Regulations on Housing Construction Standards, etc.
285833 · 2026-11-07
Chapter 1 General Provisions
Article 1 (Purpose) The purpose of this Decree is to prescribe matters delegated pursuant to Articles 2, 35, 38 through 41, 41-2, 42, and 51 through 53 of the Housing Act concerning construction standards for housing, installation standards for ancillary facilities and welfare facilities, standards for site development, display of performance grades for multi-unit housing, recognition of performance grades and performance inspection of floor impact sound insulation structures for multi-unit housing, recognition procedures for industrialized housing, construction standards for energy-saving eco-friendly housing and health-friendly housing, and long-life housing, as well as matters necessary for the implementation thereof. <Revised 1993.2.20, 1999.9.29, 2003.11.29, 2005.6.30, 2006.1.6, 2009.10.19, 2013.2.20, 2013.6.17, 2013.12.4, 2014.6.27, 2014.12.23, 2016.8.11, 2017.10.17, 2022.8.4>
Article 2 (Definitions) The definitions of terms used in this Decree are as follows. Amended Feb. 20, 1993, Dec. 30, 1994, Aug. 27, 1998, Sep. 29, 2001, Apr. 30, 2002, Dec. 26, 2003, Nov. 29, 2005, Jun. 30, 2006, Jan. 6, 2007, Mar. 27, 2009, Jan. 7, 2009, Sep. 21, Nov. 5, 2009, July 6, 2010, Dec. 8, 2011, Jun. 17, 2013, Apr. 29, 2014, Dec. 28, 2015, Aug. 11, 2016, Jan. 12, 2021, Dec. 6, 2022, May 6, 2026 2026.6.30>
1. Delete<2003.11.29>
2. Delete<1999.9.29>
3. "Community Facilities for Residents" refers to facilities used jointly by residents of the relevant multi-unit housing or supporting the residents' daily lives, and includes the facilities listed in each of the following subparagraphs.
A. Senior Citizen Center
B. Children's Playground
C. Daycare Center
D. Resident Exercise Facilities
E. Library [Including Information and Cultural Facilities and small libraries pursuant to Article 4, Paragraph 2, Subparagraph 1, Item A of the Library Act (hereinafter referred to as "small library")]
B. Resident Education Facilities (referring to educational places for residents of multi-unit housing that are not for profit)
G. Youth Training Facilities
Ah. Residents' Rest Facilities
Okay. Study room
D. Residents' Meeting Hall
K. Shared kitchen and shared dining hall
T. Shared Laundry Room
P. Social welfare facilities installed within a public housing complex pursuant to Article 2 of the Special Act on Public Housing
H. Together Care Center pursuant to Article 44-2 of the Child Welfare Act (hereinafter referred to as the "Together Care Center")
Ge. Community childcare sharing center under Article 19 of the "Childcare Support Act"
N. Other facilities equivalent to the facilities listed in subparagraphs (a) through (g) that are recognized by the authority approving the business plan pursuant to Article 15, Paragraph 1 of the Housing Act (hereinafter referred to as the "Act") (hereinafter referred to as the "Business Plan Approval Authority")
4. The term "medical facility" refers to clinics, dental clinics, Korean medicine clinics, midwifery centers, branch offices of public health centers, hospitals (excluding isolation hospitals such as infectious disease hospitals), Korean medicine hospitals, and pharmacies.
5. The term "residents' exercise facilities" refers to outdoor and indoor exercise facilities (including facilities corresponding to reported sports facility businesses under the Act on the Installation and Use of Sports Facilities), community sports facilities, and other similar facilities installed for the physical activities of residents.
6. The term "housing for single persons" refers to a dwelling falling under any of the following items.
A. Housing constructed by an employer for the residence of an employed worker who leads a single life (including living temporarily separated from family or in a dormitory due to working conditions; hereinafter the same applies)
B. Housing constructed by the State, local governments, or public corporations for the residence of workers leading a single life
7. The term "trunk road" refers to a road pursuant to Article 5 of the Enforcement Decree of the Housing Act.
8. The term "access road" refers to a road accessible to pedestrians and vehicles that extends from a main road to the entrance of a housing complex.
9. The term "City and County Areas" refers to city areas and county areas with a population of less than 200,000 among areas outside the Capital Area as defined by the Capital Area Planning Act.
Article 3 (Scope of Application) This Decree shall apply to housing, ancillary facilities, and welfare facilities constructed by a project entity under Subparagraph 10 of Article 2 of the Act after obtaining approval for a housing construction project plan pursuant to Article 15, Paragraph 1 of the Act, and to land developed after obtaining approval for a land development project plan. <Amended Nov. 29, 2003; Jun. 30, 2005; Jan. 6, 2006; Oct. 19, 2009; Aug. 11, 2016>
Delete Article 4 <2017.10.17>
Delete Article 5 <2017.10.17>
Article 6 (Facilities within the Complex)
① Notwithstanding regions or districts under relevant laws and regulations, only the facilities specified in each of the following subparagraphs may be constructed or installed in a housing complex. <Amended Sep. 29, 1999; Jul. 1, 2000; Dec. 26, 2002; Nov. 29, 2003; Jun. 30, 2005; Oct. 19, 2009; Apr. 10, 2012; Aug. 11, 2016; Oct. 17, 2017; Jan. 12, 2021>
1. Facilities
2. Welfare facilities. In this case, facilities pursuant to subparagraphs 9 through 11 of Article 7 of the Enforcement Decree of the Housing Act shall apply only when multi-unit housing with an exclusive area per household (referring to the area used solely for residential purposes, calculated in accordance with the Ordinance of the Ministry of Land, Infrastructure and Transport; hereinafter the same applies) of 50 square meters or less is constructed in the relevant housing complex with a scale falling under any of the following items.
A. 300 households or more
B. More than half of the total number of households in the relevant housing complex
3. Trunk Facilities
4. Urban and rural planning facilities under Article 2, Subparagraph 7 of the National Land Planning and Utilization Act
② In any of the following cases, facilities not restricted in the area or district to which the relevant building belongs, in accordance with relevant laws and regulations, may be constructed or installed in addition to the facilities under Paragraph 1. <Amended Dec. 4, 2013>
1. In the case of constructing housing in a commercial area pursuant to Article 36, Paragraph 1, Subparagraph 1, Item (b) of the "Act on Planning and Utilization of National Land" (hereinafter referred to as "commercial area")
2. In the case of constructing a residential building as a complex building with non-residential facilities adjacent to a general road with a width of 12 meters or more (excluding roads within a housing complex)
3. In the case of constructing a complex building comprising housing and hotel facilities pursuant to Article 2, Subparagraph 4 of the Special Act on the Expansion of Tourist Accommodation Facilities [excluding ancillary facilities pursuant to Article 3, Subparagraph 3, Items (a) (only applicable to karaoke bar businesses and entertainment bar businesses), (d), (f), and (g) of the Enforcement Decree of the same Act; hereinafter referred to as "hotel facilities") in a semi-residential area pursuant to Article 30, Subparagraph 1, Item (c) of the Enforcement Decree of the Act on Planning and Utilization of National Land (hereinafter referred to as "semi-residential area") or a semi-industrial area pursuant to Subparagraph 3, Item (c) of the same Act (hereinafter referred to as "semi-industrial area"),
③ Delete <2003.11.29>
[Title Revised 2021.1.12]
Article 7 (Special Provisions for Application)
① The provisions of Article 13 and Article 37, Paragraph 1 shall not apply to industrialized housing pursuant to Article 51 of the Act or to industrialized housing constructed by applying new construction technology. <Amended Feb. 20, 1993; Sep. 29, 1999; Nov. 29, 2003; Aug. 11, 2016>
② In cases where a market and a housing unit are constructed as a mixed-use building pursuant to Subparagraph 13 of Article 7 of the Enforcement Decree of the Housing Act, Articles 9, 9-2, 10, 13, 26, 35, 37, 38, 50, 52, and 55-2 shall not apply. <Amended Sep. 29, 1999; Jun. 17, 2013; Oct. 17, 2017>
③ In the case of constructing housing in a commercial area, Articles 9, 9-2, 10, 13, 50, and 52 shall not apply. <Amended Mar. 15, 2011; Jun. 17, 2013>
④ Articles 9, 9-2, 10, 13, and 50 shall not apply in any of the following cases. <Amended 2013.12.4>
1. In cases where a residential building is constructed as a complex building with non-residential facilities adjacent to a general road with a width of 12 meters or more (excluding roads within a housing complex), and falls under any of the following subparagraphs
a. In the case of construction in a semi-residential area where the total floor area of facilities other than housing is one-tenth or more of the total floor area of the building
B. In cases where construction is carried out in an area other than a semi-residential zone, and the total floor area of facilities other than housing is one-fifth or more of the total floor area of the building
2. In the case of constructing a mixed-use building containing housing and hotel facilities in a semi-residential or semi-industrial area
⑤ In the case of constructing housing for single persons (excluding housing for sale), Articles 13, 27, 32 Paragraph 1, 52, and 55-2 shall not apply. <Amended June 17, 2013>
⑥ Notwithstanding the provisions of this Decree, in cases where it is deemed particularly necessary in light of the nature and function of housing constructed and supplied for low-income workers, or rental housing under the "Special Act on Private Rental Housing" and the "Special Act on Public Housing," or other multi-unit housing, construction standards for housing and installation standards for ancillary facilities and welfare facilities may be separately prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Amended Dec. 23, 1994; Dec. 30, 1994; Jun. 30, 2005; Feb. 29, 2008; Mar. 23, 2013; Dec. 28, 2015>
7. In the case of a reconstruction project pursuant to Article 2, Subparagraph 2, Item (c) of the Urban and Residential Environment Improvement Act, where the authority granting the project implementation approval recognizes that it is not dangerous or harmful to the residential environment, Article 9-2, Paragraph 1 shall not apply. <Amended 2003.6.30, 2005.6.30, 2007.7.24, 2013.6.17, 2018.2.9>
⑧ In cases where welfare housing for the elderly is constructed in accordance with the "Elderly Welfare Act," Articles 28, 34, 52, and 55-2 shall not apply. <Newly added Aug. 27, 1998; Jun. 30, 2005; Jun. 17, 2013>
⑨ Article 55-2 shall not apply in cases where facilities recognized by the authority approving the project plan (in the case of a redevelopment promotion district, the authority approving the project implementation or the authority approving the implementation plan) as satisfying the requirements of each of the following subparagraphs are installed in lieu of the installation of community facilities for residents near a housing complex within an Administrative City pursuant to Article 2, Subparagraph 1 of the "Special Act on the Construction of the Multifunctional Administrative City in the Yeongi-Gongju Area for Follow-up Measures for the New Administrative Capital" and a Redevelopment Promotion District pursuant to Article 2, Subparagraph 1 of the "Special Act on the Promotion of Urban Redevelopment." <Newly added 2007.7.24, 2013.6.17, 2021.1.5>
1. It shall be equipped with a scale and functions equivalent to or exceeding the level of community facilities for residents.
2. There shall be no significant difference from community facilities installed within the complex in terms of ease of access and efficiency of use
10. When constructing urban-type residential housing, Articles 9, 10 Paragraph 2, 13, 31, 35, and 55-2 shall not apply. However, in the case of constructing housing with 150 or more households falling under any of the following subparagraphs, Article 55-2 shall apply. <Newly added 2009.4.21, 2010.4.20, 2011.6.9, 2013.6.17, 2014.10.28, 2016.6.8, 2016.8.11, 2025.1.21>
1. Apartment-type housing pursuant to Article 10, Paragraph 1, Subparagraph 1 of the Enforcement Decree of the Housing Act (limited to cases where there are 150 or more households with an exclusive area exceeding 60 square meters per household)
2. Cluster-type row houses pursuant to Article 10, Paragraph 1, Subparagraph 2 of the Enforcement Decree of the Housing Act
3. Cluster-type multi-family housing pursuant to Article 10, Paragraph 1, Subparagraph 3 of the Enforcement Decree of the Housing Act
11. In the case of an urban-type residential housing that satisfies all the requirements of the following subparagraphs, in addition to the provisions excluded from application pursuant to Paragraph 10, Articles 9-2, 10 Paragraphs 3 and 4, 12 Paragraph 2, 15, 16 Paragraphs 1 and 2, 37 Paragraph 5, 50, and 64 shall not apply during the period the housing is used as rental housing. <Newly added 2021.1.12, 2022.2.11, 2025.1.21, 2026.9.8>
1. Change the use of Class 1 neighborhood living facilities, Class 2 neighborhood living facilities, facilities for the elderly and children, training facilities, office facilities, lodging facilities, or factories (limited to knowledge industry centers pursuant to Article 2, Item 13 of the Act on Promotion of Industrial Agglomeration and Factory Establishment) under Items 3, 4, 11, 12, 14, 15, or 17 of Annex 1 of the Enforcement Decree of the Building Act, to urban residential housing (limited to cases where the exclusive area per household is 60 square meters or less).
2. To be used as a rental housing falling under any of the following subparagraphs
A. Long-term public rental housing under Article 2, Subparagraph 1 of the "Act on Support for Improving the Quality of Life of Tenants of Long-term Public Rental Housing" (hereinafter referred to as "long-term public rental housing")
B. Publicly supported private rental housing under Article 2, Subparagraph 4 of the Special Act on Private Rental Housing
⑫ In the case of remodeling pursuant to Subparagraph 25, Item (c) of Article 2 of the Act, the following subparagraphs shall apply. <Newly added 2014.4.24, 2014.10.28, 2016.8.11, 2021.1.5, 2021.1.12>
1. Articles 9, 9-2, 14, 14-2, 15, and 64 shall not apply. However, with respect to parts extended vertically or extended into a separate building, Articles 9, 14, 14-2, and 15 (only applicable in cases of extension into a separate building) shall apply.
2. Article 55-2 shall not apply if the project plan approval authority recognizes that the community facilities after remodeling possess a scale and function equivalent to or exceeding the level of the community facilities at the time of the use inspection of the housing subject to remodeling.
