Annex 1 — 청소년활동 진흥법 시행령

284945 · 2026-03-24

■ Enforcement Decree of the Youth Activities Promotion Act [Appendix 1-2] <Amended July 2, 2019> Fields and Contents of Comprehensive Safety and Hygiene Inspection (Related to Article 11, Paragraph 3) ┌───────┬─────────────────────────────────┐ │Inspection Target Areas│InspectionDetails │ ├───────┼─────────────────────────────────┤ │1. Safety·Hygiene │a. Whether safety-related insurance is purchased │ │Field Common │B. Availability of design drawings and various documents │ │ │. Whether a statutory safety and hygiene manager has been appointed │ │ │d. Whether statutory safety and hygiene inspections have been conducted and training has been completed │ ├────┬──┼─────────────────────────────────┤ │2. Safety │Architecture│A. Structural safety, including ground conditions, deformation, cracking, and aging of the structure │ │ │ │B. Condition of architectural finishes, such as roof finish, interior/exterior finish, and windows, and presence of leakage │ │ │ │. Building management status, such as disaster management and safety management │ │ ├──┼─────────────────────────────────┤ │ │Civil Engineering│A. Whether there is settlement, cracking, or overturning of structural parts of retaining walls, stone walls, and fences │ │ │ │B. Management status, such as whether slopes have eroded │ │ │ │. Cleaning and maintenance status of drainage ditches, sumps, manholes, etc. │ │ ├──┼─────────────────────────────────┤ │ │Machine│a. of individual facilities such as water supply and hot water supply facilities, sewage facilities, rainwater facilities, and sanitary fixtures │ │ │ │Presence of leakage, corrosion, cracks, or damage │ │ │ │B. Leakage, corrosion, or damage to air conditioning and ventilation equipment, such as heat source equipment and HVAC equipment │ │ │ │status and normal operation status │ │ ├──┼─────────────────────────────────┤ │ │Firefighting│a. Fire extinguishing equipment (fire extinguishers, fire hydrants, etc.), alarm equipment (automatic fire detection equipment, non- │ │ │ │Normal operation of broadcasting equipment, etc.), evacuation facilities (guide lights, evacuation equipment, etc.) │ │ │ │B. Firefighting activity facilities (connecting water supply pipes, smoke control facilities, etc.), firefighting water supply facilities and │ │ │ │Management status of fire prevention and fire control facilities (escape stairs, fire doors, etc.) │ │ │ │. Management status of hazardous materials (flammability or combustibility, etc.) │ │ ├──┼─────────────────────────────────┤ │ │Electrical│A. Compliance with standard values ​​during insulation resistance measurement │ │ │ │B. Installation and operation of earth leakage circuit breakers and miniature circuit breakers │ │ │ │. Use of standard wires, check for insulation damage, and proper maintenance status of outlets │ │ ├──┼─────────────────────────────────┤ │ │Gas│A. Gas equipment such as gas cylinders, pressure regulators, gas meters, valves, hoses, etc. │ │ │ │Status │ │ │ │B. Compliance with piping installation standards and check for gas leaks │ │ │ │. Operating status of combustion device, overpressure safety device, gas leak shut-off device, etc. │ ├────┴──┼─────────────────────────────────┤ │3. Hygiene │A. Hygiene management of food service facilities, status of food ingredient storage and hygiene management │ │ │B. Compliance with facility standards, such as kitchens, water supply facilities, storage facilities, and restrooms │ │ │. Compliance with raw material usage, process control, and storage standards │ │ │d. Whether water quality inspection was conducted │ ├───────┴─────────────────────────────────┤ │Remarks: Comprehensive safety and hygiene inspections shall meet the respective applicable safety and hygiene standards pursuant to relevant laws and regulations │ │should be carried out as a method to verify compliance. │ └─────────────────────────────────────────┘