Annex 3 — 의약품 등의 안전에 관한 규칙
284019 · 2026-03-05
■ Rules on the Safety of Pharmaceuticals, etc. [Appendix 3-4] <Amended Dec. 29, 2022>
Standards for Manufacturing and Quality Control of Blood Products
(Related to Article 4, Paragraph 1, Subparagraph 6, Item (g), Article 48, Subparagraph 5, Item (g) and Subparagraph 9, Item (g) of the same article)
1. Definition of Terms
The meanings of the terms used in this standard are as follows:
a. "Blood" refers to blood as defined in Article 2, Paragraph 1 of the Blood Management Act, as a raw material for blood products
refers to using.
b. "Ineligible blood" refers to ineligible blood pursuant to Article 2, subparagraph 5 of the Blood Management Act.
. "Blood product" refers to a blood product as defined in Article 2, subparagraph 8 of the Blood Management Act.
a. "Blood product manufacturing facility" refers to a blood product licensed pursuant to Article 6, Paragraph 3 of the Blood Management Act
Among the [products] that have obtained pharmaceutical manufacturing and sales item approval pursuant to Article 31 of the Pharmaceutical Affairs Act
Refers to a pharmaceutical manufacturing facility.
E. "Blood donor" refers to a person who provides blood or plasma.
B. "A look-back system refers to the Minister of Food and Drug Safety at the current point in time
Blood donors who test positive for viruses specified by , Creutzfeldt-Jakob disease
Creutzfeldt-Jakob Disease (CJD) or variant Creutzfeldt-Jakob disease
Cobb disease (new variant Creutzfeldt-Jakob Disease, hereinafter referred to as "vCJD")
Diagnosed donors or donors suspected of having vCJD, regions with vCJD risk factors
or a blood donor who has traveled to an area with risk factors
It refers to a management procedure that investigates and ensures the relevant blood is not used.
Inc. "Blood screening test" refers to Article 8, Paragraph 1 of the Blood Management Act and Article 8, Paragraph 1 of the Enforcement Rules of the same Act
Refers to the inspection in accordance with the provisions of the START clause of
A. "Blood product testing" refers to, for each item of blood product for which a blood product manufacturer has received approval
Refers to a test conducted in accordance with the START standards and test methods.
. "Deviation" refers to an event that occurs in the manufacturing or quality control process outside of predetermined standards
refers to a virtuous act.
. "Deviation from standard" means that the results of a test deviate from the predetermined test or inspection standards
refers to the case where it occurred.
K. "Calibration" means the value indicated by a measuring instrument, test device, or recorder and the true value of a standard instrument
values to confirm that the error is within the allowable range, and the allowable error range
It refers to adjusting it so that it falls within the allowable range when it deviates.
. "Validation" refers to a specific process, method, equipment, or system that is pre-established
Verify that it consistently derives results that meet the established judgment criteria, and this
refers to documenting.
Part. "Qualification" refers to the fact that machinery and equipment are manufactured and installed as designed and operate as intended.
and proving and documenting that the desired result is obtained...
.
H. "Management Number" refers to an assignment made to manage materials, etc., to which a manufacturing unit cannot be assigned
refers to a number consisting of numbers, letters, or a combination thereof.
2. Management of Facilities and Environment
2.1 Facility Management
A blood product manufacturing facility is subject to the "Ordinance on Facility Standards for Manufacturers and Importers of Pharmaceuticals, etc." and the same
Necessary facilities must be provided in accordance with the facility standards set forth in the Enforcement Rules of the Act, and each of the following
item so that there is no hindrance to the manufacturing and quality control of blood products
Must maintain and manage and record the relevant details.
a. The facilities and equipment of a blood product manufacturing plant shall include workers, blood donors, blood and blood products
Design and arrange to minimize the occurrence of risks such as cross-contamination.
b. Calibration and
Conduct qualification assessment (excluding machinery and equipment deemed not to require calibration)
. It must be well-ventilated and able to block direct sunlight, and if necessary, air
Use a conditioning device or facility.
a. Blood, blood products, and specimens for testing and examination shall be stored according to the required storage conditions
Equipped with facilities capable of controlling temperature and, if necessary, humidity according to storage conditions, said facilities
be equipped with facilities for controlling the degree
E. Equip facilities capable of preventing rats, pests, dust, etc.
2.2 Management of Automation Devices, etc.
a. Automation devices, etc. for manufacturing and quality control (including computers or related systems.