Article 8 (Relationship with Other Laws)
① A housing complex shall be deemed a single site pursuant to the provisions of Article 3, Paragraph 1, Subparagraph 4 of the Enforcement Decree of the Building Act. However, land separately partitioned or transferred for the installation of welfare facilities shall be deemed a separate site. <Amended May 30, 1992; June 30, 2005>
② In the case of Paragraph 1, the area of roads, plazas, and park land designated as urban or county planning facilities within a housing complex shall not be included in the site area for the calculation of the building coverage ratio or floor area ratio. <Amended Apr. 22, 2003; Apr. 10, 2012>
③ Except for matters prescribed in this Decree regarding construction standards for housing and installation standards for ancillary and welfare facilities, matters shall be governed by the Building Act, the Water Supply Act, the Sewerage Act, the Act on the Guarantee of Convenience Promotion for Persons with Disabilities, the Elderly, and Pregnant Women, etc., the Act on the Installation and Management of Firefighting Facilities, and other relevant laws and regulations. <Newly added 2014.10.28, 2017.1.26, 2022.11.29>
Chapter 2 Layout of Facilities, etc.
Article 9 (Establishment of Noise Prevention Measures)
① The project owner shall ensure that the noise level at the point where the multi-unit housing is constructed (hereinafter referred to as "outdoor noise level") is less than 65 decibels; provided, however, that if it is 65 decibels or higher, the project owner shall establish noise prevention measures pursuant to Article 42, Paragraph 1 of the Act by installing soundproofing facilities such as sound barriers and soundproof forests (noise-blocking forests) so that the noise level at the construction point of the multi-unit housing is less than 65 decibels. However, in cases where the multi-unit housing is constructed in an urban area pursuant to Article 36 of the National Land Planning and Utilization Act or in an area designated pursuant to Article 27 of the Noise and Vibration Control Act, and satisfies all of the standards in each of the following subparagraphs, the main text shall not apply to the portion of the multi-unit housing that is 6 stories or higher. <Revised 2007.7.24, 2010.6.28, 2013.6.17, 2016.8.11, 2021.1.5, 2026.6.30>
1. The noise level measured in the living room with all windows and doors installed within the unit closed (hereinafter referred to as "indoor noise level") shall be 45 decibels or less.
2. Each unit of a multi-unit dwelling shall be equipped with ventilation facilities that comply with the standards prescribed in accordance with Article 87, Paragraph 2 of the Enforcement Decree of the Building Act.
② The noise measurement standards for outdoor and indoor noise levels pursuant to Paragraph 1 shall be announced by the Minister of Land, Infrastructure and Transport in consultation with the Minister of Climate, Energy and Environment. <Newly added 2007.7.24, 2008.2.29, 2013.3.23, 2025.10.1>
③ Delete <2013.6.17>
④ Delete <2013.6.17>
⑤ In the first part of Article 42, Paragraph 2 of the Act, the phrase "where a housing construction area prescribed by Presidential Decree is adjacent to a road" refers to any of the following cases. However, this shall be excluded in cases where the housing construction area is included in the project zone specified in Item 1 of Annex 3 of the Enforcement Decree of the Environmental Impact Assessment Act, provided that noise reduction measures have been established through an environmental impact assessment, consultation with the managing authority of the relevant road has been completed, and an implementation plan for the development project has been established. <Newly added 2013.6.17, 2014.7.14, 2016.8.11>
1. In cases where there is a housing construction area within 300 meters of an expressway pursuant to Article 11 of the Road Act
2. Where a housing construction area is located within 150 meters of a general national road pursuant to Article 12 of the Road Act (only applicable to roads exclusively for motor vehicles or roads with 6 or more lanes in both directions) and a Special City or Metropolitan City road pursuant to Article 14 of the same Act (only applicable to roads exclusively for motor vehicles)
6. When calculating the distances specified in each subparagraph of Paragraph 5, the distance from the boundary line of the road (or the boundary line between the road and the sidewalk in cases where a sidewalk is installed) to the outer wall surface of the nearest multi-unit dwelling shall be used as the standard. <Newly added 2013.6.17>
[Title Revised 2013.6.17]
Article 9-2 (Protection from Noise, etc.)
① Multi-unit housing, children's playgrounds, medical facilities (excluding pharmacies), kindergartens, daycare centers, community care centers, and senior citizen centers (hereinafter referred to as "multi-unit housing, etc." in this Article) shall be located at a horizontal distance of at least 50 meters from the outer boundary line of the facilities listed in each of the following subparagraphs (referring to the outer surface of a fence or wall; in the absence of a fence or wall, referring to the site boundary line; hereinafter the same applies). <Amended 2014.10.28, 2016.3.29, 2018.2.9, 2021.1.5, 2024.1.2, 2025.10.1, 2026.6.30>
1. Factories falling under any of the following subparagraphs [excluding factories whose relocation has been confirmed pursuant to the "Act on Promotion of Industrial Agglomeration and Factory Establishment" and which the project plan approval authority has acknowledged and publicly notified that there is no impediment to the construction of multi-unit housing, etc. in the vicinity; and in the case of residential areas pursuant to Article 36, Paragraph 1, Subparagraph 1, Item A of the "Act on Planning and Utilization of National Land" or district unit planning zones pursuant to Article 51, Paragraph 3 of the same Act (residential type only), only factories that the project plan approval authority has acknowledged and publicly notified as being harmful to the residential environment]
A. Factories emitting specific hazardous air pollutants pursuant to Article 2, Subparagraph 9 of the Air Environment Preservation Act
B. Factories equipped with air pollutant emission facilities pursuant to Article 2, Subparagraph 11 of the Air Environment Preservation Act, which correspond to the scale of Class 1 to Class 3 workplaces as specified in Annex 1 of the Enforcement Decree of the same Act
C. Factories corresponding to the scale of Class 4 and Class 5 workplaces pursuant to Annex 1-3 of the Enforcement Decree of the Air Environment Preservation Act, which are factories in industries notified by the Minister of Land, Infrastructure and Transport in consultation with the Minister of Climate, Energy and Environment. However, in cases where multi-unit housing, etc. is constructed pursuant to a reconstruction project under Article 2, Subparagraph 2, Item C of the Urban and Residential Environment Improvement Act (limited to reconstruction projects for housing constructed for which a project plan approval was applied for under the Housing Construction Promotion Act prior to its amendment by Act No. 6916, the Housing Act Amendment Act, prior to June 5, 1982), factories corresponding to the scale of Class 5 workplaces that have been recognized and notified by the project plan approval authority as not posing a danger or harm to the residential environment of the said multi-unit housing, etc. shall be excluded.
D. Factories equipped with noise-emitting facilities pursuant to Article 2, Subparagraph 3 of the "Noise and Vibration Control Act." However, this shall not apply if the noise level of the relevant factory, measured in accordance with the Noise and Vibration Control Act at the point where multi-unit housing, etc. is to be located, is 50 decibels or less and does not affect the multi-unit housing, etc., or if the level can be reduced to 50 decibels or less by installing soundproofing facilities such as sound barriers or soundproof forests.
2. Hazardous material storage and treatment facilities pursuant to Annex 1 of the Enforcement Decree of the Building Act
3. Other facilities that the project plan approval authority recognizes as particularly harmful to the residential environment (including facilities for which an installation plan has been finalized)
② Notwithstanding Paragraph 1, in the case of facilities listed in each of the following subparagraphs, multi-unit housing, etc. (excluding kindergartens, daycare centers, and community care centers in the case of Subparagraph 1) may be located at a horizontal distance of 25 meters or more from the outer boundary of the relevant facility. <Newly added 2026.6.30>
1. Among the facilities under Paragraph 1, Subparagraph 2, natural gas filling stations for automobiles installed at gas stations (including petroleum sales handling stations) or city bus depots (only applicable if the total internal volume of gas storage pressure vessels is 20 cubic meters or less)
2. Among the factories referred to in the main text of Paragraph 1, Subparagraph 1, Item (d), where the distance from a building or structure on which a noise-emitting facility is installed (referring to the noise-emitting facility itself in cases where there is no building or structure) to the outer boundary line of the factory is 50 meters or more
③ When arranging multi-unit housing, etc. in accordance with Paragraphs 1 and 2, soundproof forests shall be installed in the housing complex portion between the multi-unit housing, etc. and the facilities specified in each subparagraph of Paragraph 1 and Paragraph 2. However, this shall not apply if other facilities are present. <Amended Jan. 5, 2021; Jun. 30, 2026>
[This Article Newly Established 2013.6.17]
Article 10 (Arrangement of Multi-unit Housing)
① Delete <1996.6.8>
② The distance from the boundary line of a road (including roads within a housing complex, but excluding roads installed in pilotis and used solely as sidewalks) and a parking lot (excluding parking lots installed in basements, pilotis, or other similar structures, and their access roads) to the outer wall of a multi-unit dwelling (including balconies or other similar structures; hereinafter the same applies) shall be at least 2 meters, and necessary landscaping measures, such as planting, shall be taken in the space set back. However, this shall not apply to roads falling under any of the following subparagraphs that are separated into a sidewalk and a roadway. <Amended Jan. 7, 2009; Jun. 29, 2012>
1. Roads installed in the pilotis where the first floor of a multi-unit dwelling has a pilotis structure (limited to those equipped with pedestrian safety facilities recognized by the project plan approval authority)
2. In cases where residential and non-residential facilities are constructed as a single building and the first floor is a non-residential facility, a road installed adjacent to said non-residential facility (limited to those equipped with pedestrian safety facilities recognized by the project plan approval authority)
3. A road installed adjacent to a side wall where the exterior wall of a multi-unit dwelling is a side wall without openings
③ Housing complexes shall be arranged to meet the requirements of each of the following subparagraphs so as not to hinder firefighting activities in the event of a disaster, such as a fire. <Amended 2016.6.8, 2021.1.5>
1. Install passageways to enable fire trucks to access each household in the multi-unit dwelling.
2. Gate posts or barriers at the entrances of housing complexes shall be installed to allow the passage of fire trucks.
④ The height and form, etc., of each building within a housing complex shall be arranged in such a manner that they harmonize with the surrounding landscape and enhance the aesthetics of the area; and the Minister of Land, Infrastructure and Transport may prescribe and announce matters necessary for the arrangement, etc., of housing complexes to improve the design of multi-unit housing. <Newly Added 2013.6.17>
[Title Revised 1996.6.8]
Article 11 (Utilization of Basement Floors) Basement floors installed in a housing complex where multi-unit housing is constructed shall be used for neighborhood living facilities pursuant to Article 7, Subparagraphs 1 and 2 of the Enforcement Decree of the Housing Act (hereinafter referred to as "neighborhood living facilities." However, this Article excludes substations, water purification plants, and pumping stations; provided, in the case of substations, that substations for multi-unit housing constructed by an electric business operator pursuant to Article 2, Subparagraph 2 of the Electric Power Business Act on its own land for persons engaged in the installation and operation of facilities pursuant to Article 3, Subparagraph 1 of the Enforcement Decree of the Power Development Promotion Act, and for buildings where housing and non-housing buildings are constructed in combination within the same structure and the project plan approval authority recognizes that there is no impediment to residential stability), parking lots, community facilities for residents, and housing (only structures used as the exclusive residential portion of a first-floor unit in cases where the project plan approval authority recognizes that there is no impediment to the residential environment of the relevant housing), and other facilities pursuant to relevant laws and regulations It may be used for permitted purposes, and its structure and facilities must comply with the standards under Article 53 of the Building Act. <Amended 2005.6.30, 2006.1.6, 2008.10.29, 2009.10.19, 2013.6.17, 2017.10.17>
[Wholly Revised 1999.9.29]
Article 12 (Complex Construction with Housing)
① Accommodation facilities (excluding hotel facilities constructed in commercial, semi-residential, or semi-industrial areas), entertainment facilities, performance halls, factories, hazardous materials storage and processing facilities, and other facilities deemed by the project plan approval authority to impede the residential environment shall not be constructed as mixed-use buildings with housing. However, exceptions shall be made in any of the following cases: <Revised 1992.7.25, 1996.6.8, 2003.6.30, 2005.6.30, 2008.6.5, 2009.7.30, 2011.3.15, 2011.8.30, 2013.3.23, 2013.12.4, 2014.10.28, 2017.1.17, 2018.2.9>
1. In the case of constructing a complex building pursuant to a redevelopment project under Article 2, Subparagraph 2, Item (b) of the Urban and Residential Environment Improvement Act
2. In cases where entertainment facilities, accommodation facilities, or performance halls are constructed as a mixed-use building with housing, provided that all of the following requirements are met
a. The relevant complex building shall have 50 or more stories or a height of 150 meters or more.
B. In the case of constructing recreational facilities as a mixed-use building with residential units, all of the following requirements must be met.
1) Recreational facilities and residential housing shall be structurally separated
2) The project plan approval authority shall recognize that there is no impediment to the protection of the residential environment
3. In cases where a factory is constructed as a mixed-use building comprising housing and residential units within an urban high-tech logistics complex pursuant to Article 2, Subparagraph 6-2 of the Act on the Development and Operation of Logistics Facilities, provided that all of the following requirements are met
a. The relevant factory shall not be a factory falling under any of the items of Article 9-2, Paragraph 1, Subparagraph 1.
B. Logistics facilities within the housing complex where the relevant mixed-use building is constructed shall be installed in the basement.
C. The project plan approval authority shall recognize that there is no impediment to the protection of the residential environment.
