Annex 6 — 연구실 안전환경 조성에 관한 법률 시행령
286181 · 2026-05-20
■ Enforcement Decree of the Act on the Creation of a Safe Research Environment [Appendix 6] <Amended Feb. 22, 2022>
Registration Requirements for Laboratories Safety Inspection Agencies (Related to Article 14, Paragraph 2)
1. Technical Personnel: Must possess all of the personnel listed in each of the following items
a. One or more persons falling under any of the following
Industrial Safety Instructor pursuant to Article 142 of the Industrial Safety and Health Act (Mechanical Safety · Electrical Safety
(limited to the field of electrical and chemical safety) or Industrial Health Instructor, "National Technical Qualification
Professional Engineer in Gas, Professional Engineer in Mechanical Safety, Professional Engineer in Industrial Hygiene Management, and Firefighting Engineer under the "START Act"
Company, Professional Engineer in Ergonomics, Professional Engineer in Electrical Safety, or Professional Engineer in Chemical Safety
2) In the fields of safety, mechanical, electrical, chemical, firefighting, gas, industrial hygiene, public health or biology
Person with at least one year of experience in safety work after obtaining a doctoral degree
3) Acquired the qualification of Laboratory Safety Manager pursuant to Article 34, Paragraph 1 of the Act, and Article 2
Persons with at least 3 years of experience in safety work after completing education and training in accordance with the START clause
b. At least one person who meets the relevant qualification requirements for each of the following fields
┌────────┬───────────────────────────────┐
│Field │Eligibility Requirements │
├────────┼───────────────────────────────┤
│General Safety, Machinery, │A person falling under any of the following │
│Electrical and Chemical Engineering │Industrial Safety Instructor pursuant to Article 142 of the Industrial Safety and Health Act (Machine Safety │
│ │Limited to the fields of electrical, electrical safety, and chemical safety) │
│ │1-2) Laboratory safety personnel who have completed education and training pursuant to Article 34, Paragraph 2 of the Act │
│ │Manager │
│ │2) Person with at least 1 year of safety work experience after obtaining the Industrial Safety Engineer qualification │
│ │AM │
│ │3) Those with 3 years or more of safety work experience after obtaining the Industrial Safety Technician qualification │
│ │person │
├────────┼───────────────────────────────┤
│Firefighting │A person falling under any of the following │
│ │1) Professional Fire Protection Engineer │
│ │1-2) Laboratory safety personnel who have completed education and training pursuant to Article 34, Paragraph 2 of the Act │
│ │Manager │
│ │2) Person with at least 1 year of safety work experience after obtaining the Fire Protection Equipment Engineer qualification │
│ │AM │
│ │3) Those with 3 years or more of safety work experience after obtaining the Industrial Engineer Fire Protection Equipment qualification │
│ │person │
├────────┼───────────────────────────────┤
│Gas │A person falling under any of the following │
│ │1) Professional Gas Engineer │
│ │1-2) Laboratory safety personnel who have completed education and training pursuant to Article 34, Paragraph 2 of the Act │
│ │Manager │
│ │2) After obtaining the Gas Master Craftsman or Gas Engineer qualification, 1 │
│ │People with more than 1 year │
│ │3) Person with 3 years or more of safety work experience after obtaining the Gas Industry Engineer qualification │
│ │AM │
├────────┼───────────────────────────────┤
│Industrial Hygiene and │A person falling under any of the following │
│Biology │1) Industrial Health Instructor pursuant to Article 142 of the Industrial Safety and Health Act │
│ │2) Professional Engineer in Industrial Hygiene Management │
│ │2-2) Laboratory safety personnel who have completed education and training pursuant to Article 34, Paragraph 2 of the Act │
│ │Manager │
│ │3) Those with at least 1 year of safety work experience after obtaining the Industrial Hygiene Management Engineer qualification │
│ │person │
│ │4) 3 years or more of safety work experience after obtaining the Industrial Hygiene Management Technician qualification │
│ │Merchant Person │
└────────┴───────────────────────────────┘
2. Equipment: Be equipped with all of the following equipment by field. However, two or more of the functions of the relevant equipment
In the case of equipped with multi-functional equipment, it shall be deemed as equipped with individual equipment.
┌─────────┬──────────────────────────────┐
│Field │Equipment │
├─────────┼──────────────────────────────┤
│General Safety, Machinery, │Electrostatic Charge Meter, Ground Resistance Meter, Insulation Resistance Meter │
│Electrical and Chemical Engineering │ │
├─────────┼──────────────────────────────┤
│Firefighting and Gas │Gas leak detector, gas concentration meter, carbon monoxide concentration meter │
├─────────┼──────────────────────────────┤
│Industrial Hygiene and │Dust meter, noise meter, oxygen concentration meter, anemometer, illuminance meter (brightness │
│Biology │Measuring Instrument) │
└─────────┴──────────────────────────────┘