), establish a plan and regularly perform calibration and performance checks
Perform START and record
a. Changes to records of automated devices, etc., shall be permitted only by authorized persons and appropriately
manage
All records generated by automated devices, etc., must be stored and preserved separately, and this [ ]
and alternative systems such as printouts, tapes, microfilms, and backup servers
so that it is not lost
2.3 Environmental Management
Regularly inspect manufacturing and storage conditions to ensure they are maintained at appropriate temperatures, and necessary
In the case of START, manage to maintain appropriate humidity.
3. Organization
3.1 Organizational Structure
a. A blood product manufacturer shall have a manufacturing department and a quality (assurance) department independent of each other, and respectively
A person in charge must be appointed, and in this case, they must not hold a dual position.
b. The person responsible under subparagraph (a) pursuant to Article 36, Paragraph 3 of the Pharmaceutical Affairs Act and Article 42, Paragraph 1 of these Rules
As a manufacturing manager, the person must possess sufficient knowledge regarding this Standard.
, if there is only one manufacturing manager at the relevant blood product manufacturer, that manufacturing manager
shall oversee the manufacturing department and the quality (assurance) department.
Blood product manufacturers are capable of appropriately performing manufacturing management and quality control tasks.
shall assign appropriate personnel, and the workers shall comply with this standard and their assigned duties
.
3.2 Manufacturing Department Manager
The head of the manufacturing department is responsible for the manufacturing process, manufacturing hygiene, and storage management of blood products.
As the head of the department, you shall implement the following items.
a. In order to properly manage manufacturing, product standards, manufacturing control standards, and manufacturing hygiene standards
must be written in name, signed, and approved on the standard document, and kept on hand and operated
.
b. Work in accordance with the manufacturing control standards and manufacturing hygiene control standards of Subparagraphs 4.2 and 4.4
and inspect and verify whether it is being manufactured, and in the event of any deviation, this
must be investigated and recorded.
. It is necessary to inspect and verify whether manufacturing hygiene management and storage management are being carried out in accordance with regulations
.
d. Qualification of critical machinery and equipment of the manufacturing department under the supervision of the Quality Department and
Validation for the START process must be performed and verified.
3.3 Quality (Assurance) Department Manager
The head of the Quality (Assurance) Department, of the department responsible for the quality control of blood, materials, and blood products,
As the person in charge, you shall implement the following items.
a. Whether blood products are tested and inspected in accordance with the quality control standards of Section 4.2
must be inspected and verified, and in the event of any deviation or deviation from standards in blood and blood products
.
B. All documents and procedures related to the quality of blood products shall be reviewed and approved.
. Review the records regarding blood screening tests and blood product tests, and the contents of the manufacturing records
and must approve the release of blood products in accordance with the release procedures approved by the manufacturing manager
.
d. Whether blood and materials were used, and whether the manufacturing process proceeded, based on the test and inspection results
or determine whether to release the blood product and the result according to a predetermined procedure
The relevant department must be notified.
e. It must be verified whether non-compliant blood or non-compliant materials are being processed in accordance with prescribed procedures.
.
B. Shall oversee matters concerning the handling of complaints and product recalls regarding blood products.
d. shall review and approve the change management of Item 11.
A. The self-inspections under Item 13 shall be planned and implemented on a regular basis.
J. The contractor for testing and inspection and the manufacturer of major materials shall be evaluated.
CHAR. Responsible for storage conditions and storage management of blood, materials, blood products, and specimens for testing and inspection
A user must be specified.
4. Standard
A blood product manufacturer, in order to properly implement blood product manufacturing management and quality control
W Product standards, quality control standards, and manufacturing standards in accordance with the provisions of Sections 4.1 through 4.4
Management Standards and Manufacturing Hygiene Standards must be prepared and kept on file. However, quality
The Management Standards, Manufacturing Standards, and Manufacturing Hygiene Standards may be prepared as a single integrated document.
