Annex 2 — 제대혈 관리 및 연구에 관한 법률 시행령
273329 · 2025-08-19
■ Enforcement Decree of the Act on the Management and Research of Umbilical Cord Blood [Appendix 2]
Standards for Facilities, Equipment, Personnel, and Quality Management Systems of Cord Blood Banks (Related to Article 11)
1. Facility Standards
a. Air purification required to maintain an environment suitable for the processing and storage of umbilical cord blood
must be equipped with facilities and temperature and humidity control facilities.
B. Classify cord blood processing and storage locations according to work content as follows to ensure hygiene
It must be designated as a controlled area and cleanliness must be maintained.
┌────────┬─────────────────┬──────────┐
│Sanitation Management Area │WorkDetails │Clean Class │
│ │ │Based │
├────────┼─────────────────┼──────────┤
│1) Sterile Zone │Umbilical cord blood or direct contact with umbilical cord blood │100 or less │
│ │is where reagents and equipment within the work area │ │
│ │Operation in contact with the machine │ │
├────────┼─────────────────┼──────────┤
│2) Clean Zone(Undress│Umbilical cord blood or direct contact with umbilical cord blood │100,000 or less │
│includes thread) │is where reagents and equipment within the work area │ │
│ │Operation without contact with the machine │ │
├────────┼─────────────────┼──────────┤
│3) General Work Area │Liquid nitrogen tank for umbilical cord blood storage and its │- │
│ │Storage of materials outside, etc. │ │
└────────┴─────────────────┴──────────┘
2. Equipment Standard
In accordance with the classification of the scope of business of a cord blood bank pursuant to Article 11, Paragraph 3, the following equipment
must be equipped.
┌──────────┬──────────────────────────┐
│ScopeOfWork │Equipment │
├──────────┼──────────────────────────┤
│a. Article 11, Paragraph 3, Subparagraph 1│1) Programmable refrigerator or ultra-low temperature refrigerator │
│ │2) Device for plastic sealing │
│ │3) Sterile tube connector and syringe pump (Syringe │
│ │Pump) etc. │
│ │4) Clean Bench │
│ │5) Refrigerated Centrifuge │
│ │6) Plasma extractor │
│ │7) Electronic Scale (Digital Balance) │
│ │8) Microscope and Cell Count Chamber │
│ │9) Constant temperature bath │
│ │10) Freezer for specimen storage │
│ │11) Liquid nitrogen tank for cord blood storage │
│ │12) Liquid Nitrogen Transport Container for Transporting Frozen Umbilical Cord Blood │
├──────────┼──────────────────────────┤
│B. Article 11, Paragraph 3, Subparagraph 2│1) Freezer for specimen storage │
│ │2) Liquid nitrogen tank for cord blood storage │
│ │3) Liquid Nitrogen Transport Container for Transporting Frozen Umbilical Cord Blood │
├──────────┴──────────────────────────┤
│Remarks │
│ 1. The equipment shall not be used for any purpose other than cord blood management. │
│ 2. Freezers for specimen storage and liquid nitrogen tanks for cord blood storage continuously temperature │
│, an alarm device for temperature changes, and equipment for preparing for power outages │
│must be equipped. │
└─────────────────────────────────────┘
3. Manpower Standards
Full-time personnel in accordance with each of the following items must be employed.
a. One or more medical officers
b. Pursuant to Article 2 of the "Act on Medical Technicians, etc." responsible for umbilical cord blood testing services
At least one clinical pathologist
...is responsible for business cooperation with external organizations, information management, and record management of the cord blood bank.
has 1 or more administrative managers
4. Quality Management System Standards
To ensure the quality control and safety of cord blood, including the contents of each of the following items
A quality management system must be established, documented, and maintained.
a. Organizational chart and division of duties for personnel including the head of the cord blood bank
B. Qualification requirements for employees performing cord blood management duties and the job suitability of the relevant personnel
Training content and evaluation methods for maintaining character
. Matters concerning specifications, performance inspection, and maintenance of facilities and equipment
d. Matters concerning the enactment and amendment of cord blood bank regulations and cord blood management operational guidelines
E. Matters concerning quality control
B. Matters concerning the maintenance and retention period, etc. of documents and records
Company. Matters concerning inspection standards and inventory management of goods and reagents
A. Matters concerning the prevention of safety accidents
J. Regarding the storage and transportation, etc. of cord blood in storage in the event of a disaster or calamity
Instructions
D. Response Guidelines for the Preservation of Data, Facilities, and Equipment in the Event of Disasters, etc.