② In cases where residential housing and non-residential facilities (excluding community facilities) are constructed in combination within the same building, the entrances, stairs, elevators, etc., of the residential housing shall be structured to be separated from the non-residential facilities, thereby ensuring residential safety—such as the protection of privacy, crime prevention, and fire prevention—and protecting the residential environment from noise, odors, etc. However, this shall not apply to lodging facilities and performance halls where the project plan approval authority recognizes that residential safety—such as the protection of privacy, crime prevention, and fire prevention—and the residential environment can be protected from noise, odors, etc., in the case of constructing a complex building with 50 or more stories or a height of 150 meters or more. <Amended June 5, 2008, October 28, 2014>
Chapter 3 Structure and Facilities of Housing
Article 13 (Standard Scales) The floor plan and dimensions of each part of a dwelling shall conform to the dimensions and standard scales prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. However, this shall not apply to dwellings constructed with special designs, structures, or materials recognized by the project plan approval authority. <Amended Dec. 23, 1994; Dec. 30, 1994; Feb. 29, 2008; Mar. 23, 2013; Jun. 17, 2013>
Article 14 (Boundary Walls Between Households, etc.)
① Boundary walls between individual households in multi-unit dwellings and boundary walls between multi-unit dwellings and facilities other than residential buildings shall be of a fire-resistant structure and shall be of a structure falling under any one of the following subparagraphs. <Amended 1994.12.23, 1994.12.30, 1998.12.31, 2008.2.29, 2013.3.23, 2021.1.5>
1. Reinforced concrete structures or steel-reinforced concrete structures having a thickness (including the thickness after applying cement mortar, plaster, gypsum plaster, or other similar materials) of 15 centimeters or more
2. Plain concrete, concrete block, brick, or stone structures having a thickness (including the thickness after applying cement mortar, plaster, gypsum plaster, or other similar materials) of 20 centimeters or more
3. Concrete slabs used as prefabricated housing components with a thickness of 12 centimeters or more
4. In addition to those specified in Subparagraphs 1 through 3, structures designated by the President of the Korea Institute of Construction Technology for their sound insulation performance in accordance with standards prescribed and notified by the Minister of Land, Infrastructure and Transport.
② The boundary wall pursuant to Paragraph 1 shall extend to the underside of the roof or to the floor slab of the immediately above floor, and shall be installed so as not to have any parts that obstruct sound insulation. In this case, if the structure of the boundary wall is brickwork, it shall be constructed so that no gaps are formed in the joint areas. <Amended 2017.10.17>
③ Delete <2013.5.6>
④ Delete <2013.5.6>
⑤ Notwithstanding the provisions of Paragraphs 1 and 2, in cases where a boundary wall between households is installed on a balcony of a floor three stories or higher in a multi-unit dwelling, an escape opening usable for evacuation in the event of a fire, etc., may be installed in the boundary wall, or the structure of the boundary wall may be made of a lightweight structure that is easily destructible. However, this shall not apply if a warehouse or other similar facility is installed in the boundary wall. <Newly added 1992.7.25>
⑥ In cases where an escape route is installed or the structure of a boundary wall is made of a lightweight structure, etc., pursuant to Paragraph 5, signs or similar markers containing information regarding such cases shall be attached or installed in an easily identifiable location. <Newly added 2014.12.23>
[Title Revised 2021.1.5]
Article 14-2 (Floor Structure) The inter-floor floors within a household of a multi-unit dwelling (excluding bathroom floors; hereinafter the same applies in this Article) shall satisfy all of the standards in each of the following subparagraphs. <Amended Jan. 17, 2017; Aug. 4, 2022; Jul. 9, 2024; May 6, 2026>
1. The thickness of concrete slabs shall be 210 millimeters or more [150 millimeters for multi-family housing with a rigid frame structure (referring to a structure in which load-bearing forces are transmitted through beams and columns; hereinafter the same applies in this Article)]. However, inter-floor slabs of housing falling under any of the following subparagraphs shall be exempt.
A. Industrialized housing recognized pursuant to Article 51, Paragraph 1 of the Act
B. Timber structure (referring to a structure in which the main structural components are composed of timber or wood products in accordance with the "Act on the Sustainable Use of Timber") Multi-family housing
2. Each inter-floor slab shall be a structure equipped with floor impact sound insulation performance [referring to performance in which the floor's lightweight impact sound (referring to floor impact sound caused by relatively light and hard impacts) and heavyweight impact sound (referring to floor impact sound caused by heavy and soft impacts) are each 49 decibels or less]. However, this shall not apply to the inter-floor slabs specified in each of the following subparagraphs.
A. Inter-floor slabs of multi-unit housing with frame structure
B. Inter-floor slabs of parts prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, such as balconies and entrances, among multi-unit dwellings other than those specified in Subparagraph A.
[This Article Newly Established 2013.5.6]
Article 14-3 (Walls and Windows, etc.)
① When constructing multi-unit housing with 500 or more households, windows and doors at wall joints or in spaces where heating facilities are installed must possess condensation prevention performance in accordance with the standards prescribed and notified by the Minister of Land, Infrastructure and Transport.
② Any person intending to construct a multi-unit dwelling falling under Paragraph 1 shall include detailed drawings for condensation prevention in areas vulnerable to condensation, such as the joints between walls and ceilings of living rooms and bedrooms within a unit (including the joints between walls and ceilings of walk-in closets or built-in furniture if such closets or built-in furniture are installed in a bedroom), ceiling areas of top-floor units, and wall areas of underground parking lots and elevator halls, in the design documents pursuant to Article 33, Paragraph 2 of the Act. <Amended Aug. 11, 2016; Oct. 25, 2016>
③ The Minister of Land, Infrastructure and Transport may determine and announce specific details regarding the contents, etc. of the preparation of detailed drawings for condensation prevention pursuant to Paragraph 2.
[This Article Newly Established 2013.5.6]
Article 15 (Elevators, etc.)
① Multi-unit dwellings with six or more floors shall be equipped with passenger elevators with a capacity of at least six people per unit, in accordance with the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. However, this shall not apply to multi-unit dwellings falling under the provisions of Article 89 of the Enforcement Decree of the Building Act. <Amended May 30, 1992; December 23, 1994; December 30, 1994; September 29, 1999; June 30, 2005; February 29, 2008; March 23, 2013>
② In the case of multi-unit dwellings with 10 or more floors, the passenger elevators referred to in Paragraph 1 shall be constructed as emergency elevators. <Amended July 24, 2007>
③ Multi-unit dwellings with 10 or more floors shall be equipped with freight elevators that meet the standards of each of the following subparagraphs and are capable of transporting household goods, etc. <Amended Sep. 27, 1993; Apr. 30, 2001; Dec. 30, 2016>
1. The load capacity shall be 0.9 tons or more
2. One side of the elevator's width or length shall be at least 1.35 meters, and the other side shall be at least 1.6 meters.
3. In the case of multi-unit housing with stairwells, install in each stairwell
4. In the case of corridor-type multi-unit housing, one unit shall be installed for up to 100 households; however, if the number of households exceeds 100, one additional unit shall be installed for every 100 households.
④ Passenger elevators or emergency elevators pursuant to the provisions of Paragraph 1 or 2 that comply with the standards of each subparagraph of Paragraph 3 may also be used as freight elevators.
⑤ Article 64 of the Building Act shall apply mutatis mutandis to the structure of passenger elevators, emergency elevators, and freight elevators and the structure of their landings pursuant to the provisions of Paragraphs 1 through 3. <Amended May 30, 1992; June 30, 2005; October 29, 2008>
Article 16 (Stairs)
① The dimensions of each part of stairs installed in buildings within a housing complex or outdoors shall conform to the standards in the following table. <Revised 2014.10.28>
<img src="http://www.law.go.kr/flDownload.do?flSeq=22783239" alt="img22783239" >
(Unit: centimeter)
┌───────────┬────┬────┬────┐
Type of Stairs Effective Width Ride Height Ride Width
├───────────┼────┼────┼────┤
Shared stairs 120 or more 18 or less 26 or more
├───────────┼────┼────┼────┤
Outdoor stairs of a building 90 or more 20 or less 24 or more
└───────────┴────┴────┴────┘
</img>
② The stairs pursuant to Paragraph 1 shall be installed appropriately in accordance with the provisions of each of the following subparagraphs. <Amended 1992.7.25, 2001.4.30, 2006.1.6, 2009.10.19, 2014.10.28>
1. For stairs exceeding 2 meters in height (excluding stairs within individual units), a landing with a width of at least 120 centimeters and a width greater than the effective width of the relevant stairs shall be installed at intervals of no more than 2 meters (3 meters in the case of stairs in machine rooms or water tank rooms). However, for stairs installed at the entrances of each building, landings may be installed at intervals of no more than 2.5 meters in height, limited to the first floor.
2. Delete <2014.10.28>
3. The floor of the stairs shall be constructed to prevent slipping.
③ Stairwells of multi-unit housing of the stairwell type shall comply with the standards of each of the following subparagraphs.
1. The entrance door of each unit facing the stairwell shall not obstruct passage on the stairs.
2. Install an opening effective for smoke exhaust at the top of the stairwell
3. Indicate the floor number for each floor of the stairwell
4. The finishes of the walls and ceilings of the stairwell (including the substrate for the finish) shall be made of non-combustible or semi-non-combustible materials.
④ Except for the matters prescribed in Paragraphs 1 through 3, Articles 34, 35, and 48 of the Enforcement Decree of the Building Act shall apply mutatis mutandis to standards regarding the installation and structure of stairs. <Amended May 30, 1992; Sep. 29, 1999; June 30, 2005; October 28, 2014>
⑤ Delete <2013.6.17>
[Title Revised 2013.6.17]
Article 16-2 (Doors)
① The glass installed on the entrance doors of each building within the housing complex shall be safety glass (referring to glass that is not penetrated by the impact of a 45-kilogram weight falling from a height of 75 centimeters; hereinafter the same applies).
② Ground-level entrances of each building within the housing complex and entrances connecting the underground parking lot to the underground entrances of each building must be equipped with an electronic access system (referring to a system that allows opening and closing doors using passwords, access cards, etc.).
③ Automatic emergency door opening and closing devices, having received performance certification pursuant to Article 40, Paragraph 1 of the Act on the Installation and Management of Firefighting Facilities and product inspection pursuant to Paragraph 2 of the same article, shall be installed on the rooftop access doors of each building within a housing complex. However, access doors on rooftops without evacuation spaces shall be excluded. <Newly added Feb. 29, 2016; Nov. 29, 2022>
4. The electronic access control system installed pursuant to Paragraph 2 and the automatic emergency door opening/closing device installed pursuant to Paragraph 3 shall be linked with the firefighting system in the event of an emergency, such as a fire, so that the locked state is automatically unlocked. <Amended Feb. 29, 2016>
[This Article Newly Established 2013.6.17]
Article 17 (Corridor)
① Delete <2014.10.28>
② The corridors of multi-unit dwellings of the corridor type shall comply with the standards of each of the following subparagraphs.
1. Install drains in corridors open to the outside air and ensure that floor drainage is not obstructed.
2. In double corridors, at least one opening facing the outside air shall be installed every 40 meters or less to ensure adequate natural lighting and ventilation.
3. The finishes of the walls and ceilings of the corridor (including the substrate for the finish) shall be made of non-combustible or semi-non-combustible materials.
Article 18 (Handrails)
① Handrails installed on buildings or outdoors within a housing complex shall be constructed using reinforced concrete, safety glass that does not scatter upon breakage, or materials with strength and durability (in the case of metal, only those that do not corrode or have been treated with anti-corrosion agents such as plating or rust prevention), ensuring that the handrails are installed in a safe structure. However, handrails installed indoors may be made of wood. <Amended 1992.7.25, 2009.1.7, 2013.6.17, 2021.1.5>
② The dimensions of each part of the handrail shall conform to the standards of each of the following subparagraphs. <Amended Sep. 29, 1999, Apr. 22, 2003>
1. Height of handrail: At least 120 centimeters from the finished floor surface. However, in the case of handrails installed on interior stairs, handrails installed in the middle of stairs, or other similar handrails installed in places with low risk, the height may be at least 90 centimeters.
2. Spacing of handrail balusters: Net dimension 10 centimeters or less
③ Handrails conforming to the provisions of Paragraphs 1 and 2 shall be installed on windows of dwellings with three or more stories (excluding cases where the height from the finished floor surface to the top surface of the window sill is 110 centimeters or more, or where a balcony or similar structure is located immediately below the window).
④ In the case of housing where railings are installed in locations directly exposed to outside air, at least one device for inserting a flagpole must be installed on the relevant railing or window frame for each household. However, if the project plan approval authority deems it difficult to install such a device considering user safety and the materials of the railings or window frames, it shall be installed at the ground-level entrances of each building in accordance with the Ordinance prescribed by the Ministry of Land, Infrastructure and Transport. <Amended Jan. 12, 2021, May 6, 2026>
Article 19 Deleted <1996.6.8>
Article 20 Deleted <1996.6.8>
Delete Article 21 <2014.10.28>
Article 22 (Convenience Facilities for Persons with Disabilities, etc.) Convenience facilities related to persons with disabilities that must be installed in ancillary facilities and welfare facilities within a housing complex shall be in accordance with the provisions of the “Act on the Guarantee of Promotion of Convenience for Persons with Disabilities, the Elderly, Pregnant Women, etc.” <Amended June 30, 2005>
[Wholly Revised 1998.2.24]
Delete Article 23 <2014.10.28>
Article 24 Deleted <2014.10.28>
Chapter 4 Facilities
Article 25 (Access Roads)
① A housing complex for the construction of multi-unit housing must be adjacent to a main road or have an access road leading from the main road to the complex. In this case, the width of the adjoining road and the width of the access road shall be as shown in the following table.
