Annex 5 — 의약품 등의 안전에 관한 규칙

284019 · 2026-03-05

■ Rules on the Safety of Pharmaceuticals, etc. [Appendix 5] <Amended Oct. 4, 2024> Raw Plasma Management Standards (Related to Article 48, Subparagraph 11 and Article 60, Paragraph 2, Subparagraph 8) 1. Scope of Application This standard applies to raw plasma and water used in the domestic manufacture of plasma fraction products (or semi-finished products). Applies to raw plasma used in the manufacture of plasma fraction products (or semi-finished products). 2. Definition of Terms The meanings of the terms used in this standard are as follows. a. "Raw plasma" (hereinafter referred to as "plasma") refers to for the purpose of manufacturing a plasma fraction product Plasma or apheresis obtained by centrifuging human blood to exclude blood cells and platelets . B. "Plasma fraction products" refers to pharmaceuticals obtained through a series of manufacturing processes using plasma as a raw material . . "Semi-finished product" refers to 'fractions' used in the manufacture of plasma fraction products using plasma 5(Fraction V)'. a. "Plasma manufacturing facility" refers to a blood facility that manufactures plasma used as a raw material for plasma fraction products It refers to a collection center that extracts or harvests. E. "Plasma Importer" refers to an entity that imports plasma or semi-finished products to manufacture plasma fraction products. refers to an establishment. Bar. Delete <2022. 12. 7.> Company. "Plasma export business" refers to a foreign plasma manufacturer that exports plasma or semi-finished products to the domestic market. By storing and managing plasma or semi-finished products manufactured at a cow or its manufacturing facility, domestic . Ah. "Enzyme immunoassay" refers to methods that utilize the reaction between antigens and antibodies, such as the ELISA method MTQ46707daeb575061f01611Refers to the START test. . "Nucleic Acid Amplification Test" refers to amplifying nucleic acids to confirm the presence of contamination by bloodborne infectious agents refers to an inspection. . "Bloodborne infectious agents" refers to microorganisms, etc., that cause infectious diseases through blood. . K. "A blood donor refers to a person who provides blood or plasma. T. "Individual plasma" refers to plasma collected from one donor in a single instance. wave. "A 'mini pool' refers to individual plasma [acquired immunity Human Immunodeficiency virus (hereinafter referred to as "HIV"), MTQ46707daeb575061f01620STAR Hepatitis B virus (Hepatitis B virus, hereinafter referred to as "HBV"), Hepatitis C virus For the testing of [Hepatitis C virus, hereinafter referred to as "HCV"), etc., a certain [] refers to plasma collected from the stomach. H. "A Plasma Master File refers to [the] from plasma collection [the] It refers to a document containing information related to the process from collection, storage, and transportation. . "A look-back system refers to the Ministry of Food and Drug Safety at the current point in time Blood donors who test positive for viruses determined by the director, Cro Itsfeldt-Jakob Disease (CJD) or variant Creutzfeldt-Jakob Disease Feldt-Jakob disease (new variant Creutzfeldt-Jakob Disease, hereinafter referred to as "vCJD") Donors diagnosed with (or suspected of having vCJD), vCJD risk factors Areas where there is concern that [it] may exist, designated and notified by the Minister of Food and Drug Safety investigates the past donation records of local blood donors to ensure that the blood is not used to happen. . "Inventory hold" refers to the blood donor's virus-undetectable device (window period) In order to reduce the possibility of plasma being used in the manufacturing process, plasma in manufacturing refers to storing for a certain period before use. "Export plasma" refers to pharmaceuticals manufactured from plasma under the condition that the entire quantity is exported. refers to imported plasma. 3. Status Survey A. Request Procedure Manufacturers of plasma fraction products intending to use plasma from domestic plasma manufacturers, plasma import Businesses and importers of plasma fraction products must attach the following documents to the Ministry of Food and Drug Safety A request for an investigation into the actual situation must be made to the Director. However, regarding the manufacture of plasma fraction products for export... Plasma used is excluded from the status survey. 1) Matters concerning the organizational structure, facilities, education, etc. of the blood (plasma) business 2) Matters concerning the selection and management of blood donors 3) Blood (plasma) bags, blood collection, preparation of plasma, blood (plasma) testing, blood (plasma) storage and Details regarding transportation 4) Matters concerning the status of plasma usage and plasma traceability management 5) Other important matters deemed to be related to the safety of plasma B. Domestic plasma manufacturers 1) Subjects of Status Survey The subjects of the status survey are blood centers licensed pursuant to Article 6, Paragraph 3 of the Blood Management Act. It is a plasma manufacturing facility and is undergoing an examination pursuant to Article 7-2, Paragraph 5 of the Enforcement Decree of the Blood Management Act. In the case where an evaluation has been received and the results submitted, the status investigation conducted in accordance with these standards . 