Annex 2 — 건설기계 안전기준에 관한 규칙

234965 · 2021-08-27

■ Rules on Safety Standards for Construction Machinery [Appendix 2] <Amended July 31, 2020> Protection and rescue of excavator operators (related to Article 12-6) 1. Test Methods and Standards for Falling Object Protection Guards of Excavators ┌─────────────────────────────────────────────┐ │A. Upper guard impact test (drop), (FOG : Falling Object Guard) │ │ 1) Test specimen: The material shall be steel or wrought iron, and the contact surface shall be spherical with a diameter of 250 mm or less │ │. │ │ 2) Condition (Table): Level 1 is a height and mass (3m, 46kg) satisfying an impulse of 1365J, and Level 2 is │ │11600J . │ │ 3) Location: Within the vertical projection range of the DLV's upper horizontal area, the closest point between the DLV and the upper guard │ │It is the center of the most vulnerable area among the START regions. │ │ 4) Method: Conduct one test in a stationary state under the above conditions. │ │ 5) Acceptance Condition: Satisfies the absorbed energy of the test conditions, and the upper guard structure enters the DLV │ │Must not proceed. If the upper guard is penetrated, the test shall be considered a failure. │ │B. Front Guard Impact Test │ │ 1) Test specimen: The material shall be steel, and the contact surface shall be spherical with a diameter of 260 mm or less. │ │ 2) Condition (Table): Using a pressurizing device that pushes the specimen toward the front guard, Level 1 700J, Level 2 5800J │ │must satisfy. │ │ 3) Position: Within the horizontal projection range of the DLV's forward horizontal area, the nearest point between the DLV and the front guard │ │It is the center of the most vulnerable area among the START regions. │ │ 4) Method: During the test, the speed of each device shall not exceed 5 mm/s. │ │ Acceptance condition: Satisfies the absorbed energy of the test conditions, and the front guard structure enters the DLV │ │must not be penetrated. If the upper guard is penetrated, the test shall be considered a failure. │ ├─────────────────────────────────────────────┤ │ Condition(Table) │ │┌─────┬────────┬────────┐ │ ││ │Level 1 │level 2 │ │ │├─────┼────────┼────────┤ │ ││Upper Guard │1365J │11600J │ │ │├─────┼────────┼────────┤ │ ││Front Guard │700J │5800J │ │ │├─────┼────────┼────────┤ │ ││ │Excavator under 6 tons │Excavator exceeding 6 tons │ │ │└─────┴────────┴────────┘ │ └─────────────────────────────────────────────┘ 2. Test Methods and Standards for Overturning Protection Structures of Excavators (Applicable to Operating Weight 6,000 kg or Less) ┌────────────────────────────────────────────┐ │A. Test Specimen: Conductive Protection Structure │ │Na. Jo Gun: The energy required in the lateral direction follows the measurement formula below. │ │ │ │ │ │ m: Manufacturer's maximum recommended weight (kg) │ │ Unit : J (Joule) │ │ │ │. Above Value: Location where energy can be effectively transferred to the conductive protection structure │ │ra. Bang START method: Push the test specimen in the lateral direction using a pressurizing device, and the speed of the test device is 5 mm/s │ │must not exceed. │ │E. Acceptance Conditions: The following conditions must be satisfied. │ │ 1) Satisfying the required energy absorption of the test conditions, and the conductive protective structure enters within the deformation limit volume │ │should not go. │ │ 2) Tip-Over Protective Structure (TOPS) is the upper slewing body of construction machinery │ │. │ └────────────────────────────────────────────┘ 3. Test Methods and Standards for Overturning Protection Structures of Excavators (Applicable to Operating Weights Exceeding 6,000 kg) ┌────────────────────────────────────────────┐ │A. Test Specimen: Overturned Protection Structure │ │Na. Jo : Transverse energy and force, longitudinal energy, vertical load │ │The following details refer to the energy or load (with or without cap riser) according to the formulas in Table 1 and Table 2, depending on the specifications │ │. │ │. Above Value: Location where energy and load can be effectively transferred to the overturn protection structure │ │ra. Bang START method: Pushing the test specimen in each direction using a pressurizing device, transverse, longitudinal, and long │ │It shall be performed in the order of this direction. However, the specimens shall be identical specimens, and the speed of the test device │ │Must not exceed 5mm/s. │ │E. Acceptance Conditions: The following conditions must be satisfied. │ │ 1) Satisfy the absorbed energy and load of the test conditions, and the rollover protection structure does not enter the DLV │ │shouldnot. │ │ Roll-Over Protective Structures (ROPS) are construction machinery frames or ma │ │It must not be separated from the frame of the construction machine due to a mounting defect. │ ├────────────────────────────────────────────┤ │Table 1 Equipment without cap risers - Determination formula │ │┌─────────────┬──────────┐ │ ││Lateral Load Energy Us (J)│13000ㆍ(m/10000)1.25│ │ │├─────────────┼──────────┤ │ ││Transverse Load Force Fs (N) │35000ㆍ(m/10000)1.2 │ │ │├─────────────┼──────────┤ │ ││Longitudinal Load Energy Uf (J)│4300ㆍ(m/10000)1.25 │ │ │├─────────────┼──────────┤ │ ││Vertical Load Force Fv (N) │12.75m │ │ │└─────────────┴──────────┘ │ │ │ ├────────────────────────────────────────────┤ │Table 2. Equipment with Cap Riser - Determination Formula │ │┌─────────┬────────┬─────────┬────────────┐ │ ││ │500 mm or less daytime│500 mm or more and │Height of 1300 mm or more │ │ ││ │is the cap riser │Less than 1300 mm │is Cap Riser (TOPS) │ │ ││ │ │Interval height cap riser │ │ │ │├─────────┼────────┼─────────┼────────────┤ │ ││Transverse load energy │13000ㆍ │13000ㆍ │13000ㆍ │ │ ││Us (J) │(m/10000)1.25 │(m/10000)1.25 │(m/10000)1.25 │ │ │├─────────┼────────┼─────────┼────────────┤ │ ││Transverse Load Force Fs │35000ㆍ │50000ㆍ │50000ㆍ │ │ ││(N) │(m/10000)1.2 │(m/10000)1.2 │(m/10000)1.2 │ │ │├─────────┼────────┼─────────┼────────────┤ │ ││Longitudinal load energy │4300ㆍ │4300ㆍ │4300ㆍ │ │ ││Uf (J) │(m/10000)1.25 │(m/10000)1.25 │(m/10000)1.25 │ │ │├─────────┼────────┼─────────┼────────────┤ │ ││Vertical Load Force Fv │12.75m │19.61m │7m │ │ ││(N) │ │ │ │ │ │├─────────┴────────┴─────────┴────────────┤ │ ││Remarks. Overturning of excavators equipped with cap risers requires further study. The manufacturer [assists] the risk │ │ ││Considering the requirements for cap riser height based on good engineering practices and knowledge │ │ ││must determine the protection to be provided. │ │ │└─────────────────────────────────────────┘ │ │ │ └────────────────────────────────────────────┘