Annex 4 — 해양경찰장비 도입 및 관리에 관한 법률 시행령
285819 · 2026-05-06
■ Enforcement Decree of the Act on the Introduction and Management of Coast Guard Equipment [Appendix 4]
Implementation Period and Evaluation Items for Safety Evaluation (Related to Article 9)
1. Implementation Period of Safety Evaluation
┌─────────┬──────────┬──────────┬─────────┐
│Vessel Classification │1st Evaluation │2nd Evaluation │3rd Evaluation │
├─────────┼──────────┼──────────┼─────────┤
│A. Steel Ship │When the vessel reaches 21 years of age │When the vessel reaches 24 years of age │After conducting the 2nd evaluation 5│
│ │Until December 31 of the year │Until December 31 of the year │In the range of years Ocean│
├─────────┼──────────┼──────────┤As determined by the Commissioner General of the National Police Agency │
│B. Aluminum wire │When the vessel reaches 16 years of age │When the vessel reaches 19 years of age │UntilPeriod │
├─────────┤Until December 31 of the year │Until December 31 of the year │ │
│. Reinforced plastic line│ │ │ │
└─────────┴──────────┴──────────┴─────────┘
Note: The age of the vessel under Item 1 shall be calculated from the date the vessel was launched.
2. Evaluation Items for Safety Assessment
┌─────────────┬────────┬──────────────────┐
│Vessel Classification │1st Evaluation │2nd and 3rd Evaluation │
├──────────┬──┼────────┼──────────────────┤
│a. Steel wire │Hull│1) Phenomenon Evaluation │1) Current Status Evaluation │
│B. Aluminum wire │ │ │ │
│ │ │2) Thickness Measurement │2) Thickness Measurement │
│ │ │ │ │
│ │ │ │3) Strength Evaluation │
│ │ │ │ │
│ │ │ │4) Fatigue Strength Evaluation (Applicable only to steel wire) │
│ │ │ │ │
│ │ │ │5) Non-destructive evaluation (aluminum wire only)│
│ ├──┼────────┼──────────────────┤
│ │Engine│1) Current Status Evaluation │1) Current Status Evaluation │
│ │ │ │ │
│ │ │2) Performance Evaluation │2) Performance Evaluation │
│ │ │ │ │
│ │ │3) Sea trial operation│3) Sea trial operation │
│ │ │ │ │
│ │ │ │4) Safety Device Evaluation │
│ ├──┼────────┼──────────────────┤
│ │Electric│1) Current Status Evaluation │1) Current Status Evaluation │
│ │ │ │ │
│ │ │2) Performance Evaluation │2) Performance Evaluation │
│ │ │ │ │
│ │ │ │3) Distribution Panel Circuit Breaker Evaluation │
│ │ │ │ │
│ │ │ │4) Dielectric Strength Evaluation │
├──────────┼──┼────────┼──────────────────┤
│ │Hull│ProjectEvaluation │ProjectEvaluation │
│ ├──┼────────┼──────────────────┤
│. Reinforced plastic line │ │1) Current Status Evaluation │1) Current Status Evaluation │
│ │Institution│ │ │
│ │ │2) Performance Evaluation │2) Performance Evaluation │
│ │ │ │ │
│ │ │3) Sea trial operation│3) Sea trial operation │
│ │ │ │ │
│ │ │ │4) Safety Device Evaluation │
│ ├──┼────────┼──────────────────┤
│ │Electric│1) Current Status Evaluation │1) Current Status Evaluation │
│ │ │ │ │
│ │ │2) Performance Evaluation │2) Performance Evaluation │
│ │ │ │ │
│ │ │ │3) Distribution Panel Circuit Breaker Evaluation │
│ │ │ │ │
│ │ │ │4) Dielectric Strength Evaluation │
└──────────┴──┴────────┴──────────────────┘