2) Formation of Fact-Finding Team The Minister of Food and Drug Safety shall form a fact-finding team to conduct a smooth fact-finding investigation and, in this case, the review and evaluation pursuant to Article 7-2, Paragraph 5 of the Enforcement Decree of the Blood Management Act Relevant experts, such as those in the START sector, may be invited to participate. . Plasma exporters and plasma manufacturers of imported plasma fraction products 1) Subjects of Status Survey The subjects of the status survey are as follows. However, the same plasma export business or plasma manufacturing business 에서 혈장 채취(또는 제조), 보관 시 같은 혈장관리체계를 갖추고 있음을 In cases where it is proven, the scope of the actual conditions survey may be adjusted. a) New plasma exporter or plasma manufacturer b) If a plasma exporter or plasma manufacturer acquires, merges, etc., the plasma management entity If the system, etc. is changed, etc. 2) Formation of Fact-Finding Team The Minister of Food and Drug Safety shall form a fact-finding team to conduct a smooth fact-finding investigation and in this case, relevant officials or experts from the Korean Red Cross participate may be recorded, and the Korean Red Cross, upon request from the Minister of Food and Drug Safety Must actively cooperate. . Regular inspections, etc. To domestic plasma manufacturers, plasma exporters, and plasma manufacturers of imported plasma fraction products A status survey shall be conducted at least once every five years regarding [the following]. However, if any of the following apply... is performed, a special fact-finding investigation may be conducted. Test results of plasma fraction product manufacturers or plasma importers showing a positive virus result If the judgment rate is high and it is determined that there is a problem with the plasma management of the plasma exporting company 2) A plasma exporter [regarding] the risk of bloodborne infectious agents to a plasma importer or If the government has been notified 3) A manufacturer of plasma fraction products or a plasma importer and an importer of plasma fraction products If the raw plasma master file pursuant to Subparagraph 5 is not submitted In addition, regarding the safety of plasma, the Minister of Food and Drug Safety [conducts] an investigation into the actual conditions... Where deemed necessary E. Expenses for Fact-finding Survey Manufacturers of plasma fraction products or plasma importers and importers of plasma fraction products revenue In accordance with the principle of self-burden, expenses necessary for the fact-finding survey shall be borne. B. Report on Fact-finding Survey Results The fact-finding team [investigated] domestic plasma manufacturers, plasma exporters, and the plasma of imported plasma fraction products Within 15 days after the completion of the on-site inspection of the soy sauce manufacturing facility, including the following items Must report to the Minister of Food and Drug Safety. 1) Matters concerning the size of the company and the nature of the legal entity, etc. 2) The license of that country for the blood collection institution and from that country's government agencies, etc. Details regarding periodic monitoring received over the past 5 years 3) Regarding blood testing equipment, blood collection methods, and testing methods, etc. possessed by the blood collection institution Items 4) Matters concerning the personnel composition of blood collection institutions 5) Virus test positivity rate of blood donors in the previous year of export 6) Matters concerning the recruitment and management of blood donors, etc. 7) In the event that problems such as viral infection occur regarding imported plasma, plasma import business Matters concerning the notification system of plasma exporters regarding cattle 8) Other important matters deemed to be related to the safety of plasma 4. Inspection Items for Fact-Finding Surveys The inspection items and standards for the fact-finding survey are as follows, and the detailed inspection items are The Minister of Food and Drug Safety shall determine separately. A. Facilities of plasma manufacturing plants, etc. All workrooms and work areas where blood management and manufacturing operations take place must be suitable for their intended use. Designed and managed to ensure that there is no impediment to the manufacturing and quality control of plasma, and maintained and managed 되도록 할 것 B. Personnel and organization of plasma manufacturing facilities, etc. Deployment of appropriately trained personnel, division of duties to maintain quality and production consistency and the corresponding organizational chart shall be prepared . Appropriateness of donor screening and blood collection processes Establish appropriate screening and exclusion criteria for blood donors and to qualified professionals Select a suitable blood donor through a medical history interview via START. d. Adequacy of Blood (Plasma) Tests Regarding blood (plasma) and disease agents such as bloodborne viruses (HIV, HBV, HCV) Perform appropriate tests and properly manage unsuitable blood (plasma) E. Manufacturing and Quality Control of Blood (Plasma) To ensure that the manufacturing, storage, transportation, and quality control of plasma are properly maintained and guaranteed thing B. Creation and Management of Records The process regarding plasma from collection and manufacturing to final treatment (storage, release, disposal, etc.) and keep it Company. Storage and Transport of Plasma Appropriate facilities and equipment capable of managing plasma according to specified storage and transport conditions 를 갖추고 유지할 것 Ah. In addition, regarding safety such as lookback A system capable of tracing from the blood donor to the final product supplier and a lookback system Things to have 5. Reporting of Raw Plasma Master Files Manufacturers and importers of plasma fraction products shall use the raw plasma of the plasma manufacturer The master file must be submitted in accordance with the regulations set by the Minister of Food and Drug Safety, and changes Regular annual reports must be submitted regarding the matters of . 