Annex 15 — 선박안전법 시행규칙
288417 · 2026-07-27
■ Enforcement Rules of the Ship Safety Act [Appendix 15-2] <Amended July 11, 2023>
Hull Thickness Measurement Range and Measurement Method (Related to Article 31-2, Paragraph 1)
1. Range of Thickness Measurement
a. Vessels aged 10 years or more but less than 20 years
For each section between the bow, engine room, and midship 0.4L, the hull main
Measure the plate thickness of the required member.
B. Vessels aged 20 years or more but less than 30 years
Regarding the 3rd section between the 1st section of the bow and engine room and 0.4L of the midship section, the hull
Measure the plate thickness of the main member.
. Vessels aged 30 years or older
Measure by adding one cross-section of the stern to the measurement range of item (b) above.
2. Thickness Measurement Method
a. A meeting attended by the ship inspector, the shipowner, and the thickness measurement company prior to conducting the thickness measurement
held a meeting regarding preparations for thickness measurement, the scope of thickness measurement, and the qualifications of thickness measurement personnel,
Determine the calibration and other details of the equipment, etc., including the following items:
prepared measurement meeting minutes (including cases where a ship inspector measures thickness)
.
1) Meeting Schedule and Attendees
2) Measurement Schedule, Conditions and Range
3) Soemohando
4) Communication system with inspectors, thickness measurement personnel, and shipowners
5) Documents to be provided by the thickness measurement business operator
6) Special Notes etc.
B. Thickness measurements must be taken at 10 points or more per cross-section, and the number of measurement points is line
It can be appropriately increased depending on the size of the vessel, the age of the vessel, and the degree of hull aging.
, at least 50/100 of the engine room length within the measurement range of 0.4L at the midship
overlaps, the engine area is considered to be contained within the 0.4L midship section.
. For oil tankers, bulk carriers, or bulk liquid dangerous goods carriers, in the cargo area
For all side plating between the ballast line and the full load line, in accordance with subparagraph (b)
Measure by adding at least 30/100 of the number of measurement points.
d. In cases where the measurement is conducted by a thickness measurement company, the ship inspector shall [review] the entire process of thickness measurement
Implement control and on-site monitoring, and at least 3% of the entire measurement process (longitudinal strength member
Must attend for at least 2/100 of other absences, or at least 1/100 of other absences. However, prior to this,
The scope of observation may be expanded if the inspector deems it necessary.
3. Soemohando
The wear limit of major hull members shall be in accordance with the following. However, in cases where the wear limit is exceeded,
This shall not apply if the measured thickness in is greater than or equal to the specified thickness.
┌────────────────────┬───────────────────┐
│PartName │Wear limit │
├────────────────────┼───────────────────┤
│1. Outer plating, heavy deck, heavy deck and side aft │20 percent of original thickness + 1 millimeter │
│Plate-shaped longitudinal member, bulkhead of deep tank │My │
│Plate, Inner Bottom Plate │ │
├────────────────────┼───────────────────┤
│2. Double bottom rib, girder, web of large aggregate and │Within 25 percent of original thickness │
│Flat material │ │
├────────────────────┼───────────────────┤
│3. Web face material and bracket of small aggregate, number │Within 30 percent of original thickness │
│Tight bulkhead plate, effective deck, hatch cover, hatch │ │
│Bo │ │
├────────────────────┼───────────────────┤
│4. Web and bracket of the internal rib │25 percent of original thickness or 2.5 millimeters │
│ │중 큰 값 이내 │
├────────────────────┴───────────────────┤
│Remarks │
│ 1. Small aggregate refers to an aggregate member that does not support other reinforcing materials. │
│ 2. The original thickness refers to the thickness on the drawing, and if the thickness on the drawing and the thickness of the vessel differ │
│, it refers to the thickness of the main line. │
└────────────────────────────────────────┘
4. Actions and recording of thickness measurement results, etc.
a. The thickness measurement result exceeds the wear limit of the main hull member pursuant to Subparagraph 3 or excessive
도한 부식이 발견된 부분에 대하여는 신환 등 수리하여 쇠모한도 이내가
되도록 조치한다. 이 경우 "과도한 부식"이란 과도한 부식이 있다고 의심되
는 부위의 측정치와 의심되는 부위가 아닌 구역의 가장 큰 측정치를 비교
하여 그 차이가 제3호에 따른 쇠모한도를 초과한 경우를 말한다.
나. 측정 결과는 측정자 및 담당검사관이 서명한 기록으로 남겨야 한다.