Annex 8 — 소방시설 설치 및 관리에 관한 법률 시행령

287375 · 2026-07-01

■ Enforcement Decree of the Act on Installation and Management of Firefighting Facilities [Attached Table 8] [Effective Date: July 1, 2023] Subparagraph 1(d), Subparagraph 1 Item (f), Subparagraph 1 (g), Subparagraph 2 (d), Subparagraph 2 (f), No. 2 Subparagraph 4 Types and Installation Standards of Temporary Firefighting Facilities, etc. (Related to Article 18, Paragraphs 2 and 3) 1. Types of Temporary Firefighting Facilities a. Fire Extinguisher B. Simple fire extinguishing device: A device capable of extinguishing a fire by spraying water, as specified in the Fire Department It shall possess the performance specified by the device . Emergency alarm device: In the event of a fire, notifies nearby workers of the fire As a device capable of doing so, it shall possess the performance characteristics determined by the Commissioner of the Fire Department. d. Gas leak alarm: Detects the leakage or generation of flammable gas and alarms As a device that has received type approval and product inspection pursuant to Article 37 of the Act E. Simple evacuation guidance line: A device capable of guiding the direction of an evacuation exit in the event of a fire. It must possess the performance capabilities determined by the Commissioner of the Fire Department. B. Emergency lighting: To enable safe and smooth evacuation activities in the event of a fire As an automatically illuminating lighting device, it shall possess the performance specifications determined by the Commissioner of the Fire Department. Inc. Fireproof cloth: When combustible materials are ignited by sparks generated during operations such as welding and cutting A fabric or non-combustible article that prevents such occurrence and possesses the performance characteristics prescribed by the Commissioner of the Fire Department and will be 2. Types and Scale of Construction Works Requiring Installation of Temporary Firefighting Facilities a. Fire extinguishers: In accordance with Article 6, Paragraph 1 of the Act, consent must be obtained from the Head of the Fire Department or the Head of the Fire Station. The new construction, expansion, alteration, reconstruction, relocation, change of use, or replacement of a specific fire safety target The site of fire-hazardous work pursuant to Article 15, Paragraph 1 of the Act during construction for repairs, etc. (hereinafter It shall be installed at the “Fire Hazard Work Site” in this table. B. Simple fire extinguishing device: Installed at a fire-hazardous work site of any of the following construction projects . 1) Gross floor area of ​​3,000㎡ or more 2) Basement floor, windowless floor, or floor 4 or higher. In this case, the floor area of ​​the relevant floor is 600㎡ or higher applies only. . Emergency alarm device: To be installed at a fire-hazardous work site of any of the following construction projects . 1) Gross floor area 400㎡ or more 2) Basement or windowless floor. In this case, only if the floor area of ​​the relevant floor is 150㎡ or more is treated. d. Gas leak alarm: Fire hazard in basements or windowless floors with a floor area of ​​150㎡ or more Install at the work site. E. Simplified Evacuation Guidance Lines: Fire Hazard in Basements or Windowless Floors with a Floor Area of ​​150㎡ or More Install at the work site. B. Emergency Lighting: Fire hazard work in basements or windowless floors with a floor area of ​​150㎡ or more Install on-site. Inc. Fireproof Cloth: Installed at fire-hazardous work sites where welding or cutting operations are being performed. 3. A firefighting facility similar in function and performance to a temporary firefighting facility, which has installed a temporary firefighting facility Firefighting facilities considered as a. Firefighting facilities deemed to have installed a simplified fire extinguishing device: as determined and notified by the Commissioner of the National Fire Agency Fire extinguisher conforming to the standards (limited to cases where it is installed near the discharge outlet of a connected water supply system d) or indoor fire hydrant system B. Firefighting facilities deemed to be equipped with an emergency alarm device: Emergency broadcasting equipment or automatic fire Detection Equipment . Firefighting facilities deemed to have installed simplified evacuation guidance lines: evacuation guidance lines, evacuation exit guide lights, Exit sign or emergency lighting