Safety Parts Imported or Manufactured on a One-time basis) Cases in which elevator safety parts are imported or manufactured on a one-time basis pursuant to Article 12, subparagraph 6 of the Act shall be cases where a manufacturer or importer of elevator safety parts imports or manufactures 20 or fewer elevator safety parts and clears customs or releases them at once. Article 21 (Recognition of Safety of Elevator Safety Components, etc.) In subparagraph 7 of Article 12 of the Act , “cases prescribed by the Ordinance of the Ministry of the Interior and Safety, such as cases where the safety of elevator safety components is recognized pursuant to other laws and regulations” refers to any of the following cases: 1. In cases where the product has been certified pursuant to Article 15 of the Industrial Standardization Act 2. Cases where safety certification has been obtained pursuant to Article 5 of the Electrical Appliances and Household Goods Safety Management Act, or where a safety confirmation report has been filed pursuant to Article 15 of the same Act or a supplier conformity confirmation report has been filed pursuant to Article 23 of the same Act 3. In cases where the elevator safety components of the model to be imported are identical to the elevator safety components of a model that has received component safety certification. 4. In cases where elevator safety parts are imported for the maintenance of imported elevator safety parts, within 2.5 percent of the total imported quantity of elevator safety parts. Article 22 (Application for Periodic Review of Elevator Safety Parts, etc.) ① A manufacturer or importer of elevator safety parts seeking periodic review of such parts under Article 13 (1) of the Act (hereinafter referred to as “periodic review of parts”) shall submit an application for periodic review of parts in attached Form No. 11 (including an electronic application) to the Korea Elevator Safety Agency or a designated certification institution no later than 45 days before the date when the review cycle under Article 19 (1) of the Decree is due. ② The Corporation or the designated certification body shall notify the applicant of an examination plan containing the following items within 7 days from the date of receipt of the application pursuant to Paragraph 1. 1. Subject of Review 2. Review Period 3. Reviewer 4. Other matters necessary for the examination ③ When the Corporation or the designated certification body completes the periodic inspection of parts, it shall prepare a document containing the results and notify the applicant. ④ An applicant who has an objection to the result pursuant to Paragraph 3 may request a re-examination from the Corporation or a designated certification body within 15 days from the date of receiving the result pursuant to Article 19, Paragraph 3 of the Enforcement Decree . ⑤ Any Corporation or designated certification body that receives a request for re-examination pursuant to Paragraph 4 shall conduct a re-examination and notify the applicant of the results. ⑥ If the Corporation or the designated certification body confirms that any of the following cases apply as a result of the regular parts inspection under Paragraph 3 or the re-inspection under Paragraph 5, it shall notify the Minister of the Interior and Safety and the Mayor/Do Governor of the confirmed details without delay. 1. In cases where elevator safety components do not meet the safety standards for elevator safety components 2. Cases where the manufacturing system, including facilities and technical capabilities for manufacturing elevator safety components, does not meet the component factory inspection criteria ⑦ If there is a person falling under any of the following subparagraphs, the Corporation or the designated certification body shall notify the Minister of the Interior and Safety and the Mayor/Do Governor of such fact without delay. 1. Persons who have not undergone periodic parts inspection 2. Persons who have not conducted an internal review pursuant to Article 13, Paragraph 2 of the Act 3. Persons who fail to prepare and keep records of self-assessment pursuant to Article 13, Paragraph 2 of the Act, or who prepare and keep false records. Article 23 (Self-assessment of safety of elevator safety parts) ① Manufacturers and importers of elevator safety parts shall conduct a self-assessment of the safety of elevator safety parts of the same model manufactured or imported after obtaining safety certification for parts pursuant to Article 13, Paragraph 2 of the Act , in accordance with the standards notified by the Minister of the Interior and Safety, taking into consideration the matters in each of the following subparagraphs. 1. Evaluation Criteria 2. Review Cycle by Review Item 3. Evaluation Method ② When a manufacturer or importer of elevator safety parts has completed the self-assessment pursuant to Paragraph 1, they shall record the matters in each of the following subparagraphs and keep the records for 5 years. 1. Elevator Safety Component Name and Model Name 2. Date and location of internal review 3. Name of the person who conducted the self-assessment 4. Quantity of internal review 5. Results of internal review [Title amended Feb. 21, 2022] Article 24 (Marking of Parts Safety Certification) ① The markings according to the classifications in each subparagraph of Article 14, Paragraph 1 of the Act (hereinafter referred to as “parts safety certification markings, etc.”) are as set forth in Annex 5 . ② The timing for displaying the parts safety certification mark, etc., is as follows: 1. Elevator safety components manufactured domestically: Before shipment 2. Elevator safety parts manufactured abroad and imported into the country: Before customs clearance ③ In cases where a person falling under any of the subparagraphs of Article 14, Paragraph 3 of the Act sells, rents, brokers sales of elevator safety parts (excluding cases where a telecommunications sales intermediary under the Act on the Consumer Protection in Electronic Commerce, etc. , immediately deletes elevator safety parts without safety certification marks found in the cyber mall they operate, requires the client requesting telecommunications sales intermediary to input information on safety certification marks when registering products, and takes technical measures to enable consumers to verify such information), or acts as a purchasing agent or import agent for elevator safety parts through the Internet, they must post the following information regarding safety certification of parts on their website in accordance with Article 14 , Paragraph 4 of the Act . 1. Part Safety Certification Indicator 2. Part Safety Certification Number 3. Name of elevator safety component and model name 4. Trade name of manufacturer/importer Article 25 (Cancellation of Parts Safety Certification, etc.) ① The detailed standards for administrative dispositions regarding the cancellation of parts safety certification, orders prohibiting the use of parts safety certification marks, etc., or orders for improvement pursuant to Article 16, Paragraph 1 of the Act are as set forth in Attached Table 6 . ② When a City or Provincial Governor issues a cancellation of parts safety certification, an order prohibiting the use of parts safety certification marks, or an order for improvement pursuant to Paragraph 1, they shall announce the following matters on the internet homepage in accordance with Article 16, Paragraph 2 of the Act . 1. Name of the manufacturer or importer (in the case of a corporation, this refers to the name of the corporation and the name of the representative. The same applies hereinafter) 2. Name of elevator safety component and model name 3. Contents of the cancellation of parts safety certification, the order prohibiting the use of parts safety certification marks, etc., or the improvement order (including the period of prohibition in the case of an order prohibiting the use of parts safety certification marks, etc.), the date of the disposition, and the reasons Article 26 (Model of an elevator) The model of an elevator pursuant to the main text of Article 17, Paragraph 1 of the Act refers to a unique name assigned to each elevator with different designs and functions, etc., in accordance with the model classification criteria in Annex 4 to distinguish elevators. Article 27 (Application for Model Elevator Safety Certification, etc.) ① A manufacturer or importer seeking safety certification for an elevator model under the main text of Article 17 (1) of the Act (hereinafter referred to as “model elevator safety certification”) shall submit, before shipment or customs clearance of the elevator, an application for model elevator safety certification for each model in attached Form No. 12 (including electronic documents), together with the documents specified in the following subparagraphs (including electronic documents), to the Minister of the Interior and Safety (or to the Korea Elevator Safety Agency where the Agency performs these duties on behalf of the Minister under Article 22 (1) of the Act; hereinafter the same applies in this Article through Article 30 and Article 32). 1. Copy of Business Registration Certificate 2. Instruction Manual for the Elevator 3. List of Elevator Safety Components 4. Documents proving that it is the same elevator (applicable only if there are two or more factories manufacturing the same elevator) 5. Technical documents pursuant to Article 20 , Subparagraph 1 of the Enforcement Decree 6. Certificate of Exemption from Elevator Safety Certification pursuant to the first part of Article 33, Paragraph 2 (only applicable if a Certificate of Exemption from Elevator Safety Certification has been obtained) 7. Sample of the mark for elevator safety certification pursuant to Item 1 of Annex 5 ② An elevator manufacturer or importer who intends to apply for model elevator safety certification pursuant to Paragraph 1 shall install the elevator required for safety testing pursuant to Article 20 , Subparagraph 2 of the Enforcement Decree in the Corporation’s testing facilities, etc., and submit samples of each of the following subparagraphs. 1. Among the elevator components constituting the elevator in question, any elevator component falling under any of the following subparagraphs as an electrical product pursuant to Article 2 , Subparagraph 1 of the Electrical Appliances and Household Goods Safety Management Act a. Electrical products that have not received safety certification pursuant to Article 5 of the Electrical Appliances and Household Goods Safety Management Act B. Electrical appliances for which a safety confirmation report has not been filed pursuant to Article 15 of the Electrical Appliances and Household Goods Safety Management Act C. Electrical appliances for which a Supplier Conformity Report has not been filed pursuant to Article 23 of the Electrical Appliances and Household Goods Safety Management Act 2. Elevator parts constituting an elevator, excluding those under Subparagraph 1, which the Minister of the Interior and Safety deems necessary to test for model elevator safety certification and notifies thereof. ③ The Minister of the Interior and Safety shall complete the examinations and tests prescribed in each subparagraph of Article 20 of the Enforcement Decree and notify the applicant of the results of the elevator safety certification within 90 days from the date of receipt of the application under Paragraph 1. However, in cases falling under any of the following subparagraphs, the processing period may be extended by the corresponding period. <Amended Feb. 21, 2022> 1. The period exceeding 60 days in cases where, due to the characteristics of the elevator concerned, the period required for the design review pursuant to Article 20, Subparagraph 1 of the Enforcement Decree or the period required for the safety test pursuant to Article 20, Subparagraph 2 of the Enforcement Decree exceeds 60 days 2. The period during which the reason is recognized when the applicant requests an extension of the processing period due to unavoidable circumstances such as a disaster. ④ When the Minister of the Interior and Safety anticipates that he/she will be unable to notify the results of the model elevator safety certification within the processing period under Paragraph 3 due to unavoidable reasons, such as a rapid increase in applications for model elevator safety certification, he/she shall notify the applicant of the reason and the expected processing period. ⑤ If the results of the examination and testing under each subparagraph of Article 20 of the Enforcement Decree meet the standards of each of the following subparagraphs, the Minister of the Interior and Safety shall issue an elevator safety certification in the form of Annex 14 to the applicant. 