4.1 Product Standard
Product standards must be prepared for each item and must include the following items:
.
a. Blood product name
B. Date of Approval and Date of Change in Approved Matters
. Efficacy, Effects, Dosage, Administration, and Precautions for Use
d. Matters concerning authorized blood and its quantities, and adjustment of standard quantities where necessary
E. Manufacturing Process Flow Chart and Detailed Manufacturing Methods and Yield Control Standards by Process
Bar. Precautions during operation
Company. Facilities and equipment required for manufacturing management and quality control
A. Standards and Test Methods for Blood, Materials, and Blood Products
. Storage Conditions
. Expiration date or use-by date
Card. History Management
T. Date of creation
H. Manufacturing operation instruction or manufacturing record form containing the following items
1) Product Name
2) Manufacturing number or blood management number, date of manufacture and expiration date or use-by date
3) Test number of blood used, authorized quantity of blood
4) Detailed manufacturing method and precautions during operation
5) Yield Management Standards by Process
6) Sample of marking material
. Other necessary matters
4.2 Quality Control Standards
The Quality Control Standards shall include the following items.
a. Test/Inspection Instruction (Request) Form Including the following items
1) Name of blood product, manufacturing number or blood management number, date of manufacture
2) Test/Inspection Order (Request) Number, Orderer (Requester), and Date of Order (Request)
3) Test and Inspection Items and Standards
B. Collector, quantity, location, and method of collection of specimens for testing and inspection (considering their characteristics
Specimen collection method) and precautions during collection and contamination prevention measures during collection
. Method of notifying relevant departments of test and inspection results
d. Inspection of facilities and equipment for testing and inspection
E. Management of Specimens for Storage
B. Method of sending specimens and method of determining test/inspection results in the case of outsourced testing/inspection
Company. Other detailed standards regarding the fulfillment of the duties of the head of the quality (assurance) department under Section 3.3
etc.
4.3 Manufacturing Control Standard
The Manufacturing Control Standards shall include the following items.
A. Matters concerning manufacturing process control
1) Restriction on access to the workplace
2) Cleanliness of facilities and equipment prior to work
3) Manufacturing Process
4) Confirmation of Marking Material Attachment
5) Method for verifying the suitability of raw materials intended for use
B. Matters concerning facility and equipment management
1) Regular Inspection Method
2) Method for indicating facilities and equipment in operation
3) Measures to be taken in the event of a breakdown or accident
4) Method for Setting Specifications and Calibrating Measuring Instruments
5) Method for Qualifying Critical Machinery and Equipment
. Matters concerning blood management
1) Method for verifying specifications, quantity, and whether packaging containers are damaged upon receipt, and damaged
If so, the processing method
2) Storage Location Light Storage Method
3) Method for Handling Unsuitable Blood Based on Test and Inspection Results
4) Measures to prevent confusion and contamination during handling
5) First-In, First-Out (FIFO) and Labeling Requirements for Containers with Measured Weight or Volume at Shipment
6) Inventory Management
D. Matters concerning material management
1) Method for verifying product name, specifications, quantity, and whether packaging is damaged upon receipt, and if damaged
, the processing method
2) Storage Location and Storage Method
3) Method for Handling Nonconforming Products Based on Test Results
4) Dispensing method and method to verify the quantity of marked materials returned after use
5) Measures to be taken when changing labeling information
6) Measures to prevent confusion and contamination during handling
7) Inventory Management
E. Matters concerning the management of blood products
1) Method for verifying approval judgment during inbound and outbound shipments
2) Storage Location and Storage Method
3) First-In, First-Out (FIFO) Method for Shipment
f. Other detailed standards, etc. related to the fulfillment of the duties of the head of the manufacturing department under Subparagraph 3.2
Requirements
4.4 Manufacturing Hygiene Management Standards
The Manufacturing Hygiene Management Standards shall include the following items.
A. Health management of workers and methods for identifying and addressing their health status
B. Matters concerning hygiene, such as washing and disinfection methods of workers
. Method for cleaning workplaces, etc. (including disinfection if necessary; hereinafter the same) and cleaning instructions
기
d. Detergents or disinfectants and equipment used for cleaning workplaces, etc.
E. Method for Evaluating Cleanliness
B. Matters concerning cleanliness management of workplaces
Company. Cleaning, disinfection, and evaluation of manufacturing facilities (cleaning only where applicable)
1) Designation of Responsible Person
2) Cleaning and Disinfection Plan
3) Cleaning method and detergent or disinfectant used for cleaning and equipment
4) Method for disassembling and assembling manufacturing facilities
5) Method for maintaining cleanliness
6) How to check cleaning status before work
A. Methods to prevent rats, pests, dust, etc., and inspection cycles
In addition, detailed standards, etc. related to the fulfillment of the duties of the manufacturing department head under Section 3.2 must be met.
