Annex 10 — 소방시설 설치 및 관리에 관한 법률 시행령

287375 · 2026-07-01

■ Enforcement Decree of the Act on Installation and Management of Firefighting Facilities [Appendix 10] <Amended Nov. 25, 2025> Criteria for Imposing Administrative Fines (Related to Article 52) 1. General standard a. The criteria for imposing increased administrative fines based on the number of violations shall be the same as those committed within the past year This applies when a fine is imposed for an illegal act. In this case, the calculation of the period is The date on which a disposition imposing an administrative fine was received for the violation and, again after that disposition, the same above It is based on the date the violation was detected. b. In cases where an aggravated disposition is imposed pursuant to subparagraph a, the order of application of the aggravated disposition is the one above Prior to the violation, the order of the imposed disposition (if two administrative fine dispositions are issued within the period pursuant to subparagraph (a) 상 있었던 경우에는 높은 차수를 말한다)의 다음 차수로 한다. . In any of the following cases, the imposing authority shall apply the individual standards of Subparagraph 2 The amount of the administrative fine may be reduced and imposed within the range of one-half. However, the administrative fine This does not apply to violators who are delinquent in paying fees. 1) Where the violation is recognized as being due to minor negligence or error 2) The fact that the offender has made efforts to correct or resolve the state of violation of the law Cases where it is recognized 3) In cases where the violator commits the violation for the first time and has maintained the relevant industry for at least 3 years as an exemplary Cases where the fact of conducting business in a systematic manner is recognized 4) If the violator suffers significant loss to property due to a disaster such as fire or business conditions In the event that the business faces a serious crisis due to the deterioration of , 5) If the violator is subject to an administrative fine, a fine, or suspension of business under other laws for the same violation In case of receiving dispositions such as papers In addition, considering the degree of the violation, the motive and consequences of the violation, etc., the If it is recognized that there is a need to reduce the amount of the fine 2. Individual Standard ┌─────────────────────┬──────┬─────────┐ │위반행위 │근거 법조문 │Fine Amount │ │ │ │(Unit: 10,000 KRW) │ │ │ ├──┬──┬───┤ │ │ │1st │2차 │3차 │ │ │ │위반│위반│이상 │ │ │ │ │ │Violation │ ├─────────────────────┼──────┼──┴──┴───┤ │a. In the case of violating Article 12, Paragraph 1 of the Act │Article 61 of the Act │ │ │ │Paragraph 1 No. 1 │ │ │ │ │ │ │ 1) Except for the provisions of 2) and 3), firefighting facilities │ │100 │ │more than twice within the last year Fire Safety │ │ │ │standard │ │ │ │ │ │ │ │ 2) Firefighting facilities shall be repaired if any of the following malfunctions │ │200 │ │In the case of neglect due to START etc. │ │ │ │ │ │ │ │ a) When a fire pump is left in a broken state │ │ │ │U │ │ │ │ b) Fire receiver, power and monitoring control panel and │ │ │ │is power for fire fighting facilities (including emergency power │ │ │ │) or in a faulty state │ │ │ │If left unattended or manually operated, automatically │ │ │ │, then │ │ │ │ ) When the fire extinguishing system operates, the fire extinguishing piping │ │ │ │통하여 소화수가 방수되지 않는 상태 │ │ │ │or condition where the extinguishing agent is not discharged │ │ │ │If left as START │ │ │ │ │ │ │ │ 3) In the case where fire fighting facilities are not installed │ │300 │ ├─────────────────────┼──────┼─────────┤ │a. In violation of Article 15, Paragraph 1 of the Act, the construction site │Article 61 of the Act │300 │ │that has not installed or managed temporary firefighting facilities │Paragraph 1 No. 2 │ │ │case │ │ │ ├─────────────────────┼──────┼──┬──┬───┤ │. In violation of Article 16, Paragraph 1 of the Act, evacuation facilities, │Article 61 of the Act │100 │200 │300 │ │Closing or damaging fire compartments or fire protection facilities │Paragraph 1 No. 3 │ │ │ │ │ㆍIn the case of acts such as changing │ │ │ │ │ ├─────────────────────┼──────┼──┴──┴───┤ │. In violation of Article 20, Paragraph 1 of the Act, flame-retardant objects │Article 61 of the Act │200 │ │If the product is not installed above the flame retardant performance standards │Paragraph 1 No. 4 │ │ │If not │ │ │ ├─────────────────────┼──────┼─────────┤ │E. Inspection in violation of the first part of Article 22, Paragraph 1 of the Act │Article 