Annex 20 — 선박에서의 오염방지에 관한 규칙
287033 · 2026-07-01
■ Rules on the Prevention of Pollution from Ships [Attached Table 20] <Amended Nov. 19, 2020>
Technical Standards for Air Pollution Control Equipment (Related to Article 30, Paragraph 2)
1. Nitrogen Oxide Emission Control Agency
The nitrogen oxide emission control agency [manifests as] a diesel engine (hereinafter referred to as the “engine” in this subparagraph) follows
Inspected and measured in accordance with the standards of each item, the emission amount of nitrogen oxides is Article 43, Paragraph 1 of the Act
Permissible Emission Standards for Nitrogen Oxides pursuant to START (hereinafter referred to as “Permissible Emission Standards for Nitrogen Oxides”)
.
a. Institutional Inspection
Nitrogen oxide emission inspections for engines shall be performed by the following methods.
1) Conduct on a test bench regardless of location
2) Limited to sample institutions of institution families and institution groups, and shall test in accordance with the following
a) Adjust to satisfy the permissible nitrogen oxide emission standards
b) Measure nitrogen oxide emissions
B. Test Period
The institution shall have a nitrogen oxide technical code corresponding to any of the following: (NOx Technical
Tests must be performed according to the test cycle in accordance with Code 2008).
1) Engine used in constant speed main engine and variable pitch propeller system: Type E2 test main
기
2) Main and auxiliary engines operating under propeller laws: E3 type test cycle
3) Constant Speed Auxiliary Engine: Type D2 Test Cycle
4) Not subject to the provisions of 1) through 3) where the speed or load changes
Auxiliary: Type C1 Test Cycle
. Exhaust gas analyzer
When analyzing exhaust gases, the following analyzer must be used.
1) Carbon Monoxide (CO) Analyzer: Absorption Non-Dispersive Infrared Analyzer (NDIR)
2) Carbon Dioxide (CO2) Analyzer: Absorption Non-Dispersive Infrared Analyzer (NDIR)
3) Oxygen (O2) Analyzer: Zirconium Oxide Detector (ZRDO), Electrochemical Detector
(ECS) or paramagnetic detector (PMD). Provided, however, that a zirconium oxide detector (ZRDO)
Cannot be used in dual-fuel or gas-fuel engines.
4) Nitrogen Oxide (NOx) Analyzer
a) When measured in a dry state, nitric oxide (NO) and nitrogen dioxide
Chemiluminescence analyzer (CLD) or thermal chemiluminescence analyzer equipped with (NO2) converter
(HCLD)
b) When measuring under humid conditions, store at temperatures between 55℃ and 200℃
Thermochemiluminescence Analyzer (HCLD) with Specified Transducer [Water Vapor Quench Check
(Quench check) satisfied is limited]
5) Hydrocarbon (HC) Analyzer: Exhaust gas temperature can be maintained at 190℃±10℃
lock Heated detector, valve and related components
It must be of the START (HFID) type. However, gas that does not inject liquid fuel for ignition
The hydrocarbon analyzer used in fuel engines is a non-heated flame ion detection (FID) type.
.
d. Measurement of exhaust gas flow rate
The exhaust gas flow rate shall be measured according to any of the following methods.
1) Direct measurement method
Directly measure the exhaust gas flow rate using a flow nozzle or an equivalent measuring system
2) Method for measuring air and fuel
a) by measuring internationally recognized air and fuel consumption, the exhaust gas flow rate
Apply the calculation method END
b) The measurement of air and fuel consumption is performed using an air consumption meter and a fuel consumption meter
What to use
3) Fuel Flow Rate and Carbon Comparison Method
according to the carbon comparison method of Appendix 6 of the Nitrogen Oxide Technical Code
Calculate exhaust gas flow rate from exhaust gas concentration
E. Measurement of exhaust gas
Carbon monoxide (CO), carbon dioxide (CO2), hydrocarbons (HC), nitrogen oxides (NOx), and acids
Major exhaust gas components such as oxygen (O2) must be measured and analyzed.
B. Evaluation of gas emissions
The evaluation of gas emissions is the carbon monoxide (CO) and carbon dioxide (CO2) at each load during the final 60 seconds.
Average measured values of (CO2), hydrocarbons (HC), nitrogen oxides (NOx), and oxygen (O2) and accordingly
It must be determined by correcting the error value generated by the corresponding analyzer.
In addition, definitions of terms regarding nitrogen oxide emission control agencies, agency families and agencies
The classification of groups and criteria for selecting sample institutions, etc., must comply with the Nitrogen Oxide Technology Code.
2. Exhaust gas purification device for preventing nitrogen oxide emissions
The exhaust gas purification device for preventing nitrogen oxide emissions is a nitrogen oxide emission prevention device according to subparagraph 1.
installed in a diesel engine that does not meet the technical standards for the pipe, and the nitrogen oxide emissions
Technical standards set forth in international agreements to enable reduction below permissible nitrogen oxide emission standards
.