1. Standards for the safety of the elevator itself pursuant to Article 17, Paragraph 3, Subparagraph 1 of the Act (hereinafter referred to as “Elevator Safety Standards”) 2. Standards regarding facilities and technical capabilities, etc. required for the manufacture of elevators pursuant to Article 17, Paragraph 3, Subparagraph 2 of the Act (hereinafter referred to as the “Elevator Factory Inspection Standards”) Article 28 (Standards and Application for Individual Elevator Safety Certification, etc.) ① In the event that an elevator manufacturer or importer intends to obtain safety certification for an elevator for which no model has been determined pursuant to the proviso to Article 17, Paragraph 1 of the Act (hereinafter referred to as “individual elevator safety certification”), they must submit to the Minister of the Interior and Safety, prior to shipment or customs clearance of the relevant elevator, an application for individual elevator safety certification in the form of Annex 13 (including electronic documents), with the documents specified in each subparagraph of Article 27 , Paragraph 1 (excluding subparagraph 6 of the same paragraph, which includes electronic documents) attached. ② The Minister of the Interior and Safety shall complete the design review pursuant to Article 20, Subparagraph 1 of the Enforcement Decree and notify the applicant of the results of the individual elevator safety certification within 20 days from the date of receipt of the application under Paragraph 1. However, if the applicant requests an extension of the processing period due to unavoidable reasons such as a disaster, the processing period may be extended by the period for which such reason is recognized. <Amended Feb. 21, 2022> ③ If the Minister of the Interior and Safety anticipates that the results of the individual elevator safety certification will not be provided within the processing period under Paragraph 2 due to unavoidable circumstances, such as a rapid increase in applications for individual elevator safety certification, the Minister shall notify the applicant of the reason and the anticipated processing period. ④ If the results of the design review pursuant to Article 20 , subparagraph 1 of the Enforcement Decree are in accordance with the elevator safety standards, the Minister of the Interior and Safety shall issue an elevator safety certification in the form of Annex 14 to the applicant. Article 29 (Issuance Register of Elevator Safety Certificates, etc.) ① When the Minister of the Interior and Safety issues an elevator safety certificate pursuant to Article 27 , Paragraph 5 and Article 28 , Paragraph 4 , he/she shall create and manage an issuance register using the Elevator Safety Comprehensive Information Network. ② If a person who has received an elevator safety certification pursuant to Article 27 , Paragraph 5 and Article 28 , Paragraph 4 requests confirmation of the fact that they have received the elevator safety certification , the Minister of the Interior and Safety shall issue a document confirming such fact. Article 30 (Application for Change of Elevator Safety Certification, etc.) ① If an elevator manufacturer or importer intends to change the matters for which a model elevator safety certification or individual elevator safety certification (hereinafter referred to as “elevator safety certification”) has been obtained pursuant to the main clause of Article 17, Paragraph 2 of the Act, they must submit to the Minister of the Interior and Safety, prior to the shipment or customs clearance of the relevant elevator, an application for change of elevator safety certification (including electronic documents) in the form of Annex 15 , along with documents proving the fact of change (including electronic documents). ② When the Minister of the Interior and Safety receives an application for change pursuant to Paragraph 1, he/she shall verify whether the contents of the application for change meet the standards according to the classifications in each of the following subparagraphs and issue a new elevator safety certification in the form of Annex 14 to the applicant. 1. Elevators with Model Safety Certification: Elevator Safety Standards and Elevator Factory Inspection Standards 2. Elevators with Individual Safety Certification: Elevator Safety Standards ③ When the Minister of the Interior and Safety issues an elevator safety certification pursuant to Paragraph 2, he/she shall prepare and manage an issuance register using the Elevator Safety Comprehensive Information Network. ④ If a person who has received an elevator safety certification pursuant to paragraph 2 requests confirmation of the fact that they have received the elevator safety certification, the Minister of the Interior and Safety shall issue a document confirming such fact. ⑤ In the proviso to Article 17, Paragraph 2 of the Act , “cases where minor matters prescribed by the Ordinance of the Ministry of the Interior and Safety are changed” refers to any of the cases falling under any of the following subparagraphs. <Amended Feb. 21, 2022> 1. In the case of changing the circuit of the secondary side of the transformer used in the elevator (limited to AC power of 30 volts or less or DC power of 42 volts or less; hereinafter the same applies) (excluding safety circuits in accordance with elevator safety standards), elevator components, insulation materials, or changing materials for combustion prevention 2. In the case of changing the elevator color 3. When changing circuits other than the power circuit, brake circuit, and safety circuit in accordance with elevator safety standards 4. Cases where design and manufacturing drawings are modified without changing specifications or materials related to the design and manufacturing of the elevator, and the history of such changes is managed internally. 5. When changing electrical installations and electrical equipment to those standardized in accordance with Korean Industrial Standards (KS) or those having performance of an equivalent or higher level Article 31 (Application of New Elevator Safety Standards) ① Any person falling under any of the following subparagraphs may apply to the Minister of the Interior and Safety for the enactment or amendment of new elevator safety standards applicable to an elevator in cases where elevator safety standards have not been notified or where notified elevator safety standards cannot be applied, in accordance with the proviso to the part other than the subparagraphs of Article 17, Paragraph 3 of the Act. 1. Elevator manufacturers and importers seeking elevator safety certification 2. The Korea Elevator Safety Agency performing elevator safety certification duties on behalf of the Minister ② The Minister of the Interior and Safety shall notify the applicant of whether the enactment or revision of new elevator safety standards applicable to the elevator is being pursued within 15 days from the date of receiving the application under Paragraph 1, and may notify the Corporation of any of the standards falling under any of the following subparagraphs and have the Corporation perform the elevator safety certification work on their behalf. 1. Industrial standards pursuant to Article 12 of the Industrial Standardization Act 2. International standards pursuant to Article 3, Subparagraph 2 of the Framework Act on National Standards 3. Standards deliberated and resolved by the Committee Article 32 (Conditions for Model Elevator Safety Certification) Pursuant to Article 17, Paragraph 4 of the Act , the Minister of the Interior and Safety may attach any of the following conditions. 1. Implementation of self-assessment pursuant to Article 19 , Paragraph 2 of the Act 2. Improve the elevator to meet elevator safety standards 3. Improve factory facilities to meet elevator factory inspection standards 4. Report on the fulfillment of conditions pursuant to the provisions of Subparagraphs 1 through 3 Article 33 (Application for Exemption from Elevator Safety Certification, etc.) ① Any person who wishes to be exempted in whole or in part from elevator safety certification pursuant to Article 18 of the Act shall, in accordance with Article 21, Paragraph 4 of the Enforcement Decree, submit to the Corporation , prior to the shipment or customs clearance of the relevant elevator, an application for exemption from elevator safety certification in the form of Annex 16 (including electronic documents), attaching the documents listed in each of the following subparagraphs (including electronic documents). 1. Copy of Business Registration Certificate 2. Documents proving a fact falling under any of the subparagraphs of Article 18 of the Act (excluding subparagraph 2 of the same article ) ② Upon receiving an application for exemption pursuant to Paragraph 1, the Corporation shall issue a Confirmation of Exemption from Elevator Safety Certification in the form of Annex 17 to the applicant if the relevant elevator falls under any of the subparagraphs of Article 18 of the Act (excluding subparagraph 2 of the same article ). In this case, the Corporation shall issue an indication of exemption from elevator safety certification pursuant to subparagraph 2 of Annex 5 to an applicant who has been exempted from the entire elevator safety certification. Article 34 (Verification of elevators for research and development, etc.) ① Any person who intends to obtain verification from the Corporation for an elevator manufactured or imported for the purpose of research and development, exhibition, or testing for elevator safety certification pursuant to Article 18, subparagraph 1 of the Act shall submit to the Corporation documents or an explanatory statement proving whether the said elevator falls under the category of elevators specified in Article 21, paragraph 2 and Annex 5 of the Enforcement Decree. ② When the Corporation receives documents or explanatory statements pursuant to Paragraph 1, it must verify whether the relevant elevator falls under the elevators specified in Article 21, Paragraph 2 and Annex 5 of the Enforcement Decree . Article 35 (Verification of Self-Safety Tests of Elevators) ① The term “manufacturer or importer of an elevator possessing testing capabilities of a certain level or higher as prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 18, subparagraph 5 of the Act refers to a manufacturer or importer falling under any of the following subparagraphs. 1. Manufacturers and importers of elevators that are testing and inspection agencies accredited by an accreditation body pursuant to Article 23, Paragraph 2 of the Framework Act on National Standards 2. Manufacturers and importers of elevators who have been recognized as testing laboratories by an accredited institution in accordance with the International Organization for Standardization's certification system for elevators. ② Any person who is a manufacturer or importer of an elevator pursuant to Paragraph 1 and intends to obtain confirmation from the Corporation pursuant to Article 18 , Item 5 of the Act shall conduct a safety test on the relevant elevator independently pursuant to Article 20 , Item 2 of the Enforcement Decree and submit the results to the Corporation. ③ The Corporation shall verify whether the safety test under Paragraph 2 has been conducted in accordance with elevator safety standards. Article 36 (Exemption from Elevator Safety Certification for One-time Imported or Manufactured Elevators) Cases where elevators are imported or manufactured on a one-time basis pursuant to Article 18 , subparagraph 6 of the Act shall be cases where an elevator manufacturer or importer imports or manufactures 20 or fewer elevators and clears customs or ships them all at once. Article 36-2 (Exemption from Elevator Safety Certification for Jointly Designed Elevators) In Article 18, subparagraph 6-2 of the Act , “corporations or organizations composed of elevator manufacturers or importers as prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to any corporation or organization falling under any of the following subparagraphs. 1. The Elevator Business Association pursuant to Article 15 of the Elevator Industry Promotion Act (hereinafter referred to as the “Association”) 2. A small and medium-sized enterprise cooperative established pursuant to Article 3 of the Small and Medium Enterprise Cooperatives Act, with elevator manufacturers and importers as members. [This Article Newly Inserted July 26, 2024] Article 37 (Recognition of Elevator Safety, etc.) In subparagraph 7 of Article 18 of the Act , “cases prescribed by the Ordinance of the Ministry of the Interior and Safety, such as cases where the safety of an elevator is recognized in accordance with other laws and regulations” refers to any of the following cases: 1. In cases where the product has been certified pursuant to Article 15 of the Industrial Standardization Act 2. Cases where safety certification has been obtained pursuant to Article 5 of the Electrical Appliances and Household Goods Safety Management Act, or where a safety confirmation report has been filed pursuant to Article 15 of the same Act or a supplier conformity confirmation report has been filed pursuant to Article 23 of the same Act 3. Cases where a conformity assessment has been received pursuant to Article 58-2 of the Radio Waves Act 4. If the elevator of the model to be imported is identical to the elevator of the model that has received model elevator safety certification Article 38 (Application for Periodic Inspection of Elevators, etc.) ① If an elevator manufacturer or importer intends to undergo a periodic inspection of an elevator pursuant to Article 19, Paragraph 1 of the Act (hereinafter referred to as “periodic elevator inspection”), they must submit an application for periodic elevator inspection in the form of Annex 18 (including electronic documents) to the Corporation at least 90 days prior to the due date of the inspection cycle for the periodic elevator inspection pursuant to Article 22, Paragraph 1 of the Enforcement Decree. ② The Corporation shall notify the applicant of an examination plan containing the following items within 7 days from the date of receipt of the application pursuant to Paragraph 1. 