Annex 2 — 건설기계 안전기준에 관한 규칙
234965 · 2021-08-27
■ Rules on Safety Standards for Construction Machinery [Appendix 2] <Amended July 31, 2020>
Protection and rescue of excavator operators (related to Article 12-6)
1. Test Methods and Standards for Falling Object Protection Guards of Excavators
┌─────────────────────────────────────────────┐
│A. Upper guard impact test (drop), (FOG : Falling Object Guard) │
│ 1) Test specimen: The material shall be steel or wrought iron, and the contact surface shall be spherical with a diameter of 250 mm or less │
│. │
│ 2) Condition (Table): Level 1 is a height and mass (3m, 46kg) satisfying an impulse of 1365J, and Level 2 is │
│11600J . │
│ 3) Location: Within the vertical projection range of the DLV's upper horizontal area, the closest point between the DLV and the upper guard │
│It is the center of the most vulnerable area among the START regions. │
│ 4) Method: Conduct one test in a stationary state under the above conditions. │
│ 5) Acceptance Condition: Satisfies the absorbed energy of the test conditions, and the upper guard structure enters the DLV │
│Must not proceed. If the upper guard is penetrated, the test shall be considered a failure. │
│B. Front Guard Impact Test │
│ 1) Test specimen: The material shall be steel, and the contact surface shall be spherical with a diameter of 260 mm or less. │
│ 2) Condition (Table): Using a pressurizing device that pushes the specimen toward the front guard, Level 1 700J, Level 2 5800J │
│must satisfy. │
│ 3) Position: Within the horizontal projection range of the DLV's forward horizontal area, the nearest point between the DLV and the front guard │
│It is the center of the most vulnerable area among the START regions. │
│ 4) Method: During the test, the speed of each device shall not exceed 5 mm/s. │
│ Acceptance condition: Satisfies the absorbed energy of the test conditions, and the front guard structure enters the DLV │
│must not be penetrated. If the upper guard is penetrated, the test shall be considered a failure. │
├─────────────────────────────────────────────┤
│ Condition(Table) │
│┌─────┬────────┬────────┐ │
││ │Level 1 │level 2 │ │
│├─────┼────────┼────────┤ │
││Upper Guard │1365J │11600J │ │
│├─────┼────────┼────────┤ │
││Front Guard │700J │5800J │ │
│├─────┼────────┼────────┤ │
││ │Excavator under 6 tons │Excavator exceeding 6 tons │ │
│└─────┴────────┴────────┘ │
└─────────────────────────────────────────────┘
2. Test Methods and Standards for Overturning Protection Structures of Excavators (Applicable to Operating Weight 6,000 kg or Less)
┌────────────────────────────────────────────┐
│A. Test Specimen: Conductive Protection Structure │
│Na. Jo Gun: The energy required in the lateral direction follows the measurement formula below. │
│ │
│ │
│ m: Manufacturer's maximum recommended weight (kg) │
│ Unit : J (Joule) │
│ │
│. Above Value: Location where energy can be effectively transferred to the conductive protection structure │
│ra. Bang START method: Push the test specimen in the lateral direction using a pressurizing device, and the speed of the test device is 5 mm/s │
│must not exceed. │
│E. Acceptance Conditions: The following conditions must be satisfied. │
│ 1) Satisfying the required energy absorption of the test conditions, and the conductive protective structure enters within the deformation limit volume │
│should not go. │
│ 2) Tip-Over Protective Structure (TOPS) is the upper slewing body of construction machinery │
│. │
└────────────────────────────────────────────┘
3. Test Methods and Standards for Overturning Protection Structures of Excavators (Applicable to Operating Weights Exceeding 6,000 kg)
┌────────────────────────────────────────────┐
│A. Test Specimen: Overturned Protection Structure │
│Na. Jo : Transverse energy and force, longitudinal energy, vertical load │
│The following details refer to the energy or load (with or without cap riser) according to the formulas in Table 1 and Table 2, depending on the specifications │
│. │
│. Above Value: Location where energy and load can be effectively transferred to the overturn protection structure │
│ra. Bang START method: Pushing the test specimen in each direction using a pressurizing device, transverse, longitudinal, and long │
│It shall be performed in the order of this direction. However, the specimens shall be identical specimens, and the speed of the test device │
│Must not exceed 5mm/s. │
│E. Acceptance Conditions: The following conditions must be satisfied. │
│ 1) Satisfy the absorbed energy and load of the test conditions, and the rollover protection structure does not enter the DLV │
│shouldnot. │
│ Roll-Over Protective Structures (ROPS) are construction machinery frames or ma │
│It must not be separated from the frame of the construction machine due to a mounting defect. │
├────────────────────────────────────────────┤
│Table 1 Equipment without cap risers - Determination formula │
│┌─────────────┬──────────┐ │
││Lateral Load Energy Us (J)│13000ㆍ(m/10000)1.25│ │
│├─────────────┼──────────┤ │
││Transverse Load Force Fs (N) │35000ㆍ(m/10000)1.2 │ │
│├─────────────┼──────────┤ │
││Longitudinal Load Energy Uf (J)│4300ㆍ(m/10000)1.25 │ │
│├─────────────┼──────────┤ │
││Vertical Load Force Fv (N) │12.75m │ │
│└─────────────┴──────────┘ │
│ │
├────────────────────────────────────────────┤
│Table 2. Equipment with Cap Riser - Determination Formula │
│┌─────────┬────────┬─────────┬────────────┐ │
││ │500 mm or less daytime│500 mm or more and │Height of 1300 mm or more │ │
││ │is the cap riser │Less than 1300 mm │is Cap Riser (TOPS) │ │
││ │ │Interval height cap riser │ │ │
│├─────────┼────────┼─────────┼────────────┤ │
││Transverse load energy │13000ㆍ │13000ㆍ │13000ㆍ │ │
││Us (J) │(m/10000)1.25 │(m/10000)1.25 │(m/10000)1.25 │ │
│├─────────┼────────┼─────────┼────────────┤ │
││Transverse Load Force Fs │35000ㆍ │50000ㆍ │50000ㆍ │ │
││(N) │(m/10000)1.2 │(m/10000)1.2 │(m/10000)1.2 │ │
│├─────────┼────────┼─────────┼────────────┤ │
││Longitudinal load energy │4300ㆍ │4300ㆍ │4300ㆍ │ │
││Uf (J) │(m/10000)1.25 │(m/10000)1.25 │(m/10000)1.25 │ │
│├─────────┼────────┼─────────┼────────────┤ │
││Vertical Load Force Fv │12.75m │19.61m │7m │ │
││(N) │ │ │ │ │
│├─────────┴────────┴─────────┴────────────┤ │
││Remarks. Overturning of excavators equipped with cap risers requires further study. The manufacturer [assists] the risk │ │
││Considering the requirements for cap riser height based on good engineering practices and knowledge │ │
││must determine the protection to be provided. │ │
│└─────────────────────────────────────────┘ │
│ │
└────────────────────────────────────────────┘