Annex 4 — 원자력시설 등의 방호 및 방사능 방재 대책법 시행령

287333 · 2026-07-01

■ Enforcement Decree of the Act on Protection of Nuclear Facilities, etc. and Radiation Disaster Prevention Measures [Appendix 4] <Amended 2011.10.25> National Radiation Emergency Medical Center, Functions of Primary and Secondary Radiation Emergency Medical Institutions and Designation Criteria for Primary and Secondary Radiation Emergency Medical Institutions (Related to Article 36, Paragraph 3) 1. Functions of the National Radiation Emergency Medical Center and Primary and Secondary Radiation Emergency Medical Institutions ┏━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Category │Function ┃ ┠────────┼──────────────────────────────┨ ┃National Radiation │1. Radiation Emergency Medical Care, Including Emergency Treatment for Radiation-Exposure Patients ┃ ┃Emergency Medical Center │2. Education and Training for Radiation Emergency Medical Personnel and Rescue Personnel ┃ ┃ │3. Support for Primary and Secondary Radiation Care Institutions ┃ ┃ │4. Research Related to Radiation Emergency Medical Care ┃ ┃ │5. In addition, if the head of the Emergency Medical Center deems it necessary for radiation emergency medical care ┃ ┃ │Recognized work related to radiation emergency medical care ┃ ┠────────┼──────────────────────────────┨ ┃2nd Radiation │1. Radiation Emergency Medical Care, Including Emergency Treatment for Radiation-Exposure Patients ┃ ┃Emergency Medical Institution │2. Preservation of records for radiation-exposed patients and via the emergency medical center ┃ ┃ │Report to the Nuclear Safety and Security Commission ┃ ┃ │3. Transfer patient to emergency medical center if necessary ┃ ┃ │4. Participation in Radiation Emergency Medical Training ┃ ┠────────┼──────────────────────────────┨ ┃1st Radiation │1. Radiation Emergency Medical Care, Including Emergency Treatment for Radiation-Exposure Patients ┃ ┃Emergency Medical Institution │2. Preservation of records for radiation-exposed patients and via the emergency medical center ┃ ┃ │Report to the Nuclear Safety and Security Commission ┃ ┃ │3. Transfer to an emergency medical center or secondary radiation emergency medical institution if necessary ┃ ┃ │Transfer ┃ ┃ │4. Participation in Radiation Emergency Medical Training ┃ ┗━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ 2. Designation Criteria for Primary and Secondary Radiation Emergency Medical Institutions A. Designation Criteria for Primary Radiation Emergency Medical Institutions (1) General Standard (a) Facilities and personnel capable of providing radiation emergency medical care to patients exposed to radiation and Equip with START equipment (b) Patients exposed to radiation can be treated separately from patients other than those exposed to radiation. will secure the area (c) Outpatient treatment for radiation-exposed patients shall be possible (2) Individual Standard (A) Facility Standards ┏━━━━━━━┯━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Facilities │Count│Based ┃ ┠───────┼──┼────────────────────────────┨ ┃Radiation Exposure Patient│1 │Install 1 or more beds ┃ ┃Treatment Area │ │ ┃ ┠───────┼──┼────────────────────────────┨ ┃검사실 │1 │equipment standards ┃ ┃ │ │Secure space ┃ ┠───────┼──┼────────────────────────────┨ ┃Radiology Room │1 │ ┃ ┃- General Photography Room │ │ ┃ ┠───────┼──┼────────────────────────────┨ ┃Operating Room │1 │Secure one bed capable of performing simple surgeries and treatments ┃ ┠───────┼──┼────────────────────────────┨ ┃Medical Administration Office │1 │Admission, discharge, and medical insurance separately from the relevant radiation emergency medical institution ┃ ┃ │ │If performing work, secure the necessary area ┃ ┠───────┼──┼────────────────────────────┨ ┃Congressional Office │1 │It must be a space where two or more doctors can stay and eat. ┃ ┠───────┼──┼────────────────────────────┨ ┃Guardian Waiting Room │1 │ ┃ ┠───────┼──┼────────────────────────────┨ ┃Parking Lot │ │Four or more vehicles, including two