<img src="http://www.law.go.kr/flDownload.do?flSeq=22783224" alt="img22783224" >
(Unit: Meter)
┌─────────────┬────────────────────┐
Total number of households in the housing complex Width of abutting main roads or access roads
├─────────────┼────────────────────┤
Less than 300 households 6 or more
│ │ │
300 households or more Less than 500 households 8 or more
│ │ │
500 households or more Less than 1,000 households 12 or more
│ │ │
1,000 households or more, less than 2,000 households, 15 or more
│ │ │
2,000 households or more 20 or more
└─────────────┴────────────────────┘
</img>
② In cases where there are two or more housing complexes and there is only one access road to said housing complex, the width of said access road shall be calculated based on the total number of households obtained by summing the number of households in all housing complexes using said access road. <Newly added Sep. 29, 1999>
③ If there are two or more access roads to a housing complex where multi-unit housing is being constructed and they meet the standards of the following table, the provisions of Paragraph 1 may not apply. In this case, a road with a width of 4 meters or more but less than 6 meters shall be deemed an access road only if it is within 200 meters of the main road in terms of travel distance. <Amended Sep. 29, 1999; Jun. 8, 2016>
<img src="http://www.law.go.kr/flDownload.do?flSeq=24779275" alt="img24779275" >
┌─────────────┬──────────────┐
Among the access roads with a width of 4 meters or more of the total number of households in the housing complex
Sum of the widths of the 2 access roads
├─────────────┼──────────────┤
Less than 300 households 10 meters or more
300 households or more Less than 500 households 12 meters or more
500 households or more, less than 1,000 households, 16 meters or more
1,000 households or more, less than 2,000 households, 20 meters or more
Over 2,000 households Over 25 meters
└─────────────┴──────────────┘
</img>
④ In the case of constructing multi-unit housing outside of urban areas, the width of a main road abutting the housing complex or the width of a main road connected to the access road of the housing complex shall be equal to or greater than the standard for the width of the main road abutting the main road or the width of the access road pursuant to the provisions of Paragraph 1; and if there are two or more access roads to the housing complex, the width of the main road shall be equal to or greater than the standard for the width of each access road pursuant to the standards of Paragraph 3. <Newly added 1994.12.30, 1999.9.29, 2001.4.30, 2002.12.26>
⑤ Delete <2016.6.8>
Article 26 (Roads within a Housing Complex)
① In a housing complex where multi-unit housing is constructed, a road with a width of at least 7 meters (excluding pedestrian-only roads and bicycle paths) including a sidewalk with a width of at least 1.5 meters must be installed. <Amended Jul. 24, 2007; Jun. 17, 2013>
② Notwithstanding Paragraph 1, in any of the following cases, the width of a road may be 4 meters or more. In such cases, a sidewalk may not be installed on the relevant road. <Amended June 17, 2013>
1. In cases where the number of households in a multi-unit dwelling using the road is less than 100 and the road is a dead-end road with a length of less than 35 meters
2. Other cases where the project plan approval authority deems it unavoidable, such as dead-end roads within a housing complex
③ Roads within a housing complex shall be designed as streamlined roads, or the design speed (referring to the speed serving as the basis for road design) shall be 20 kilometers per hour or less through measures such as uneven road surface paving or the installation of speed bumps. <Newly Added 2013.6.17>
④ On roads within a housing complex where 500 or more multi-unit dwellings are being constructed, at least one Child Safety Protection Zone conforming to the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport shall be installed to allow for the stopping of school buses. <Newly Added 2013.6.17>
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, necessary matters concerning installation standards, etc. for roads and traffic safety facilities installed in housing complexes shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Amended 1994.12.23, 1994.12.30, 2007.7.24, 2008.2.29, 2013.3.23, 2013.6.17>
[Title Revised 2007.7.24]
Article 27 (Parking Lot)
① Parking lots shall be installed in housing complexes in accordance with the standards set forth in each of the following subparagraphs (fractions below the decimal point shall be considered as one unit). <Amended 2010.7.6, 2011.3.15, 2012.6.29, 2013.5.31, 2014.10.28, 2016.6.8, 2016.8.11, 2021.1.12, 2022.2.11, 2023.12.5, 2024.4.16, 2025.1.21, 2026.9.8>
1. In housing complexes, parking lots must be installed with a number of parking spaces equal to or greater than that calculated based on the ratio of the number of spaces per area specified in the following table, using the total exclusive area of the housing units as a basis; provided that the number of parking spaces per household must be at least 1 (or 0.7 if the exclusive area per household is 60 square meters or less). However, considering regional vehicle ownership rates, etc., the installation standards may be strengthened by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province (referring to a Special Self-Governing Province without local government entities such as Cities or Counties within its jurisdiction), City, County, or Autonomous District within the scope of one-fifth (or one-half if the exclusive area per household is 60 square meters or less).
<img src="http://www.law.go.kr/flDownload.do?flSeq=22783268" alt="img22783268" >
┌────────┬─────────────────────────────────┐
By Housing Size (Exclusive Parking Space Installation Standards (Vehicles/Square Meter)
Area: square meters)
A. Special City B. Metropolitan City/Special City C. Subparagraphs A and B D. Other Areas
City areas other than autonomous cities and counties
Cities within the metropolitan area and within the capital area
County area of the region
│ │ │ │ │ │
├────────┼─────┼────────┼─────────┼────────┤
85 or less 1/75 1/85 1/95 1/110
├────────┼─────┼────────┼─────────┼────────┤
Over 85 1/65 1/70 1/75 1/85
└────────┴─────┴────────┴─────────┴────────┘
</img>
2. Notwithstanding Subparagraph 1, urban residential housing (excluding cases where the number of floors used as housing is constructed up to 5 or 6 floors in accordance with the proviso to Subparagraph 2 or Subparagraph 3 of Article 10, Paragraph 1 of the Enforcement Decree of the Housing Act among cluster-type row houses or cluster-type multi-family houses) must install parking lots so that the number of parking spaces per household is at least 1 (0.6 spaces if the exclusive area per household is 30 square meters or more and 60 square meters or less, and 0.5 spaces if the exclusive area per household is less than 30 square meters). However, considering the vehicle ownership rate by region, etc., the requirements may be strengthened or relaxed by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province (referring to a Special Self-Governing Province where there are no local governments, such as Cities or Counties, within its jurisdiction), City, County, or Autonomous District according to the classifications in each of the following subparagraphs.
A. Urban-type residential housing constructed within a travel distance of 500 meters from facilities falling under Subparagraphs A and B of Article 2, Item 13 of the Special Act on Private Rental Housing, provided that all of the following requirements are met: Installation standards relaxed by up to 7/10.
1) It must be public rental housing under Article 2, Subparagraph 1, Item (a) of the Special Act on Public Housing
2) The lease shall be granted on the condition that the lessee does not own a vehicle during the lease period. However, for persons with disabilities, etc. pursuant to Article 2, Paragraph 2 of the Welfare Act for Persons with Disabilities, the requirements for vehicle ownership may be determined differently by ordinance of the Special City, Metropolitan City, Special Self-Governing City, Province, or Special Self-Governing Province.
3) The exclusive area per household shall be 60 square meters or less
B. Other cases: Strengthening or mitigating to the extent according to the following classifications
1) If the exclusive area per household exceeds 60 square meters, the installation standards shall be strengthened by one-fifth or relaxed by one-half.
2) In cases where the exclusive area per household is 60 square meters or less, the installation standards may be strengthened by half or relaxed by seven-tenths.
3. Delete<2024.4.16>
② When calculating the total number of parking unit spaces (referring to parking unit spaces under the "Parking Lot Act"; hereinafter the same applies) that must be installed in accordance with Paragraph 1, if a portion of the parking lot installed in an urban residential building is used for the support of shared use of passenger cars pursuant to Article 33, Paragraph 1, Subparagraph 4 of the "Urban Traffic Management Promotion Act" (referring to the installation of dedicated parking spaces for shared use of passenger cars and the permanent placement of passenger cars for shared use; hereinafter the same applies), it shall be deemed that parking unit spaces corresponding to 3.5 times the number of parking unit spaces installed for the support of shared use of passenger cars (decimal places shall be discarded) have been installed. However, if it is necessary to secure a certain proportion or more of parking units not intended for supporting the shared use of passenger cars among the total number of parking units to be installed pursuant to Paragraph 1, the mandatory installation ratio of said parking units may be determined by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province (referring to a Special Self-Governing Province without any local government entities such as Cities or Counties within its jurisdiction), City, County, or Autonomous District, taking into consideration regional vehicle ownership rates, etc., within the range of ratios classified in each of the following subparagraphs. <Newly added 2024.4.16>
1. In the case of semi-residential or commercial areas: Within 40% of the total number of parking units
2. In the case of urban areas other than those specified in Item 1: Within 70% of the total number of parking units
③ Parking lots pursuant to each subparagraph of Paragraph 1 and Paragraph 2 may be designated by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province (referring to a Special Self-Governing Province without a local government city or county within its jurisdiction), City, or County to be installed as dedicated parking spaces for electric vehicles in part, taking into consideration regional characteristics, the degree of distribution of electric vehicles (referring to electric vehicles as defined in subparagraph 3 of Article 2 of the Act on Promotion of Development and Dissemination of Environmentally Friendly Vehicles), and the size of housing. <Newly added 2016.6.8, 2023.12.5, 2024.4.16>
④ For facilities other than housing (including ancillary facilities and community facilities) constructed in a housing complex, ancillary parking lots calculated in accordance with the "Parking Lot Act" shall be installed. <Amended June 30, 2005, Apr 16, 2024>
⑤ Notwithstanding Paragraph 1, Subparagraph 2 and Paragraph 2, if an urban-type residential building meets all the requirements of the following subparagraphs, the installation standards for attached parking lots under Article 19 of the Parking Lot Act may be applied based on the use prior to the change of use during the period of use as a rental housing. <Newly added 2021.1.12, 2022.2.11, 2023.12.5, 2024.4.16, 2025.1.21>
1. Meet the requirements of each subparagraph of Article 7, Paragraph 11
2. Additional parking lots must be installed in accordance with Paragraph 1, Subparagraph 2 and Paragraph 2
3. The exclusive area per household shall be less than 30 square meters
4. Lease with the lessee not owning a vehicle during the lease period (excluding vehicles issued a vehicle registration sticker for use by persons with disabilities pursuant to Article 39, Paragraph 2 of the Welfare Act for Persons with Disabilities).
6. In the case of constructing welfare housing for the elderly pursuant to the "Elderly Welfare Act," notwithstanding the provisions of Paragraph 1, the number of parking spaces per household in the said housing complex shall be at least 0.3 (0.2 if the exclusive area per household is 60 square meters or less). <Newly added Aug. 27, 1998; Jun. 30, 2005; Jan. 12, 2021; Apr. 16, 2024>
7. In the case of public housing under Article 2 of the Special Act on Public Housing (hereinafter referred to as "public housing utilizing railway sites") constructed within a radius of 500 meters from a station facility among the railway facilities specified in Subparagraph 2 of Article 3 of the Framework Act on the Development of the Railway Industry, the parking facility installation standards under Paragraph 1 may be applied to the relevant housing complex with a relaxation of up to one-half. <Newly added 2009.11.5, 2014.4.29, 2015.12.28, 2021.1.12, 2024.4.16>
⑧ In addition to the matters prescribed in Paragraphs 1 through 7, matters necessary for the standards of the structure and facilities of parking lots shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Newly added Feb. 20, 1993; Dec. 23, 1994; Dec. 30, 1994; Aug. 27, 1998; Feb. 29, 2008; Mar. 23, 2013; Jan. 12, 2021; Apr. 16, 2024>
Article 28 (Management Office, etc.)
① In a housing complex constructing 50 or more multi-unit dwellings, all of the facilities specified in each of the following subparagraphs shall be installed, provided that the total area shall be at least 10 square meters plus 500 square centimeters for every household exceeding 50 households. However, if the total area exceeds 100 square meters, the installation area may be set at 100 square meters. <Amended 2020.1.7>
1. Management Office
2. Rest facilities for workers engaged in apartment complex management duties, such as security guards
② The management office under Paragraph 1, Subparagraph 1 shall be located in consideration of the efficiency of management operations and accessibility for residents. <Amended Jan. 7, 2020>
③ Rest facilities under Paragraph 1, Subparagraph 2 shall be installed in accordance with the Industrial Safety and Health Act. <Newly added 2020.1.7>
[Wholly Revised 2006.1.6]
[Title revised 2020.1.7]
Article 29 Deleted <2014.10.28>
Article 30 (Prevention of Flood Damage, etc.)
① Where a retaining wall or embankment (hereinafter referred to as "retaining wall, etc.") with a height of 2 meters or more exists or is to be installed in a housing complex (including the outer perimeter surrounding the complex boundary), the distance from said retaining wall, etc. to the outer perimeter of a building shall be set back by the height of said retaining wall, etc. However, this shall not apply in any of the following cases: <Amended Feb. 20, 1993>
1. A building whose foundation is lower than the foundation of a retaining wall, etc. In this case, the distance from the retaining wall, etc. to the outer part of the building must be at least 5 meters (3 meters for buildings of 3 stories or less).
2. Underground portions of buildings located on the side lower than retaining walls, etc., and building portions with a height of 1 meter or less from the ground
② Facilities necessary for the drainage of rainwater, such as drains, catch basins, and sumps (water storage tanks), must be installed in housing complexes. <Amended Jan. 5, 2021>
③ In cases where a housing complex is located in a low-lying area or other region at risk of flooding, water supply rooms, telephone exchange terminal boxes, and other similar electrical and telecommunication facilities installed within the housing complex shall be installed in a location that is not flooded as much as possible. <Newly added July 25, 1992>
④ In addition to the matters prescribed in Paragraphs 1 through 3, matters necessary for flood prevention, etc. shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Amended Jul. 25, 1992; Dec. 23, 1994; Dec. 30, 1994; Feb. 29, 2008; Mar. 23, 2013>
[Title Revised 2021.1.5]
Article 31 (Information Signs, etc.)
① Guide signs shall be installed in housing complexes constructing 300 or more housing units and in their surroundings in accordance with the standards of each of the following subparagraphs. However, the sign referred to in subparagraph 2 may not be installed if there is a road sign, etc., displaying the relevant information. <Amended Dec. 23, 1994; Dec. 30, 1994; Feb. 29, 2008; Mar. 23, 2013; Oct. 28, 2014>
1. Delete<2014.10.28>
2. Install a complex entrance sign displaying the name of the complex along the access road to the complex.
3. Install a comprehensive complex information board at each major entrance of the complex, indicating the layout of buildings, roads, and other major facilities within the complex.
