Annex 3 — 중대재해 처벌 등에 관한 법률 시행령
277417 · 2025-10-01
■ Enforcement Decree of the Act on the Punishment, etc. of Serious Accidents [Appendix 3]
Public use facilities among the facilities under Article 2, Subparagraph 4, Item (b) of the Act (related to Article 3, Subparagraph 2)
┌──────────┬──────────────────────────────┐
│1. Bridge │ │
│ │ │
│ a. Road Bridge │ 1) The superstructure type is a suspension bridge, cable-stayed bridge, arch bridge, and truss bridge │
│ │Bridge │
│ │ 2) Bridges with a maximum span of 50 meters or more │
│ │ 3) Bridges with a length of 100 meters or more │
│ │ 4) Covered structure with a width of 6 meters or more and a length of 100 meters or more │
│ │ │
│ B. Railway Bridge │ 1) High-speed railway bridge │
│ │ 2) Bridges and viaducts of urban railways │
│ │ 3) Bridges with superstructure types of truss bridges and arch bridges │
│ │ 4) Bridges with a length of 100 meters or more │
├──────────┼──────────────────────────────┤
│2. Tunnel │ │
│ │ │
│ a. Road Tunnel │ 1) Tunnels with a length of over 1,000 meters │
│ │ 2) Tunnel with 3 or more lanes │
│ │ 3) Underpass with a tunnel section length of 100 meters or more │
│ │ 4) Tunnels on Expressways, National Roads, Special City Roads, and Metropolitan City Roads │
│ │ 5) Tunnels on provincial, city, county, and district roads with a length of 300 meters or more │
│ │ │
│ B. Railway Tunnel │ 1) High-speed railway tunnel │
│ │ 2) Urban railway tunnel │
│ │ 3) Tunnels with a length of over 1,000 meters │
│ │ Tunnels located in a Special City or Metropolitan City │
├──────────┼──────────────────────────────┤
│3. Port │ │
│ │ │
│ a. Breakwater, wave breakwater│ 1) Breakwater with an extension of 500 meters or more │
│(波除堤) and Ho │ 2) Breakwaters extending over 500 meters │
│An │ 3) Revetment with an extension of 500 meters or more functioning as a breakwater │
│ │ │
│ B. Mooring Facilities │ 1) Crude oil buoy mooring facilities of 10,000 tons or more (subsea facilities as auxiliary facilities │
│ │(Includes oil pipeline) │
│ │ 2) Mooring facilities of pile structure with a capacity of 10,000 tons or more │
│ │ 3) Gravity mooring facilities of 10,000 tons or more │
├──────────┼──────────────────────────────┤
│4. dam │ 1) Multipurpose dam, power generation dam, flood control dam │
│ │ 2) Local Water Supply Exclusive Dam │
│ │ 3) Water-only dams with a total reservoir capacity of over 1 million tons │
├──────────┼──────────────────────────────┤
│5. Buildings │ 1) High-speed rail, urban rail, and metropolitan rail station facilities │
│ │ Buildings with 16 floors or more or a gross floor area of 30,000 square meters or more │
│ │ 3) Gross floor area of 5,000 square meters or more (referring to the sum of facilities by use │
│ │da) │
│ │Passenger facilities, medical facilities, facilities for the elderly and children, training facilities, sports facilities, │
│ │Tourist accommodation facilities and tourist rest facilities among accommodation facilities │
├──────────┼──────────────────────────────┤
│6. River │ │
│ │ │
│ a. Estuary Dam │ 1) Estuary dam │
│ │ 2) Seawall with a tidal capacity of over 10 million tons │
│ │ │
│ Na. Embankment │ Embankments of national rivers [accessible facilities and revetments │
│ │Includes] │
│ │ │
│ . Bo │ Multifunctional weir installed in national rivers │
├──────────┼──────────────────────────────┤
│7. Water Supply & Sewerage │ │
│ │ │
│ A. Water Supply │ 1) Wide-area water supply │
│ │ 2) Industrial Water Supply │
│ │ 3) Local Water Supply │
│ │ │
│ B. Sewerage │ Public wastewater treatment facilities with a maximum daily treatment capacity of 500 tons or more │
├──────────┼──────────────────────────────┤
│8. Retaining Wall and Cut Slope │ 1) │
│(Cut Slope) │Retaining wall over 100 meters │
│ │ 2) Vertical height from the ground (if there is a retaining wall, above the retaining wall │
│ │(Refers to the height from the START) Sections including 30 meters or more │
│ │As an excavated section (referring to the cut section), a single horizontal extension of 100 │
│ │meters │
└──────────┴──────────────────────────────┘
Remarks
1. “Road” refers to a road under Article 10 of the Road Act.
