Annex 1 — 화재의 예방 및 안전관리에 관한 법률 시행령

287389 · 2026-07-01

■ Enforcement Decree of the Act on the Prevention of Fire and Safety Management [Appendix 1] For the location, structure, and management of facilities or equipment such as boilers and the like, and for fire prevention Matters to be observed when using fire (Related to Article 18, Paragraph 2) 1. Boiler a. Parts of a steam engine or chimney in contact with a combustible wall, floor, or ceiling It must be covered with flame-retardant or non-combustible insulation materials such as clay. B. When using liquid fuels such as diesel or kerosene, the following must be observed. 1) The fuel tank shall be installed at a horizontal distance of at least 1 meter from the boiler body things to do 2) The fuel tank is equipped with a fuel shut-off device capable of shutting off the fuel in the event of an emergency such as a fire Install the START shut-off valve within 0.5 meters of the fuel tank. 3) Install a filtration device in the piping supplying fuel to fuel tanks or boilers, etc. To Do 4) Do not use fuels other than those permitted 5) Install a support so that the fuel tank does not tip over, and the fuel tank and fuel tank The base is made of non-combustible material pursuant to Article 2, Item 10 of the Enforcement Decree of the Building Act (hereinafter referred to as “non-combustible material (shall be referred to as "fee") . When using gaseous fuel, the following must be observed. 1) In the place where the boiler is installed, install ventilation openings, etc., so that flammable gases do not accumulate does not 2) Fuel supply piping shall be made of metal pipes 3) A shut-off valve capable of cutting off fuel in case of emergency such as fire, from the fuel container, etc. 터 0.5미터 이내에 설치할 것 4) Install a gas leak alarm at the location where the boiler is installed D. When using solid fuels such as firewood, the following must be observed. 1) Solid fuel must be stored at a horizontal distance of at least 2 meters from the boiler body, or Store in a separate partitioned space made of non-combustible materials. The chimney is 0.6 meters away from the ceiling, and the chimney outlet is outside the building. Install so that it extends at least 0.6 meters 3) The flue outlet shall be installed at least 2 meters higher than the boiler body 4) Walls, roofs, etc., through which the chimney passes shall be treated with non-combustible materials 5) The chimney material shall be non-combustible and a cleaning port shall be installed at the connection point. E. The distance between the boiler body and the wall/ceiling must be at least 0.6 meters. B. When installing the boiler indoors, non-combustible materials other than concrete floors or metal It must be installed on a floor made of material. 2. Stove a. The chimney shall be at least 0.6 meters away from the ceiling, and the chimney outlet shall be outside the building . b. Parts of the chimney in contact with combustible walls, floors, or ceilings made of flame-retardant materials such as diatomaceous earth or must be covered with non-combustible insulation. Portable heaters must not be used in the following places. However, if the heater tips over... To prevent this, place a support to secure it, or in the event of it falling over, extinguish it immediately and fuel This is not the case if a device capable of blocking leakage of is attached. 1) pursuant to Article 2, Paragraph 1, Subparagraph 4 of the “Special Act on Safety Management of Multi-Use Facilities” Usage Establishment 2) A school pursuant to Article 2, Subparagraph 1 of the "Act on the Establishment and Operation of Private Educational Institutions and Private Tutoring" Won Article 2, Paragraph 1, Subparagraph 4 of the Enforcement Decree of the Act on the Establishment and Operation of Private Educational Institutions and Private Tutoring number 4) Accommodation business pursuant to Article 2, Paragraph 1, Subparagraph 2 of the "Public Health Management Act," and Subparagraph 3 of the same Paragraph and laundry business pursuant to subparagraph 6 of the same paragraph Clinics, dental clinics, and Korean medicine clinics pursuant to Article 3, Paragraph 2, Subparagraph 1 of the Medical Service Act, and the same paragraph Midwifery centers pursuant to Subparagraph 2 and hospitals, dental hospitals, and oriental medicine hospitals pursuant to Subparagraph 3 of the same paragraph · Nursing Hospital · Psychiatric