4. Delete <2014.10.28>
② If a housing complex consists of two or more multi-unit dwelling buildings, the building number must be displayed in a conspicuous place on the exterior wall of each building.
③ A bulletin board for notifying residents of announcements shall be installed at or near the management office.
④ Delete <2014.10.28>
Article 32 (Communication Facilities)
① In residential buildings, in-building telecommunications line facilities shall be installed up to the telephone installation location (referring to the living room or bedroom) for each household; provided, matters necessary for the installation of in-building telecommunications line facilities shall be prescribed separately by Presidential Decree. <Amended Dec. 30, 1994; Feb. 29, 2008>
② Each household in a multi-unit dwelling equipped with a security office shall be equipped with an internal telephone capable of communicating with the security office.
③ In residential buildings, in-house telecommunications line facilities capable of ultra-high-speed information and communication shall be installed in each household. <Newly added Apr. 30, 2001>
Article 32-2 (Intelligent Home Network Facilities) In the case of installing intelligent home network facilities (referring to facilities that provide integrated residential services through the mutual linkage of intelligent information and communication systems and home appliances, etc., within a household or housing complex to improve the performance of the housing and the quality of residence), such facilities shall comply with the installation and technical standards for intelligent home network facilities jointly notified by the Minister of Land, Infrastructure and Transport, the Minister of Trade, Industry and Energy, and the Minister of Science and ICT through consultation. <Amended Mar. 23, 2013; Jul. 26, 2017; Oct. 1, 2025>
[This Article Newly Established 2008.11.11]
Article 33 (Security Lights)
① Security lights shall be installed in children's playgrounds and on roads within a housing complex (on both sides of the road in the case of roads with a width of 15 meters or more). In this case, the spacing between security lights installed on the said road shall be within 50 meters. <Amended Aug. 27, 1998>
② Security lights pursuant to the provisions of Paragraph 1 shall be equipped with a device that automatically turns on and off according to external brightness or a device that adjusts the time.
Article 34 (Gas Supply Facilities)
① When constructing housing in an area where city gas can be supplied, or when constructing housing supplied with liquefied petroleum gas via pipeline, gas supply facilities must be installed up to each household; in other areas, facilities for storing liquefied petroleum gas containers must be installed in a location facing the outside air to ensure safety.
② Notwithstanding Paragraph 1, gas supply facilities may not be installed up to each household if all of the requirements of the following subparagraphs are met. <Newly added 2018.12.31, 2021.1.12>
1. Must be long-term public rental housing
2. The exclusive area per household shall be 50 square meters or less
3. Gas facilities must not be installed within the household, and electric cooking facilities must be installed.
4. Building facilities for heating pursuant to Article 87, Paragraph 2 of the Enforcement Decree of the Building Act shall not be installed using an individual heating method.
③ The Mayor of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province, or Provincial Governor (hereinafter referred to as "City/Provincial Governor") may require the installation of gas storage facilities in housing complexes constructing 500 or more housing units in accordance with the gas supply plan for the relevant area. <Amended June 8, 1996; October 19, 2009; October 28, 2014; December 31, 2018>
Article 35 (Emergency Water Supply Facilities)
① In a housing complex where multi-unit housing is being constructed, underground pumping facilities or underground water storage facilities capable of supplying emergency water that meets the drinking water quality standards under Article 5 of the Drinking Water Management Act shall be installed. <Amended Sep. 29, 1999; Jun. 30, 2005>
② Underground pumping facilities and underground water tanks pursuant to Paragraph 1 shall meet the installation standards set forth in each of the following subparagraphs. However, in the case of housing complexes constructing public housing utilizing railway sites, the standards for City and County areas shall apply. <Amended 2009.11.5, 2012.6.29, 2014.4.29, 2014.10.28>
1. Underground Pumping Facility
a. Capable of pumping a quantity of at least 0.2 tons (0.1 tons in city/county areas) per household in the relevant housing complex per day.
B. Install an emergency power supply necessary for pumping and a pump capable of operating by it.
C. An underground water storage tank capable of storing at least 0.3 tons per household shall be installed together with the relevant pumping facility (it must comply with the standards under Article 43, Paragraph 6).
2. Underground water tank
A. It shall be capable of storing a water volume of at least 0.5 tons per household (0.25 tons for single-person housing), including the elevated water tank storage capacity (included up to 0.25 tons per household). However, considering regional water supply facility capacity and tap water usage per household, the requirements may be relaxed or strengthened by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province, City, or County within the range of one-half of the installation standards.
B. Install at least one manual pump per 50 households (100 households for single-person housing), or install an emergency power supply necessary for water pumping and a pump capable of being operated by it.
C. Install in accordance with the standards under Article 43, Paragraph 6.
D. Install so that drinking water can be supplied to each household through the relevant water reservoir.
[Wholly Revised 1998.8.27]
Article 36 Deleted <1999.9.29>
Article 37 (Heating Facilities, etc.)
① Heating facilities for multi-unit dwellings with six or more stories shall be of the central heating system (including the district heating supply system under the Collective Energy Business Act; hereinafter the same applies). However, this shall not apply in cases where heating facilities are installed pursuant to the provisions of Article 87, Paragraph 2 of the Enforcement Decree of the Building Act. <Amended May 30, 1992; February 20, 1993; September 29, 1999; June 30, 2005>
② In cases where the heating system of a multi-unit dwelling is a central heating system, heating pipes must be installed separately for each heating zone to ensure that heating heat is supplied evenly to each household. For buildings of 4 stories or more and 10 stories or less, the building must be divided into at least two heating zones, and for buildings exceeding 10 stories, one additional zone must be added for every 5 stories exceeding 10 stories. However, this shall not apply in cases falling under any of the following subparagraphs. <Amended 1993.2.20, 1994.12.30, 1998.8.27, 2005.6.30, 2008.2.29, 2013.3.23, 2025.10.1>
1. In cases where facilities or equipment are installed that are recognized by investigations or tests by research institutions or academic organizations as being capable of supplying heating energy equally to each household
2. In cases where the heating facility operates under the district heating supply method pursuant to the Collective Energy Business Act, and a flow control device is installed for each household in accordance with the regulations set by the Minister of Climate, Energy and Environment
③ In each household of a multi-unit dwelling equipped with a central heating system, a meter for measuring heating heat quantity and a device for controlling heating temperature shall be installed, respectively, in accordance with the regulations prescribed by the Minister of Climate, Energy and Environment. <Amended 1993.3.6, 1994.12.30, 1996.6.8, 1998.8.27, 2008.2.29, 2009.10.19, 2013.3.23, 2025.10.1>
④ In cases where ondol-type heating facilities are installed in each household of a multi-unit dwelling pursuant to Article 87, Paragraph 2 of the Enforcement Decree of the Building Act, heating facilities must also be installed in walk-in closets included in bedrooms or spaces for installing built-in furniture. <Newly Added 2016.10.25>
⑤ Each household in a multi-unit dwelling shall be provided with a space, such as a balcony, within the household where an exhaust device for air conditioning equipment can be installed. However, this shall not apply in the case of a centralized air conditioning system. <Newly added Jan. 6, 2006, Oct. 25, 2016>
6. The installation space for the exhaust device pursuant to the main text of Paragraph 5 shall be installed in accordance with the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport so that the exhaust device of the cooling equipment can operate smoothly. <Amended Jan. 7, 2020>
[Title Revised 2006.1.6]
Article 38 (Waste Storage Facilities) Household waste storage facilities or containers shall be installed in housing complexes, and the installation site shall be a place where vehicle access is possible and convenient for use by residents. <Amended Dec. 30, 1994; Jun. 8, 1996; Sep. 29, 1999>
[Wholly Revised 1992.7.25]
Article 39 (Installation of Image Information Processing Devices) In housing complexes constructing multi-unit housing subject to subparagraphs (a) through (d) of Article 2, Paragraph 1, Subparagraph 2 of the "Act on the Management of Multi-Unit Housing," image information processing devices pursuant to Article 3, Paragraph 1, Subparagraph 1 or 2 of the "Enforcement Decree of the Personal Information Protection Act" shall be installed for security and crime prevention purposes in accordance with the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Amended Mar. 23, 2013; Oct. 17, 2017; Dec. 31, 2018; Sep. 12, 2023; Jan. 2, 2024>
[This Article Newly Established 2011.1.4]
[Title Revised 2018.12.31]
Article 40 (Electrical Facilities)
① The capacity of electrical facilities installed in a dwelling shall be at least 3 kilowatts per household (in cases where the exclusive area per household is 60 square meters or more, the value obtained by adding 0.5 kilowatts for every 10 square meters exceeding 60 square meters to 3 kilowatts). <Amended Aug. 27, 1998>
② In residential buildings, an electricity meter for measuring the electricity consumption of each household shall be installed in a location outside the exclusive area of each household where meter reading is easy. However, if a remote metering system that automatically measures electricity consumption is applied, the electricity meter may be installed inside the exclusive area of each household. <Amended Jul. 25, 1992>
③ Electric wires installed outdoors within a housing complex shall be buried underground. However, in a complex where housing units with an exclusive area of 60 square meters or less constitute at least half of the total number of households, electric wires installed on roads with a width of 8 meters or more may be overhead lines.
④ Delete <1999.9.29>
⑤ Except for the matters prescribed in Paragraphs 1 through 3, Article 67 of the Electric Power Business Act shall apply mutatis mutandis to the installation and technical standards of electrical facilities. <Amended May 30, 1992; Sep. 29, 1999; Feb. 24, 2001; Jun. 30, 2005>
Article 41 Deleted <2014.10.28>
Article 42 (Installation of Common Reception Facilities for Broadcast Reception, etc.)
① Delete <2017.10.17>
② Each household in a multi-unit dwelling shall be equipped with at least two terminals connected to receiving antennas for terrestrial television broadcasting, FM radio broadcasting, and satellite broadcasting among the shared broadcasting reception facilities installed pursuant to the proviso to Paragraph 4 and Paragraph 5 of Article 87 of the Enforcement Decree of the Building Act. However, in the case of dwellings with an exclusive area of 60 square meters or less per household, one terminal may be installed. <Amended Jan. 6, 2006, Oct. 17, 2017>
[Title Revised 2006.1.6]
Article 43 (Water Supply and Drainage Facilities)
① Piping for water supply and drainage installed in a dwelling shall not be buried within a concrete structure. However, this shall not apply in any of the following cases: <Amended Jul. 25, 1992; Feb. 20, 1993; Oct. 28, 2014; Jan. 17, 2017>
1. Where water supply and drainage pipes penetrate the floor or wall surface, etc. of a dwelling at a right angle
2. In cases where piping is installed by pre-burying cover pipes within the concrete structure to the extent that the structural safety of the house is not compromised
3. Cases where the project plan approval authority acknowledges that the burial of piping is unavoidable due to the form of the concrete structure, etc., and the piping is installed in a manner that prevents corrosion and facilitates repair and replacement.
② Water supply and drainage piping installed in bathrooms of residential buildings shall comply with the standards of each of the following subparagraphs. <Newly added 2017.1.17, 2021.1.5, 2021.1.12>
1. Install pressure-regulating devices, such as pressure reducing valves, in the water supply piping to ensure that the water pressure for each household is maintained at a constant level.
2. Drainage piping may be installed using the floor-top piping method (referring to a method of installing pipes above the floor slab of the relevant floor) or the floor-under-floor piping method (referring to a method of installing pipes below the floor slab and exposing them to the ceiling of the unit on the lower floor). In the case of installation using the floor-under-floor piping method, low-noise pipes with a noise insulation performance of at least 5 decibels higher under the same measurement conditions than when installing general-purpose rigid (hard material) PVC pipes shall be used.
③ In multi-unit dwellings, water meters for each household and at least two water taps for each household shall be installed. <Amended Feb. 20, 1993>
4. Drainage facilities shall be installed on the floors of balconies and areas where water is used, such as kitchens, bathrooms, toilets, and utility rooms in residential buildings. However, this shall not apply to balconies where water supply facilities are not installed. <Amended Feb. 20, 1993; Aug. 27, 1998; Jan. 7, 2009; Oct. 28, 2014>
⑤ The drainage facilities pursuant to the provisions of Paragraph 4 shall be equipped with facilities capable of preventing odors and backflow of drainage. <Amended Feb. 20, 1993>
⑥ Water supply tanks and reservoirs for drinking water installed in residential buildings shall comply with the standards of each of the following subparagraphs. <Newly added 1992.7.25, 1993.2.20, 2021.1.5>
1. The materials used for water supply tanks and reservoirs shall be durable materials that do not contaminate water quality or pose no risk to hygiene, and have undergone plating, rust prevention treatment, or coating treatment.
2. The structure of water supply tanks and reservoirs shall be easy to maintain, such as for cleaning, and shall prevent substances other than drinking water from entering.
7. In addition to the matters prescribed in Paragraphs 1 through 6, standards regarding the installation and structure of water supply, drainage, gas supply, and other piping facilities shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport. <Amended 1992.7.25, 1993.2.20, 1994.12.23, 1994.12.30, 2008.2.29, 2013.3.23, 2014.10.28, 2017.1.17>
Article 44 (Exhaust Facilities, etc.)
