Annex 2 — 장애인ㆍ고령자 등 주거약자 지원에 관한 법률 시행령
277975 · 2025-10-01
■ Enforcement Decree of the Act on Support for Housing-Vulnerable Persons, Including Persons with Disabilities and the Elderly [Appendix 2] <Amended July 30, 2024>
Standards for the Installation of Convenience Facilities in Housing for the Vulnerable (Related to Article 4)
1. Door handle
a. In the case of housing for the housing vulnerable constructed for the purpose of renting to the housing vulnerable, door handles
Install it so that its center point is located between 0.8m and 0.9m from the floor surface.
must.
a. The handle shape may be lever-type, horizontal or vertical bar-type, etc., which are easy to grip and easy to operate
.
2. Entrance
a. A light equipped with a motion detection sensor must be installed.
a. On the side of the entrance door at a height between 75 and 85 centimeters from the floor
Vertical and horizontal handles must be installed.
3. Living room
a. In the event of an application by the relevant housing vulnerable person or the head of a housing vulnerable household, 1.2 from the floor surface
Install a video intercom at an appropriate location at a height of approximately 1 meter that allows you to view the outside of the entrance, and
must.
b. Where a vulnerable resident is hearing impaired, the new [former name] of the relevant vulnerable resident or the head of the vulnerable resident's household
If there is a window, the lighting brightness of the living room shall be 600 to 900 lux.
4. Kitchen (Limited to cases where there is an application from the relevant housing vulnerable person or the head of a housing vulnerable household)
a. A low-seated sink must be installed.
B. Cooking gas valves must be installed at a height of approximately 1.2 meters from the floor.
5. Bedroom: In cases where the resident with a hearing impairment is using the relevant housing for the vulnerable, the
If there is an application from a housing-vulnerable person or a head of a housing-vulnerable household, the lighting brightness is 300 ? 400 lux
s(lux) will be used.
6. Bathroom
a. In the case of housing for the housing vulnerable constructed for the purpose of renting to the housing vulnerable, the following requirements
All must be satisfied.
1) Install a light equipped with a motion sensor at the bathroom entrance
2) The height of the bathtub shall be 45 centimeters or less from the bathroom floor
3) Install a shower head that can move up and down
4) The bathroom door shall be installed as an outward-opening hinged door, sliding door, or slit door (overlapping door)
Things to do
b. In the event of an application by the relevant housing vulnerable person or the head of a housing vulnerable household, the following conveniences
You must install the system.
1) Height-adjustable washbasin
2) Seated shower facility
3) Towel rack (referring to one installed at a height of approximately 1.2 meters from the floor)