Required Matters
5. Document
5.1 Document Creation
a. Guidelines and methods pursuant to the standards of subparagraph 4 shall be clearly documented, and m
Matters concerning the management of any document, such as creation, revision, approval, distribution, retrieval, or disposal
must be prepared.
B. Documents must be written in an easy-to-understand manner, and the manufacturing and quality control of blood products and
, the head of the manufacturing department or the head of the quality (assurance) department
Must have a signature and the date of approval.
The author, reviewer (or verifier), and approver of the document must use the signature after registering it.
.
. All record documents regarding the manufacturing and quality control of blood products shall be prepared simultaneously with the work
It must be written in indelible ink. In the event of modifying a record document
Above, draw a line over the character or sentence you want to modify to see the content before modification.
Ensure that the modified document includes the reason for the modification, the date of modification, and the signature of the modifier.
must be present.
E. When revising a document, record the reason for the revision and the date of revision, etc., and the head of the manufacturing department
or the Quality (Assurance) Department, and regularly inspected, and recently
It must be verified whether it has been revised. In this case, the pre-revision version is also preserved for a certain period.
must.
5.2 Document Management
a. Record documents (including electronic records) regarding the manufacture and quality control of blood products are "blood
During the period pursuant to Article 12, Paragraph 2 of the Management Act and Article 14, Paragraph 2 of the Enforcement Rules of the same Act
Must be preserved.
b. In the case of an electronic document system, the blood donor register, etc., electronically in accordance with the "Electronic Signature Act"
It may be created and stored as an electronic document, etc., containing a signature. In this case, the authorized company
can input, modify, or delete output, tape, microfilm, and
Prepare for damage or loss of records using methods such as backup servers, and read them when necessary.
must output in a feasible way.
. Another person's personal information stored in a record document (including electronic records) without justifiable reason
The information must be managed so that it is not detected, leaked, altered, or damaged.
6. Validation
6.1 Validation Target
a. Validation shall be performed in any of the following cases.
1) When manufacturing a new blood product for the first time
2) In the case of installing machinery or equipment that affects the quality of blood products
3) In the case of changing the manufacturing process that affects the quality of blood products
4) When changing the manufacturing environment that affects the quality of blood products
b. Must possess a standard document regarding the implementation of validation, and a comprehensive
A report must be prepared.
. If improvements are required regarding manufacturing management and quality control as a result of conducting validation
, necessary measures must be taken and records regarding said measures must be prepared and kept on file
.
a. As determined by the Minister of Food and Drug Safety, there is objective and reasonable evidentiary data
, validation may be omitted.
6.2 Process Validation
A. Critical processes in the manufacture of blood products (donor selection, blood product manufacturing, blood-mediated infection of donors
Salt factor test, ABO blood typing test, concentrated red blood cell antibody screening test, labeling, storage and
Outgo) consistently manufactures blood products that meet pre-established standards and quality characteristics
shall perform process validation to verify and document.
b. For critical manufacturing processes affecting the quality of blood products, predictive validation
must be performed; however, if unavoidable, it may be substituted with concurrent or retrospective validation.
can do.
. Process validation must be performed for each item.
. Process validation is classified as follows according to the timing of implementation.
1) Predictive Validation
a) Validation performed before the release of blood products, including existing research results,
, factors of variation affecting quality (physical properties of blood and materials, operating conditions
The acceptance conditions of , etc.) must meet the standards.
b) Regarding blood products manufactured three consecutive times at actual production scale for release
perform and analyze, then conduct an overall evaluation. In this case, the blood products manufactured 3 times
components must be compliant.
2) Concurrent Validation
a) Only in cases where predictive validation cannot be performed due to unavoidable circumstances, blood products
As validation performed during manufacturing and shipment, variation factors (blood, material
(Surface characteristics, operating conditions, etc.) must be within acceptable conditions.
b) Regarding blood products manufactured three consecutive times at actual production scale for shipment
perform and analyze, then conduct an overall evaluation. In this case, the blood products manufactured 3 times
components must be compliant.
