Annex 3 — 방송통신설비의 기술기준에 관한 규정
263865 · 2024-07-19
■ Regulations on Technical Standards for Broadcasting and Telecommunications Facilities [Appendix 3] <Amended Dec. 6, 2022>
Standards for Securing In-premises Telecommunications Room Area in Multi-unit Housing, Quasi-residential Housing, and Officetels (Related to Article 19, Subparagraphs 2 and 3)
┏━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━┓
┃Section │Secured Area ┃
┠───────────────────┼────────────────────┨
┃ 1. Complexes with 50 to 500 households │1 location of 10 square meters or more ┃
┠───────────────────┼────────────────────┨
┃ 2. Complexes with over 500 households and up to 1,000 households │1 location of 15 square meters or more ┃
┠───────────────────┼────────────────────┨
┃ 3. Complexes with over 1,000 households and up to 1,500 households│1 location of 20 square meters or more ┃
┠───────────────────┼────────────────────┨
┃ 4. Complexes exceeding 1,500 households │1 location of 25 square meters or more ┃
┗━━━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━┛
Remarks
1. The centralized in-building communications room must be located on the ground floor with minimal impact from the external environment. However,
In cases where securing the ground is difficult due to unavoidable circumstances, if there is no risk of flooding and moisture...
It can be installed in a basement floor that is not [unclear].
2. The centralized in-building communications room must be equipped with lighting facilities and power supply facilities dedicated to communications equipment.
.
3. The area of each communication room shall be the area excluding walls, pillars, etc.
4. A locking device must be installed at the entrance of the centralized internal communications room.