Annex 7 — 건설기계 안전기준에 관한 규칙
234965 · 2021-08-27
■ Rules on Safety Standards for Construction Machinery [Appendix 7] <Newly Added 2013.5.27>
Protection of Operators of Earthmoving Construction Machinery (Related to Section 149-5)
┌────────────────────────────────────────────────┐
│1. Test Method and Standard for Overturning Protection Structure of Earthwork Construction Machinery │
├────────────────────────────────────────────────┤
│┌──────────────────────────────────────────────┐│
││A. Test Specimen: Overturning Protection Structure ││
││Na. Jo Gun: Transverse energy and force, longitudinal energy, vertical load Fill ││
││specifications, KS F ISO 3471 (Earthworking Machinery - Overturning Protection Structure - Testing and Performance Required ││
││item). ││
││. Above Value: Location where energy and load can be effectively transferred to the overturn protection structure ││
││ra. Bang START method: Pushing the test specimen in each direction using a pressurizing device, transverse, longitudinal, and lengthwise directions ││
││. However, the specimens shall be identical, and the speed of the test device shall be 5mm/s ││
││must not be exceeded. ││
││E. Acceptance Conditions: The following conditions must be satisfied. ││
││ 1) Satisfying the absorbed energy and load of the test conditions, and the rollover protection structure enters the DLV ││
││should not. ││
││ 2) Rollover Protection Structures (ROPS) shall be used for construction machinery due to frame or mounting defects, etc. of construction machinery ││
││Must not be separated from the frame. ││
│└──────────────────────────────────────────────┘│
├────────────────────────────────────────────────┤
│ │
│2. Test Methods and Standards for Falling Object Protection Structures of Earthwork Construction Machinery │
├────────────────────────────────────────────────┤
│┌────────────────────────────────────────────┐ │
││a. Test specimen: The material shall be steel or wrought iron, and the contact surface shall be spherical with a diameter of 250 mm or less. │ │
││must. │ │
││B. Conditions (Table): Category 1 is a height and mass (3m, 46kg) satisfying an impulse of 1365J, and Category 2 is │ │
││The height and mass (5.2m, 227kg) satisfy an impulse of 600J. │ │
││. Above Value: Within the vertical projection range of the DLV upper horizontal area, the most [value] of the DLV and upper guard │ │
││It is the center of the most vulnerable area among the close regions. │ │
││ra. Bang Method: Conduct one test in a stationary state under the above conditions. │ │
││E. Acceptance Condition: Satisfies the absorbed energy of the test conditions, and the upper guard structure enters the DLV. │ │
││must not be penetrated. If the upper guard is penetrated, the test shall be considered a failure. │ │
│└────────────────────────────────────────────┘ │
├────────────────────────────────────────────────┤
│ │
│ Condition(Table) │
│┌───┬──────────────────┬──────────────────┐ │
││ │Category 1 │Category 2 │ │
│├───┼──────────────────┼──────────────────┤ │
││Impact│1365J │11600J │ │
│├───┼──────────────────┼──────────────────┤ │
││Range │Bricks, small concrete pieces and high speed │Obstacle removal, elevated dismantling or forest site │ │
││ │Maintenance/Groundwork/Other Construction via START │heavy trees or rocks falling from the field │ │
││ │Hand tools required for field service work │Amount Level of protection against falling objects │ │
││ │등의 작은 낙하물로부터 보호할 수 있 │ │ │
││ │is level │ │ │
│└───┴──────────────────┴──────────────────┘ │
└────────────────────────────────────────────────┘
※ The category shall be a structure capable of withstanding the impact amount according to the range.