3. Exhaust gas purification device for sulfur oxides
The exhaust gas purification device for sulfur oxides is the sulfur oxide emission limit standard amount pursuant to Article 34, Paragraph 2
Sulfur oxide emissions of less than or equal to (hereinafter referred to as the “Sulfur Oxide Emission Limit Standard Amount” in this table)
In order for this to be reduced, it must meet the following criteria.
a. Sulfur oxide emissions at any load point sulfur oxide emission limit standard
amount or less
b. A technical documentation containing the following items shall be provided to the user
1) Manual for Exhaust Gas Purification Devices for Sulfur Oxides and Necessary Auxiliary Devices, Manufacturer/Model
· Model · Serial Number and Other Necessary Details
2) Maximum and minimum mass flow rates of exhaust gas
3) Output/Type, Boiler or
Relevant variables of the fuel oil combustion system of a diesel engine and the following contents
a) Boiler: Ratio of air volume to maximum fuel volume at 100% load
b) Diesel engine: Engine cycle (2-cycle or 4-cycle)
4) Maximum and minimum flushing water flow rate, inflow pressure, minimum inflow water alkalinity (pH)
5) Exhaust gas inlet temperature range
6) Range of exhaust gas inlet and outlet pressures
7) Matters concerning design and operation to obtain values below the sulfur oxide emission limit standard
port
8) Limiting conditions or emission values of exhaust gas purification devices for sulfur oxides are sulfur oxide emission limits
Maintenance, Service, and Adjustment Standards to Ensure Standard Quantities Are Not Exceeded
9) Inspection means to maintain performance and enable continued use
10) Performance changes according to cleaning water characteristics across the entire range and design standards for cleaning water devices
The sulfur oxide exhaust gas purification device installed in the main propulsion diesel engine is the engine's 2
It shall comply with the criteria of Item (a) in all load ranges between 5 and 100%.
. The exhaust gas purification device for sulfur oxides installed in the auxiliary diesel engine is the engine's 10~
100%
E. Sulfur oxide installed in diesel engines to supply power to main propulsion and auxiliary engines
The exhaust gas purification device for water shall comply with the criteria of subparagraph (d).
B. The exhaust gas purification device for sulfur oxides installed in the boiler covers 10–100% of the boiler
It shall comply with the criteria of Item (a) across all load ranges.
d. Exhaust gas purification device for sulfur oxides even at loads below the specifications of items c through f
shall be operated continuously. In this case, the fuel oil combustion device shall operate in an idle state
If required, sulfur dioxide (SO2) at standard oxygen concentration (diesel engines 15%, boilers 3%)
The emission concentration of shall not exceed 0.005%.
A. Having a means to automatically record the sulfur dioxide emission rate during the operation of a vessel
It must be, and a direct monitoring system must be installed or carbon dioxide
Randomly check exhaust gas quality through the ratio of sulfur dioxide (ppm) to sodium (%)
It must be able to prove conformity by START.
J. Recording means and direct monitoring devices pursuant to subparagraph A shall be robust and heat-resistant
will be read-only
Vehicle. There shall be a means to monitor the discharged wash water.
K. For each combustion unit, the on-board monitoring manual
Provided so that each exhaust gas purification device for sulfur oxides can be identified and its conformity demonstrated
is likely
T. Must meet cleaning water discharge standards
F. Installing a device on a vessel that has not undergone the load tests from Item C to Item F, and sulfur oxides
When applying a continuous exhaust gas monitoring method, installation inspection of monitoring equipment
Determine whether it meets the criteria of Item (a) through START and discharge tests.
H. In addition, definitions of terms regarding exhaust gas purification devices for sulfur oxides, scope of device approval,
Exhaust gas measurement procedures, monitoring equipment and wash water standards, etc. as stipulated in international conventions
Must conform to technical standards
4. Vapor Collection Control Device
a. The vapor collection control device for controlling the collection of vapors from a vessel is as follows:
standard.
1) Not releasing oil vapors generated from a ship into the atmosphere and sending them to land
to produce a manifold, oxygen concentration measuring and monitoring device (
(Applicable only to vessels) and must be equipped with a pressure monitoring device
2) Fixed-pipe steam connections are installed as close as possible to the loading manifold
willbe
3) Simultaneously collecting vapors from different types of cargo that can react with each other
When starting, all steam collectors shall be able to maintain a separated state.
4) To allow drain discharge or collection of condensed liquid at a low position of the duct
It must be equipped with a drain valve, etc.
The steam collection tube system must be electrically grounded to the hull and electrically connected
must have attributes
6) When using an inert gas supply pipe for a steam collector, the steam collector and
Means to separate the active gas supply pipe shall be provided.
The steam collector does not affect the normal operation of the cargo hold vent system.
is likely
B. Steam pipe connections, cargo measuring equipment, tank solid-liquid level alarm devices, steam overpressure and negative pressure
Technical standards for protection shall be the technical standards prescribed in international conventions.
5. Standard Onboard Incinerator
A general-type onboard incinerator is compliant with the technical standards for incinerators pursuant to Item 14 of Annex 8.
should.
6. Onboard incinerator type-approved in accordance with standards set by the International Maritime Organization
Onboard incinerators that have received type approval in accordance with the standards established by the International Maritime Organization (IMO) are specified in Annex 8, No. 14
It must comply with the technical standards for incinerators pursuant to and the following standards.
a. The capacity of the incinerator shall be 4,000 kW or less
b. The oxygen content of the exhaust gas shall be 6% or more and less than 12%
The combustion gas will be rapidly cooled to 350°C within 2.5m of the outlet.
a. The temperature of the combustion gas at the outlet shall be maintained at 850℃ or higher and less than 1,200℃
It
E. The outlet temperature and oxygen content shall be measured during combustion.