ambulances, will be parked simultaneously ┃ ┃ │ │Secure space to do so ┃ ┗━━━━━━━┷━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ Remarks If the examination room can utilize the facilities of the relevant radiation emergency medical institution, this two cannot do (B) Manpower Standards ┏━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Manpower │Remarks ┃ ┠──────────────┼────────────────────────┨ ┃ At least one physician (specialist) │ ┃ ┠──────────────┼────────────────────────┨ ┃ 3 or more nurses │ ┃ ┗━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━┛ (D) Equipment Standards ┏━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━┓ ┃equipment name │Quantity ┃ ┠───────────────┼───────────────────────┨ ┃<Medical Equipment for Radiation-Exposure Patients>│ ┃ ┠───────────────┼───────────────────────┨ ┃ Personal Dosimeter │3 ┃ ┠───────────────┼───────────────────────┨ ┃ Radiation protective suit │3 ┃ ┠───────────────┼───────────────────────┨ ┃ Radioactive waste collection bin │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Surface Contamination Meter │1 ┃ ┠───────────────┼───────────────────────┨ ┃<General Medical Equipment> │ ┃ ┠───────────────┼───────────────────────┨ ┃ cardiac defibrillator │1 ┃ ┠───────────────┼───────────────────────┨ ┃ 인공호흡기 │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Infusion Pump │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Mobile X-ray Machine │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Ultrasound Examiner │1 ┃ ┠───────────────┼───────────────────────┨ ┃ OB/GYN Examination Table │1 ┃ ┠───────────────┼───────────────────────┨ ┃ ECG Monitor │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Move Monitor │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Attachable Suction Device │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Wall Oxygen (Wall O2 unit) │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Blood warmer │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Thermal cloth │1 ┃ ┠───────────────┼───────────────────────┨ ┃ General X-ray Machine │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Ambulance. However, if the operation of the ambulance is entrusted, it must be equipped with│1 ┃ ┃cannot do. │ ┃ ┗━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━┛ B. Designation Criteria for Secondary Radiation Emergency Medical Institutions (1) General Standard (a) Facilities and personnel capable of providing radiation emergency medical care to patients exposed to radiation and Equip with START equipment (b) Patients exposed to radiation can be treated separately from patients other than those exposed to radiation. will secure the area (c) Inpatient treatment for radiation-exposed patients shall be possible (2) Individual Standard (A) Facility Standards ┏━━━━━━━━━┯━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Facilities │Count│Based ┃ ┠─────────┼──┼──────────────────────────┨ ┃Radiation Exposure Patient │1 │Can install 2 or more beds ┃ ┃Treatment Area │ │ ┃ ┠─────────┼──┼──────────────────────────┨ ┃검사실 │1 │Sufficient to perform inspection using equipment in accordance with equipment standards ┃ ┃ │ │Secure a space ┃ ┠─────────┼──┼──────────────────────────┨ ┃Radiology Room │ │ ┃ ┃- General Photography Room │1 │ ┃ ┃- CT shooting room │1 │ ┃ ┃- Film Developing Room │1 │ ┃ ┠─────────┼──┼──────────────────────────┨ ┃Operating Room │ │If there is a landing strip for rotary-wing aircraft, that landing strip and ┃ ┃- Major Operating Room │1 │Install so that it connects immediately ┃ ┃- Minor Surgery Room │1 │ ┃ ┠─────────┼──┼──────────────────────────┨ ┃ICU bed │10 │ ┃ ┠─────────┼──┼──────────────────────────┨ ┃Ward in the inpatient ward │300 │ ┃ ┠─────────┼──┼──────────────────────────┨ ┃Medical Administration Office │1 │Admission, discharge, and medical insurance separate from the relevant radiation emergency medical institution ┃ ┃ │ │When conducting experimental work, secure the necessary area. ┃ ┠─────────┼──┼──────────────────────────┨ ┃Congressional Office │1 │It must be a space where two or more doctors can stay and eat. ┃ ┠─────────┼──┼──────────────────────────┨ ┃Protection Waiting Room │1 │Secure a space where 30 or more people can wait simultaneously ┃ ┠─────────┼──┼──────────────────────────┨ ┃Parking Lot │ │Four or more vehicles, including two ambulances, parked simultaneously ┃ ┃ │ │Secure space to START ┃ ┗━━━━━━━━━┷━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━┛ Remarks Examination rooms, CT scanning rooms among radiology rooms, major operating rooms among operating rooms, intensive care units, and inpatient rooms are the relevant If the facilities of a radiation emergency medical institution can be used, it may not be provided. (B) Manpower Standards ┏━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Manpower │Remarks ┃ ┠─────────────┼─────────────────────────┨ ┃○Doctor │○Radiation emergency response in the event of a radiation disaster, etc. ┃ ┃ - Emergency Medicine, Nuclear Medicine, or Radiation Oncology│At least one medical specialist within 30 minutes ┃ ┃4 or more Western medicine specialists │Upon arrival at START, when radiation emergency medical care is possible ┃ ┃ - Radiation emergency patients in Internal Medicine and Dermatology│th ┃ ┃At least 2 specialists related to the treatment│ ┃ ┠─────────────┼─────────────────────────┨ ┃○Nurse │ ┃ ┃ - 12 or more people │ ┃ ┠─────────────┼─────────────────────────┨ ┃○Other personnel │Tailored to the actual situation of the relevant radiation emergency medical institution ┃ ┃ - Emergency Medical Technician and Driver (Ambulance 1│adjustable ┃ ┃At least 2 people per unit) │ ┃ ┃ - Radiation Safety Manager │ ┃ ┗━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━┛ . Equipment standard ┏━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━┓ ┃equipment name │Quantity ┃ ┠───────────────┼───────────────────────┨ ┃<Medical Equipment for Radiation-Exposure Patients>│ ┃ ┠───────────────┼───────────────────────┨ ┃ Personal Dosimeter │6 ┃ ┠───────────────┼───────────────────────┨ ┃ Radiation protective suit │6 ┃ ┠───────────────┼───────────────────────┨ ┃ Radioactive waste collection bin │2 ┃ ┠───────────────┼───────────────────────┨ ┃ Surface Contamination Meter │2 ┃ ┠───────────────┼───────────────────────┨ ┃<General Medical Equipment> │ ┃ ┠───────────────┼───────────────────────┨ ┃ cardiac defibrillator │2 ┃ ┠───────────────┼───────────────────────┨ ┃ Ventilator │2 ┃ ┠───────────────┼───────────────────────┨ ┃ infusion pump │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Mobile X-ray Machine │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Ultrasound Examiner (Echocardiography Capable Equipment)│1 ┃ ┠───────────────┼───────────────────────┨ ┃ Esogastric Endoscopy │1 ┃ ┠───────────────┼───────────────────────┨ ┃ OB/GYN Examination Table │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Multi-channel monitor │1 ┃ ┠───────────────┼───────────────────────┨ ┃ General Monitor │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Move Monitor │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Attachable Suction Device │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Blood warmer │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Thermal cloth │1 ┃ ┠───────────────┼───────────────────────┨ ┃ CT Camera │1 ┃ ┠───────────────┼───────────────────────┨ ┃ General X-ray Machine │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Blood Component Analyzer (CBC Analyzer) │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Blood Chemistry Analyzer │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Arterial Blood Gas Analyzer │ ┃ ┠───────────────┼───────────────────────┨ ┃ Urine Component Analyzer │1 ┃ ┠───────────────┼───────────────────────┨ ┃ BloodBank │1 ┃ ┠───────────────┼───────────────────────┨ ┃ Ambulance. However, if the operation of the ambulance is entrusted, it must be equipped with│1 ┃ ┃cannot do. │ ┃ ┗━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━┛