6. Quarantine Storage and Lookback Processing a. Manufacturers of plasma fraction products shall isolate the plasma used for an appropriate period Must be stored. B. Plasma manufacturers and plasma fraction product manufacturers, donors determined to be subject to lookback , measures are taken in accordance with the regulations set by the Minister of Food and Drug Safety must. 7. Testing for plasma and plasma disposal a. Tests on plasma 1) Manufacturers of plasma fraction products or plasma importers shall, with respect to plasma, [refer to] the Food and Drug Safety Ministry Tests for bloodborne infectious agents determined by the Minister of Safety must be conducted, and tests , enzyme immunoassay (at the time with sensitivity equivalent to or greater than this (Including the experimental method), nucleic acid amplification testing must be performed on small amounts of collected plasma shall. However, the plasma fraction product manufacturer or plasma importer shall provide the following data , the relevant inspection agency's The test results can be replaced with the report. a) Data on testing laboratories for individual plasma and small-scale collected plasma (Name of testing laboratory, Note (Inc., on-site inspection information, operation or closure status, certification status of the relevant country, etc.) b) Data regarding testing methods, etc. for individual plasma and small-scale collected plasma (in-house developed In the case of nucleic acid amplification testing, include test method validation data) d) Equipment, kits, and testing procedures for enzyme immunoassay and nucleic acid amplification tests, etc. Ryo d) Related data such as the previous year's virus test positivity rate of plasma manufacturing facilities e) Results of enzyme immunoassay and nucleic acid amplification tests on plasma from plasma manufacturers 관한 자료 2) Plasma manufacturing facilities or plasma testing laboratories and plasma fraction product manufacturing facilities or plasma For long-term importers, the number of plasma bags mixed for nucleic acid amplification testing, standard samples used etc. shall have scientific evidence in place, and to enable the tracking of individual plasma inspection must be performed. Notwithstanding the proviso in Subparagraph 1) of Item A, the Minister of Food and Drug Safety's reliability of the inspection results etc. is necessary, the relevant inspection items , and the plasma importer receiving the request shall [review] the results . Plasma importers shall use only plasma that has been determined to have a final test result negative for pharmaceuticals. Must be used for manufacturing. B. Confirmation of imported plasma 1) Plasma importers, in order to verify the suitability of plasma imports, the blood donation of the relevant plasma The list of persons, test results, etc., must be submitted to the Korean Red Cross. 2) Plasma importers shall quarterly [review] the inspection results pursuant to Subparagraph 7(a) regarding imported plasma must be reported to the Minister of Food and Drug Safety for each. 3) In the case of reporting pursuant to 2), the plasma that was finally determined to be positive in subparagraph 1) Must include specifications of the inspection report. . Disposal of plasma Plasma, etc. that are unsuitable under Item 1) of Subparagraph (a) are, as prescribed by relevant laws such as the "Waste Management Act" must be disposed of in accordance with the bar. 2) 1), if intended for research use, it shall not be discarded, but the following requirements. a) If intended for research use, store and manage separately from other plasma and the country of export, date of import (including import declaration number), plasma number, test A ledger recording dates and test results, etc., must always be kept on hand. b) In cases where plasma is used for research purposes, the location, research purpose, researcher, and A ledger recording the dosage (including plasma number), etc., must be kept together. . 8. Verification of the adequacy of quarterly plasma use, etc. a. Manufacturers of plasma fraction products or plasma importers shall ensure the proper use of raw plasma and Look Back Target The fact that the Korean Red Cross conducts quarterly checks on the appropriateness of plasma management, etc. Must be verified in the START inspection. B. A manufacturer of plasma fraction products or a plasma importer, using raw plasma or raw plasma Regarding manufactured finished pharmaceutical products, in cases where matters related to product safety issues were pointed out It must be reported to the Minister of Food and Drug Safety immediately.