Annex 1 — 건축물관리법 시행령
284661 · 2026-03-24
■ Enforcement Decree of the Building Management Act [Attached Table 1] <Amended Jan. 5, 2021>
Requirements for Building Management Inspection Agencies (Related to Article 12, Paragraph 2)
1. Inspection Agencies for Regular Inspections, Emergency Inspections, and Small-Scale Aging Buildings, etc.
A. Technical Personnel: Must possess all of the following technical personnel according to the scale of the inspection target.
┌────────────────┬────────────────────────┐
│Classification │Scale of Inspection │
│ ├──────┬──────┬──────────┤
│ │Gross Floor Area │Gross Floor Area │Gross Floor Area │
│ │3 thousand square meters │3 thousand square meters │10,000 square meters or more │
│ │less │or more │ │
│ │ │10,000 square meters │ │
│ │ │less │ │
├────────────────┼──────┼──────┼──────────┤
│1) Architect pursuant to the "Architects Act", │1 or more people │1명 이상 │1 or more people │
│「Enforcement Decree of the Construction Technology Promotion Act」 │ │ │ │
│Building structure according to Attached Table 1, building │ │ │ │
│Construction or Construction Safety Specialization │ │ │ │
│'s top-class construction technology │ │ │ │
├────────────────┼──────┼──────┼──────────┤
│2) Architect pursuant to the "Architects Act" │2 or more people │3명 이상 │4 or more people │
│and │ │ │ │
│is the "Enforcement of the Construction Technology Promotion Act │ │ │ │
│Construction duties pursuant to Annex 1 of the "Ordinance" │ │ │ │
│Entry-level construction technician in the START field or higher │ │ │ │
│person │ │ │ │
└────────────────┴──────┴──────┴──────────┘
B. Equipment: Be equipped with all of the following equipment
1) Telescope, crack width gauge
2) Laser Rangefinder
3) Thermal Imaging Camera
4) Electronic Endoscope
5) Survey instrument[Level(水準: relative height between points or height from mean sea level
says. The same applies below)ㆍFor angle measurement]
2. Safety Inspection Agency
┌──────┬──────────────────────────────────┐
│Classification │Requirements │
├──────┼──────────────────────────────────┤
│A. Capital │It will be over 100 million │
├──────┼──────────────────────────────────┤
│ │ │
│ │ │
│B. Technical Manpower│Possess all of the following technical personnel │
│ │ 1) Persons falling under any of the following: 2 or more. In this case, an architect or │
│ │At least 50% of the professionals in the architecture job field must be Special Grade Construction Engineers. │
│ │ a) an architect pursuant to the "Architects Act" (buildings with a gross floor area of 5,000 square meters or more │
│ │(Applicable only to persons with experience in design or supervision of such materials) │
│ │ b) Architectural job fields pursuant to Annex 1 of the Enforcement Decree of the Construction Technology Promotion Act or construction│
│ │Special Class Construction Engineer in the Field of Construction Safety │
│ │ 2) Architectural job field pursuant to Annex 1 of the Enforcement Decree of the Construction Technology Promotion Act or Construction│
│ │Persons holding an intermediate-level construction technician qualification or higher in a specialized safety field: 3 or more. In this case │
│ │At least 60% must be intermediate-level construction engineers or higher in the architecture job field. │
│ │ 3) Architectural job field pursuant to Annex 1 of the Enforcement Decree of the Construction Technology Promotion Act or Construction│
│ │Persons holding at least entry-level construction technical expertise in the safety specialty: 3 or more │
│ │ │
│ │ │
├──────┼──────────────────────────────────┤
│. Equipment │Equip with all of the following equipment │
│ │ 1) Crack width gauge (7x magnification or higher, must be of the light-attached type) │
│ │ Rebound hardness (referring to the degree of hardness based on the height of bouncing) │
│ │d) Measuring instrument (including calibration device) │
│ │ 3) Ultrasonic detector (capable of resolving ultrasonic transmission time to 0.1 μs) │
│ │ 4) Rebar Detection Equipment │
│ │ 5) Rebar corrosion measuring equipment (measurement by natural potential method or electric resistance method │
│ │possible) │
│ │ 6) Salinity measuring equipment │
│ │ 7) Core extractor │
│ │ 8) Film (paint coating) thickness measuring equipment (measurement range shall be 0.1 mm or less) │
│ │ 9) Surveying instrument (for leveling, angle, and distance measurement) │
│ │ 10) Steel Non-destructive Testing Equipment │
│ │ a) Magnetic Particle Inspection Machine │
│ │ b) Ultrasonic testing machine │
│ │ 11) Vibration meter │
│ │ 12) Static deformation measuring device │
└──────┴──────────────────────────────────┘
Remark: "Capital" in the case of a corporation refers to the paid-in capital for performing safety diagnosis work or
It refers to capital contributions, and in the case of an individual, it refers to the valuation of business assets.