1. Subject of Review 2. Review Period 3. Reviewer 4. Other matters necessary for the examination ③ When the Corporation has completed the periodic inspection of elevators, it shall prepare a written document of the results and notify the applicant. ④ An applicant who has an objection to the result pursuant to Paragraph 3 may request a re-examination from the Corporation within 15 days from the date of receiving the result pursuant to Article 22, Paragraph 3 of the Enforcement Decree . ⑤ The Corporation that receives a request for re-examination pursuant to Paragraph 4 shall conduct a re-examination and notify the applicant of the results. ⑥ If the Corporation confirms that any of the following cases apply as a result of the regular elevator inspection under Paragraph 3 or the re-inspection under Paragraph 5, it shall notify the Minister of the Interior and Safety and the Mayor/Do Governor of the confirmed details without delay. 1. If the elevator does not meet elevator safety standards 2. Cases where the manufacturing system, including facilities and technical capabilities for manufacturing elevators, does not meet the elevator factory inspection standards ⑦ If there is a person falling under any of the following subparagraphs, the Corporation shall notify the Minister of the Interior and Safety and the Mayor/Do Governor of such fact without delay. 1. Persons who have not undergone the regular elevator inspection 2. Persons who have not conducted a self-assessment pursuant to Article 19, Paragraph 2 of the Act 3. Persons who fail to prepare and keep records of self-assessment pursuant to Article 19, Paragraph 2 of the Act, or who prepare and keep false records. Article 39 (Self-assessment of elevator safety) ① The self-assessment of elevator safety pursuant to Article 19, Paragraph 2 of the Act shall be in accordance with the standards for self-assessment notified by the Minister of the Interior and Safety, taking into consideration the matters of each of the following subparagraphs . 1. Evaluation Criteria 2. Review Cycle by Review Item 3. Evaluation Method ② When an elevator manufacturer or importer has completed the self-inspection pursuant to Paragraph 1, they shall record the matters in each of the following subparagraphs and keep the records for five years. 1. Elevator Name and Model Name 2. Date and location of internal review 3. Name of the person who conducted the self-assessment 4. Quantity of internal review 5. Results of internal review Article 40 (Marking of Elevator Safety Certification, etc.) ① The markings according to the classifications in each subparagraph of Article 20, Paragraph 1 of the Act (hereinafter referred to as “elevator safety certification markings, etc.”) are as set forth in Table 5 . ② Elevator safety certification marks, etc. shall be affixed at the following times: 1. Elevators manufactured domestically: Before shipment 2. Elevators manufactured abroad and imported into the country: Before customs clearance ③ In cases where a person falling under any of the subparagraphs of Article 20, Paragraph 3 of the Act sells, rents, brokers sales of elevators (excluding cases where a telecommunications sales intermediary under the Act on the Consumer Protection in Electronic Commerce, etc., immediately deletes elevators without elevator safety certification marks found in the cyber mall they operate, requires the client requesting telecommunications sales intermediary to input information on elevator safety certification marks when registering products, and takes technical measures to enable consumers to verify such information), or acts as a purchasing agent or import agent for elevators through the Internet, they must post the following elevator safety certification-related information on their website in accordance with Article 20, Paragraph 4 of the Act . 1. Elevator safety certification marks, etc. 2. Elevator Safety Certification Number 3. Elevator name and model name (excluding elevators that have received individual safety certification) 4. Trade name of manufacturer/importer Article 41 (Cancellation of Elevator Safety Certification, etc.) ① The detailed standards for administrative dispositions regarding the cancellation of elevator safety certification, the order to prohibit the use of elevator safety certification marks, etc., or the order for improvement pursuant to Article 21, Paragraph 1 of the Act are as set forth in Table 7 . ② When a mayor or provincial governor issues a cancellation of elevator safety certification, an order to prohibit the use of elevator safety certification marks, or an order for improvement pursuant to Paragraph 1, they shall announce the matters of each of the following subparagraphs on the internet homepage in accordance with Article 21, Paragraph 2 of the Act . 1. Name of manufacturer/importer 2. Elevator name and model name (excluding elevators that have received individual safety certification) 3. Contents of the cancellation of elevator safety certification, the order prohibiting the use of elevator safety certification indicators, or the improvement order (including the period of prohibition in the case of an order prohibiting the use of elevator safety certification indicators), the date of the disposition, and the reasons Article 42 (Utilization of Test Results from Domestic and Foreign Testing Institutions, etc.) ① In cases where the Corporation or a designated certification body intends to have domestic or foreign testing institutions conduct tests to verify compliance with the standards specified in each subparagraph of the same paragraph pursuant to Article 22, Paragraph 2 of the Act and utilize the results for parts safety certification or model elevator safety certification, it must obtain confirmation from the Minister of the Interior and Safety in advance. ② Domestic or foreign testing institutions capable of conducting tests pursuant to Paragraph 1 and utilizing the results for parts safety certification or model elevator safety certification shall be institutions falling under any of the following subparagraphs and having entered into a contract with the Corporation or a designated certification body acknowledging the results of the tests pursuant to Paragraph 1. 1. Testing and inspection institutions accredited by an accreditation body pursuant to Article 23, Paragraph 2 of the Framework Act on National Standards 2. Testing and inspection institutions accredited under the International Laboratory Accreditation Cooperation (ILAC) in accordance with international standards of the International Organization for Standardization 3. Certification bodies accredited under the International Electrotechnical Commission (IECEE) Article 43 (Application for Designation of Designated Certification Agency, etc.) ① Any corporation, organization, or institution seeking designation as a designated certification agency pursuant to Article 23, Paragraph 1 of the Act shall submit to the Minister of the Interior and Safety an application for designation as a designated certification agency (including electronic documents) in the form of Annex No. 19 , attaching the documents (including electronic documents) of each of the following subparagraphs. 1. Articles of incorporation of a corporation or bylaws of an organization 2. A business plan including the organization, personnel, and testing facilities, etc., for performing parts safety certification tasks 3. Business regulations regarding procedures and methods, etc. for performing parts safety certification work 4. Documents proving that the designation criteria for a designated certification body pursuant to Article 23 of the Enforcement Decree have been met ② When the Minister of the Interior and Safety receives an application for designation under Paragraph 1, he/she shall verify the Certificate of Corporate Registration (applicable only to corporations) through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act. However, if the applicant does not consent, the applicant shall be required to attach the Certificate of Corporate Registration. ③ When the Minister of the Interior and Safety receives an application for designation pursuant to Paragraph 1, he/she shall notify the applicant of an examination plan including on-site inspection, etc., and conduct an examination in accordance with the examination plan. ④ If the Minister of the Interior and Safety recognizes that a person who has submitted an application for designation under Paragraph 1 meets the designation criteria for a designated certification body under Article 23 of the Enforcement Decree after reviewing the case under Paragraph 3 and deliberating on the matter with the Committee, the Minister may designate that person as a designated certification body by determining the scope of work for parts safety certification. ⑤ When the Minister of the Interior and Safety designates a certification body pursuant to Paragraph 4, he/she shall issue a Certificate of Designation of Certification Body in the form of Annex 20 and announce the matters of each of the following subparagraphs in the Official Gazette and on the internet homepage. 1. Designation Date and Designation Number 2. Name of the Designated Certification Body 3. Address of the designated certification authority 4. Scope of Work ⑥ If the name under subparagraph 2 of paragraph 5 or the address under subparagraph 3 of the same paragraph is changed, the designated certification body must submit to the Minister of the Interior and Safety an application for change of designation details of the designated certification body (including electronic documents) in the form of Annex 21 , attaching documents (including electronic documents) that can prove such details. ⑦ When the Minister of the Interior and Safety receives an application for change pursuant to Paragraph 6, he/she shall verify the contents of the application for change, issue a certificate of designation of a certified institution in the form of Annex 20 , and announce the changed matters in the Official Gazette and on the internet homepage. Article 44 (Detailed Standards for Administrative Dispositions against Designated Certification Bodies, etc.) ① The detailed standards for administrative dispositions against designated certification bodies pursuant to Article 23, Paragraph 2 of the Act are as set forth in Attached Table 8 . ② In cases where the Minister of the Interior and Safety cancels the designation of a designated certification body or orders a suspension of business pursuant to Article 23, Paragraph 2 of the Act (including cases where a penalty surcharge is imposed in lieu of a suspension of business pursuant to Article 24, Paragraph 1 of the Act ), he/she shall publish such fact in the Official Gazette and on the internet homepage without delay. Article 44-2 (Application for Extension of Implementation Period for Improvement, Destruction, or Collection Order) Any person who intends to apply for an extension of the implementation period for an order to improve, destroy, or collect elevator safety parts or elevators pursuant to Article 25, Paragraph 3 of the Enforcement Decree shall submit to the Minister of the Interior and Safety, no later than 15 days before the end of the implementation period, an application for extension of the implementation period in Form No. 21-2 of the, with a certificate of safety confirmation (limited to cases where it must be attached pursuant to Article 25, Paragraph 4 of the Enforcement Decree). [This Article Newly Inserted July 26, 2023] Article 45 (Implementation Plan, etc.) ① The implementation plan pursuant to Article 26, Paragraph 2 of the Enforcement Decree shall include all of the following items: 1. Name of elevator safety part or elevator name 2. Model name (excluding elevators that have received individual elevator safety certification) and date of manufacture (in the case of imported elevator safety parts or elevators without a date of manufacture, the date of import) 3. Content and cause of violations falling under each subparagraph of Article 25 , Paragraph 1 and each subparagraph of Paragraph 2 of the Act (hereinafter referred to as “violations” in this Article) 4. Details of anticipated hazards and precautions in case of failure to correct violations 5. Method of rectification for violations, such as exchange, refund, or repair, and rectification period 6. Method of notification to consumers (including management entities) ② If the Minister of the Interior and Safety determines that the contents of the implementation plan under Paragraph 1 are insufficient to rectify the violations, the Minister may order supplementation. Chapter 4 Installation and Safety Management of Elevators Article 46 (Notification of Elevator Installation) ① An installation contractor pursuant to Article 2, subparagraph 6 , item ( c) of the Act shall report the installation of the elevator to the Corporation within 10 days from the date of completion of the elevator installation pursuant to Article 27 of the Act . ② The elevator installation report pursuant to Paragraph 1 shall be in accordance with Form No. 22 of the Attached Form . Article 47 (Application for Elevator Installation Inspection) If an elevator manufacturer or importer intends to undergo an installation inspection of an elevator (hereinafter referred to as “installation inspection”) pursuant to Article 28, Paragraph 1 of the Act , they must submit an application for installation inspection in the form of Annex 23 (including electronic documents) to the Corporation, attaching the documents listed in each of the following subparagraphs (including electronic documents). 