Annex 28 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 28-2] <Amended June 10, 2014>
Luminous Intensity Standards for Light Indicators on Passenger Vehicles for Transporting Children (Article 48, Paragraph 4, Subparagraph 6
related)
1. The minimum luminous intensity at each measurement point shall be greater than or equal to the minimum luminous intensity in the following table.
┏━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Measuring point │Minimum luminous intensity (candela: cd) ┃
┃ ├──┬───────────────────────────────┨
┃ │Red│Yellow ┃
┠──┬──┼──┼───────────────────────────────┨
┃10U │5L │20 │50 ┃
┃ │ │ │ ┃
┃ │V │50 │125 ┃
┃ │ │ │ ┃
┃ │5R │20 │50 ┃
┠──┼──┼──┼───────────────────────────────┨
┃5U │20L │150 │375 ┃
┃ │ │ │ ┃
┃ │10L │300 │750 ┃
┃ │ │ │ ┃
┃ │5L │300 │750 ┃
┃ │ │ │ ┃
┃ │V │300 │750 ┃
┃ │ │ │ ┃
┃ │5R │300 │750 ┃
┃ │ │ │ ┃
┃ │10R │300 │750 ┃
┃ │ │ │ ┃
┃ │20R │150 │375 ┃
┠──┼──┼──┼───────────────────────────────┨
┃H │30L │30 │75 ┃
┃ │ │ │ ┃
┃ │20L │180 │450 ┃
┃ │ │ │ ┃
┃ │10L │400 │1000 ┃
┃ │ │ │ ┃
┃ │5L │500 │1250 ┃
┃ │ │ │ ┃
┃ │V │600 │1500 ┃
┃ │ │ │ ┃
┃ │5R │500 │1250 ┃
┃ │ │ │ ┃
┃ │10R │400 │1000 ┃
┃ │ │ │ ┃
┃ │20R │180 │450 ┃
┃ │ │ │ ┃
┃ │30R │30 │75 ┃
┠──┼──┼──┼───────────────────────────────┨
┃5D │30L │30 │75 ┃
┃ │ │ │ ┃
┃ │20L │200 │500 ┃
┃ │ │ │ ┃
┃ │10L │300 │750 ┃
┃ │ │ │ ┃
┃ │5L │450 │1125 ┃
┃ │ │ │ ┃
┃ │V │450 │1125 ┃
┃ │ │ │ ┃
┃ │5R │450 │1125 ┃
┃ │ │ │ ┃
┃ │10R │300 │750 ┃
┃ │ │ │ ┃
┃ │20R │200 │500 ┃
┃ │ │ │ ┃
┃ │30R │30 │75 ┃
┠──┼──┼──┼───────────────────────────────┨
┃10D │5L │40 │100 ┃
┃ │ │ │ ┃
┃ │V │40 │100 ┃
┃ │ │ │ ┃
┃ │5R │40 │100 ┃
┗━━┷━━┷━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
2. The sum of the minimum luminous intensities at each measurement point shall be greater than or equal to the sum of the minimum luminous intensities in the following table (each side
The minimum luminance at the vertex must be at least 60 percent of the minimum luminance according to the table above)
┏━━┯━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃zone│Measurement point(degrees)│Sum of minimum luminous intensities (candela: cd) ┃
┃ │ ├──┬─────────────────────────┨
┃ │ │Red│Yellow ┃
┠──┼─────┼──┼─────────────────────────┨
┃1 │H 30L │590 │1475 ┃
┃ │ │ │ ┃
┃ │5D 30L │ │ ┃
┃ │ │ │ ┃
┃ │5U 20L │ │ ┃
┃ │ │ │ ┃
┃ │H 20L │ │ ┃
┃ │ │ │ ┃
┃ │5D 20L │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃2 │10U 5L │90 │225 ┃
┃ │ │ │ ┃
┃ │10U V │ │ ┃
┃ │ │ │ ┃
┃ │10U 5R │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃3 │5U 10L │1500│3750 ┃
┃ │ │ │ ┃
┃ │5U 5L │ │ ┃
┃ │ │ │ ┃
┃ │5U V │ │ ┃
┃ │ │ │ ┃
┃ │5U 5R │ │ ┃
┃ │ │ │ ┃
┃ │5U 10R │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃4 │H 10L │2400│6000 ┃
┃ │ │ │ ┃
┃ │H 5L │ │ ┃
┃ │ │ │ ┃
┃ │H V │ │ ┃
┃ │ │ │ ┃
┃ │H 5R │ │ ┃
┃ │ │ │ ┃
┃ │H 10R │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃5 │5D 10L │1950│4875 ┃
┃ │ │ │ ┃
┃ │5D 5L │ │ ┃
┃ │ │ │ ┃
┃ │5D V │ │ ┃
┃ │ │ │ ┃
┃ │5D 5R │ │ ┃
┃ │ │ │ ┃
┃ │5D 10R │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃6 │10D 5L │120 │300 ┃
┃ │ │ │ ┃
┃ │10D V │ │ ┃
┃ │ │ │ ┃
┃ │10D 5R │ │ ┃
┠──┼─────┼──┼─────────────────────────┨
┃7 │5U 20R │590 │1475 ┃
┃ │ │ │ ┃
┃ │H 20R │ │ ┃
┃ │ │ │ ┃
┃ │5D 20R │ │ ┃
┃ │ │ │ ┃
┃ │H 30R │ │ ┃
┃ │ │ │ ┃
┃ │5D 30R │ │ ┃
┗━━┷━━━━━┷━━┷━━━━━━━━━━━━━━━━━━━━━━━━━┛