3) Retrospective Validation
a) Blood manufactured only when the composition, manufacturing process, and facilities and equipment have not been changed
Past manufacturing and quality control records as validation performed for START formulations,
Based on previously accumulated manufacturing and quality control records, such as stability data, statistical
method.
b) Targeting blood products manufactured and sold at actual production scale for 10 to 30 consecutive cycles, actual
and includes manufacturing units that deviated from the standard during that period.
4) Revalidation
Regularly for manufacturing processes or facilities/equipment, etc. that have already been validated
or blood, materials, manufacturing methods, manufacturing that significantly affect the quality of blood products
This shall be implemented when processes, facilities, equipment, etc. are changed.
6.3 Equipment Qualification
a. Qualification of major equipment shall be conducted in accordance with verified procedures.
b. When installing new and refurbished equipment, qualification criteria must be satisfied,
Must be documented and used after the evaluation is completed.
. The scope of qualification for major equipment is determined considering the importance and complexity of the equipment
.
6.4 Test Method Validation
Verifying and documenting the validity of test methods for quality control of blood products in advance
Validation must be carried out for each blood product item.
6.5 Washing Validation
When cleaning of facilities, equipment, etc. is required, verify and document whether they have been properly cleaned
As a validation, it must be performed for each blood product item. However, multiple items simultaneously
When manufacturing multiple items, they may be carried out in a consolidated manner.
6.6 Manufacturing Support Validation
If there are manufacturing support facilities such as a manufacturing water supply system and an air conditioning system, blood
As validation to verify and document the system supporting the manufacture of formulations,
It must be carried out for each installation and piece of equipment.
6.7 Computer System Validation
Accurately analyze, manage, and record data of computer systems and data in accordance with predetermined standards
,
It must be carried out for each installation, equipment, and system.
7. Management of Blood Products by Manufacturing Stage
7.1 Donor Screening
To protect the health of blood donors and prevent the transmission of bloodborne infectious agents, blood donors
Work procedures capable of appropriately selecting START must be established.
7.2 Blood collection
Blood collection shall be carried out in accordance with the "Blood Management Act" at a place equipped with facilities necessary for blood collection under the supervision of the manufacturing manager
Must be carried out.
7.3 Blood Screening Test
a. Blood screening tests shall be performed by a blood product manufacturer or an institution conducting the test
A validated inspection system must be used.
B. Blood test specimens must be collected, labeled, and stored to prevent contamination or deterioration.
must be managed.
7.4 Manufacturing Process Control
A. When manufacturing blood products, a manufacturing record containing the following information must be prepared.
1) Blood Product Name
2) Manufacturing number or blood management number, date of manufacture and expiration date
3) Name of the worker in critical processes, signature of the verifier, date of work and time of work
간
4) Test number or control number of the marking material used
5) Special Notes
b. Entry into the workplace by persons not engaged in the relevant work shall be restricted. However,
Blood donors may enter the blood collection area for blood collection.
. The cleanliness of facilities and equipment must be checked before starting work.
. Manufacture of blood products
Manufacturing methods, standards and test methods, quality control standards, storage conditions and expiration date of blood products
Matters concerning the relationship and other matters shall be in accordance with the Pharmaceutical Affairs Act and the Blood Management Act, with the Minister of Health and Welfare and
It shall be in accordance with the provisions determined and notified by the Minister of Food and Drug Safety.
E. Indicated Material
During the process of attaching labeling materials, verify the presence or absence of abnormalities in the blood product, and appropriate
label, and the
Types and label attachment methods must be standardized.
7.5 Blood Product Test
a. A test report containing the following items shall be prepared for each requested test. c.
Only, the test report shall be prepared or managed by integrating the test request and test instruction forms
can.
1) Name of blood product, manufacturing number or blood management number, date of manufacture
2) Exam Number
3) Date of Receipt, Test, and Judgment
4) Test Items, Test Criteria, Test Results, and Qualification/Non-qualification Results by Item
5) Judgment Result
6) Name of the examiner, signature of the judge, and signature of the interim reviewer
b. All record documents obtained from the examination (including electronic records), such as graphs and calculation formulas,
Must be preserved.
. After collecting a test specimen, it must be indicated that a specimen has been collected.