1. Copy of Business Registration Certificate 2. Copy of Elevator Safety Certification (or Confirmation of Exemption from Elevator Safety Certification in cases where an exemption has been granted). 3. Installation drawings of elevators subject to installation inspection (including electrical and mechanical drawings) Article 48 (Scope of Duties of Elevator Safety Manager) The scope of duties of an elevator safety manager pursuant to the main text of Article 29, Paragraph 1 of the Act (hereinafter referred to as “Elevator Safety Manager”) shall be as follows: <Amended Feb. 21, 2022> 1. Preparation of regulations regarding elevator operation and management 2. Preparation and management of an emergency contact network in preparation for elevator accidents or breakdowns 3. Management and supervision of the maintenance business operator in cases where the self-inspection under Paragraph 1 of the same Article is performed on behalf of the maintenance business operator pursuant to Paragraph 4 of the Act 4. Notification of a serious accident pursuant to Article 48 , Paragraph 1, Subparagraph 1 of the Act (hereinafter referred to as “serious accident”) or a serious breakdown pursuant to Subparagraph 2 of the same Paragraph (hereinafter referred to as “serious breakdown”) 5. Elevator operation for the rapid rescue of users trapped inside the elevator ( only applicable if the elevator safety manager has received the relevant elevator management training pursuant to Annex 10 ) 6. Operation of evacuation elevators pursuant to Item 2, Subparagraph (a) 6) of Annex 1 ( only applicable if the elevator safety manager pursuant to Item 2 of Annex 9 has received the relevant elevator management training pursuant to Annex 10 ) 7. Other matters necessary for elevator management as determined and notified by the Minister of the Interior and Safety Article 49 (Qualification Requirements for Elevator Safety Managers) In the part other than each subparagraph of Article 29, Paragraph 2 of the Act , “certain qualification requirements prescribed by the Ordinance of the Ministry of the Interior and Safety”refers to the qualification requirements for elevator safety managers pursuant to Annex 9 . Article 50 (Notification of Appointment or Change of Elevator Safety Manager) In the event that a managing entity appoints or changes an elevator safety manager (or the managing entity itself in cases where the managing entity directly manages the elevator) pursuant to Article 29, Paragraph 3 of the Act, it shall submit to the Corporation, within 30 days from the date specified in each of the following subparagraphs, a Notification of Appointment or Change of Elevator Safety Manager in the form of Annex 24 (including electronic documents), attaching documents proving that the qualification requirements for an elevator safety manager pursuant to Annex 9 have been met (excluding cases where the managing entity directly manages the elevator, and including electronic documents). <Amended Jan. 24, 2025> 1. In cases where an elevator is newly installed ( excluding elevator replacement pursuant to Article 3 ) and the managing entity directly manages the elevator: the date of passing the installation inspection 2. In cases where an elevator is newly installed ( excluding elevator replacement pursuant to Article 3 ) and a new elevator safety manager is appointed: the date the elevator safety manager is appointed 3. In the event of a change in the elevator safety manager or management entity: The date on which the elevator safety manager or management entity was changed Article 51 (Educational Institutions for Elevator Management) In the main text of Article 29, Paragraph 5 of the Act , the term “institution prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the Corporation. Article 52 (Contents of Elevator Management Education, etc.) ① Education regarding elevator management pursuant to Article 29, Paragraph 5 of the Act (hereinafter referred to as “elevator management education”) shall be in accordance with the classifications in each of the following subparagraphs. <Amended Jan. 24, 2025> 1. New Training: The following training that must be received by elevator safety managers or management entities (in the case of a corporation, its representative) who have not received elevator management training a. Training for the commencement of management of a said elevator upon new installation ( excluding elevator replacement pursuant to Article 3 ) B. Training in cases where the elevator safety manager or managing entity responsible for the elevator has changed (including cases where the representative has changed in the case of a corporation). 2. Regular Training: Training that the elevator safety manager or the management entity (in the case of a corporation, its representative) must receive every three years from the date of completion of the previous elevator management training. ② The new training under Subparagraph 1, Item (a) of Paragraph 1 must be completed within three months from the date of new appointment of the elevator safety manager (or the date of passing the installation inspection in cases where the management entity directly manages the elevator), and the new training under Subparagraph 1, Item (b) of the same subparagraph must be completed within three months from the date of change of the elevator safety manager or the management entity (or the date of change of the representative in cases where the management entity is a corporation). <Amended Jan. 24, 2025> ③ Notwithstanding Paragraph 1, Subparagraph 2, if three years have elapsed since the date of completion of the previous elevator management training, new training pursuant to Subparagraph 1 of the same paragraph must be received. <Newly added Jan. 24, 2025> ④ The detailed contents and duration of elevator management training are as set forth in Attached Table 10. <Newly added Jan. 24, 2025> ⑤ Notwithstanding Paragraphs 2 and 3, the Corporation may postpone elevator management training for elevator safety managers managing elevators for which a safety inspection has been postponed pursuant to Article 32, Paragraph 3 of the Act , until the date on which the reason for such postponement ceases to exist. <Amended Jan. 24, 2025> ⑥ Elevator management training may be conducted through methods such as group training, on-site training, or internet-based distance learning. <Amended Jan. 24, 2025> ⑦ In addition to the matters prescribed in Paragraphs 1 through 6, matters necessary for elevator management education, such as educational subjects and training hours for each subject, shall be determined and announced by the Minister of the Interior and Safety . <Amended Jan. 24, 2025> Article 53 (Application for Elevator Safety Inspection) ① Where a managing entity seeks a safety inspection of an elevator under Article 32 (1) of the Act (hereinafter referred to as a “safety inspection”), it shall submit an application for safety inspection in attached Form No. 25 (including an electronic application), together with the documents specified in the following subparagraphs (including electronic documents, but only for an ad hoc inspection under Article 32 (1) 2 of the Act), to the Minister of the Interior and Safety. Where the Korea Elevator Safety Agency (hereinafter referred to as the “Agency”) or a corporation, institution or organization designated under Article 37 (1) of the Act to perform periodic inspections under Article 32 (1) 1 of the Act (hereinafter referred to as a “designated inspection institution”) is entrusted under Article 36 (1) of the Act to conduct all or part of safety inspection duties, the application shall be submitted to the Agency or the designated inspection institution, as applicable. This meaning of the Minister also applies in Article 57 (2). 1. Documents verifying the changes in cases falling under Article 32, Paragraph 1, Subparagraph 2, Item ( a) of the Act 2. In cases falling under Article 32, Paragraph 1, Subparagraph 2, Item (b) of the Act , a copy of the parts safety certification and related technical documents 3. Where Article 32 (1) 2 (c) of the Act applies, documents verifying the details of the repair performed ② Other necessary matters regarding the sending of notices related to safety inspection applications and the timing of safety inspection applications, etc., shall be determined and announced by the Minister of the Interior and Safety . Article 54 (Inspection Cycle, etc. for Periodic Inspections) ① The inspection cycle for periodic inspections pursuant to the part other than each item of Article 32, Paragraph 1, Subparagraph 1 of the Act (hereinafter referred to as “periodic inspection”) shall be one year (referring to every year from the date of receiving the installation inspection or the immediately preceding periodic inspection). ② Notwithstanding Paragraph 1, in the case of elevators falling under any of the following subparagraphs, the inspection cycle for periodic inspections shall be the period specified in each of the following subparagraphs from the date of the previous periodic inspection. <Amended Jan. 24, 2025> 1. Elevators that have passed 25 years from the date of installation inspection: 6 months. However, if an occasional inspection pursuant to Article 32, Paragraph 1, Subparagraph 2 of the Act (hereinafter referred to as “occasional inspection”) or a detailed safety inspection pursuant to Article 32 , Paragraph 1, Subparagraph 3 of the Act (excluding Subparagraph B) has been received before the due date of the periodic inspection cycle, the period shall be limited to 1 year for the periodic inspection immediately following said inspection. 2. Elevators for which two years have not elapsed since a serious accident or serious malfunction occurred due to a defect pursuant to Article 32, Paragraph 1, Subparagraph 3, Item B of the Act : 6 months 3. Elevators of each of the following items: 2 years a. Cargo elevator pursuant to Item 2, Subparagraph a, Subparagraph 9) of Annex 1 B. Automobile elevators pursuant to Item 2, Subparagraph (a) 10) of Annex 1 C. Small cargo elevator (Dumbwaiter) pursuant to Item 2, Subparagraph A, Item 11) of Annex 1 4. Elevators installed in detached houses pursuant to Item 1, Subparagraph (a) of Annex 1 of the Enforcement Decree of the Building Act : 2 years ③ In Article 32, Paragraph 1, Item 1, Subparagraph (c) of the Act , “other matters prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the use of a building or fixed facility where an elevator is installed. ④ The inspection period for periodic inspections shall be within 30 days before and after the due date of the periodic inspection cycle. <Amended Jan. 24, 2025> ⑤ If the inspection is passed within the inspection period pursuant to Paragraph 4, the regular inspection shall be deemed to have been received on the due date of the regular inspection cycle. However, if the managing entity applied for a regular inspection pursuant to Article 53, Paragraph 1 prior to the due date of the regular inspection cycle, but passed the inspection after the inspection period pursuant to Paragraph 4 had expired due to reasons not attributable to the managing entity, the regular inspection shall be deemed to have been received on the due date of the regular inspection cycle. <Newly added Jan. 24, 2025> ⑥ Where an ad hoc inspection or a detailed safety inspection pursuant to Article 32, Paragraph 1, Subparagraph 3, Items ( a) , (b), and (d) of the Act is received before the due date of the inspection cycle for the periodic inspection under the provisions of Paragraphs 1 and 2, the inspection cycle for said periodic inspection shall be calculated from the date the ad hoc inspection or the detailed safety inspection pursuant to Article 32, Paragraph 1, Subparagraph 3, Items (a), (b), and (d) of the Act was received. <Amended Jan. 24, 2025> ⑦ In the event that a safety inspection is postponed pursuant to Article 32, Paragraph 3 of the Act , the inspection cycle of the relevant periodic inspection shall be calculated from the date the postponed safety inspection is received. <Amended Jan. 24, 2025> Article 55 (Exclusions from Occasional Inspections) The phrase “cases prescribed by the Ordinance of the Ministry of the Interior and Safety, such as cases where inspection standards for modified elevators are relaxed” in Article 32, Paragraph 1, Subparagraph 2, Item ( a) of the Act refers to any of the following cases: 1. In cases where an elevator falling under any of the following subparagraphs is changed to a passenger elevator in accordance with Subparagraph 2, Item (a) 1) of Annex 1 a. Elevators for persons with disabilities pursuant to Item 2, Subparagraph a, Subparagraph 4) of Annex 1 B. Firefighting rescue elevator pursuant to Item 2, Subparagraph (a) 5) of Annex 1 C. Evacuation elevators pursuant to Item 2, Subparagraph (a) 6) of Attached Table 1 2. Other cases where the type of elevator has changed to the same level of inspection standards and is recognized by the Minister of the Interior and Safety as cases where periodic inspection is not required. Article 56 (Period for Safety Inspection of Unsuccessful Elevators) In the latter part of Article 32, Paragraph 2 of the Act , the phrase “period prescribed by the Ordinance of the Ministry of the Interior and Safety” means within four months from the date of failure in the safety inspection. Article 57 (Reasons for Postponement of Elevator Safety Inspection, etc.) ① The reasons for postponing a safety inspection pursuant to Article 32, Paragraph 3 of the Act are as follows: 1. Cases where normal operation of the elevator is impossible due to a serious defect in the building or fixed facility where the elevator is installed. 