Annex 4 — 건설기계 안전기준에 관한 규칙

234965 · 2021-08-27

■ Rules on Safety Standards for Construction Machinery [Appendix 4-2] <Amended Aug. 27, 2021> Standards for Insulation Safety, etc. of High Power Electrical Devices (Related to Article 133-2, Paragraph 1) 1. The live conductor part of a high-voltage electrical device shall comply with the standards of each of the following subparagraphs. a. The protective mechanism of the live conductor part cannot be opened, disassembled, or removed without the use of tools. . b. Live conductors within the cockpit must not be directly contacted during IPXXD access. . Live conductor parts, excluding item (b), must not be directly contacted during IPXXB access. 2. Connector of a high-voltage electrical device (including a charging connector of a hydrogen fuel cell construction machine. The "high-voltage connector" (hereinafter referred to as "high-voltage connector") must satisfy Subparagraphs (b) and (c) of Item 1. However, (c) Cases falling under any of the following subparagraphs are excluded. a. In the case where the high-voltage connector is located on the exterior floor surface of the vehicle body and has a locking mechanism or. If the high-voltage connector has a locking mechanism and to disconnect the high-voltage connector, a tool , then . Within 1 second after disconnecting the high-voltage connector, the voltage is DC 60 volts or AC 30 If it falls below the bolt 3. High-voltage circuit breakers for the inspection and repair of high-voltage electrical equipment do not use tools In the case of a structure that can be opened, disassembled, or removed without direct contact during IPXXB access must not be. 4. The exterior or protective devices of high-voltage electrical equipment shall comply with the standards of each of the following items A warning indication must be placed on the high-voltage connector and on the exterior floor surface of the vehicle body. However, the warning indication must be placed on the high-voltage connector and on the exterior floor surface of the vehicle body. A protective mechanism is positioned so that high-voltage electrical equipment is not easily accessed, opened, or removed. This shall not apply in cases where there is. a. The warning indications are as follows. Color: Background is yellow, image and outlines are black a. Warning signs shall be marked in a identifiable manner and shall not easily fade or be erased must. . In the case of the drive battery, a warning sign must be attached to the top or surrounding area. 5. Electrical wiring between high-voltage electrical devices (excluding cases located inside protective devices) The coating must be orange. 6. Exposed electrically conductive parts of high-voltage electrical equipment protection mechanisms are protected by wiring, welding, bolts, etc. method, and exposed electrical conductors and electrical The resistance between chassis must be less than 0.1Ω. 7. The insulation resistance between the live conductor and the electrical chassis of a high-voltage electrical device shall be as per each of the following items Must comply with the START standard. a. When the DC circuit and the AC circuit are configured independently, the insulation resistance is 100Ω each. /V(DC), 500Ω/V(AC) or higher. b. In cases where DC and AC circuits are electrically combined, the insulation resistance is 500 Ω/V. However, if the AC circuit satisfies any of the following subparagraphs , it can be made 100Ω/V or higher. 1) The protective mechanism of the high-voltage electrical device is insulated with double or more insulators inside, and If subparagraph 6 is satisfied 2) Drive motor housing, power converter external box, high-voltage connector, etc. mechanical In the case of a structurally robustly mounted structure The high-voltage DC circuit of hydrogen fuel cell construction machinery shall have an insulation resistance of 100Ω/V or less. Equipped with an insulation resistance monitoring system to warn the operator in case of drop. should. ra. Between the live conductor part of the hydrogen fuel cell construction machinery charging connector and the electrical chassis The insulation resistance must be at least 1 MΩ. 8. To charge the drive battery of a hydrogen fuel cell construction machine, an external power source (charging voltage and current) before grounding of hydrogen fuel cell construction machinery and external charging device First, it must be connected and maintained until the external power is disconnected, and the drive capacitor The hydrogen fuel cell construction machine must not be operated while charging. Remarks 1. IPXXB refers to the International Protection Class (IEC 60529) specified in the It refers to a finger model used to verify finger access safety. 2. IPXXD: International Protection Class specified in the Code (IEC 60529) Refers to a wire model for verifying wire access safety. 3. An electric chassis refers to the electrically conductive part of the hydrogen fuel cell construction machine body says.