61 of the Act │300 │ │In case of inspection without receiving capability assessment │Paragraph 1 No. 5 │ │ ├─────────────────────┼──────┼─────────┤ │b. In violation of the latter part of Article 22, Paragraph 1 of the Act, regarding │Article 61 of the Act │300 │ │In the case of not submitting inspection results to the person │Paragraph 1 No. 6 │ │ │U │ │ │ ├─────────────────────┼──────┼─────────┤ │Company. The provision of self-inspection pursuant to Article 22, Paragraph 2 of the Act │Article 61 of the Act │ │ │Divisions and targets, deployment standards for inspection personnel, etc. │Paragraph 1 No. 7 │ │ │In case of violation of compliance requirements during inspection │ │ │ │ │ │ │ │ 1) Classification and Scope of Self-Inspection, etc. Self-Inspection │ │50 │ │per household in apartments, etc., in accordance with compliance requirements │ │ │ │If the check has not been performed │ │ │ │ │ │ │ │ 2) Classification of self-inspections excluding the provisions of 1) │ │300 │ │and targets, deployment standards for inspection personnel, etc. in-house │ │ │ │In case of violation of compliance requirements during inspection │ │ │ ├─────────────────────┼──────┼─────────┤ │A. As a result of the inspection in violation of Article 23, Paragraph 3 of the Act │Article 61 of the Act │ │ │In the case of failing to report START or reporting falsely │Paragraph 1 No. 8 │ │ │U │ │ │ │ │ │ │ │ 1) If the delayed reporting period is less than 10 days │ │50 │ │ │ │ │ │ 2) Delayed reporting period of 10 days or more but less than 1 month │ │100 │ │only case │ │ │ │ │ │ │ │ 3) If the delayed reporting period is 1 month or longer or │ │200 │ │If not reported │ │ │ │ │ │ │ │ 4) False │ │300 │ │, │ │ │ ├─────────────────────┼──────┼─────────┤ │. In violation of Article 23, Paragraph 4 of the Act, the implementation plan │Article 61 of the Act │ │ │is not completed within the period or │Paragraph 1 No. 9 │ │ │Failure to report the results of the completion of the implementation plan or │ │ │ │If reported falsely │ │ │ │ │ │ │ │ 1) Delayed completion period or delay reporting period │ │50 │ │is less than 10 days │ │ │ │ │ │ │ │ 2) Delayed completion period or delay reporting period │ │100 │ │is 10 days or more but less than 1 month │ │ │ │ │ │ │ │ 3) Delayed completion period or delay reporting period │ │200 │ │if it is 1 month or more, or completed or reported │ │ │ │If START was not performed, │ │ │ │ │ │ │ │ 4) Falsely reporting the results of the implementation plan completion │ │300 │ │is done │ │ │ ├─────────────────────┼──────┼──┬──┬───┤ │Vehicle. In violation of Article 24, Paragraph 1 of the Act, inspection record │Article 61 of the Act │100 │200 │300 │ │Failure to record the START table or specific fire safety target building │Paragraph 1 No. 10 │ │ │ │ │, │ │ │ │ │ │If not posted │ │ │ │ │ ├─────────────────────┼──────┼──┴──┴───┤ │k. Violating Article 31 or Article 32, Paragraph 3 of the Act │Article 61 of the Act │ │ │Fail to report or report falsely │Paragraph 1 No. 11 │ │ │done │ │ │ │ │ │ │ │ 1) If the delayed reporting period is less than 1 month │ │50 │ │ │ │ │ │ 2) Delayed reporting period of 1 month or more 3 months │ │100 │ │is less than │ │ │ │ │ │ │ │ 3) The delayed reporting period is 3 months or more, or │ │200 │ │If a report is not filed │ │ │ │ │ │ │ │ 4) In case of false reporting │ │300 │ ├─────────────────────┼──────┼─────────┤ │T. Succession to status in violation of Article 33, Paragraph 3 of the Act, │Article 61 of the Act │300 │ │Special facts regarding administrative disposition or suspension/closure │Paragraph 1 No. 12 │ │ │Failure to notify the persons responsible for the fire safety target │ │ │ │or falsely reported │ │ │ ├─────────────────────┼──────┼─────────┤ │Part. In violation of Article 33, Paragraph 4 of the Act, affiliated technology │Article 61 of the Act │300 │ │In the case of self-inspection without personnel participation │Paragraph 1 No. 13 │ │ ├─────────────────────┼──────┼─────────┤ │H. Increasing inspection performance results pursuant to Article 34, Paragraph 2 of the Act │Article 61 of the Act │300 │ │In the case of falsely submitting documents, etc. specifying [the act] │Paragraph 1 No. 14 │ │ │U │ │ │ ├─────────────────────┼──────┼──┬──┬───┤ │...violating an order pursuant to Article 52, Paragraph 1 of the Act │Article 61 of the Act │50 │100 │300 │ │or │Paragraph 1 No. 15 │ │ │ │ │In the case of falsely reporting or submitting data │ │ │ │ │ │Without justifiable reason or relevant public official │ │ │ │ │ │or │ │ │ │ │ │If avoided │ │ │ │ │ └─────────────────────┴──────┴──┴──┴───┘