Hospital · General Hospital 6) Business premises of a food service business pursuant to Article 21, Subparagraph 8 of the Enforcement Decree of the Food Sanitation Act Film screening pursuant to Article 2, Subparagraph 10 of the Act on the Promotion of Films and Video Materials Tube 8) A performance venue pursuant to Article 2, Subparagraph 4 of the “Performance Act” 9) Museums pursuant to Article 2, Subparagraph 1 of the “Museum and Art Gallery Promotion Act” and Article 2 of the same Act number Shopping district pursuant to Article 2, Subparagraph 7 of the Distribution Industry Development Act 11) Temporary building pursuant to Article 20 of the "Building Act" 12) Station/Terminal 3. Drying equipment a. The distance between the drying equipment and the walls and ceilings shall be at least 0.5 meters. b. Ensure that the drying material does not come into direct contact with the heat source. . When installed indoors, the walls, ceiling, and floor must be made of non-combustible materials. 4. Gas and Electric Facilities a. In the case of gas facilities, the “High-Pressure Gas Safety Management Act,” the “City Gas Business Act,” and the “Liquefied It shall be in accordance with the provisions of the “Act on Safety Management and Business of Petroleum Gas.” b. In the case of electrical facilities, as prescribed by the Electric Power Business Act and the Electric Safety Management Act follows. 5. Welding and cutting mechanisms using sparks In welding or cutting workplaces, the following items must be observed. However, "Industrial It does not apply to workplaces subject to Article 38 of the Occupational Safety and Health Act. a. Fire extinguishers shall be provided within a 5-meter radius of the welding or cutting workplace b. Do not stack flammable materials within a 10-meter radius of a welding or cutting workplace Do not leave them exposed. However, if removal of combustible materials is difficult, protective measures such as fireproof blankets may be taken. is performed are excluded. 6. Furnace & Oven Equipment a. When installed indoors, on an earthen floor or a floor made of non-combustible materials other than metal must be installed. b. The walls and ceilings of the place where a furnace or hearth is installed must be made of non-combustible materials . . Around the furnace or hearth, a height of at least 0.1 meters must be installed. d. In the case of installing a furnace with a heat output of 300,000 kilocalories per hour or more, the following Must observe the START clause. 1) A main structural member pursuant to Article 2, Paragraph 1, Subparagraph 7 of the “Building Act” (hereinafter referred to as “main structural member”) ) shall be made of non-combustible material or higher Windows and doorways shall be fire doors with a fire resistance of 60 min or more pursuant to Article 64 of the Enforcement Decree of the Building Act or Install as a 60-minute fire door 3) Ensure a space of at least 1 meter around the oar 7. Equipment installed for food preparation In the kitchen of a general restaurant among food service businesses pursuant to Article 21, Item 8 of the Enforcement Decree of the Food Sanitation Act , the following subparagraphs MTQ721e3ceef283e77000283 Must observe the START clause. a. Exhaust ducts (air exhaust passages) attached to kitchen equipment shall be galvanized steel of 0.5 mm or more Install with steel plates or non-combustible materials of equal or superior corrosion resistance a. Filters, etc. capable of removing animal or plant oils shall be installed in kitchen facilities. thing Heat-generating cookware must be kept at least 0.6 meters away from ceilings or shelves. Do . Flammable main Structural parts shall be covered with insulating, non-combustible materials Remarks 1. “Boiler” refers to one used in a workplace or commercial establishment, etc., and when used in a residential building Household boilers that start MTQ721e3ceef283e77000294 are excluded. 2. “Drying equipment” refers to industrial drying equipment, excluding drying equipment used in residential buildings. . 3. “Furnace and oven equipment” refers to those used in manufacturing and processing industries, and cooking in a residential Ovens used for START purposes are excluded. 4. Boilers, stoves, drying equipment, welding and cutting equipment using flames, and furnace and stove equipment At least one fire extinguisher must be provided in the installed location.