Annex 4 — 특수의료장비의 설치 및 운영에 관한 규칙

287043 · 2026-06-17

■ Rules on the Installation and Operation of Specialized Medical Equipment [Appendix 4] <Amended 2011.6.27> Standards for Outsourcing Quality Control Inspection Services (Related to Article 6, Paragraph 1) The quality control inspection agency for specialized medical equipment shall, for each item of the quality control inspection pursuant to Attached Table 2, A corporation, institution, or capable of evaluating and possessing expertise in quality control of specialized medical equipment As an organization, it must meet the criteria of each of the following subparagraphs. 1. Provide space necessary for evaluation, inspection, management of inspection equipment, etc. 2. Equip the following inspection equipment, etc. capable of inspecting the inspection items specified in Attached Table 2. ┌──────────────────────────────────────┐ │InspectionEquipment │ ├──────────────────────────────────────┤ │A. Standard Phantom by Medical Equipment │ │B. Reading monitor (5M pixels or more) │ │. Illuminater │ │d. Phantom for CT Dose Measurement (Abdomen, Head) │ │E. Computed Tomography CTDI Dosimeter (including electrometer, chamber) │ │B. Wired dosimeter (electrometer) for mammography devices │ │Company. Tube Voltage Meter │ │Ah. Tube Current Meter │ │. mAs measuring instrument │ │. Densitometer │ │K. Sensitometer │ │. Medical digital thermometer │ │Part. 40mesh copper mesh (Screen Film Contact Test Tool) │ │H. Reduction Acrylic Sheet (1 inch, 4 or more) │ │. Aluminum Sheet (Over 99%, for half-value layer measurement) │ │. Residual Fixing Solution Kit │ │The. Exposure time measuring device │ │. Illuminance meter │ │Mer. Luminance Meter │ │BY. Barometer[Barometer(Digital)] │ │. Sound level meter │ │Oh. Resolution chart (resolution test pattern) │ │Author. Other inspection equipment required for quality control inspection │ └──────────────────────────────────────┘ 3. Internet homepage for guiding quality control inspections, preservation, alteration, and retrieval of records A database for this purpose, capable of providing information to relevant institutions such as the Health Insurance Review & Assessment Service Equip with computer facilities 4. Employ full-time staff meeting the following criteria: a. A specialist in radiology or a major in medical physics or biomedical engineering with a bachelor's degree or higher The one who has B. At least 2 radiographers with 3 years or more of practical experience 5. The inspection equipment under Subparagraph 2 shall be managed as follows. ┌──────────────────────────────────────┐ │Inspection Equipment Management │ ├──────────────────────────────────────┤ │a. A separate control room must be provided to prevent excessive fluctuations in temperature, humidity, etc. │ │and the equipment must be stored in a way that allows for easy identification or distinction. │ │b. A history book regarding calibration and repair of inspection equipment must be maintained for each piece of inspection equipment, and │ │The following information must be recorded in the history book. │ │ 1) Instrument Specifications and Characteristics (Instrument Name, Manufacturer, Model Number, Serial Number, Year of Manufacture, Measurable│ │Range and accuracy, etc.) │ │ 2) Device History │ │ 3) Correction Date │ │ 4) Details regarding repairs │ │ 5) Management Matters (Usage Log) and Management Details │ │. Calibration shall be performed according to the internal standards for each inspection equipment, and if the calibration validity period is exceeded │ │No, it doesn't work. │ │d. At least once a year, dedicated national calibration personnel designated pursuant to Article 14 of the National Standards Framework Act │ │Must be calibrated at an institution. │ │E. When factors affecting equipment performance (overload, mishandling, repair, etc.) occur │ │or the total error of the inspection equipment exceeds 1/3 of the allowable error according to the inspection standard │ │immediately national calibration business designated pursuant to the provisions of Article 14 of the "Framework Act on National Standards" │ │Correction must be requested from a dedicated agency. │ └──────────────────────────────────────┘ 6. Quality control inspection agencies are businesses manufacturing, importing, selling, or repairing specialized medical equipment, medical device Must be a person with no conflict of interest with the officials, etc. 7. The quality control inspection agency shall have a quality assurance system, such as quality manuals and inspection work procedures Establish and maintain 8. Inspection equipment, through standard materials or calibration, [shall] the accuracy and precision of the 「National Standard Basic In order to conform to national measurement standards or international measurement standards pursuant to Article 4, subparagraph 3 of the Act, Inertia will be maintained 9. At least 20 part-time professional inspectors for each specialized medical device qualified under each of the following items Members shall be appointed. In this case, inspection members may belong to two or more quality control inspection agencies. No. a. Must have at least 2 years of experience after obtaining a board certification in Radiology. b. Complete the quality control inspection training prescribed and notified by the Minister of Health and Welfare.