Annex 2 — 지진ㆍ화산재해대책법 시행령

277781 · 2025-10-01

■ Enforcement Decree of the Earthquake and Volcanic Disaster Countermeasures Act [Appendix 2] <Amended Jan. 5, 2021> Installation Standards for Observation Facilities and Equipment (Related to Article 4, Paragraph 1) 1. Installation Standards for Earthquake Observation Facilities and Observation Equipment a. Installation Location 1) As a principle, observation equipment should be installed on bedrock on the ground where background noise is low However, in areas with high background noise, borehole seismometers can be installed. . 2) Areas located nearby that generate noise, such as busy roads must be installed avoiding it. 3) If the installation location is within the area of ​​the facility under observation, if possible, background Install observation equipment in a low-noise location. 4) It must be a place that can represent the ground motion of that region. 5) Consultation of observation agencies regarding earthquakes, tsunamis, and volcanic activity from neighboring seismic stations It must be located at a distance equal to the separation distance determined by the committee. However, if the installation location is... within the area of ​​the target facility or necessary for specific research purposes The above is an exception. 6) The safety of the observation facility is guaranteed, and access for the maintenance and management of observation equipment It must be a place with good START. 7) It must be a location with few obstacles that could affect earthquake observation. B. Buildings/Facilities 1) Seismic observatories are designed to protect observation facilities from the external environment, so as to be external and It shall be a shielded building or structure and shall be equipped with lightning protection facilities. The interior of the station shall be divided into a sensor room for installing seismometers and a recording room, wherein the sensor room and The record room can be separated and installed separately. 2) The sensor room shall be a flat concrete structure connected to the underground bedrock, and so that vibrations of buildings or structures, including the lock room, cannot be directly transmitted Install it at a sufficiently distant location, and if a speedometer observation sensor is installed, Equipped with a mounting stand wide enough to install speedometer and accelerometer observation sensors must be, and four directions must be marked on the surface. In the record room, shelves or 3) are provided to record or store earthquake observation data. Install the box by fixing it to the ground surface, and mount it so that an observer can enter and exit. A space sufficient for the installation of electrical, telecommunications, and other auxiliary equipment must be secured. must. 4) Seismic observatories are installed in the recording room to receive standard time and location information is the 4 Open at least 3/3 of the way and ensure there are no obstacles in the surroundings. At earthquake observation stations, boundary fences shall be installed if necessary, considering the surrounding observation environment. Install. . Observation equipment The seismograph consists of an observation sensor, a data collection and processing device, and a power supply, and the observation Sensors are classified into speedometers and accelerometers, and surface, borehole, and seafloor seismometers, etc. Install according to the observation environment. 2) The observation sensor shall be installed horizontally on the surface of the mounting stand in the sensor room, and North-South The directional sensor is installed aligned with True North, and the east-west direction sensor is Installed aligned with the east side, and the accelerometer observation sensor is fixed to the floor. must be done. 3) The seismograph is set to operate for more than 1 hour in preparation for a general power outage It must be equipped with an uninterruptible power supply capable of performing and recording earthquake observations. 2. Installation Standards for Tsunami Observation Facilities and Equipment a. Installation Location 1) The installation site must be a location where changes in the height of approaching tsunamis can be observed. 2) The installation site must not be a landfill area, the ground must be solid, and runoff from the river refers to sediments accumulated due to the influence of sediment, tides, or waves . 3) Where the installation site is on the seabed, the navigation of vessels such as fishing boats affects the observation It must be a place with little scent. 4) The safety of observation facilities is guaranteed, and accessibility for the maintenance and management of observation equipment This must be a good place. 5) It must be a location with few obstacles that could affect tsunami observation. B. Buildings & Facilities 1) Tsunami observation stations must be protected from wind and salt, and lightning protection facilities must be equipped. 2) The wave gauge mounting stand can support the weight of the tsunami wave gauge and the stand itself Made of sturdy and corrosion-resistant material to withstand external impacts or harsh weather It must be installed by fixing it in place so that it can withstand the , etc. 3) When installed on the seabed, the wave gauge mounting stand moves due to currents, waves, etc. Install so that the underwater cable is not damaged by currents, waves, etc. Install it as follows, and mark the installation location for protection. Tsunami observation stations should erect alerts as needed, taking into account the surrounding observation environment. Install the trolley. 5) Closed-circuit television as needed for continuous monitoring of tsunamis Install (CCTV). . Observation equipment 1) The tsunami wave height gauge consists of an observation sensor, a data collection and processing device, and a power supply unit and install observation sensors according to the observation environment, such as ultrasonic or pressure types. The observation sensor of the tsunami wave height gauge must be installed vertically to the sea surface, and the external The sensor support does not vibrate or deform due to shock or rough weather, etc. . 3) The tsunami wave height gauge observation sensor must be protected from submersion or corrosion . 4) The tsunami wave height gauge is prepared for the event of a general power interruption 1 time must be equipped. 3. Installation Standards for Volcanic Activity Observation Facilities and Equipment of volcanic earthquake observation facilities and observation equipment installed for the purpose of observing volcanic activity Regarding the installation standards, Item 1 shall apply mutatis mutandis.