Annex 1 — 가습기살균제 피해구제를 위한 특별법 시행령

278493 · 2025-10-01

■ Enforcement Decree of the Special Act on Relief of Damages from Humidifier Disinfectants [Appendix 1] <Amended Oct. 1, 2025> Criteria for Determining Payment of Relief Benefits and Damage Grades (Related to Article 17, Paragraph 1) 1. Criteria for Determining Payment of Relief Benefits a. The Minister of Climate, Energy and Environment [reviews] the documents submitted by the applicant for relief benefits After reviewing in accordance with the standards established and notified by the Minister of Environment, after exposure to humidifier disinfectants If a disease develops or worsens, or if it is determined that the overall health condition has deteriorated, The payment of relief benefits is determined. In this case, the period of exposure to humidifier disinfectants and exposure Exposure patterns such as the degree, the temporal relationship between exposure and the occurrence of disease, and conditions before and after exposure The condition and diagnostic history must be considered comprehensively. b. Notwithstanding subparagraph a, the Minister of Climate, Energy and Environment [subject to Article 37 of the Act and Article 38 of this Decree] Claim data, etc. for medical benefit expenses pursuant to Article 47 of the National Health Insurance Act pursuant to the START clause Request and receive data that can verify the diagnostic history of the applicant for relief benefits , in accordance with the methods and procedures determined and notified by the Minister of Climate, Energy and Environment The payment of relief benefits can be decided promptly. 2. Grades of Health Damage from Humidifier Disinfectants a. The damage grade for health damage caused by humidifier disinfectants is determined in accordance with the first part of Article 15, Paragraph 1, the relief benefit [ ] The date the application for benefits was made, the date the request for payment of relief benefits was made pursuant to Article 17-2, or Article 18 Disposal carried out within 3 months prior to the date of application for renewal of the validity period pursuant to Paragraph 2 The decision shall be made by synthesizing the following test results among the performance test results, provided that if deemed necessary In the case of START, the decision may be made by considering clinical findings, imaging tests, medical certificates, etc. 1) Forced Vitality (FVC) 2) 1 second (FEV1) 3) Lung Diffusion Capacity (DLco) B. The damage grade criteria determined by synthesizing the inspection results of Item A 1) through 3) are as follows table. In this case, if the damage grades based on the inspection results are different, the disability The damage grade is determined based on the test result with the highest degree. ┌──────┬───────┬───────┬───────────────┐ │ TestMethod │Forceful Lung Capacity │1Cholyang(FEV1) │Lung Diffusion Capacity (DLco) │ │DamageRating │(FVC) │ │ │ ├──────┼───────┼───────┼───────────────┤ │High Altitude Damage │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │Less than 35% │Less than 35% │Less than 35% │ ├──────┼───────┼───────┼───────────────┤ │Altitude Damage │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │35% or more │35% or more │35% or more │ │ │Less than 45% │Less than 45% │Less than 45% │ ├──────┼───────┼───────┼───────────────┤ │Moderate damage │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │45% or more │45% or more │45% or more │ │ │Less than 55% │Less than 55% │Less than 55% │ ├──────┼───────┼───────┼───────────────┤ │Hardness Damage │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │55% or more │55% or more │55% or more │ │ │Less than 70% │Less than 70% │Less than 70% │ ├──────┼───────┼───────┼───────────────┤ │Minor damage │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │70% or more │70% or more │70% or more │ │ │Less than 80% │Less than 80% │Less than 80% │ ├──────┼───────┼───────┼───────────────┤ │Grade Others │of normal predicted values ​​ │of normal predicted values ​​ │of normal predicted values ​​ │ │ │80% or more │80% or more │80% or more │ └──────┴───────┴───────┴───────────────┘ Remarks 1. 1 second volume is considered valid only when it is less than 70/100 of forced vital capacity. 2. Normal predicted values ​​are the normal lung function predictions for Koreans published by the Korean Tuberculosis and Respiratory Diseases Society formula.