2. Where the managing entity has suspended the operation of the elevator (excluding elevators for which installation is mandatory under other laws) 3. In the event of other unavoidable circumstances, such as natural disasters. ② Any person who intends to apply for a postponement of a safety inspection pursuant to Article 32 , Paragraph 3 of the Act shall submit to the Minister of the Interior and Safety an application for postponement of a safety inspection in the form of Annex 26 (including electronic documents), attaching documents (including electronic documents) that can verify the reasons for the postponement of the safety inspection pursuant to each subparagraph of Paragraph 1. Article 58 (Certificate of Inspection Pass and Sign Prohibiting Operation) ① The certificate of inspection pass for elevators pursuant to Article 34, Paragraph 1 of the Act shall be in accordance with Form No. 27 of the Attached Form . ② The sign prohibiting elevator operation pursuant to Article 34 , Paragraph 2 of the Act shall be in accordance with Form No. 28 of the Attached Form . Article 59 (Application for Designation of Inspection Agency, etc.) ① Any corporation, organization, or institution seeking designation as an inspection agency pursuant to Article 37, Paragraph 1 of the Act shall submit to the Minister of the Interior and Safety an application for designation as an inspection agency (including electronic documents) in the form of Annex 29 , attaching the documents (including electronic documents) of each of the following subparagraphs. 1. Articles of incorporation of a corporation or bylaws of an organization 2. A business plan including the organization, personnel, and inspection facilities, etc., for performing periodic inspection duties 3. Business regulations regarding procedures and methods, etc. for performing periodic inspection duties 4. Documents proving that the designated inspection agency meets the designation criteria pursuant to Article 31 of the Enforcement Decree ② When the Minister of the Interior and Safety receives an application for designation under Paragraph 1, he/she shall verify the Certificate of Corporate Registration (applicable only to corporations) through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act. However, if the applicant does not consent, the applicant shall be required to attach the Certificate of Corporate Registration. ③ When the Minister of the Interior and Safety receives an application for designation pursuant to Paragraph 1, he/she shall notify the applicant of an examination plan including on-site inspection, etc., and conduct an examination in accordance with the examination plan. ④ If the Minister of the Interior and Safety recognizes that a person who has submitted an application for designation under Paragraph 1 has met the designation criteria for a designated inspection agency under Article 31 of the Enforcement Decree after reviewing the case under Paragraph 3 and deliberating on the case under the Committee, the Minister may designate that person as a designated inspection agency by determining the scope of business for periodic inspections. ⑤ When the Minister of the Interior and Safety designates a designated inspection agency pursuant to Paragraph 4, he/she shall issue a Designation Certificate for the Inspection Agency in the form of Annex 30 and announce the matters of each of the following subparagraphs in the Official Gazette and on the internet homepage. 1. Designation Date and Designation Number 2. Name of the designated inspection agency 3. Address of the designated inspection agency (including the workplace) 4. Scope of Work ⑥ If the name under subparagraph 2 of paragraph 5 or the address under subparagraph 3 of the same paragraph is changed, the designated inspection agency must submit to the Minister of the Interior and Safety an application for change of designation details of the designated inspection agency (including electronic documents) in the form of Annex 31 , attaching documents (including electronic documents) that can prove such details. ⑦ When the Minister of the Interior and Safety receives an application for change pursuant to Paragraph 6, he/she shall verify the contents of the application for change, issue a designation certificate for a designated inspection agency in the form of Annex 30 , and announce the changed matters in the Official Gazette and on the internet homepage. Article 60 (Detailed Standards for Administrative Dispositions against Designated Inspection Agencies, etc.) ① The detailed standards for administrative dispositions against designated inspection agencies pursuant to Article 37, Paragraph 2 of the Act are as set forth in Attached Table 11 . ② In cases where the Minister of the Interior and Safety cancels the designation of a designated inspection agency or orders a suspension of business pursuant to Article 37, Paragraph 2 of the Act (including cases where a penalty surcharge is imposed in lieu of a suspension of business pursuant to Article 38, Paragraph 1 of the Act ), he/she shall publish such fact in the Official Gazette and on the internet homepage without delay. Article 61 (Application for Registration of Maintenance Business, etc.) ① Any person who intends to register to engage in elevator maintenance business (hereinafter referred to as “maintenance business”) pursuant to the first part of Article 39, Paragraph 1 of the Act shall submit an application for registration of elevator maintenance business (including electronic documents) in the form of Annex 32 , attached with the documents (including electronic documents) specified in each of the following subparagraphs, to the Mayor or Provincial Governor having jurisdiction over the location of the principal office. In this case, the Mayor or Provincial Governor shall verify the certificate of business registration through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act , and shall require the applicant to attach the relevant documents if the applicant does not consent to the verification. <Amended Sep. 7, 2021; Jul. 29, 2026> 1. Deleted <July 29, 2026> 2. Business Plan 3. Documents proving that the registration standards for maintenance business pursuant to Article 33 and Annex 8 of the Enforcement Decree have been met 4. If the applicant (in the case of a corporation, the representative of the corporation) is a foreigner, documents classified according to the following items that can confirm that the applicant does not fall under any of the grounds for disqualification specified in each subparagraph of Article 40 of the Act a. In the case of a country that has concluded the “Convention Abolishing the Requirement of Legalization for Foreign Public Documents”: a document issued by the government or other competent authority of such country, or a statement of the relevant foreigner notarized by a notary public, for which the apostille has been issued by the authority in such country with the power to issue apostilles. B. In the case of a country that has not concluded the "Convention Abolishing the Requirement of Legalization for Foreign Public Documents": a document issued by the government or other competent authority of the country concerned, or a statement of the relevant foreign national notarized by a notary public and verified by the Korean consul residing in the country concerned. ② In the latter part of Article 39, Paragraph 1 of the Act , “matters prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the matters in each of the following subparagraphs. 1. Company Name 2. Location of the principal office 3. Number and location of workplaces 4. Representative 5. Types of elevators subject to maintenance pursuant to Item 1 of Annex 8 of the Enforcement Decree 6. Technical personnel ③ A person registered to engage in maintenance business (hereinafter referred to as the “maintenance business operator”) shall, in the event that any of the matters falling under each subparagraph of Paragraph 2 are changed, submit an application for change of registration for elevator maintenance business (including electronic documents) in the form of Annex 33, along with the documents (including electronic documents) listed in each of the following subparagraphs, to the Mayor or Provincial Governor having jurisdiction over the location of the principal office. In this case, if the matters under subparagraph 2 of Paragraph 2 are changed, the application for change of registration shall be submitted to the Mayor or Provincial Governor having jurisdiction over the location of the changed principal office. 1. Elevator Maintenance Business Registration Certificate 2. Documents verifying the changes (in the case of changes in technical personnel, this refers to the technical personnel status data) ④ In addition to the matters prescribed in paragraphs 1 through 3, necessary matters concerning the examination of applications for registration and change of registration of elevator maintenance business and the method of assigning registration numbers, etc. shall be determined and announced by the Minister of the Interior and Safety . Article 62 (Issuance of Maintenance Business Registration Certificate, etc.) ① The Mayor or Provincial Governor shall issue an elevator maintenance business registration certificate in the form of Annex 34 to a maintenance business operator who has registered pursuant to Article 61, Paragraph 1. The same shall apply to a maintenance business operator who has registered a change pursuant to Article 61, Paragraph 3 . ② A maintenance business operator who wishes to obtain a reissuance of the elevator maintenance business registration certificate pursuant to Paragraph 1 due to loss or damage must submit an application for reissuance of the elevator maintenance business registration certificate in the form of Annex 35 (including electronic documents) to the mayor or provincial governor. Article 63 (Registration Register for Maintenance Business) When a mayor or provincial governor issues a registration certificate for an elevator maintenance business pursuant to Article 62, Paragraph 1, they shall create and manage a registration register using the Elevator Safety Comprehensive Information Network. Article 64 (Reporting of Closure, Suspension, or Resumption of Maintenance Business) In accordance with Article 39, Paragraph 4 of the Act , any maintenance business operator who intends to close or suspend a maintenance business, or to resume a suspended business, shall submit to the Mayor or Provincial Governor the Report on Closure, Suspension, or Resumption of Elevator Maintenance Business ( Form No. 36 , including electronic documents), attaching the Certificate of Registration for Elevator Maintenance Business (applicable only to the case of reporting closure, and including electronic documents). However, if the Certificate of Registration for Elevator Maintenance Business cannot be attached due to reasons such as loss or damage, the reason may be stated in the Report on Closure, Suspension, or Resumption of Elevator Maintenance Business and submitted. <Amended July 29, 2026> Article 65 (Publication of Standard Maintenance Costs, etc.) ① Pursuant to Article 41, Paragraph 1 of the Act , the Minister of the Interior and Safety shall designate and publicly announce a specialized agency among the corporations, organizations, or institutions listed in each of the following subparagraphs that determines and publishes the amount serving as the standard for maintenance costs to be borne by the managing entity (hereinafter referred to as “Standard Maintenance Costs”). <Amended July 26, 2024> 1. The Korea Elevator Safety Agency 2. Association 3. A non-profit corporation established pursuant to Article 32 of the Civil Act to perform price survey duties, etc. ② If a specialized institution designated and notified pursuant to Paragraph 1 determines standard maintenance costs, it shall publish the details on its internet homepage, etc. ③ In addition to the matters prescribed in Paragraphs 1 and 2, necessary matters concerning the calculation criteria for standard maintenance costs, the contents of publication, and the timing of publication, etc., shall be determined and announced by the Minister of the Interior and Safety . Article 66 (Upper Limit on the Number of Elevators for Maintenance) In Article 43, Paragraph 1 of the Act , the term “monthly number of elevators for maintenance prescribed by the Ordinance of the Ministry of the Interior and Safety” refers to the number of elevators classified according to each of the following subparagraphs. <Amended July 29, 2026> 1. In cases where technical personnel of a maintenance business registered pursuant to Article 39, Paragraph 1 of the Act maintain elevators installed in a Special City, Integrated Special City, Metropolitan City, Special Self-Governing City, Province, or Special Self-Governing Province (hereinafter referred to as “City/Province”) where the maintenance business operator’s principal office or workplace is located: the number of units obtained by multiplying the number of technical personnel by 100 2. In cases where one or more technical personnel of a maintenance business registered pursuant to Article 39, Paragraph 1 of the Act maintain elevators installed in a City or Province where the maintenance business operator's principal office or workplace is not located: the number of units obtained by multiplying the number of technical personnel by 90. 