Annex 44 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 44] <Newly Added 2018. 7. 11.>
Installation and Luminous Intensity Standards for Brake Lights of Micro Vehicles (Related to Article 43, Paragraph 1, Subparagraph 3)
1. Installation Standards
a. Installation Location
1) Width Direction
a) In the case where one is installed, the reference point of the brake light is within the central vertical longitudinal plane of the micro vehicle
to be located
b) In the case where two are installed, the reference point of the brake light is relative to the central vertical longitudinal section of the micro vehicle.
It will be
) Lightweight vehicles having wheels on both the left and right sides of the rear axle and a width exceeding 1,300 millimeters
The minimum distance between the light-emitting surfaces of the brake lights shall be at least 600 millimeters.
d) Lightweight vehicles having wheels on both the left and right sides of the rear axle and a width of 1,300 millimeters or less
The minimum distance between the light-emitting surfaces of the brake lights shall be at least 400 millimeters.
2) Height Direction
Must be between 250 millimeters and 1,500 millimeters above the ground
B. Observation Angle
1) The light-emitting surface of the brake light shall be observable within any range of 15 degrees upward or 15 degrees downward or less. However,
If the reference axis of the light is installed less than 750 millimeters from the ground, the light-emitting surface is the upper side
It must be observed in any range of 15 degrees or less on the lower side.
2) When one is installed, the light-emitting surface of the brake light, on the left and right sides, within a range of 45 degrees or less
will also be observed
3) If two are installed, it shall be observed within any range of 45 degrees outward and 10 degrees inward or less
. Investigation direction
The shining direction will be the rear of the car.
. Operating conditions
The brake lights shall operate in accordance with paragraphs 9 and 10 of Article 15.
2. The luminous intensity shall conform to the luminous intensity standards set forth in Subparagraph 2 of Annex 5-21 or Subparagraph 2 of Annex 6-15.