① In the kitchen, bathroom, and toilet of a dwelling, windows facing the outside air shall be installed, or exhaust facilities shall be installed in accordance with the Ordinance prescribed by the Ministry of Land, Infrastructure and Transport. <Amended Feb. 29, 2008, Mar. 23, 2013>
② In cases where a sealed walk-in closet or built-in furniture is installed in the bedroom of each household in a multi-unit dwelling, exhaust facilities or ventilation openings pursuant to Paragraph 1 must be installed in said closet or built-in furniture. However, exhaust facilities or ventilation openings may not be installed in closets or built-in furniture installed away from the exterior wall and bathroom. <Newly added 2016.10.25, 2021.1.5>
③ The installation standards, etc. for ventilation facilities installed in each household of multi-unit housing pursuant to Article 40 of the Act shall be as prescribed by the Building Act and related regulations. <Amended Aug. 11, 2016, Oct. 25, 2016>
[Wholly Revised 2006.1.6]
Article 45 Deleted <1998.8.27>
Chapter 5 Welfare Facilities
Article 46 Deleted <2013.6.17>
Article 47 Deleted <2013.6.17>
Article 48 Deleted <1998.8.27>
Deleted <1994.12.30>
Article 50 (Neighborhood Living Facilities, etc.)
① Delete <2014.10.28>
② Delete <1993.9.27>
③ Delete <1993.9.27>
④ If the combined area of neighborhood living facilities and retail markets/shops installed in a single building (referring to the area used exclusively; if there are two or more facilities of the same use, it shall be the sum of the floor areas of each facility) exceeds 1,000 square meters, an open space necessary for parking or loading/unloading goods, etc., must be installed, and in the surrounding area, measures such as blocking noise and odors, planting for landscaping, and other necessary steps must be taken. <Amended Sep. 27, 1993; Dec. 30, 1994; Sep. 29, 1999; Oct. 28, 2014>
[Title Revised 1999.9.29]
Delete Article 51 <1993.9.27>
Article 52 (Kindergarten)
① In a housing complex constructing 2,000 or more housing units, land suitable for the installation of a kindergarten must be secured and either sold to those wishing to install the facility for construction or supplied to those intending to construct and operate a kindergarten. However, this shall not apply in any of the following cases: <Amended 2003.11.29, 2005.6.30, 2009.10.19, 2017.2.3, 2024.1.2>
1. If there is a kindergarten within a walking distance of 300 meters from the relevant housing complex
2. Where facilities specified in each subparagraph of Article 9 of the “Act on the Protection of Educational Environment” are located within a walking distance of 200 meters from the relevant housing complex
3. Delete<2013.6.17>
4. Where the project plan approval authority recognizes that the installation of a kindergarten is unnecessary because the relevant housing complex is a senior housing complex, a foreigner housing complex, etc.
5. Where the competent Superintendent of Education recognizes that the establishment of a kindergarten within the relevant housing complex is not in accordance with the child placement plan pursuant to Article 8, Paragraph 3, Subparagraph 2 of the Early Childhood Education Act
② In cases where a kindergarten is constructed in combination with facilities for purposes other than a kindergarten, medical facilities, community exercise facilities, daycare centers, religious assembly halls, and neighborhood living facilities (limited to facilities that may be installed in an educational environment protection zone pursuant to Article 8 of the Act on the Protection of the Educational Environment) may be installed together. In this case, the total floor area for kindergarten use must be at least one-half of the total floor area of the building. <Amended 2005.6.30, 2011.12.8, 2017.2.3>
③ Complex buildings pursuant to Paragraph 2 shall be structured so that the entrances, stairs, corridors, and restrooms of kindergartens are separated from facilities for other uses (excluding daycare centers and social welfare centers under Article 2, Subparagraph 5 of the Social Welfare Services Act) in order to protect the environment for early childhood education and care. <Amended Dec. 8, 2011; Oct. 17, 2017>
[Wholly Revised 1999.9.29]
Article 53 Deleted <2013.6.17>
Delete Article 54 <1999.9.29>
Article 55 Deleted <2013.6.17>
Article 55-2 (Community Facilities for Residents)
① In a housing complex constructing 100 or more housing units, community facilities for residents shall be installed with an area equal to or greater than that calculated in accordance with each of the following subparagraphs. However, considering regional characteristics, housing types, etc., the installation area of community facilities for residents may be determined by ordinance of a Special City, Metropolitan City, Special Self-Governing City, Special Self-Governing Province, City, or County by strengthening or relaxing the standard within one-quarter of the specified amount. <Amended 2014.10.28>
1. 100 households or more but less than 1,000 households: Area plus 2.5 square meters per household
2. 1,000 households or more: Area calculated by adding 2 square meters per household to 500 square meters
② The area under Paragraph 1 shall be calculated as the sum of the areas used exclusively for each facility. However, in the case of facilities installed outdoors, it shall be the site area where the facility is installed.
③ In the case of installing community facilities for residents pursuant to Paragraph 1, the relevant housing complex shall include facilities classified according to each of the following subparagraphs. <Amended Jan. 12, 2021, Jun. 30, 2026>
1. 150 households or more: Senior citizen center, children's playground
2. 300 households or more: Senior citizen center, children's playground, daycare center
3. 500 or more households: Senior citizen centers, children's playgrounds, daycare centers, resident exercise facilities, small libraries, community childcare centers
④ Notwithstanding Paragraph 3, the facilities listed in each of the following subparagraphs may not be installed. <Newly added 2026.6.30, 2026.9.8>
1. Facilities that the project plan approval authority deems unnecessary to install, considering the characteristics of the relevant housing complex, the current status of facility installation in the neighboring area, etc.
2. Small libraries in any of the following cases
a. Where a public library pursuant to Article 4, Paragraph 2, Subparagraph 1 of the Library Act (excluding small libraries; hereinafter the same applies in this Article) is installed within a horizontal distance of 300 meters from the boundary of the housing complex
B. Where the installation of a public library pursuant to Article 4, Paragraph 2, Subparagraph 1 of the Library Act is planned within the housing complex
3. The Together Care Center that a majority of prospective residents oppose in writing
4. Facilities identical or similar to those specified in each subparagraph of Paragraph 3, which the project plan approval authority deems unnecessary to install, as such facilities are installed within a horizontal distance of 300 meters from the boundary of the urban-type residential building.
⑤ The types of community facilities for residents per household that must be installed in accordance with the number of households, in addition to the facilities prescribed in Paragraph 3, may be separately determined by ordinance in consideration of regional conditions, etc., of Special Cities, Metropolitan Cities, Special Self-Governing Cities, Special Self-Governing Provinces, Cities, or Counties. <Amended Oct. 28, 2014, Jun. 30, 2026>
⑥ The Minister of Land, Infrastructure and Transport may, in consultation with the Minister of Culture, Sports and Tourism and the Minister of Health and Welfare, determine matters concerning the detailed area for each community facility for residents pursuant to each subparagraph of Paragraph 3 and provide such information to Special Cities, Metropolitan Cities, Special Self-Governing Cities, Special Self-Governing Provinces, Cities, or Counties for their utilization. <Amended Oct. 28, 2014, Jun. 30, 2026>
7. Detailed area standards for each type of community facility for residents that must be mandatorily installed pursuant to Paragraphs 3 and 5 may be determined by ordinance in consideration of regional conditions, etc., of Special Cities, Metropolitan Cities, Special Self-Governing Cities, Special Self-Governing Provinces, Cities, or Counties. <Amended Oct. 28, 2014, Jun. 30, 2026>
⑧ Community facilities for residents pursuant to each subparagraph of Paragraph 3 shall be installed in accordance with the standards of each of the following subparagraphs. <Amended 2015.5.6, 2021.1.12, 2022.12.6, 2026.6.30>
1. Senior Citizens' Center
A. Install in a location with good sunlight and natural lighting
B. Secure a shared multi-purpose room for recreation, hobbies, work, etc., and separate spaces for men and women.
C. Install water supply facilities, cooking facilities, restrooms, and ancillary gardens.
2. Children's Playground
A. Playground equipment and other necessary equipment shall be installed in a location with good sunlight and natural lighting, or installed to harmonize with the green spaces of the housing complex.
B. In the case of indoor installation, finishing materials, adhesives, and other interior materials used in playground equipment, etc., shall be eco-friendly materials that have obtained certification for the Environmental Label pursuant to Article 17 of the Environmental Technology and Environmental Industry Support Act or meet equivalent standards.
C. When installed outdoors, it shall be installed at a distance of at least 3 meters from the adjacent site boundary (in cases where it abuts a road, plaza, facility green space, or other open space where construction is not permitted, it refers to the boundary on the opposite side) and from roads and parking lots within the housing complex.
3. Daycare Center
A. It shall be installed in accordance with the standards of the "Infant and Toddler Childcare Act".
B. Install by the time of the final inspection of the relevant dwelling.
4. Residents' Exercise Facilities
A. Facilities shall be installed to prevent safety accidents.
B. When installing sports facilities specified in Annex 1 of the Enforcement Decree of the Act on the Installation and Use of Sports Facilities, they shall comply with the facility standards of the competition rules for each relevant sport.
5. Small libraries shall be installed in accordance with the standards of Item 1, Subparagraph (b) and Item 2, Subparagraph (b) of Annex 6 of the Enforcement Decree of the Library Act.
6. The Community Care Center shall be established in accordance with the standards of Article 44-2, Paragraph 5 of the Child Welfare Act.
[This Article Newly Established 2013.6.17]
Chapter 6 The Formation of the Land
Article 56 (Safety of Site)
① When preparing a building site, necessary measures shall be taken to prevent ground collapse, soil erosion, etc.
② Except for matters prescribed in this Decree regarding the creation of building sites pursuant to the provisions of Paragraph 1, Article 40 and Article 41, Paragraph 1 of the Building Act shall apply mutatis mutandis. <Amended May 30, 1992; June 30, 2005; October 29, 2008>
Article 57 (Trunk Facilities) On a parcel of land developed upon obtaining approval of a project plan pursuant to Article 15 of the Act, access roads (including trunk roads adjoining the said land), water and sewage facilities, and electrical facilities meeting or exceeding the standards prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport shall be installed. <Amended Dec. 23, 1994; Dec. 30, 1994; Nov. 29, 2003; Feb. 29, 2008; Mar. 23, 2013; Aug. 11, 2016>
Chapter 7 Recognition of Performance Grades for Floor Impact Sound Insulation Structures in Multi-Unit Housing, etc. <Amended June 27, 2014>
Article 58 (Display of Performance Grade of Multi-unit Housing) In the part other than the subparagraphs of Article 39 of the Act, the term "number of units prescribed by Presidential Decree" refers to 500 households. <Amended Aug. 11, 2016; Dec. 31, 2018>
[This Article Newly Established 2014.6.27]
Delete Article 59 <2013.2.20>
Article 59-2 Deleted <2013.2.20>
Delete Article 60 <2013.2.20>
Article 60-2 (Accreditation Agency for Floor Impact Sound Performance Grades)
① Any person who intends to be designated as an institution accredited for floor impact sound performance grades pursuant to Article 41, Paragraph 1 of the Act (hereinafter referred to as the "Floor Impact Sound Performance Grade Accredited Institution") shall submit to the Minister of Land, Infrastructure and Transport an application prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the documents set forth in each of the following subparagraphs. In this case, the Minister of Land, Infrastructure and Transport shall verify the certificate of corporate registration through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act. <Amended 2010.11.2, 2013.3.23, 2016.8.11, 2022.8.4>
1. List of Executives
2. Delete<2010.11.2>
3. Documents proving the personnel and equipment standards pursuant to Paragraph 2
4. Implementation Plan for Floor Impact Sound Performance Grade Certification Work
② The personnel and equipment standards for floor impact sound performance grading agencies are as set forth in Attached Table 6. <Amended Aug. 4, 2022>
③ In addition to the matters prescribed in Paragraphs 1 and 2, matters necessary for the designation of floor impact sound performance grading agencies shall be determined and announced by the Minister of Land, Infrastructure and Transport. <Amended Mar. 23, 2013, Aug. 4, 2022>
[This Article Newly Established 2008.9.25]
[Moved from Article 60-3, former Article 60-2 moved to Article 60-3 <2013.5.6>]
Article 60-3 (Floor Impact Sound Performance Grades and Standards, etc.)
① The Minister of Land, Infrastructure and Transport shall determine and publicly announce the floor impact sound performance grades and standards recognized by the floor impact sound performance grade recognition agency pursuant to Article 41, Paragraph 1 of the Act. <Amended Aug. 11, 2016, Aug. 4, 2022>
② Any person who intends to obtain recognition for floor impact sound insulation performance pursuant to the main text of the part other than each item of Subparagraph 2 of Article 14-2 shall obtain recognition for floor impact sound insulation performance from a floor impact sound performance grading agency in accordance with the methods and procedures, etc. prescribed and notified by the Minister of Land, Infrastructure and Transport. <Amended Aug. 4, 2022>
③ Delete <2022.8.4>
[Wholly Revised 2013.5.6]
[Moved from Article 60-2, former Article 60-3 moved to Article 60-2 <2013.5.6>]
Article 60-4 (Recognition of Performance Grades for New Products) Notwithstanding Article 60-3, Paragraph 1, when there is an application for recognition of a performance grade for a newly developed product or a product other than the recognized specifications (hereinafter referred to as "new product") to which the standards notified pursuant to Article 60-3, Paragraph 1 are difficult to apply, the Floor Impact Sound Performance Grade Recognition Agency may recognize a performance grade by establishing separate recognition standards for the new product pursuant to Article 60-5. <Amended May 6, 2013, Aug. 4, 2022>
1. Delete<2013.5.6>
2. Delete<2013.5.6>
[This Article Newly Established 2011.1.4]
Article 60-5 (Procedure for Recognition of Performance Grades for New Products)
① In order to establish separate performance grade recognition standards pursuant to Article 60-4, an agency accredited for floor impact sound performance grades shall undergo deliberation by the expert committee pursuant to Article 60-6 (hereinafter referred to as the "expert committee"). <Amended Aug. 4, 2022>
② The floor impact sound performance rating accrediting agency shall request a review by the expert committee within 15 days from the date of receiving an application for performance rating accrediting for a new product. <Amended Aug. 4, 2022>
③ The head of the Floor Impact Sound Performance Rating Accreditation Agency shall notify the applicant of the accreditation standards under Paragraph 1 without delay and make them known to the general public through the internet homepage, etc. <Amended Aug. 4, 2022>
④ The head of the floor impact sound performance grading accrediting agency shall submit separate performance grade grading standards pursuant to Paragraph 1 to the Minister of Land, Infrastructure and Transport, and the Minister of Land, Infrastructure and Transport shall publish them in the Official Gazette. <Amended Mar. 23, 2013, Aug. 4, 2022>
[This Article Newly Established 2011.1.4]
Article 60-6 (Specialized Committee)
① A specialized committee shall be established within the Floor Impact Sound Performance Rating Accreditation Agency to deliberate on matters concerning recognition standards, etc. for new products. <Amended Aug. 4, 2022>
② Specific matters necessary for the operation of the Committee, such as the composition of the Expert Committee, criteria for appointing members, and terms of office, shall be determined by the head of the relevant Floor Impact Sound Performance Rating Accreditation Agency. <Amended Aug. 4, 2022>
[This Article Newly Established 2011.1.4]
Article 60-7 (Validity Period, etc., of Performance Grade Recognition for Floor Impact Sound Insulation Structures in Multi-unit Housing)
① The validity period of the recognition of a performance grade for floor impact sound insulation structures in multi-unit housing pursuant to Article 41, Paragraph 3 of the Act shall be five years from the date of receiving such recognition. <Amended Aug. 11, 2016>
② A person who has received certification of a performance grade for a floor impact sound insulation structure for multi-unit housing may extend the validity period before the expiration of the validity period under Paragraph 1. In this case, the extended validity period shall not exceed three years for each extension.
