Annex 21 — 선박에서의 오염방지에 관한 규칙
287033 · 2026-07-01
■ Rules on the Prevention of Pollution from Ships [Appendix 21]
Designation Criteria for Companies Removing Facilities Containing Ozone-Depleting Substances (Related to Article 31)
Companies or organizations intending to remove facilities containing ozone-depleting substances must meet the following standards
.
1. In the case of intending to remove Freon-based ozone-depleting substances
a. Recovery Equipment
1) The recovery equipment includes each connection of the recovery equipment, necessary maintenance procedures, replacement of parts, and repair
Operating instructions including information regarding START must have been provided.
2) If the recovery device includes a filter or a dryer, the replacement time shall be indicated.
(Limited to those including a playback device)
3) Non-condensable substances are automatically removed or guidelines regarding removal procedures are provided
It must be (limited to those including a playback device)
4) Removal of non-condensable substances, removal of impurities contained in oil discharges and ozone-depleting substances
The total loss of ozone-depleting substances generated during the START process is what the recovery facility can handle.
It must be less than 3% of the total amount of ozone-depleting substances.
In the case of recovery facilities that recover two or more types of ozone-depleting substances, within 15 minutes
It will be able to remove ozone-depleting substances remaining inside the recovery facility.
6) The following information shall be displayed in a conspicuous place outside the recovery facility
a) Manufacturer's Name
b) Type of recovery equipment (for recovery or for recovery/regeneration)
) Recoverable ozone-depleting substances
ra) Recovery speed
e) Final Recovery Negative Pressure
f) Amount of ozone-depleting substances remaining in the recovery facility when the recovery operation is completed
B. Detention Facilities
Recovery container capable of storing recovered ozone-depleting substances without leakage (recovery method
Must possess (including a recovery container embedded in the battery)
2. In the case of removing Halon-based ozone-depleting substances
Same as “in cases where Freon-based ozone-depleting substances are to be removed” in Subparagraph 1.