7.6 Quality (Assurance) Management
a. Only suitable blood, materials, and blood products shall be used or released, and any deviation or
must be processed after investigating the reason. However, 「blood
In cases where ineligible blood may be used pursuant to Article 8, Paragraph 2 of the "Blood Management Act," this shall not apply.
Not.
b. The quality of blood, materials, and blood products is consistently homogeneous and sufficient for test results
Where reliability is guaranteed, necessary items depending on the test items and characteristics of the blood product
may be tested. However, all items must be tested periodically.
. That the test records (including supporting test data) are accurate and meet the established standards
.
. The evaluation for the release approval of blood products involves the comprehensive integration of blood collection, manufacturing, storage, and quality control results.
Must make a judgment by STARTing
E. Test and inspection equipment, measuring instruments, and recorders shall be periodically inspected in accordance with a predetermined plan.
Must correct and record.
B. When collecting blood, collect a separate specimen and store it for at least 10 years under established storage conditions.
Must concern.
Company. By recording the management status of standard samples, specimens, and critical reagents used in testing and inspection
must.
A. Regarding labeling materials, whenever the information is changed, verify compliance with regulations, and the changed labeling
Materials must be stored.
. Packaging materials in contact with blood products that may alter the blood products or be harmful to the human body
Must be used after verifying that it is not a START material.
. When using manufacturing water, testing and evaluation must be performed in accordance with prescribed test methods.
.
7.7 Transport
a. Preventing deterioration of blood products and specimens for testing and examination during transportation and storage
It must be transported at an appropriate temperature to START.
b. Regarding the transportation, intermediate storage (including receipt and supply), and transfer and acceptance of blood products
Procedures must be documented and managed.
7.8 Return
In principle, if blood products are returned, they shall be disposed of. However,
If all of the following conditions are satisfied, the item may be restocked and re-released, and the details thereof
must be recorded and preserved.
1) Where it is confirmed that it was stored under appropriate conditions
2) If the blood storage container (blood bag) is not damaged
3) When the expiration date or use-by date is determined to be sufficient for release for blood transfusion
case
4) In cases where it is confirmed that the test and inspection results comply with quality standards (Test and inspection method
(Excluding cases where release is impossible under the method)
5) Where the return procedure is governed by contract
8. Manufacturing Hygiene Management
8.1 Worker Hygiene
a. Workers must follow appropriate hand disinfection and personal hygiene procedures when collecting blood.
B. When workers enter the workplace, they must wear the prescribed work clothes according to the type of work, new
Shoes, hats, masks, etc. must be worn.
New and current workers must undergo regular medical examinations, and if necessary, appropriate
Ensure proper vaccination.
a. If the quality of blood products or the safety of blood donors is affected due to infectious diseases, etc.
Workers who may come into direct contact with blood donors and blood products until risk factors are eliminated
Must not participate in work that triggers.
8.2 Sanitary Management of Workplaces
a. In order to prevent contamination and confusion, cleanliness is maintained by keeping things well organized.
must.
B. Cleaning shall be carried out in accordance with the regulations regarding cleaning methods, cleaning cycles, and verification methods.
. Bringing food into workspaces and storage areas, smoking, etc., which may affect product quality
You must not perform any acts. However, if necessary, food may be given to the blood donor at the blood collection site.
can provide.
d. Measures to prevent rats, pests, dust, etc. must be prepared, and regular inspections and verifications must be performed
.
8.3 Cleaning and Disinfection of Manufacturing Facilities and Equipment
a. Detergents or disinfectants used for cleaning and disinfecting manufacturing facilities and equipment may not remain or
must be used in a way that does not cause abnormalities to the surface to which it is applied.
b. Maintain cleaned and disinfected manufacturing facilities and equipment so that they are not contaminated until the next use.
ㆍMust manage.
The cleaning and disinfection of manufacturing facilities and equipment involves workers, workdays, and detergents used for cleaning and disinfection.
Cleaning and disinfection records recording disinfectants, etc., and items, etc., using such facilities and equipment or disinfectants, etc.
Records for use must be prepared and kept in chronological order, provided that records of cleaning and disinfection and usage
Records can be created in an integrated manner.
9. Management of Blood, Materials and Blood Products
9.1 Receiving Management
a. Incoming blood shall be kept separate until a suitability judgment is obtained from the test and inspection results after the blood product is manufactured.