③ The fee for the recognition of performance grades for floor impact sound insulation structures in multi-unit housing pursuant to Article 41, Paragraph 3 of the Act shall be the costs used for recognition work and testing, provided that additional costs inevitably associated with recognition work and testing may be added. <Amended Aug. 11, 2016>
④ In addition to the matters prescribed in Paragraphs 1 through 3, detailed matters necessary for the extension of the validity period of performance grade recognition for floor impact sound insulation structures in multi-unit housing, fees incurred for such recognition, etc., shall be determined and announced by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2013.12.4]
Article 60-8 (Thickness of Floor Structures Subject to the Relaxation of the Maximum Limit on Building Height) In Article 41, Paragraph 8 of the Act, the term "thickness prescribed by Presidential Decree" refers to a concrete slab thickness of 250 millimeters.
[New article established 2024.7.9]
[Formerly Article 60-8 moved to Article 60-9 <2024.7.9>]
Article 60-9 (Designation of Floor Impact Sound Performance Inspection Agencies)
① In Article 41-2, Paragraph 2 of the Act, the term "designation requirements prescribed by Presidential Decree" refers to the requirements of each of the following subparagraphs.
1. It must be a non-profit corporation pursuant to Article 32 of the Civil Act or a corporation established under a special act (excluding for-profit corporations).
2. Meet the personnel and equipment standards in accordance with Attached Table 6
3. Must not be a floor impact sound performance grading agency
② Any person who intends to be designated as a floor impact sound performance inspection agency pursuant to Article 41-2, Paragraph 2 of the Act (hereinafter referred to as the "floor impact sound performance inspection agency") shall submit to the Minister of Land, Infrastructure and Transport an application prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the documents specified in each of the following subparagraphs. In this case, the Minister of Land, Infrastructure and Transport shall verify the certificate of corporate registration through the joint use of administrative information pursuant to Article 36, Paragraph 1 of the Electronic Government Act.
1. Documents proving compliance with the personnel and equipment standards pursuant to Annex 6
2. Implementation Plan for Performance Inspection of Floor Impact Sound Insulation Structures Pursuant to Article 41-2, Paragraph 5 of the Act
③ When the Minister of Land, Infrastructure and Transport designates a floor impact sound performance inspection agency, he/she shall publish its name, representative, address, etc., in the Official Gazette.
④ In addition to the matters prescribed in Paragraphs 1 through 3, detailed matters necessary for the designation of floor impact sound performance inspection agencies shall be determined and announced by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2022.8.4]
[Moved from Article 60-8, former Article 60-9 moved to Article 60-10 <2024.7.9>]
Article 60-10 (Performance Inspection Method for Floor Impact Sound Insulation Structures, etc.)
① A project owner who intends to undergo a performance inspection of a floor impact sound insulation structure pursuant to Article 41-2, Paragraph 5 of the Act (hereinafter referred to as the "performance inspection") shall apply for the performance inspection to the head of the floor impact sound performance inspection agency after the construction of the floor impact sound insulation structure of the housing being constructed has been completed. <Amended July 9, 2024>
② The head of the floor impact sound performance inspection agency that has received an application pursuant to Paragraph 1 shall randomly select households to be inspected by unit, classified considering the floor plan type, area, and number of floors of each household, and conduct the performance inspection.
③ The head of the floor impact sound performance inspection agency shall notify the project owner of the results without delay upon completion of the performance inspection.
④ If requested by the project owner, the head of the floor impact sound performance inspection agency may, when notifying the results of the performance inspection pursuant to Paragraph 3, also notify the Mayor, County Governor, or District Head conducting the inspection for use pursuant to Article 49, Paragraph 1 of the Act (hereinafter referred to as the "authority for inspection for use" in this Article and Article 60-12). In this case, the project owner shall be deemed to have submitted the results of the performance inspection to the authority for inspection for use pursuant to Article 41-2, Paragraph 5 of the Act. <Amended 2024.7.9>
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, detailed matters necessary for performance inspection, such as the calculation ratio of the number of households subject to performance inspection, shall be determined and announced by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2022.8.4]
[Moved from Article 60-9, former Article 60-10 moved to Article 60-11 <2024.7.9>]
Article 60-11 (Performance Inspection Fee)
① The performance inspection fee shall be the cost incurred for the tests required for the performance inspection.
② The fee referred to in Paragraph 1 shall be calculated by the head of the floor impact sound performance inspection agency by applying the standards for remuneration for engineering projects pursuant to Article 31, Paragraph 2 of the Engineering Industry Promotion Act in accordance with the method prescribed and notified by the Minister of Land, Infrastructure and Transport.
[This Article Newly Established 2022.8.4]
[Moved from Article 60-10, former Article 60-11 moved to Article 60-12 <2024.7.9>]
Article 60-12 (Recommendation to the Project Owner)
① Pursuant to Article 41-2, Paragraph 6 of the Act, if the lightweight impact sound or heavyweight impact sound under the main text of the part other than each item of Subparagraph 2 of Article 14-2 exceeds 49 decibels, the inspection authority may recommend to the project owner measures such as remedial construction or compensation for damages. <Newly added 2024.7.9>
② When the inspection authority recommends measures such as supplementary construction to the project owner pursuant to Paragraph 1, it shall do so in the form of a document (including electronic documents) containing the matters of each of the following subparagraphs. <Amended 2024.7.9>
1. Content and Reasons for the Recommendation
2. Deadline for Action on Recommendations
③ A project entity that has received a recommendation pursuant to Paragraph 2 shall submit a plan of action regarding the recommended matters to the inspection authority within 10 days from the date of receiving the recommendation. However, in unavoidable cases, such as when technical review takes time, the period may be extended through consultation with the inspection authority. <Amended July 9, 2024>
④ In Article 41-2, Paragraph 7 of the Act, the phrase "period prescribed by Presidential Decree" refers to five days from the day following the expiration of the deadline for the measures under Paragraph 2, Subparagraph 2. <Amended July 9, 2024>
[This Article Newly Established 2022.8.4]
[Moved from Article 60-11 <2024.7.9>]
Article 60-13 (Notification of Performance Inspection Results, etc.) Pursuant to Article 41-2, Paragraph 8 of the Act, the Project Owner shall notify the prospective occupant of the results of each of the following subparagraphs in writing (including electronic documents) before the scheduled occupancy date.
1. Performance inspection results submitted to the inspection authority pursuant to Article 41-2, Paragraph 5 of the Act
2. Results of measures submitted to the inspection authority pursuant to Article 41-2, Paragraph 7 of the Act
[New article established 2024.7.9]
Article 60-14 (Selection and Disclosure of Contractors with Excellent Performance Inspection)
① Pursuant to Article 41-2, Paragraph 10 of the Act, a floor impact sound performance inspection agency may select the top 10 contractors as excellent contractors from among contractors who meet all the requirements of each of the following subparagraphs, based on the average value of performance inspection results for each housing complex that received a use inspection in the previous year (in cases where there is only one housing complex, it refers to the performance inspection result of that housing complex).
1. The total number of multi-unit housing units that received final inspection in the previous year must be 500 or more.
2. There shall be no housing complexes that fail to meet the performance inspection standards among the housing complexes that received the final inspection in the previous year
② If a floor impact sound performance inspection agency selects an excellent contractor pursuant to Paragraph 1, it shall disclose this information through the agency's website.
[New article established 2024.7.9]
Delete Article 61 <2022.8.4>
Chapter 8 Industrialized Housing <Revised Sep. 29, 1999>
Article 61-2 (Recognition of Industrialized Housing and Recognition of Changes)
① Any person who intends to obtain recognition for industrialized housing pursuant to Article 51, Paragraph 1 of the Act (hereinafter referred to as "industrialized housing") shall submit to the Minister of Land, Infrastructure and Transport an application for recognition of industrialized housing prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the documents set forth in each of the following subparagraphs.
1. Design and Product Specifications
2. Design Drawings, Fabrication Drawings, and Specifications
3. Test report on structure and performance or certificate of structural safety (only applicable if prepared by a Professional Engineer in the field of architectural structures who has confirmed that structural safety performance evaluation is possible)
4. Documents specifying production processes, construction processes, production capacity, and quality control plans
② The Minister of Land, Infrastructure and Transport shall notify the applicant of the approval or rejection of the application for recognition of industrialized housing within 60 days from the date of receipt of the application pursuant to Paragraph 1. However, if an extension of the processing period is necessary due to unavoidable reasons such as supplementation of documents, the processing period may be extended only once within a range of 10 days.
③ When the Minister of Land, Infrastructure and Transport recognizes industrialized housing, he/she shall issue an Industrialized Housing Recognition Certificate, prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, to the applicant and make public the relevant notice.
④ A person who has been issued a Certificate of Recognition for Industrialized Housing pursuant to Paragraph 3 shall, in the event that matters among the recognized matters prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport are changed, submit to the Minister of Land, Infrastructure and Transport an Application for Recognition of Change in Industrialized Housing prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the details of the change and documents capable of proving it. In this case, Paragraphs 2 and 3 shall apply mutatis mutandis to the notification of whether the change is recognized and the issuance of the modified Certificate of Recognition for Industrialized Housing.
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, matters necessary for the recognition and modification recognition of industrialized housing shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
[Wholly Revised 2026.5.6]
Article 61-3 (Validity Period of Recognition of Industrialized Housing and Extension Thereof)
① The validity period of the recognition of industrialized housing shall be five years from the date of public notice pursuant to Article 61-2, Paragraph 3, and may be extended for a period of three years.
② Any person who intends to extend the validity period of the recognition of industrialized housing pursuant to Paragraph 1 shall submit an application for extension of the validity period of the recognition of industrialized housing, as prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, to the Minister of Land, Infrastructure and Transport at least 60 days before the expiration of said validity period.
③ The Minister of Land, Infrastructure and Transport shall, at least 120 days before the expiration of the validity period of the recognition of industrialized housing, notify the person who has received such recognition of the procedures for extending the validity period and the fact that the validity period cannot be extended if an application is not submitted within the application period pursuant to Paragraph 2. In this case, notification may be made via text message using a mobile phone, e-mail, fax, telephone, document, etc.
④ The Minister of Land, Infrastructure and Transport shall notify the applicant of whether the validity period has been extended within 60 days from the date of receipt of the application for extension pursuant to Paragraph 2. However, if an extension of the processing period is necessary due to unavoidable reasons such as supplementation of documents, the processing period may be extended only once within a range of 10 days, and if the validity period of the Industrialized Housing Recognition expires during such extended processing period, the recognition shall be deemed to remain valid until notification of the extension is received.
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, matters necessary for the validity period of recognition of industrialized housing and its extension shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
[New article established 2026.5.6]
Article 61-4 (Post-certification management, etc. of industrialized housing)
① A person who has been issued a Certificate of Recognition for Industrialized Housing pursuant to Paragraphs 3 and 4 of Article 61-2 shall submit the production and construction performance records of industrialized housing to the Minister of Land, Infrastructure and Transport in accordance with the Ordinance prescribed by the Ministry of Land, Infrastructure and Transport.
② The Minister of Land, Infrastructure and Transport may conduct an inspection regarding the industrialized housing production capacity of a person who has been issued an industrialized housing certification pursuant to Article 61-2, Paragraphs 3 and 4, and whether the performance standards recognized as industrialized housing are satisfied.
③ A person constructing industrialized housing pursuant to Article 51, Paragraph 2 of the Act shall assign construction engineers to the construction site in accordance with Article 40 of the Framework Act on the Construction Industry.
