Annex 6 — 선박에서의 오염방지에 관한 규칙
287033 · 2026-07-01
■ Rules on the Prevention of Pollution from Ships [Appendix 6] <Amended June 30, 2021>
Technical Standards for Sewage Pollution Prevention Facilities (Related to Article 14, Paragraph 3)
1. Sewage Treatment Device
a. The manure treatment device must be equipped with the following devices.
1) Air pipe, grinder and screen
2) Auxiliary pump and piping for discharge or transfer of treated water
3)Capable of securing a ventilation rate of at least 50 times the average inflow volume of manure, or equivalent
A ventilation device capable of securing capabilities exceeding a certain level END
B. The material of the sewage treatment device shall conform to the following standards.
The interior of each tank in contact with manure is made of steel plate and epoxy-lined (epoxy
lining: Applying epoxy adhesive to the contact surfaces of materials to prevent erosion and corrosion
day), FRP lining (FRP lining: material contact to prevent erosion and corrosion
Applying reinforced plastic chemicals to the surface) or applying tar epoxy coating or
Will be stainless steel or of an equivalent or higher standard
Piping and valves shall be made of steel pipe, cast iron, or a material of equivalent or superior quality, with corrosion resistance
there will be
The structure of the manure treatment device shall comply with the following standards.
1)Maintenance, management, and inspection can be easily performed, and the mixed liquid and treated water inside the tank
It must be a structure capable of collecting specimens.
A high liquid level alarm device must be installed, and the detectors installed inside the tank must be explosion-proof.
shouldbestructure
3)
structure will be
d. The following markings shall be affixed to the manure treatment device.
1) Range of operating temperature and salinity suitable for the operating conditions of the treatment device
2) Processing Capacity (Daily Average Throughput and Biochemical Oxygen Demand Reduction Efficiency)
E. Other treatment methods other than the biochemical treatment methods prescribed in subparagraphs A through D
method, the Minister of Oceans and Fisheries separately
is determined and announced.
2. Manure Grinding and Disinfection Device
a. The manure grinding and disinfection device must be equipped with the following devices.
1) Circulating water device
2) Auxiliary tank
3) Discharge pump. However, the obligation to install an external discharge pipe pursuant to the proviso of Article 14, Paragraph 2, Subparagraph 2
In the case of a vessel exempt from START that can discharge sewage into the ocean without a discharge pump
.
4) Circulation pump
5) Manure filter
6) Grinding device
B. The circulating water system shall comply with the following standards.
The interior of each tank in contact with manure is made of steel plate with epoxy lining, FRP lining
coated with tar epoxy or stainless steel or equivalent
Must be a material of standard or higher
2)The inside of the tank shall be treated to prevent rust
3)Can easily inject disinfectant
4) Be equipped with a par value indicator
5) It shall be a structure that allows easy inspection of the inside of the tank
It will be able to prevent odors from the storage tank from emitting to the outside.
. The auxiliary tank must comply with the following standards.
The inside of each tank in contact with manure is made of steel plate and epoxy lining, FRP lining
or tar-epoxy coated or stainless steel or equivalent level
or higher
2) The inside of the tank shall be treated to prevent rust
The inside of the tank can be cleaned with water.
4) Be equipped with a par value indicator
5) It shall be a structure that allows easy inspection of the inside of the tank
d. The discharge pump shall comply with the following standards.
1) It shall be a structure that facilitates the discharge of manure, etc.
2) It must have a sufficient capacity to discharge manure, etc., into land-based containment facilities
E. The circulation pump shall comply with the following standards.
1) Be corrosion resistant
2) It shall have a sufficient capacity to flush away feces, etc. from the toilet
B. The manure filter shall comply with the following standards.
1) Be corrosion resistant
2) It shall be a structure that is not clogged by manure, etc.
Inc. The grinding device shall comply with the following standards.
1) Be corrosion resistant
2) It shall be a structure capable of grinding manure, etc.
A. The total capacity of the circulating water system and auxiliary tanks shall be 150 liters or more.
3. Manure Storage Tank
a. A manure storage tank includes a liquid level indicator that visually displays the amount of manure stored, a sounding pipe
It must be equipped with a storage tank and a viewing device capable of verifying the device or the amount of manure stored.