It must be stored. However, if it can be clearly distinguished from blood products that have been judged suitable...
This shall not apply if measures are in place.
b. Verify whether the incoming materials are suitable, and until a conformity judgment is made based on the test results
must be stored, and non-conforming materials must be stored separately from conforming materials.
However, measures are in place to clearly distinguish it from materials that have received a conformity judgment.
In such cases, it shall not be so.
. Check the appearance and markings of the incoming blood and materials, and if there is no manufacturing number
Assign a blood management number or material management number to remove dust from the outer packaging
.
a. Collect the necessary amount from the screening specimen collected at the time of blood collection and the manufactured blood product,
Indicate that the test is in progress, and on the specimen container/packaging, the blood management number, collection date, collector, etc.
must be displayed. However, in the case of an automated management system,
The START indicator can be omitted.
9.2 Storage Management
a. Access to the storage facility shall be restricted for persons not engaged in storage duties.
B. Blood, materials, blood products, non-conforming blood, and returned products shall be placed in their respective compartments by type
It must be stored as follows: provided that there is no risk of confusion between blood, materials, and blood products.
shall not apply if stored by the system.
. Blood products and specimens must be stored separately before and after testing or inspection. Materials
must verify whether the material is suitable and separate and store it from non-suitable materials.
However, in the case of an automated management system, markings other than the blood management number may be omitted.
.
d. Store blood, materials, and blood products so they do not touch the floor and walls, and use the First-In, First-Out (FIFO) method.
It must be organized and stored so that it can be shipped via .
E. Blood, blood products, and non-conforming materials determined to be non-conforming shall be marked as such.
It must be distinguished from other blood, blood products, and materials and processed promptly.
B. Blood, materials, blood products, and specimens shall be stored under conditions that do not adversely affect quality
must.
Inc. Labeling materials must be classified and stored by product and type, and in case the labeling content is changed
Measures must be taken at START to prevent mixing with previous materials.
A. Procedures regarding the receipt, processing, and storage of blood and blood products must be prescribed
.
J. Equipped with a device for maintaining the storage temperature and a device for recording the maintained temperature, Period
Correction must be performed systematically.
d. The suitability of blood products must be checked periodically.
K. Use storage equipment or facilities dedicated to blood products equipped with an automatic temperature recording device
Blood products must be stored so that storage conditions, such as temperature, are always maintained.
T. Blood products must be stored without freezing. However, if stored frozen
Blood products that start MTQ1462f16e1aa448df00715 are excluded.
9.3 Shipment Management
a. Shipments must be made using the First-In, First-Out (FIFO) method; otherwise, a valid reason
must be present.
B. Only blood and materials deemed suitable shall be sent to the work site.
. Blood products are blood products available for release according to the release procedures approved by the manufacturing manager
must be released, and the blood product name, manufacturing number or blood management number, release date,
The destination and quantity, etc., must be recorded and managed, and the destination (for unsuitable blood for research purposes)
).
10. Complaint Handling and Product Recall
10.1 Complaint Handling
a. In order to effectively handle complaints regarding blood products, draft complaint handling regulations and
A Complaint Handling Committee must be established and operated.
b. In the event of receiving a complaint from a medical institution or consumer, etc., promptly
to identify the cause, establish measures to prevent recurrence, and provide appropriate
A measure must be taken.
. The complaint handling record must include the following items.
1) Blood Product Name and Blood Management Number
2) Name and contact information of the complainant
3) Date of complaint filing
4) Complaint Details
5) Complaint Handling Results and Actions Taken
d. In the event of a serious defect in a released blood product, take prompt action and maintain the record
Must be maintained, and measures to prevent recurrence must be established and implemented.
10.2 Retrieval
a. To effectively handle the recall of blood products, establish a recall procedure and operate
must.
b. Designate a qualified person within the blood product manufacturing facility to assess the necessity of recalling blood products
shall implement necessary measures and ensure that they are documented.
Recovered items must be isolated and stored, and disposed of in accordance with established regulations. Do not dispose of
If not, it must be clearly marked and isolated/stored.