④ In addition to the matters prescribed in Paragraphs 1 through 3, matters necessary for the post-management, etc., of the recognition of industrialized housing shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
[New article established 2026.5.6]
Article 62 Deleted <1999.9.29>
Deleted <1999.9.29>
Article 63 (Public Notice of Cancellation of Recognition) When the Minister of Land, Infrastructure and Transport cancels the recognition of industrialized housing pursuant to Article 52 of the Act, he/she shall publish such cancellation in the Official Gazette. <Amended Feb. 20, 1993; Dec. 23, 1994; Dec. 30, 1994; Sep. 29, 1999; Feb. 29, 2008; Oct. 19, 2009; Mar. 23, 2013; Aug. 11, 2016>
Chapter 9 Energy-Saving and Eco-Friendly Housing, etc. <Revised May 6, 2013>
Article 64 (Construction Standards, etc. for Energy-Saving and Eco-Friendly Housing)
① In the case of constructing multi-unit housing for which a project plan approval has been obtained pursuant to Article 15 of the Housing Act, it shall be constructed as energy-saving, eco-friendly housing (hereinafter referred to as "eco-friendly housing" in this Chapter) capable of reducing the total energy consumption or total carbon dioxide emissions of the housing by utilizing one or more of the technologies listed in each of the following subparagraphs. <Amended 2014.12.23, 2016.2.29, 2016.8.11>
1. Technologies for constructing low-energy buildings, such as high-insulation and high-performance envelope structures, airtight design, ensuring sunlight, and using eco-friendly materials
2. Energy-High Efficiency Equipment Technology, Including High-Efficiency Heat Source Equipment, Control Equipment, and High-Efficiency Ventilation Equipment
3. Technologies for utilizing new and renewable energy such as solar thermal, solar photovoltaic, geothermal, and wind power
4. Technology for creating external environments to secure ecological circulation functions such as the preservation of natural ground, securing ecological area ratio, and rainwater circulation
5. Technologies that maximize energy utilization efficiency, such as building energy informatization technology, automatic control devices, and intelligent power grids pursuant to Article 2, Subparagraph 2 of the "Act on the Promotion of Establishment and Use of Intelligent Power Grids"
② When a person intending to construct a house falling under Paragraph 1 applies for approval of a business plan pursuant to Article 15 of the Act, they shall submit an eco-friendly housing energy conservation plan. <Amended Dec. 23, 2014, Aug. 11, 2016>
③ Detailed matters necessary for the construction standards and energy conservation plans for eco-friendly housing shall be determined and announced by the Minister of Land, Infrastructure and Transport. <Amended Mar. 23, 2013; Dec. 23, 2014>
[This Article Newly Established 2009.10.19]
Delete Article 64-2 <2014.6.27>
Article 65 (Construction Standards for Health-Friendly Housing)
① When constructing multi-unit housing with 500 or more households, the housing shall be constructed as health-friendly housing capable of minimizing indoor air pollutants, etc. within households, in consideration of the matters in each of the following subparagraphs. <Amended Dec. 4, 2013>
1. Matters concerning the use of building materials (including built-in furniture and built-in home appliances) that emit fewer pollutants or suppress or reduce the generation of pollutants
2. Matters concerning construction management of finishing work to secure a clean indoor environment
3. Matters concerning the installation, performance verification, and maintenance of ventilation equipment for smooth indoor air ventilation
4. Matters concerning the implementation of ventilation supplying fresh outside air indoors using ventilation equipment, etc.
② Detailed matters necessary for the construction standards, etc. of health-friendly housing shall be determined and announced by the Minister of Land, Infrastructure and Transport. <Amended Dec. 4, 2013>
[This Article Newly Established 2013.5.6]
[Title Revised 2013.12.4]
Article 65-2 (Certification 대상 and Certification Grades, etc. of Long-Life Housing)
① The grades granted to long-life housing (hereinafter referred to as "long-life housing") pursuant to Paragraph 1 of Article 38, Paragraph 2 of the Act under the certification system shall be classified as follows: <Amended Aug. 11, 2016>
1. Top Grade
2. Excellent Grade
3. Good Grade
4. Standard Grade
② In Article 38, Paragraph 3 of the Act, the term "households prescribed by Presidential Decree" refers to 1,000 households. <Amended Aug. 11, 2016>
③ In Article 38, Paragraph 3 of the Act, the phrase "grade equal to or higher than the standards prescribed by Presidential Decree" refers to a grade equal to or higher than the general grade under Paragraph 1, Subparagraph 4. <Amended Aug. 11, 2016>
④ The certification body under Article 38, Paragraph 5 of the Act shall be a certification body designated pursuant to Article 16, Paragraph 2 of the Act on Support for the Creation of Green Buildings. <Amended Aug. 11, 2016>
⑤ Pursuant to Article 38, Paragraph 7 of the Act, the building coverage ratio and floor area ratio of long-life housing may be relaxed by ordinance according to the classifications in each of the following subparagraphs. <Amended Aug. 11, 2016, Jan. 17, 2017>
1. Building Coverage Ratio: Relaxed within a range not exceeding 115% of the building coverage ratio prescribed by ordinance pursuant to Article 77 of the National Land Planning and Utilization Act and Article 84, Paragraph 1 of the Enforcement Decree of the same Act. However, it shall not exceed the maximum limit of the building coverage ratio pursuant to Article 77 of the National Land Planning and Utilization Act.
2. Floor Area Ratio: Relaxed to the extent not exceeding 115% of the floor area ratio prescribed by ordinance pursuant to Article 78 of the National Land Planning and Utilization Act and Article 85, Paragraph 1 of the Enforcement Decree of the same Act. However, it shall not exceed the maximum limit of the floor area ratio pursuant to Article 78 of the National Land Planning and Utilization Act.
[This Article Newly Established 2014.12.23]
Article 66 (Review of Regulations)
① The Minister of Land, Infrastructure and Transport shall review the validity of the matters set forth in each of the following subparagraphs every three years based on the reference dates specified in each of the following subparagraphs (meaning until the day before the same date as the reference date of the year marking every third year) and take measures such as improvements. <Amended 2014.6.27, 2014.12.23, 2022.8.4, 2026.3.24>
1. Facilities within the complex pursuant to Article 6: January 1, 2014
2. Protection from noise, etc. pursuant to Article 9-2: January 1, 2014
3. Delete<2026.3.24>
4. Delete <2026.3.24>
5. Delete<2026.3.24>
6. Delete<2026.3.24>
7. Indication of Performance Grade of Multi-unit Housing Pursuant to Article 58: June 25, 2014
8. Housing subject to the Long-Life Housing Certification System pursuant to Article 65-2, Paragraph 1: December 25, 2014
② The Minister of Land, Infrastructure and Transport shall review the validity of the standards for lightweight impact sound and heavyweight impact sound pursuant to Subparagraph 2 of Article 14-2 every five years, starting from January 1, 2023 (meaning before January 1 of every fifth year), and take measures such as improvements. <Newly added Aug. 4, 2022>
[This Article Newly Established 2013.12.30]
Revision
The Partial Amendment to the Regulations on Housing Construction Standards, etc., which has been deliberated by the Cabinet, is hereby promulgated.
President Lee Jae-myung (Signature)
May 6, 2026
Prime Minister Kim Min-seok
Cabinet Member Minister of Land, Infrastructure and Transport Kim Yun-duk
Presidential Decree No. 36308
Partial Amendment to the Regulations on Housing Construction Standards, etc.
The Regulations on Housing Construction Standards, etc. are partially amended as follows.
Article 2, Subparagraph 3, Item (k) shall be as follows.
K. Shared kitchen and shared dining hall
In Article 14-2, Subparagraph 2, Item (a), "multi-unit housing (excluding industrialized housing recognized pursuant to Article 51, Paragraph 1 of the Act)" shall be changed to "multi-unit housing."
In the main text of Article 18, Paragraph 4, "on the railing" shall be changed to "on the railing or window frame," and in the proviso of the same paragraph, "railing" shall be changed to "user's safety and railings/window frames," and "may install" shall be changed to "shall install."
Article 61-2 shall be as follows.
Article 61-2 (Recognition of Industrialized Housing and Recognition of Modification) ① Any person who intends to obtain recognition of industrialized housing pursuant to Article 51, Paragraph 1 of the Act (hereinafter referred to as "industrialized housing") shall submit to the Minister of Land, Infrastructure and Transport an application for recognition of industrialized housing prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the documents set forth in each of the following subparagraphs.
1. Design and Product Specifications
2. Design Drawings, Fabrication Drawings, and Specifications
3. Test report on structure and performance or certificate of structural safety (only applicable if prepared by a Professional Engineer in the field of architectural structures who has confirmed that structural safety performance evaluation is possible)
4. Documents specifying production processes, construction processes, production capacity, and quality control plans
② The Minister of Land, Infrastructure and Transport shall notify the applicant of the approval or rejection of the application for recognition of industrialized housing within 60 days from the date of receipt of the application pursuant to Paragraph 1. However, if an extension of the processing period is necessary due to unavoidable reasons such as supplementation of documents, the processing period may be extended only once within a range of 10 days.
③ When the Minister of Land, Infrastructure and Transport recognizes industrialized housing, he/she shall issue an Industrialized Housing Recognition Certificate, prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, to the applicant and make public the relevant notice.
④ A person who has been issued a Certificate of Recognition for Industrialized Housing pursuant to Paragraph 3 shall, in the event that matters among the recognized matters prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport are changed, submit to the Minister of Land, Infrastructure and Transport an Application for Recognition of Change in Industrialized Housing prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, attaching the details of the change and documents capable of proving it. In this case, Paragraphs 2 and 3 shall apply mutatis mutandis to the notification of whether the change is recognized and the issuance of the modified Certificate of Recognition for Industrialized Housing.
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, matters necessary for the recognition and modification recognition of industrialized housing shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
Articles 61-3 and 61-4 are newly established as follows.
Article 61-3 (Validity Period of Recognition of Industrialized Housing and Extension thereof) ① The validity period of recognition of industrialized housing shall be five years from the date of public notice pursuant to Article 61-2, Paragraph 3, and may be extended for a period of three years.
② Any person who intends to extend the validity period of the recognition of industrialized housing pursuant to Paragraph 1 shall submit an application for extension of the validity period of the recognition of industrialized housing, as prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport, to the Minister of Land, Infrastructure and Transport at least 60 days before the expiration of said validity period.
③ The Minister of Land, Infrastructure and Transport shall, at least 120 days before the expiration of the validity period of the recognition of industrialized housing, notify the person who has received such recognition of the procedures for extending the validity period and the fact that the validity period cannot be extended if an application is not submitted within the application period pursuant to Paragraph 2. In this case, notification may be made via text message using a mobile phone, e-mail, fax, telephone, document, etc.
④ The Minister of Land, Infrastructure and Transport shall notify the applicant of whether the validity period has been extended within 60 days from the date of receipt of the application for extension pursuant to Paragraph 2. However, if an extension of the processing period is necessary due to unavoidable reasons such as supplementation of documents, the processing period may be extended only once within a range of 10 days, and if the validity period of the Industrialized Housing Recognition expires during such extended processing period, the recognition shall be deemed to remain valid until notification of the extension is received.
⑤ In addition to the matters prescribed in Paragraphs 1 through 4, matters necessary for the validity period of recognition of industrialized housing and its extension shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
Article 61-4 (Post-certification management, etc. of industrialized housing recognition) ① A person who has been issued an industrialized housing recognition certificate pursuant to Article 61-2, Paragraphs 3 and 4, shall submit production and construction performance records of industrialized housing to the Minister of Land, Infrastructure and Transport in accordance with the Ordinance prescribed by the Ministry of Land, Infrastructure and Transport.
② The Minister of Land, Infrastructure and Transport may conduct an inspection regarding the industrialized housing production capacity of a person who has been issued an industrialized housing certification pursuant to Article 61-2, Paragraphs 3 and 4, and whether the performance standards recognized as industrialized housing are satisfied.
③ A person constructing industrialized housing pursuant to Article 51, Paragraph 2 of the Act shall assign construction engineers to the construction site in accordance with Article 40 of the Framework Act on the Construction Industry.
④ In addition to the matters prescribed in Paragraphs 1 through 3, matters necessary for the post-management, etc., of the recognition of industrialized housing shall be prescribed by the Ordinance of the Ministry of Land, Infrastructure and Transport.
Supplementary Provisions
Article 1 (Enforcement Date) This Decree shall enter into force on the date of its promulgation. However, the amended provisions of Article 61-4, Paragraph 2 shall enter into force six months after the date of its promulgation.
Article 2 (Applicability to Standards for Floor Structures of Industrialized Housing) The amended provisions of Article 14-2, Subparagraph 2, Item (a) shall apply from the time an application for approval or approval of modification of a business plan is submitted pursuant to Article 15, Paragraphs 1, 3, or 4 of the Act following the enforcement of this Decree.
Reason for Enactment/Amendment
[Partial revision]
◇ Reason for Amendment
In order to create an age-friendly residential environment for multi-unit housing, a communal dining hall is added to the residents' community facilities, while...
This aims to improve and supplement certain shortcomings observed in the operation of the current system by relaxing construction standards for floor structures of industrialized housing*, extending the validity period of industrialized housing certification, and establishing grounds for post-certification inspections, in order to enhance the efficiency of housing supply by revitalizing the construction of industrialized housing, which boasts advantages such as short construction periods and excellent construction quality.
* Housing constructed using off-site construction methods, in which part or all of the main structural components of a building are prefabricated in a factory
◇ Key Contents
A. Expansion of the Scope of Community Facilities for Residents (Article 2, Subparagraph 3, Item k)
In addition to communal kitchens, which are facilities used jointly by residents of multi-unit housing or support their daily lives, communal dining halls are also added to the list of community facilities.
B. Relaxation of construction standards for floor structures of reinforced concrete frame multi-family housing recognized as industrialized housing (Article 14-2, Subparagraph 2, Item A)
Previously, only non-industrialized housing frame multi-unit dwellings were exempted from the mandatory requirement to use floor structures certified for impact sound insulation performance by an accredited performance rating agency; going forward, industrialized housing frame multi-unit dwellings will also be exempted from this obligation.
C. Improvement of the Industrialized Housing Recognition System (New Articles 61-2, 61-3, and 61-4)
1) If a person who has received recognition for industrialized housing intends to change part of the recognized details or extend the validity period (5 years), they shall apply to the Minister of Land, Infrastructure and Transport for the change of recognition or extension of the validity period, and the Minister of Land, Infrastructure and Transport shall notify the person of whether the change of recognition or the extension of the validity period will be granted within 60 days from the date of receiving the application.
2) The Minister of Land, Infrastructure and Transport may conduct inspections regarding the industrialized housing production capacity of a person who has been issued an Industrialized Housing Certificate and whether the performance standards recognized as industrialized housing are met.
<Provided by the Ministry of Government Legislation>