Annex 3 — 대기관리권역의 대기환경개선에 관한 특별법 시행령

287109 · 2026-07-01

■ Enforcement Decree of the Special Act on the Improvement of Air Environment in Air Management Zones [Table 3] <Amended Oct. 1, 2025> Types of measuring instruments, installation and management methods, and methods for calculating emissions, etc. (Related to Article 22) 1. Types of Measuring Instruments by Facility Subject to Installation a. Automatic chimney measuring instrument Pollutants subject to total emission control are discharged from the business site of an operator allocated a total allowable emission limit. Automatic chimney monitoring devices must be installed at all discharge outlets. However, the following Any discharge outlet corresponding to any one of the following is excluded from the attachment requirement. 1) Annual operating days are 30 days or 720 hours (for boilers using gaseous fuel, annually Discharge outlet of an emission facility with an operating period of less than 90 days 2) Emission outlets of emission facilities that are closed within 6 months from the date they become subject to attachment 3) Outlet of a boiler switching to clean fuel within 6 months (sulfur oxides · Applies only to dust measuring devices) 4) Discharge outlet of an emission facility with a continuous operating time of less than 8 hours per day 5) Delete <2024. 8. 13.> Total emission management business allocated a total allowable emission amount for nitrogen oxides, sulfur oxides, or dust , the previous year's discharge amount of each managed pollutant is any of the following 에 해당하는 배출구 a) Annual nitrogen oxide emissions of 3 tons or less (applies only to nitrogen oxide measuring devices) b) Annual sulfur oxide emissions of 3 tons or less (applies only to sulfur oxide measuring devices) ) Annual dust emissions are 0.15 tons or less (applies only to dust measuring devices) 7) In petrochemical, refining, steel industries, etc., flammable gases for fire or safety reasons Automatic measurement of chimneys, etc., that cause combustion [referring to flare stacks, etc.] It is physically impossible to measure air pollutant emissions through the device, and or emission outlets recognized as dangerous by the Minister of Climate, Energy and Environment or the Mayor/Do Governor B. Fuel Flow Meter Among the facilities corresponding to the proviso in the part other than items 1) through 7) of subparagraph A, liquid and gaseous fuels must be equipped with a fuel flow meter. However, facilities subject to installation This does not apply if the emission facility is closed within 6 months from the START date. Remarks 1. In cases where there are two or more emission outlets at the same workplace, the "Environmental testing and inspection, etc." Environmental Pollution Process Testing Standards pursuant to Article 6, Paragraph 1 of the Act concerning [Environmental Pollution Process Testing Standards] (hereinafter referred to as "Environmental Pollution Process Testing Standards") ), an intermediate data collector (FEP: Front End Processor) is attached must be kind. 2. In the case of incineration facilities, the exhaust port temperature and the final combustion chamber outlet temperature shall be measured respectively A temperature measuring device capable of measuring temperature must be attached in accordance with the "Waste Management Act." However, in accordance with the Waste Management Act, This is not the case if a regular device is attached. 3. In the case of attaching automatic chimney measuring devices, exhaust gas flow meters and exhaust gas thermometers must be additionally attached, and air pollution pursuant to Article 16, Paragraph 1 of the Air Environment Preservation Act In the case of facilities where standard oxygen concentration is applied to the permissible emission standards for substances, oxygen measurement device must be attached. 4. Exclusion of the proviso to the part other than Subparagraphs 1) through 7) of Item (a) of Subparagraph 1 and the proviso to Subparagraph (b) of the same subparagraph If the reason for exclusion has ceased to exist, measurement must be made within 6 months from the date the relevant reason for exclusion ceased to exist. The device must be attached. Notwithstanding the grounds for exclusion of attachment of the proviso in the part other than subparagraphs 1) through 7) of Item (a) of Subparagraph 1, Subparagraph (mt) Automatic chimney measuring instruments pursuant to Article 17, Paragraph 5 and Annex 3 of the Enforcement Decree of the Air Environment Preservation Act In the case of emission facilities subject to the installation of , automatic chimney monitoring equipment must be installed. 6. Delete <2024. 8. 13.> 2. Installation and Management Standards for Measuring Instruments a. Automatic chimney measuring instrument Total load management operators shall ensure that the structure and performance of measuring instruments comply with the Environmental Pollution Process Testing Standards . Total load management business operators pursuant to Article 9, Paragraph 1 of the "Act on Testing and Inspection, etc. in the Environmental Field" Measuring instruments that have received type approval pursuant to the main text (proviso to the same paragraph and Paragraph 2 of the same article Includes the corresponding automatic chimney measuring device. (As in 3) below) installed, and the same must undergo a quality inspection pursuant to Article 11 of the Act, and the results of the quality inspection Chimney remote monitoring system pursuant to Article 19, Paragraph 1, Subparagraph 1 of the Enforcement Decree of the Air Environment Preservation Act must be notified to the Control Center (hereinafter referred to as the "Control Center"). However, Environmental Pollution Process Test criteria The above is deemed to have received type approval and accuracy inspection. Total quantity management operators must