Annex 7 — 건설기계 안전기준에 관한 규칙

234965 · 2021-08-27

■ Rules on Safety Standards for Construction Machinery [Appendix 7] <Newly Added 2013.5.27> Protection of Operators of Earthmoving Construction Machinery (Related to Section 149-5) ┌────────────────────────────────────────────────┐ │1. Test Method and Standard for Overturning Protection Structure of Earthwork Construction Machinery │ ├────────────────────────────────────────────────┤ │┌──────────────────────────────────────────────┐│ ││A. Test Specimen: Overturning Protection Structure ││ ││Na. Jo Gun: Transverse energy and force, longitudinal energy, vertical load Fill ││ ││specifications, KS F ISO 3471 (Earthworking Machinery - Overturning Protection Structure - Testing and Performance Required ││ ││item). ││ ││. Above Value: Location where energy and load can be effectively transferred to the overturn protection structure ││ ││ra. Bang START method: Pushing the test specimen in each direction using a pressurizing device, transverse, longitudinal, and lengthwise directions ││ ││. However, the specimens shall be identical, and the speed of the test device shall be 5mm/s ││ ││must not be exceeded. ││ ││E. Acceptance Conditions: The following conditions must be satisfied. ││ ││ 1) Satisfying the absorbed energy and load of the test conditions, and the rollover protection structure enters the DLV ││ ││should not. ││ ││ 2) Rollover Protection Structures (ROPS) shall be used for construction machinery due to frame or mounting defects, etc. of construction machinery ││ ││Must not be separated from the frame. ││ │└──────────────────────────────────────────────┘│ ├────────────────────────────────────────────────┤ │ │ │2. Test Methods and Standards for Falling Object Protection Structures of Earthwork Construction Machinery │ ├────────────────────────────────────────────────┤ │┌────────────────────────────────────────────┐ │ ││a. Test specimen: The material shall be steel or wrought iron, and the contact surface shall be spherical with a diameter of 250 mm or less. │ │ ││must. │ │ ││B. Conditions (Table): Category 1 is a height and mass (3m, 46kg) satisfying an impulse of 1365J, and Category 2 is │ │ ││The height and mass (5.2m, 227kg) satisfy an impulse of 600J. │ │ ││. Above Value: Within the vertical projection range of the DLV upper horizontal area, the most [value] of the DLV and upper guard │ │ ││It is the center of the most vulnerable area among the close regions. │ │ ││ra. Bang Method: Conduct one test in a stationary state under the above conditions. │ │ ││E. Acceptance Condition: Satisfies the absorbed energy of the test conditions, and the upper guard structure enters the DLV. │ │ ││must not be penetrated. If the upper guard is penetrated, the test shall be considered a failure. │ │ │└────────────────────────────────────────────┘ │ ├────────────────────────────────────────────────┤ │ │ │ Condition(Table) │ │┌───┬──────────────────┬──────────────────┐ │ ││ │Category 1 │Category 2 │ │ │├───┼──────────────────┼──────────────────┤ │ ││Impact│1365J │11600J │ │ │├───┼──────────────────┼──────────────────┤ │ ││Range │Bricks, small concrete pieces and high speed │Obstacle removal, elevated dismantling or forest site │ │ ││ │Maintenance/Groundwork/Other Construction via START │heavy trees or rocks falling from the field │ │ ││ │Hand tools required for field service work │Amount Level of protection against falling objects │ │ ││ │등의 작은 낙하물로부터 보호할 수 있 │ │ │ ││ │is level │ │ │ │└───┴──────────────────┴──────────────────┘ │ └────────────────────────────────────────────────┘ ※ The category shall be a structure capable of withstanding the impact amount according to the range.