3. In cases where a maintenance business operator who is a manufacturer or importer jointly maintains a portion of the elevators under Subparagraph 1 or 2 with another maintenance business operator: the number of elevators obtained by multiplying the number under Subparagraph 1 or 2 by 50 percent Article 67 (Detailed Standards for Administrative Dispositions against Maintenance Business Operators, etc.) ① The detailed standards for administrative dispositions against maintenance business operators pursuant to Article 44, Paragraph 1 of the Act are as set forth in Attached Table 12 . ② In cases where a mayor or provincial governor cancels the registration of a maintenance business or imposes a business suspension order pursuant to Article 44, Paragraph 1 of the Act (including cases where a penalty surcharge is imposed in lieu of a business suspension order pursuant to Article 45, Paragraph 1 of the Act ), they must announce such fact on the internet homepage, etc., without delay. ③ A person who has received a supplementary order pursuant to Article 44, Paragraph 2 of the Act shall supplement the information within the supplementary period and report to the mayor or provincial governor by attaching documents proving the results. Article 68 (Operation of Elevators for Persons with Disabilities) In Article 47 of the Act , “elevators for persons with disabilities prescribed by the Ordinance of the Ministry of the Interior and Safety”refers to inclined wheelchair lifts for persons with disabilities pursuant to Subparagraph 2, Item (c) of Annex 1 . Article 69 (Reporting and Investigation of Accidents) ① In the event of a serious accident or serious breakdown occurring pursuant to Article 48, Paragraph 1 of the Act, the managing entity ( including a maintenance business operator performing self-inspections on behalf of the entity pursuant to Article 31, Paragraph 4 of the Act) shall preserve data regarding the relevant accident or breakdown recorded in the defect verification device, etc., and notify the Corporation of the matters in each of the following subparagraphs without delay. <Amended Feb. 21, 2022> 1. Name and address of the building or fixed facility where the elevator is installed 2. Unique elevator number pursuant to Article 60 , Paragraph 1 of the Enforcement Decree 3. Date and time of accident or breakdown 4. Details of accident or breakdown 5. Extent of damage (including the number of trapped persons and those rescued in cases where people are trapped in an elevator or wheelchair lift) and details of emergency measures ② When the Corporation receives notification of matters concerning a serious accident or serious breakdown pursuant to Paragraph 1, it shall, without delay pursuant to Article 48, Paragraph 3 of the Act , prepare a report on a serious accident or serious breakdown in the form of Annex 37 (including electronic documents) and report it to the Minister of the Interior and Safety, the competent mayor or provincial governor, and the Elevator Accident Investigation Committee pursuant to Article 49, Paragraph 1 of the Act . ③ The Corporation shall conduct an investigation into the cause and circumstances, etc., of the elevator reported pursuant to Paragraph 2. ④ A person performing investigation duties pursuant to Paragraph 3 may request data classified according to each of the following subparagraphs from the managing entity and persons who have suffered damage due to a serious accident or serious malfunction (hereinafter referred to as “accident victims” in this Article) in accordance with Article 48, Paragraph 4 of the Act. <Newly added Jan. 24, 2025> 1. Data that can be requested from the managing entity: Closed-circuit television (CCTV) video information capable of verifying the situation before and after the occurrence of a major accident or major breakdown 2. Materials that may be requested from the accident victim: A medical certificate confirming the damage caused by a serious accident or serious breakdown (referring to one stating the results of the initial diagnosis conducted by a doctor within 7 days of the date of the serious accident or serious breakdown). ⑤ When a person performing investigation duties pursuant to Paragraph 3 requests data pursuant to Paragraph 4, he/she shall carry an identification showing his/her authority and present it to the managing entity or the accident victim. <Newly added Jan. 24, 2025> ⑥ Matters necessary for the composition of the investigation team and the reporting of investigation results, etc., for the investigation pursuant to Paragraph 3 shall be determined and announced by the Minister of the Interior and Safety . <Amended Jan. 24, 2025> Article 70 (Notification of Elevators, etc. Not Subject to Inspection) The Corporation or a designated inspection agency (referring to a designated inspection agency that has directly conducted a periodic inspection on an elevator that failed the safety inspection under Subparagraph 3) shall notify the competent Special Self-Governing City Mayor, Special Self-Governing Province Governor, or Mayor, County Governor, or District Head (the District Head refers to the head of an autonomous district; hereinafter the same applies) of the facts pursuant to each subparagraph of Article 50, Paragraph 1 of the Act by the date specified in each of the following subparagraphs. <Amended Sep. 8, 2020; Feb. 21, 2022; Jan. 24, 2025> 1. Elevators that have not undergone installation inspection: The day following the date of receipt of the elevator installation report pursuant to Article 27 of the Act 2. Elevators that have not undergone safety inspection: Dates according to the classifications in each of the following items a. Periodic inspection: The day following the due date of the inspection cycle for the periodic inspection pursuant to Article 54 b. Ad hoc inspection: The day after the ground requiring the ad hoc inspection arose C. Detailed safety inspection pursuant to Article 32, Paragraph 1, Subparagraph 3 of the Act : The day following the date on which the cause for undergoing the said detailed safety inspection occurred. 3. Elevators that failed the installation inspection or safety inspection: The day following the date of failure in the relevant installation inspection or safety inspection Article 71 (Signs for Suspension of Elevator Operation, etc.) ① The signs for suspension of elevator operation pursuant to Article 50, Paragraph 3 of the Act shall be in accordance with Form No. 38 of the Attached Form . ② The managing entity shall attach the elevator operation suspension sign issued pursuant to Article 50, Paragraph 3 of the Act to a location specified in each of the following subparagraphs so that users can clearly see it, in accordance with Paragraph 4 of the same Article . 1. Elevator: The center of the elevator door 2. Escalator: The center of the floor at the boarding platform entrance 3. Wheelchair lift: Location according to the classifications in each of the following items a. Vertical wheelchair lift pursuant to Item 1, Subparagraph c, Item 1) of Annex 1 : Center of the vertical wheelchair lift entrance B. Inclined wheelchair lift pursuant to Item 1, Subparagraph C, 2) of Annex 1 : The center of the control panel door and the center of the carrier floor Chapter 5. Reporting of Technicians' Career and Training Article 72 (Reporting of Career, etc. by Technicians) ① If a technician (hereinafter referred to as “technician”) pursuant to the first part of the part other than each subparagraph of Article 51, Paragraph 1 of the Act intends to report matters concerning workplace, career, qualifications, etc. (hereinafter referred to as “career, etc.”) pursuant to the first part other than each subparagraph of the same Paragraph, they must submit to the Minister of the Interior and Safety [in cases where the duties of receiving and managing reports on matters concerning career, etc. and issuing certificates regarding career, etc. have been entrusted to a Corporation or Association pursuant to Article 64, Paragraph 5, Subparagraphs 1 and 2 of the Enforcement Decree, the Minister shall attach documents (including electronic documents) capable of verifying career, etc.] the Technician Career Report Form (including electronic documents) in Annex 39 [referring to the Corporation or Association in cases where the duties of receiving and managing reports on matters concerning career, etc. and issuing certificates regarding career, etc. have been entrusted to a Corporation or Association. The same shall apply in Paragraphs 2 and 4 of this Article.] ② If the matters reported pursuant to Paragraph 1 are changed, the technician must submit to the Minister of the Interior and Safety, in accordance with the latter part of Article 51, Paragraph 1 of the Act , a report on change of technician career (including electronic documents) in Form No. 40 of the Appendix, with documents (including electronic documents) that can verify the changed contents attached. ③ The application form for the issuance of a certificate regarding the career, etc. of a technician pursuant to Article 51, Paragraph 2 of the Act shall be in accordance with Form No. 41 of the Attached Form, and the certificate regarding the career, etc. of a technician pursuant to the same paragraph shall be in accordance with Form No. 42 of the Attached Form . ④ The Minister of the Interior and Safety shall establish and operate a computer network for receiving and managing reports on matters concerning career, etc., and for issuing certificates regarding career, etc. ⑤ In addition to the matters prescribed in paragraphs 1 through 4, necessary matters concerning the receipt and management of reports regarding the career, etc. of technicians and the procedures and methods for issuing certificates regarding career, etc. shall be determined and announced by the Minister of the Interior and Safety . Article 73 (Contents and Hours of Technical and Job Training, etc.) ① The contents and hours of technical training under Article 52 (1) of the Act (hereinafter referred to as “technical training”) and job training under Article 52 (2) of the Act (hereinafter referred to as “job training”) shall be as specified in Annex 13. ② The cycle for technical training and job training shall be 3 years each. ③ Technical training and job training shall be conducted in the following ways: <Amended Feb. 21, 2022> 1. Group training 2. On-site training 3. Remote education ④ Evaluation of technical training and job training shall be conducted by the following methods: 1. The head of the educational institution shall determine the examination subjects, examination procedures, judgment criteria, question setting, examination methods and management, storage of examination papers, examination venues, examination supervision and grading, etc., for educational evaluation in accordance with the institution's own circumstances. 2. Trainees must attend at least 90% of the total training hours and receive a score of 60 or higher out of 100 points to complete the course. ⑤ Necessary matters concerning the step-by-step educational curriculum, subjects for each curriculum, and hours of training for each subject, etc., according to the technician's career experience, etc., shall be determined and announced by the Minister of the Interior and Safety . Article 74 (Application for Designation of Educational Institution, etc.) ① Any corporation, organization, or institution seeking designation as an institution dedicated to technical education or job training pursuant to Article 53, Paragraph 1 of the Act (hereinafter referred to as “educational institution”) shall submit to the Minister of the Interior and Safety an application for designation of an educational institution in the form of Annex 43 (including electronic documents), attaching the documents listed in each of the following subparagraphs (including electronic documents). 