. However, gas must not be released from such a device.
B. Sewage storage tanks shall [regarding] the vessel's navigation area, maximum passenger capacity, and sewage discharge area, etc.
In consideration, it must be equipped with a storage capacity greater than the size specified in the following formula.
1) Ships built after May 3, 1993
a) Vessels operating only within 12 nautical miles from the baseline
Sewage storage tank capacity (ℓ)={(Number of personnel on duty while anchored × Anchoring time/3) + (Maximum number of personnel)
Crew × Estimated Sailing Time/3)} × Washing Water Usage ×
Number of trips × 1.2
Here,
Anchoring time: Time excluding scheduled sailing time from 1 day and 24 hours
Maximum passenger capacity: Maximum passenger capacity as stated on the ship inspection certificate
Estimated time of voyage: Time of anchorage at ports of call from departure port to final destination
. However, for parts without a fixed route
For regular vessels, the scheduled daily sailing time is 8 hours
.
Water usage (ℓ): According to the toilet manufacturer's specifications (per flush usage)
Amount consumed per use if not specified
.
Voyage Number: The number of voyages until discharge using onshore facilities
b) A vessel having a navigation area extending 12 nautical miles from the territorial sea baseline
Sewage storage tank capacity (ℓ)={(Number of personnel on duty while anchored × Anchoring time/3)+(Maximum number of personnel)
Personnel × 3 nautical miles or more from the territorial sea baseline 12 nautical miles
/ 3)} × number of washes
Usage × 1.2
Here, the anchoring time, maximum passenger capacity, and cleaning water usage are as in (a).
2) Ships built before May 3, 1993
1). However,
As a vessel with an estimated sailing time of less than 1.5 hours, due to the structure of the vessel, in formula 1)
Vessels that do not satisfy at least 50% of the manure storage tank capacity determined according to
can be at least 30% of the manure storage tank capacity determined according to formula 1).
There is.
The inside of each tank in contact with manure is made of steel plate with epoxy lining and FRP lining.
or tar-epoxy coated or stainless steel or equivalent level this
Must be the material of the
d. Install a discharge pump of sufficient capacity to discharge manure, etc. to land-based receiving facilities
shall install. However, pursuant to the proviso of Article 14, Paragraph 2, Subparagraph 2, the obligation to install an external discharge pipe
A vessel that is restricted and capable of discharging sewage into the ocean or on land without a discharge pump
, a discharge pump may not be installed.
4. External discharge pipe
a. The discharge pipe device is a pipe capable of transferring manure, etc. from a storage tank to a receiving facility and
must be equipped with standard connectors.
or. so that the pipes of the receiving facility can be connected to the discharge mechanism of the ship, the pipes on both sides
negative table must be attached.
┏━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━┓
┃Item │Specification ┃
┠─────────────┼──────────────────────┨
┃OuterDiameter │210 ㎜ ┃
┠─────────────┼──────────────────────┨
┃insidediameter │Suitable diameter for connecting pipes ┃
┠─────────────┼──────────────────────┨
┃Diameter of a bolt circle │170 ㎜ ┃
┠─────────────┼──────────────────────┨
┃Flange groove width │18 ㎜ ┃
┠─────────────┼──────────────────────┨
┃Flange thickness │16 ㎜ ┃
┠─────────────┼──────────────────────┨
┃Diameter and Quantity of Bolts and Nuts │4 pieces each with a diameter of 16 mm and a suitable length ┃
┗━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━┛
Remarks
The flange is designed to accommodate pipes with an inner diameter of up to 100 mm.
It must be made of steel or equivalent material and have a flat surface, and suitable
When using the corresponding gasket, it is capable of withstanding an operating pressure of 6 kg per 1 cm².
ya must.
For vessels with a depth of 5m or less, the inner diameter of the discharge connector shall be 38㎜
can do less than.
3) In the case of vessels engaged in designated routes, such as passenger ships, in place of the discharge pipe
Discharge connection in a form equivalent to a rapid coupling recognized by the Minister of Oceans and Fisheries
You can install a START ball.