constantly transmit measurement data based on measuring devices to the control center. . Total Emission Management Operators who newly install or replace chimney exhaust gas temperature measuring devices In the case of the agency dedicated to national calibration services pursuant to Article 14, Paragraph 3 of the National Standards Framework Act, must be performed, and the record must be preserved for the duration of the measuring instrument's operation. However, in accordance with the main text of Note 3 of Annex 3 of the "Enforcement Decree of the Air Environment Preservation Act," on temperature measuring instruments, as "Industrial Standard In the case of using products that satisfy Korean Industrial Standards (KS) pursuant to the "Standardization Method," That is not the case. B. Fuel flow meter 1) In the case of installing or replacing a fuel flow meter, a total quantity management business operator [must] [require] the "National ...received calibration from a national calibration agency dedicated to national calibration services pursuant to Article 14, Paragraph 3 of the Framework Act on Standards must be done, and the record must be preserved for the duration of the measuring instrument's operation. The business operator must take measures such as sealing to prevent unauthorized manipulation of the fuel flow meter. . 3. Installation timing of measuring instruments a. Measuring instruments are in accordance with Article 30, Paragraph 1 of the "Air Environment Preservation Act" or the "Integrated Environmental Pollution Facilities which must be attached by the date of the report on the commencement of operation pursuant to Article 12, Paragraph 1 of the Act on Management . However, for workplaces falling under any of the following, the annual emissions are [attached to Table 2 In the case of workplaces that must install new measuring devices due to exceeding emission limits under START, must be attached within one year from the date of receiving the installation permit for the total quantity management workplace. 1) Pursuant to Article 23 of the Air Environment Preservation Act, obtaining a permit for the installation of emission facilities or new installation Workplace that reported A business permitted pursuant to Article 6 of the "Act on the Integrated Management of Environmental Pollution Facilities" CHANG b. Notwithstanding subparagraph (a), in the case of an outlet falling under any of the following subparagraphs The business operator submitted a plan for the installation of self-contained automatic chimney monitoring equipment, and the Climate Energy Environment If approved by the Minister, the timing of attachment may be changed. 1) Additional provisions for the installation of safety equipment, etc., to prevent industrial accidents when installing automatic chimney measuring devices As it is necessary to ensure appropriate work safety, complying with the attachment timing according to item A is Difficult outlet 2) As improvement and reinforcement of facilities are necessary for the installation of automatic chimney measuring equipment, in item (a) exhaust outlet where it is difficult to comply with the attachment timing 3) Due to supply issues with automatic chimney measuring devices, the installation timing pursuant to Item (a) is a difficult discharge outlet 4) To ensure work safety during the installation of automatic chimney measuring equipment, operate a series of continuous processes Emission outlets of emission facilities that operate continuously for more than one year among emission facilities that must be suspended 4. Emission Calculation Method a. Calculation method by automatic chimney measuring device 1) Criteria for Calculation of Measurement Data a) 30-minute emissions are calculated in grams (g), and decimal places are truncated Calculate as an integer. b) Monthly emissions are calculated by summing 30-minute emissions on a monthly basis and converting them to kilograms. After starting, the decimal part is truncated to calculate the integer. 2) The rounding of numerical values ​​of measurement data is Korean Industrial Standard KS Q 5002 (Statistical interpretation of data method. In this case, round the decimal part to the third decimal place calculates. 3) Emission Calculation Method ┌─────┬──────────────────────────────────┐ │pollutant │Calculation method for emissions (g) │ ├─────┼──────────────────────────────────┤ │Nitrogen Oxides│ 30-minute average concentration (ppm) × 30-minute exhaust gas cumulative flow rate (S㎥) × 10⁻³ × 46 ÷ 22.4 │ │Sulfur oxide │ 30-minute average concentration (ppm) × 30-minute accumulated exhaust gas flow rate (S㎥) × 10⁻³ × 6⁴ ÷ 22.4 │ │Dust │ 30-minute average concentration (mg/S㎥) × 30-minute accumulated exhaust gas flow rate (S㎥) × 10 - 3 │ └─────┴──────────────────────────────────┘ B. Calculation method by fuel flow meter ┌─────────────────────────────────────┐ │Monthly fuel consumption × Pollutant emission factor by fuel × (1-Pollution control facility efficiency/100)│ └─────────────────────────────────────┘ Remarks 1. The pollutant emission factors for each relevant fuel are as prescribed by the Ordinance of the Ministry of Climate, Energy and Environment . Monthly fuel consumption can be corrected by considering fuel temperature, inherent errors of the measuring instrument, etc. There is. 3. The efficiency of pollution control facilities shall, in principle, be based on the design efficiency, and in cases where the design efficiency cannot be calculated refers to the generation of pollutants listed in the permit for the installation of a workplace pursuant to Article 15, Paragraph 1 of the Act It is calculated according to the following formula using the amount and emissions. ┌───────────────────────────┐ │Pollution Control Facility Efficiency (%) = (Emissions - Emissions) ÷ Emissions × 100 │ └───────────────────────────┘