1. Articles of incorporation of a corporation or bylaws of an organization 2. A business plan including the organization, personnel, facilities, and equipment for carrying out technical training or job training tasks 3. Work regulations regarding procedures and methods, etc., for performing technical training or job training tasks 4. Documents proving that the educational institution meets the designation criteria pursuant to Article 45 of the Enforcement Decree ② When the Minister of the Interior and Safety receives an application for designation under Paragraph 1, he/she shall verify the Certificate of Corporate Registration (applicable only to corporations) through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act. However, if the applicant does not consent, the applicant shall be required to attach the Certificate of Corporate Registration. ③ When the Minister of the Interior and Safety receives an application for designation pursuant to Paragraph 1, he/she shall notify the applicant of an examination plan including on-site inspection, etc., and conduct an examination in accordance with the examination plan. ④ If the Minister of the Interior and Safety recognizes, as a result of the examination under paragraph 3, that the person who submitted the application for designation under paragraph 1 meets the criteria for designation of an educational institution under Article 45 of the Enforcement Decree, he/she shall issue a certificate of designation of an educational institution in the form of Annex 44 . Article 75 (Detailed Standards for Administrative Dispositions against Educational Institutions, etc.) ① The detailed standards for administrative dispositions against educational institutions pursuant to Article 53, Paragraph 2 of the Act are as set forth in Attached Table 14 . ② In cases where the Minister of the Interior and Safety cancels the designation of an educational institution or orders the suspension of operations pursuant to Article 53 , Paragraph 2 of the Act , he/she shall announce such fact in the Official Gazette and on the internet homepage without delay. Article 76 (Detailed Standards for Administrative Dispositions against Safety Management Technicians) The detailed standards for administrative dispositions against safety management technicians pursuant to Article 54, Paragraph 1 of the Act ( referring to technicians engaged in the duties specified in subparagraphs 3 through 7 of Article 51 , Paragraph 1 of the Act)are as set forth in Table 15 . Chapter 6 Promotion of the Elevator Safety Industry Article 77 (Elevator Safety Industry) The term “business prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 65, Paragraph 1, Subparagraph 4 of the Act refers to the businesses of each of the following subparagraphs. 1. Elevator design consulting services 2. Elevator Installation Supervision Business 3. Research and development and supply of equipment for elevator maintenance and inspection Article 78 (Method and Procedure for Selection of Excellent Safety Management Enterprises, etc.) ① Any person who wishes to be selected as an excellent safety management enterprise pursuant to Article 66, Paragraph 1 of the Act shall submit to the Minister of the Interior and Safety an application for selection as an excellent safety management enterprise (including electronic documents) in the form of Annex 45 , attaching the documents (including electronic documents) of each of the following subparagraphs. 1. Safety Management Plan and Results Report 2. Financial statements for the past 3 years 3. Tax invoices pursuant to Article 32 of the Value Added Tax Act for the past 3 years ② When the Minister of the Interior and Safety receives an application for selection pursuant to Paragraph 1, he/she shall formulate an evaluation plan including on-site inspection, etc., and notify the applicant. ③ When the Minister of the Interior and Safety receives an application for selection pursuant to Paragraph 1, he or she shall review it in accordance with the evaluation criteria notified by the Minister of the Interior and Safety , taking into consideration the matters in each of the following subparagraphs . 1. Evaluation Criteria 2. Scoring by Evaluation Item 3. Evaluation Method by Evaluation Item ④ The Minister of the Interior and Safety may select a person who has submitted an application for selection pursuant to Paragraph 1 as an excellent safety management company if they receive 85 points or more out of 100 as a result of the evaluation pursuant to Paragraph 3. ⑤ When the Minister of the Interior and Safety selects an excellent safety management company pursuant to Paragraph 4, he/ she shall issue a certificate of selection of an excellent safety management company in the form of Annex 46 . ⑥ In addition to the matters prescribed in paragraphs 1 through 5, necessary matters concerning the selection method and procedure, etc. of excellent safety management companies shall be determined and announced by the Minister of the Interior and Safety . Chapter 7 Supplementary Provisions Article 79 (Establishment and Operation of the Elevator Safety Comprehensive Information Network) The term “information prescribed by the Ordinance of the Ministry of the Interior and Safety” in Article 73, Paragraph 1, Subparagraph 14 of the Act refers to the information in each of the following subparagraphs. 1. Status of dispositions, such as cancellation of manufacturing or import business registration pursuant to Article 9 of the Act 2. Status of surcharges imposed on manufacturers and importers under Article 10 of the Act 3. Status of elevator installation notifications pursuant to Article 27 of the Act 4. Status of insurance coverage pursuant to Article 30 of the Act 5. Status of Dispositions, Including Cancellation of Maintenance Business Registration Pursuant to Article 44 of the Act 6. Status of surcharges imposed on maintenance business operators under Article 45 of the Act 7. Status of Dispositions Suspending Elevator Operation Pursuant to Article 50 of the Act 8. Status of Reporting of Technicians Pursuant to Article 51 of the Act 9. Status of fact-finding survey pursuant to Article 74 of the Act 10. Status of administrative fines imposed pursuant to Article 82 of the Act 11. Current status of buildings or fixed facilities where the location of installed elevators can be identified 12. Other matters related to elevator safety that the Minister of the Interior and Safety deems necessary to manage. Article 80 (Fact-finding Survey) ① When the Minister of the Interior and Safety conducts a fact-finding survey to ascertain the operational status, etc., of elevators falling under any of the subparagraphs of Article 74, Paragraph 1 of the Act, the scope or region of the elevators subject to the survey may be divided for the survey. ② In Article 74, Paragraph 2 of the Act , “matters prescribed by the Ordinance of the Ministry of the Interior and Safety, such as matters concerning the maintenance of registration standards” refers to the following matters: 1. Whether the registration standards for manufacturing or importing businesses are maintained pursuant to Article 6, Paragraph 2 of the Act and Article 10 of the Enforcement Decree 2. Status of outsourcing of self-inspections pursuant to Article 31 , Paragraph 4 of the Act 3. Whether the registration standards for maintenance businesses are maintained pursuant to Article 39 , Paragraph 2 of the Act and Article 33 of the Enforcement Decree. 4. Other matters that the Mayor or Provincial Governor deems necessary to investigate. ③ When a mayor or provincial governor conducts a fact-finding survey to identify matters falling under any of the subparagraphs of Paragraph 2 pursuant to Article 74, Paragraph 2 of the Act , they may divide the scope or region of the manufacturers, importers, or maintenance operators subject to the survey and conduct the survey. ④ When the Minister of the Interior and Safety or the Mayor or Provincial Governor conducts a fact-finding investigation pursuant to Article 74 , Paragraph 1 or 2 of the Act , they shall notify the subject of the investigation of the investigation plan, including the date, time, reason, and content of the investigation, at least 7 days before the start of the investigation. However, if it is deemed that the purpose of the investigation cannot be achieved if notified in advance due to the destruction of evidence, etc., they may not be notified in advance. ⑤ The Minister of the Interior and Safety or the mayor or provincial governor may conduct a joint fact-finding survey with the Corporation for efficient fact-finding. Article 81 (Fees) ① The fees pursuant to Article 76, Paragraph 1 of the Act shall be determined and announced by the Minister of the Interior and Safety . ② The Corporation or a designated inspection agency may reduce or waive all or part of the periodic inspection fees for elevators falling under any of the following subparagraphs, subject to the approval of the Minister of the Interior and Safety. 1. Elevators installed in nursing homes or elderly care facilities pursuant to Article 32, Paragraph 1 , Subparagraph 1 or Article 34, Paragraph 1 , Subparagraph 1 of the Senior Welfare Act (excluding nursing homes or elderly care facilities operated by collecting the full admission fee from residents pursuant to Article 14, Paragraph 1, Subparagraph 1, Item (d) or Article 18, Paragraph 1, Subparagraph 1, Item (d ) of the Enforcement Rules of the Senior Welfare Act). 2. Elevators installed in child care facilities pursuant to Article 52, Paragraph 1, Subparagraph 1 of the Child Welfare Act 3. Elevators installed in residential facilities for persons with disabilities pursuant to Article 58, Paragraph 1, Subparagraph 1 of the Welfare Act for Persons with Disabilities ③ The fee under Paragraph 1 may be paid in cash or by means of electronic money, electronic payment, etc. using an information and communications network pursuant to Article 14 of the Electronic Government Act . Article 82 (Review of Regulations) The Minister of the Interior and Safety shall review the validity of the matters set forth in each of the following subparagraphs every three years based on the reference dates specified in each of the following subparagraphs (meaning the period prior to the same date as the reference date of the year marking every third year) and take measures such as improvements. <Amended Feb. 21, 2022> 1. Scope of elevator maintenance parts pursuant to Article 8 : July 1, 2022 2. Scope of duties and qualification requirements for elevator safety managers pursuant to Articles 48 and 49 : July 1, 2019 3. Content, period, and frequency of elevator management training pursuant to Article 52 : July 1, 2019 4. Upper limit on the number of elevators under maintenance pursuant to Article 66 : July 1, 2022 ADDENDA <Ministry of the Interior and Safety Decree No. 105, Mar. 6, 2019> Article 1 (Enforcement Date)  This rule shall enter into force on March 28, 2019. Article 2 (Applicability to the Attachment of Suspension of Elevator Operation Signs)  The amended provisions of Article 71, Paragraph 2 shall apply from the time a suspension of elevator operation sign is issued after the enforcement of this Rule. Article 3 (Special Provisions Concerning the Inspection Cycle of Periodic Inspections) Notwithstanding  the amended provisions of Article 54, Paragraph 2, Subparagraphs 1 and 2, for elevators that have undergone periodic inspections in accordance with the former "Safety Management Act for Elevator Facilities" at the time of the enforcement of this Rule and fall under any of the following subparagraphs after six months have passed since the date of said periodic inspection, a periodic inspection must be received within two months from the date of enforcement of this Rule. In this case, a periodic inspection must be received every six months from the date of the periodic inspection. 1. Elevators for which two years have not passed since a serious accident or major breakdown occurred due to a defect 2. Elevators that received a completion inspection in accordance with the former "Elevator Facilities Safety Management Act" and for which 25 years have passed since the date of the completion inspection Article 4 (Transitional Measures Concerning the Monthly Number of Elevators Maintained by Maintenance Operators Who Are Manufacturers or Importers of Elevators) Any maintenance  operator who is a manufacturer or importer of elevators and whose monthly number of elevators maintained exceeds the ratio stipulated in the amended provisions of Article 66, Subparagraph 3 at the time of the enforcement of this Rule shall gradually reduce the ratio of the monthly number of elevators maintained jointly with other maintenance operators to a level not exceeding the ratios classified in each of the following subparagraphs. 1. Within one year from the effective date: 60 percent of the number of elevators pursuant to the amended provisions of Article 66, subparagraph 1 or 2 2. Within 2 years from the effective date: 50 percent of the number of elevators pursuant to the amended provisions of Article 66, subparagraph 1 or 2 Article 5 (Transitional Measures Concerning Reporting of Technician Career, etc.)  