11. Change Management
A. Facilities, equipment, blood, materials, manufacturing processes, test methods, etc. used in the manufacture of blood products
is changed, the quality process reproducibility, safety, or traceability of blood products
. In this case, sufficient data
, but
If necessary, validation or manufacturer evaluation of materials, etc., must be carried out.
b. When implementing the changes pursuant to subparagraph a, the revision of related documents, and the workers
...must establish and implement necessary measures such as education and training regarding, contract renewal, etc.
.
. After the change pursuant to Item A is completed, an evaluation is conducted to determine if the change is successful and
must determine whether it was effective.
12. Lookback
A procedure to trace from the blood donor to the final recipient and from the final recipient to the blood donor is
It must be documented, and when performing lookback processing, the following items must be observed.
a. The blood provided by a donor later [contains] bloodborne infectious agents through a lookback system
are found to be unsuitable, the past blood obtained from that donor
Unless the liquid has already been discarded due to expiration of the shelf life, etc., do not input it into the process
must be ensured that blood is not collected from the relevant donor for a certain period or permanently
must be ensured that the blood product manufactured from the relevant blood has not already been used
In the event that it is put into additional manufacturing, procedures specifying appropriate measures shall be established.
must.
b. If necessary to ensure the health of the donor and the safety of the blood supply, blood donation
Must notify the person and consult.
If the blood product subject to lookback has already been released, the medical institution from which it was released must be notified.
.
d. If there is a report from the recipient regarding symptoms related to the transfusion suspected to be caused by the transfusion
In accordance with the "Blood Management Act," the relevant medical institution and blood product manufacturer must locate the relevant blood donor
must cooperate to ensure that disease is not transmitted or the recipient is not endangered
from donating,
values must be prepared.
E. Information from blood collection to release must be recorded and maintained, and expired
Ensure the safety of transfusion recipients by taking appropriate and timely measures to prevent blood products from being distributed.
must be provided.
13. Self-inspection
a. A plan has been established and internal manufacturing and quality control are being carried out in accordance with these standards
Regular self-inspections must be conducted to determine whether there are any deviations from standards or product recalls. However, if deviations from standards or product recalls are empty
In special cases, such as frequent occurrences, additional procedures must be performed.
a. Persons capable of conducting self-inspections are manufacturing managers or persons designated by manufacturing managers
, one must be a person with extensive knowledge and experience regarding this standard, and if necessary,
It can be carried out by entrusting it to an external expert.
Self-inspection is conducted by determining the purpose and scope in advance, and after the self-inspection, the results
A report including the department and improvement requirements must be prepared, and regarding the improvement requirements...
The START document must be improved within a set deadline.
14. Education and Training
a. Designating an education manager or person in charge, and education including the content and evaluation of education and training
There must be training regulations, and if necessary, training may be outsourced to external specialized institutions
can.
B. Education and training for workers shall be conducted by establishing an annual plan, and the
In order to effectively perform tasks, according to the relevant tasks Manufacturing and Quality Control and Its
Matters necessary outside of START must be implemented.
. After training, the training results must be evaluated, and retraining must be provided if necessary.
15. Evaluation and Judgment, etc.
15.1 Evaluation
a. Minister of Food and Drug Safety or Head of a Regional Food and Drug Safety Administration (hereinafter referred to as "Regional Head")
evaluates whether the blood products subject to this standard meet this standard.
15.2 Decision
a. The Minister of Food and Drug Safety or the head of a regional office shall, when conducting an evaluation pursuant to Subparagraph 15.1, [refer to] the relevant organization
You may request a review of the submitted materials.
b. The Minister of Food and Drug Safety or the head of a regional office, in order to determine whether it meets these standards, blood
A fact-finding investigation may be conducted on liquid formulation manufacturers.
The evaluation subject is a blood product manufacturing facility licensed under the "Pharmaceutical Affairs Act," and "Blood Management
Pursuant to Article 7-2, Paragraph 2 of the Enforcement Decree of the Act, regarding blood product manufacturers, the Korea Centers for Disease Control and Prevention, etc.
In cases where an evaluation has been received from a government agency and the results have been submitted, in accordance with these standards,
It may be substituted by having received an evaluation.
15.3 Delete <2022. 12. 29.>
15.4 Other
a. The Minister of Food and Drug Safety shall provide guidance and education to specialized educational institutions or organizations regarding these standards
.
b. The Minister of Food and Drug Safety, in order to implement this Standard, [details regarding] the implementation of this Standard
items can be determined.