2. The “maximum span length” of a bridge refers to the centerline between the piers of the superstructure within a single span
When the distance between spans is defined as the span length, it refers to the maximum value among the span lengths of the bridge.
For bridges, the distance between the breast walls of the abutments on both sides of the bridge, measured along the bridge centerline
says.
3. The “length” of a bridge refers to the distance between the breast walls of the abutments on both sides of the bridge, measured along the bridge centerline
says.
4. The term “covered structure” of a road bridge refers to all structures that cover a river, etc., and use it for road purposes
refers to a structure.
5. The “extension” of tunnels and underpasses refers to the section connected to each main body section as a single structure
refers to the distance including.
6. “Breakwater, wave-breaking structure, and revetment” refers to the outer facilities under Article 2, Subparagraph 5, Item (a) 2) of the Port Act
.
7. “Mooring facility” refers to a mooring facility under Article 2, Subparagraph 5, Item (a) 4) of the Port Act.
8. “Dam” means a reservoir under Article 2, Paragraph 1 of the “Act on Safety Management and Disaster Prevention of Reservoirs and Dams”
Refers to reservoirs and dams.
9. The dams exclusively for local water supply and the dams exclusively for water supply under Item 4 of the above table are the wide-area water supply
ㆍIn cases corresponding to water source facilities of industrial water supply or local water supply,
It is considered a water supply and sewage facility.
10. The buildings in the table above include retaining walls and cut slopes as ancillary facilities, building equipment, firefighting
Facilities, elevator facilities, and electrical facilities are not included.
11. The gross floor area of a building shall be calculated per building, including basement floors. However, for buildings with two or more buildings
In cases where they are connected as a single structure, and in cases where two or more underground shopping arcades are continuous,
It shall be the sum of the gross floor areas.
12. The number of stories of a building includes floors with pilotis or other similar structures.
13. “Building” follows the classification by use prescribed in Annex 1 of the Enforcement Decree of the Building Act.
14. “Passenger facilities among transportation facilities” refers to transportation facilities under Item 8 of Annex 1 of the Enforcement Decree of the Building Act
Refers to passenger bus terminals, general railway stations, airport terminals, and port passenger terminals.
15. “Railway station facilities” refers to Article 2 of the “Act on the Construction of Railways and Maintenance of Railway Facilities”
It refers to the station facilities under Subparagraph (a) of Item 6 (excluding logistics facilities). However, a loading and unloading station (where the facility is a railway
The track section (referring to the station installed below) is included in the continuous bridge facilities, and the
The track section of the loading and unloading station is included in the continuous tunnel facilities.
16. If a river facility is located on the boundary of an administrative district, it shall be deemed to be located in the higher administrative district.
17. “Inclusive tidal volume” refers to the amount of tidal water that will flow into the reclaimed land at the time of maximum high tide
.
18. The term “seawall” refers to Article 37 of the “Act on the Management and Reclamation of Public Waters,” and the “Rural Development Act.”
Article 2, Subparagraph 6, Article 2, Subparagraph 1 of the Seawall Management Act and the Industrial Location and Development Act
Refers to a seawall installed pursuant to Article 20, Paragraph 1.
19. A “passage” in a river refers to a structure having a gate with a circular cross-section installed by penetrating an embankment
says.
20. A “multifunctional weir” of a river refers to securing water, small-scale hydroelectric power generation, or roads (as crossing the river
It refers to a beam having two or more functions, such as (limited to ).
21. For the wide-area water supply, industrial water supply, and local water supply of the water and sewage systems in Item 7 of the above table, the water source designation
Includes water intake and transmission pipelines (including tunnels) and water intake facilities, water purification plants, and water intake facilities.
Booster pump stations, reservoirs, drainage pipelines, and water supply facilities are excluded.