Technicians who have not reported matters concerning their career, etc. at the time of enforcement of this Rule shall, in accordance with the amended provisions of Article 72, Paragraph 1, submit to the Minister of the Interior and Safety [in cases where the duties of receiving and managing reports on matters concerning career, etc. and issuing certificates regarding career, etc. have been entrusted to the Corporation or Association pursuant to Article 64, Paragraph 5, Subparagraphs 1 and 2 of the Enforcement Decree, the Minister shall submit to the Corporation or Association] a technician career report form in accordance with the amended provisions of Form No. 39 attached hereto, with documents verifying career, etc. attached, within six months from the enforcement date of this Rule. Article 6 (Transitional Measures Concerning Bed Elevators, Emergency Elevators, and Small Elevators)  ① Bed elevators pursuant to Annex 1 of the former “Enforcement Rule of the Safety Management of Elevator Facilities Act” at the time of the enforcement of this Rule shall be deemed to be hospital elevators pursuant to the amended provisions of Item 2, Subparagraph (a) 3) of Annex 1. ② Emergency elevators pursuant to Annex 1 of the former Enforcement Rule of the Elevator Facilities Safety Management Act at the time of the enforcement of this Rule shall be deemed to be fire rescue elevators pursuant to the amended provisions of Item 2, Subparagraph (a) 5) of Annex 1. ③ Small elevators pursuant to Annex 1 of the former Enforcement Rule of the Elevator Facilities Safety Management Act at the time of the enforcement of this Rule shall be deemed residential elevators pursuant to the amended provisions of Item 7, Subparagraph (a) of Annex 1. Article 7 (Transitional Measures Concerning Standards for Administrative Dispositions)  ① Notwithstanding the amended provisions of Annex 3, Annex 6, Annex 8, Annex 12, and Annex 15, when applying standards for administrative dispositions for violations committed prior to the enforcement of this Rule, the former "Enforcement Rule of the Electrical Appliances and Household Goods Safety Management Act," the former "Enforcement Rule of the Quality Management and Industrial Product Safety Management Act," and the former "Enforcement Rule of the Elevator Facilities Safety Management Act" shall apply, respectively. ② Administrative dispositions received for violations committed prior to the enforcement of this rule shall not be included in the calculation of the number of violations pursuant to the amended provisions of Annex 3, Annex 12, and Annex 15. ③ Administrative dispositions received pursuant to Article 11 of the former “Electrical Appliances and Household Goods Safety Management Act” for violations committed prior to the enforcement of this rule shall be included in the calculation of the number of violations pursuant to the amended provisions of Annex 6. Article 8 (Transitional Measures Concerning Qualification Requirements for Elevator Safety Managers)  Elevator safety managers who, at the time of the enforcement of this Rule, are elevator safety managers under the former “Elevator Facilities Safety Management Act” and do not meet the qualification requirements under the amended provisions of Annex 9, shall meet the qualification requirements under the amended provisions of Annex 9 within six months from the date of enforcement of this Rule. Article 9 (Transitional Measures Concerning Forms) Forms under the former Enforcement Rule of the Elevator Facilities Safety Management Act in use when this Rule entered into force may be used alongside the forms prescribed by this Rule for six months from the date this Rule takes effect. Article 10 (Relationship with Other Laws and Regulations)  Where, at the time of the enforcement of this Rule, other laws and regulations refer to the former "Enforcement Rules of the Elevator Safety Management Act" or its provisions, and there are corresponding provisions in this Rule, it shall be deemed that this Rule or the relevant provisions of this Rule have been referred to in place of the former "Enforcement Rules of the Elevator Safety Management Act" or its provisions. ADDENDA <Ministry of the Interior and Safety Decree No. 198, Sep. 8, 2020> (Ministry of the Interior and Safety Decree on the Partial Amendment of Two Acts for the Comprehensive Transfer of Central Administrative Authority and Affairs, etc. to Local Governments) This rule shall take effect on January 1, 2021. ADDENDA <Ministry of the Interior and Safety Decree No. 274, Sep. 7, 2021> (Ministry of the Interior and Safety Decree on the Partial Amendment of 29 Laws for the Reorganization of Difficult Legal Terms) This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 319, Feb. 21, 2022> Article 1 (Enforcement Date)  This rule shall enter into force on March 2, 2022. Article 2 (Applicability to Safety Certification Processing Period)  In cases where an application for component safety certification, model elevator safety certification, or individual elevator safety certification was submitted pursuant to Article 12, Paragraph 1, Article 27, Paragraph 1, or Article 28, Paragraph 1 at the time of the enforcement of this Rule, and the certification result has not been notified, the processing period may be extended in accordance with the amended provisions of Article 12, Paragraph 3, Article 27, Paragraph 3, or Article 28, Paragraph 2. Article 3 (Transitional Measures Concerning Detailed Standards for Administrative Dispositions)  Notwithstanding the amended provisions of Annex 3, Annex 6, Annex 7, Annex 8, Annex 11, Annex 12, Annex 14, and Annex 15, administrative dispositions for violations committed prior to the enforcement of this Rule shall be governed by the former provisions. Article 4 (Transitional Measures Concerning Model Classification Standards for Elevator Safety Components)  Elevator safety components that received safety certification prior to the enforcement of this Rule shall be deemed to have received safety certification in accordance with the amended provisions of Annex 4. Article 5 (Transitional Measures Concerning Certificates of Passing Elevator Inspection)  Certificates of passing elevator inspection issued prior to the enforcement of this Rule shall be deemed to be certificates of passing elevator inspection issued in accordance with the amended provisions of Form No. 27. ADDENDA <Ministry of the Interior and Safety Decree No. 373, Jan. 5, 2023> (Ministry of the Interior and Safety Decree on the Partial Amendment of Two Acts for the Support of Economic Recovery of Small Business Owners) Article 1 (Enforcement Date)  This Rule shall enter into force on the date of its promulgation. Article 2 (Applicability to Standards for Administrative Dispositions)  The amended provisions of Articles 1 and 2 shall apply even when administrative dispositions are imposed after the enforcement of this Rule for violations committed prior to the enforcement of this Rule. ADDENDA <Ministry of the Interior and Safety Decree No. 420, July 26, 2023> This rule shall take effect from the date of its promulgation. ADDENDA <Ministry of the Interior and Safety Decree No. 500, July 26, 2024> This rule shall take effect on July 31, 2024. ADDENDA <Ministry of the Interior and Safety Decree No. 545, Jan. 24, 2025> Article 1 (Enforcement Date)  This rule shall enter into force on January 31, 2025. Article 2 (Applicability to Inspection Cycles, etc. of Periodic Inspections)  ① The amended provisions of the proviso to Article 54, Paragraph 2, Subparagraph 1 shall apply to elevators that have passed 25 years since the date of receiving the installation inspection, and which have received an occasional inspection or a detailed safety inspection pursuant to Article 32, Paragraph 1, Subparagraph 3 (excluding Subparagraph B) of the Act on or after August 1, 2024, but have not received a periodic inspection immediately thereafter. ② The amended provisions of the proviso to Article 54, Paragraph 5 shall also apply in cases where the managing entity applied for a periodic inspection pursuant to Article 53, Paragraph 1, prior to the effective date of this Rule, before the due date of the periodic inspection cycle. ADDENDA <Ministry of the Interior and Safety Decree No. 633, July 29, 2026> (Ministry of the Interior and Safety Decree on the Partial Amendment of Six Acts for the Linkage of Joint Use of Administrative Information) This rule shall take effect one month after the date of promulgation. [Attached Table 1] Detailed Types of Elevators by Structure or Use (Related to Article 2) [Appendix 2] Parts for Elevator Maintenance (Related to Article 8) [Appendix 3] Detailed Standards for Administrative Dispositions against Manufacturers and Importers (Related to Article 10, Paragraph 1) [Appendix 4] Standards for Classification of Elevator Safety Components and Elevator Models (Related to Articles 11 and 26) [Appendix 5] Marking of Parts Safety Certification or Elevator Safety Certification and Marking of Exemption (Related to Article 17, Paragraph 2; Article 24, Paragraph 1; Article 33, Paragraph 2; and Article 40, Paragraph 1) [Appendix 6] Detailed Standards for Administrative Dispositions Regarding Cancellation, etc. of Parts Safety Certification (Related to Article 25, Paragraph 1) [Appendix 7] Detailed Standards for Administrative Dispositions Regarding Cancellation, etc. of Elevator Safety Certification (Related to Article 41, Paragraph 1) [Appendix 8] Detailed Standards for Administrative Dispositions against Designated Certification Bodies (Related to Article 44, Paragraph 1) [Appendix 9] Qualification Requirements for Elevator Safety Managers (Related to Article 49) [Attached Table 10] Details and Duration of Elevator Management Training (Related to Article 52, Paragraph 4) [Appendix 11] Detailed Standards for Administrative Dispositions against Designated Inspection Agencies (Related to Article 60, Paragraph 1) [Appendix 12] Detailed Standards for Administrative Dispositions against Maintenance Contractors (Related to Article 67, Paragraph 1) [Appendix 13] Content and Hours of Technical and Job Training (Related to Article 73, Paragraph 1) [Appendix 14] Detailed Standards for Administrative Dispositions against Educational Institutions (Related to Article 75, Paragraph 1) [Appendix 15] Detailed Standards for Administrative Dispositions against Safety Management Technicians (Related to Article 76, Paragraph 1) [Attachment Form No. 1] Application for Registration of Manufacturing or Importing Business [Attachment Form No. 2] Application for Change of Registration for Manufacturing or Importing Business [Attachment Form No. 3] Registration Certificate for Manufacturing or Importing Business [Attachment Form No. 4] Application for Reissuance of Manufacturing or Import Business Registration Certificate [Attachment Form No. 5] Report on Manufacturing or Import Business (Closure, Suspension, Resumption) [Attached Form No. 5-2] Application for Deferral of the Surcharge Payment Deadline [Attached Form No. 5-3] Application for Payment of a Surcharge in Installments [Attachment Form No. 6] Application for Parts Safety Certification [Attachment Form No. 7] Parts Safety Certification [Attachment Form No. 8] Application for Change of Parts Safety Certification [Attachment Form No. 9] Application for Exemption from Parts Safety Certification [Attachment Form No. 10] Confirmation of Exemption from Parts Safety Certification [Attached Form No. 11] Application for Periodic Review of Elevator Safety Parts [Attachment Form No. 12] Application for Model Elevator Safety Certification [Attachment Form No. 13] Application for Individual Elevator Safety Certification [Attachment Form No. 14] Elevator Safety Certification [Attachment Form No. 15] Application for Change of Elevator Safety Certification [Attachment Form No. 16] Application for Exemption from Elevator Safety Certification [Attachment Form No. 17] Confirmation of Exemption from Elevator Safety Certification [Attached Form No. 18] Application for Periodic Review of Elevators [Attached Form No. 19] Application for Designation as a Certification Institution [Attachment Form No. 20] Designation Certificate for Designated Certification Bodies [Attached Form No. 21] Application for Amendment of the Designation of a Certification Institution [Form No. 21-2] Application for Extension of Compliance Period (Improvement Order, Destruction Order, Collection Order) [Attachment Form No. 22] Elevator Installation Notification [Form No. 23] Application for Installation Inspection [Attachment Form No. 24] Notification of Elevator Safety Manager (Appointment, Change) [Form No. 25] Application for Safety Inspection [Attachment Form No. 26] Application for Postponement of Safety Inspection [Form No. 27] Elevator Inspection Certificate [Attachment Form No. 28] Prohibition of Elevator Operation [Form No. 29] Application for Designation as a Designated Inspection Agency [Attachment Form No. 30] Designation Certificate for Designated Inspection Agency [Form No. 31] Application for Change of Designated Inspection Agency [Attachment Form No. 32] Application for Registration of Elevator Maintenance Business [Attachment Form No. 33] Application for Change of Registration for Elevator Maintenance Business [Attachment Form No. 34] Elevator Maintenance Business Registration Certificate [Attachment Form No. 35] Application for Reissuance of Elevator Maintenance Business Registration Certificate [Attachment Form No. 36] Report on (Closure, Suspension, Resumption) of Elevator Maintenance Business [Form No. 37] (Major Accident, Major Breakdown) Report [Attachment Form No. 38] Suspension of Elevator Operation [Attachment Form No. 39] Technician Career Report [Attachment Form No. 40] Report of Change in Technician Career [Attached Form No. 41] Application for a Certificate of a Technician's Career, etc. [Form No. 42] Certificate of Technician's Experience, etc. [Attachment Form No. 43] Application for Designation as an Educational Institution [Attachment Form No. 44] Designation of Educational Institution [Attachment Form No. 45] Application for Selection as an Excellent Safety Management Company [Attachment Form No. 46] Certificate of Selection as an Excellent Safety Management Company