Annex 39 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙

288083 · 2026-07-10

■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 39] <Newly Added July 11, 2018> Installation and Luminous Intensity Standards for Daytime Running Lights on Micro Vehicles (Related to Article 38-4, Subparagraph 3) 1. Installation standard a. Installation Location 1) Width Direction a) One independent daytime running light shall be installed above, below, left, and right of the other front lights, respectively. It may be possible, and if other forward lights are installed vertically, the standard for daytime running lights point must be located within the central vertical longitudinal plane of the micro vehicle, and the horizontally set When installed, the reference points of the lights shall each be symmetrical to the central vertical longitudinal plane of the microcar. b) One daytime running light coupled with other front lights is the central vertical Located within the longitudinal section. However, if the daytime running lights are installed horizontally with other front lights In the case where the reference points of the lights are each symmetrical to the central vertical longitudinal plane of the microcar, thing ) When installing two daytime running lights, the reference point for the lights is the vertical center of the micro vehicle Must be symmetrical to the longitudinal section d) In cases where the width of a microcar exceeds 1,300 millimeters, the smallest gap between the light-emitting surfaces of the daytime running lights The distance shall be at least 500 millimeters. 2) Height Direction Be between 250 millimeters and 1,500 millimeters above the ground 3) Length direction Daytime running lights must be located at the front of the micro vehicle and, when illuminated, the reflection of the vehicle surface It shall be a structure that does not directly or indirectly interfere with driving by the START part or rearview mirror. b. In cases where the distance between the daytime running lights and turn signals is 40 millimeters or less, the main lights installed on each side The intermittent running lights are turned off or dimmed to 140 candela or less while the turn signals are activated. . . Observation angle 1) The light-emitting surface of the daytime running lights shall be visible within any range of 10 degrees upward or 10 degrees downward or less 2) In the case of a single light, the light-emitting surface of the daytime running light shall be within a range of 20 degrees or less on the left and right sides . However, if two are installed, the light-emitting surface of the daytime running lights shall be 20 degrees outward, It must be observed in any range of 20 degrees or less internally. . Direction of investigation The illuminating direction shall be the front of the vehicle. However, changes in the illumination direction depending on steering may be permitted. . E. Operating Conditions 1) The daytime running lights shall automatically illuminate when the ignition key is in the engine operating position. may be turned off if any of the following apply. a) When the automatic transmission control is in the parking position b) When the parking brake is engaged ) Before first movement after starting the engine 2) When the vehicle speed is 10 kilometers per hour or less, the daytime running lights can be manually turned off is available, provided that the speed of the vehicle exceeds 10 kilometers per hour or travels more than 100 meters The daytime running lights must automatically turn on at START. 3) The daytime running lights shall be turned off in any of the following cases: a) When the vehicle is stopped by the ignition key b) When the front fog lights are illuminated ) When the headlights are illuminated. However, when the driving beam of the headlights is temporarily used as a warning indicator This shall not apply in such cases. bar. A display device indicating the operating status of the daytime running lights can be installed. 2. The luminous intensity shall conform to the luminous intensity standards pursuant to Subparagraph 2 of Attached Table 6.8