Annex 4 — 소방시설공사업법 시행령

287253 · 2026-07-01

■ Enforcement Decree of the Firefighting Facilities Construction Business Act [Table 4] <Amended Dec. 10, 2019> Placement Standards and Period for Firefighting Construction Supervisors (Related to Article 11) 1. Placement Standards for Fire Protection Construction Supervisors ┌──────────────────────┬─────────────────────┐ │Criteria for Assigning Supervisors │Standards for Firefighting Facility Construction Sites │ ├───────────┬──────────┤ │ │Responsible Supervisor │Assistant Supervisor │ │ ├───────────┼──────────┼─────────────────────┤ │a. By the Ordinance of the Ministry of the Interior and Safety │by Ministry of the Interior and Safety Decree │1) Specific fire protection facilities with a gross floor area of ​​200,000 square meters or more │ │Special Grade Supervision determining │determining entry-level supervisor │Construction site of the subject matter │ │Professional Fire Protection Engineer │Firefighting construction inspection of the above │2) 40 floors or more including basement floors │ │ │Lee Won (Machinery field and all │Construction site of a specific fire safety target │ │ │Technical field) │ │ ├───────────┼──────────┼─────────────────────┤ │B. By Ordinance of the Ministry of the Interior and Safety │by Ministry of the Interior and Safety Decree │1) Gross floor area 30,000 m² or more 200,000 m² or less │ │Determining Special Grade Supervision │determining entry-level supervisor │(Apartments are │ │Firefighters of more than one won │Firefighting construction inspection of the above │excluding │ │Company Supervisor (Mechanical Division │Lee Won (Machinery field and all │2) 16 floors or more including basement floors, 40 floors │ │and electrical fields) │Technical field) │미만인 특정소방대상물의 공사 현장 │ ├───────────┼──────────┼─────────────────────┤ │. By the Ordinance of the Ministry of the Interior and Safety │by Ministry of the Interior and Safety Decree │1) Water spray fire extinguishing system (hose reel type fire extinguishing │ │determining advanced supervision │determining entry-level supervisor │equipment is excluded) or smoke control equipment is installed │ │Firefighters of more than one won │Firefighting construction inspection of the above │Construction site of a specific fire safety target being installed │ │Company Supervisor (Mechanical Division │Lee Won (Machinery field and all │2) Gross floor area 30,000 m² or more 200,000 m² │ │and electrical fields) │Technical field) │터 미만인 아파트의 공사 현장 │ ├───────────┴──────────┼─────────────────────┤ │d. Intermediate-level supervisors prescribed by the Ordinance of the Ministry of the Interior and Safety │Gross floor area 5,000 m² or more 30,000 m² │ │or higher (mechanical field and │Construction site of a specific fire safety target │ │Electrical field) │ │ ├──────────────────────┼─────────────────────┤ │E. Junior supervisors prescribed by the Ordinance of the Ministry of the Interior and Safety │1) Specific fire safety for gross floor area of ​​less than 5,000 square meters │ │or higher (mechanical field and │Construction site of the subject matter │ │Electrical Field) │2) Construction site of the underground section │ └──────────────────────┴─────────────────────┘ Remarks a. "Chief Supervisor" refers to a person who oversees the supervision duties regarding the entire construction project. . B. "Assistant Supervisor" refers to an assistant who assists the Chief Supervisor and performs supervisory duties under the direction of the Chief Supervisor . . In cases where the total floor area of ​​the fire protection facility construction site is 200,000 square meters or more, 200,000 square meters For gross floor area exceeding 100,000 square meters (gross floor area exceeding 200,000 square meters If this is less than 100,000 square meters, it shall be deemed to be 100,000 square meters) for every 1 assistant supervisor More than [number] additional personnel must be deployed. . Notwithstanding the table above, for the construction of fire protection facilities that do not fall under on-site construction supervision, auxiliary A supervisor may not be assigned. E. If a specific construction site meets the criteria for two or more construction sites, the relevant construction Instead of assigning supervisors individually as required by site standards, the highest grade among them... supervisors may be assigned. 2. Placement Period of Fire Protection Construction Supervisors a. The supervisory contractor shall station a fire protection construction supervisor in accordance with the standards of Item 1 for on-site construction supervision and general Classified as construction supervision, from the commencement date of fire facility construction, fire facility completion inspection certificate It shall be deployed for a period determined by the Ordinance of the Ministry of the Interior and Safety during the period up to the date of issuance. b. Notwithstanding subparagraph (a), the supervisory contractor shall, in cases where there is no impediment to construction management, quality, and safety , the relevant Supervisors may not be assigned to the construction site during the period when construction is suspended. 1) In the event that construction of the relevant process is suspended for a certain period due to complaints or seasonal factors, etc. 2) Insufficient budget, etc., the client (including the contractor in the case of subcontracting. Hereinafter referred to in this paragraph ) due to causes attributable to the company or force majeure such as natural disasters, during a certain period If interrupted 3) If the Client requests a suspension of work