Annex 24 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 24] <Amended June 5, 2026>
Electromagnetic Compatibility Standards (Related to Article 107)
1. Electromagnetic Radiation Standards
a. Broadband Radiation Standard
┏━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Section │Test Frequency (MHz) ┃
┃ ├─────────┬─────────┬──────┨
┃ │30 ~ 75 │75 ~ 400 │400 ~ 1000 ┃
┠───┬───────┼─────────┼─────────┼──────┨
┃Automobile│10 meter standard value │36 │36+15.13log(f/75) │47 ┃
┃ │(㏈㎶/m) │ │ │ ┃
┃ ├───────┼─────────┼─────────┼──────┨
┃ │3 meter standard value │46 │46+15.13log(f/75) │57 ┃
┃ │(㏈㎶/m) │ │ │ ┃
┠───┴───────┼─────────┼─────────┼──────┨
┃Automotive's │66-25.13log(f/30) │56+15.13log(f/75) │67 ┃
┃Electrical·Electronic Devices │ │ │ ┃
┃Unit Part │ │ │ ┃
┗━━━━━━━━━━━┷━━━━━━━━━┷━━━━━━━━━┷━━━━━━┛
Note) 1. Apply one of the reference values of 10 meters or 3 meters, where f refers to the test frequency.
The following are the same as in this table.
The above standards apply primarily to automobiles, and if the automobile standards are satisfied, the relevant automatic
Unit components of electrical and electronic devices installed in vehicles are also deemed to comply with the standards.
is the same as in this table.
B. Narrowband Radiation Standard
┏━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Classification │Test Frequency (MHz) ┃
┃ ├──────────┬───────────────┨
┃ │30 ~ 230 │230 ~ 1000 ┃
┠───┬────────┼──────────┼───────────────┨
┃Automobile│10 meter standard value │32 │39 ┃
┃ │(㏈㎶/m) │ │ ┃
┃ ├────────┼──────────┼───────────────┨
┃ │3 meter reference value │42 │49 ┃
┃ │(㏈㎶/m) │ │ ┃
┣━━━┷━━━━━━━━┿━━━━━━━━━━┷━━━━━━━━━━━━━━━┫
┃Electronic and electronic devices of automobiles │Test Frequency (MHz) ┃
┃Unit Part ├─────────┬─────────┬──────┨
┃ │30 ∼ 75 │75 ∼ 400 │400 ∼ 1000 ┃
┃ ├─────────┼─────────┼──────┨
┃ │56-25.13log(f/30) │46+15.13log(f/75) │57 ┃
┗━━━━━━━━━━━━┷━━━━━━━━━┷━━━━━━━━━┷━━━━━━┛
Note) If the oscillation frequency of an electrical or electronic device installed in a vehicle is less than 9 kHz, or 76 MHz to 108
MHz frequency range, the reference
.
2. Electromagnetic Immunity Standards
┏━━━━━┯━━━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━┓
┃ApplicableTarget │Test Conditions │Based ┃
┃ ├──────┬──────────────┤ ┃
┃ │FrequencyRange │Radio wave strength (effective value) │ ┃
┠─────┼──────┼──────────────┼──────────────┨
┃Automobile │20~2,000 ㎒│24 V/m │○ Related to direct control of automobiles┃
┠─────┼──────┼──────────────┤There should be no abnormalities in the START function ┃
┃Automotive │20~2,000 ㎒│a. Electromagnetic radiation: 24V/m │Driver, passenger, or other driver┃
┃Electrical·Electronics│ │B. 150mm strip line: 48V/m │Functions related to electronic protection ┃
┃Device │ │. 800mm strip line: 12V/m │There should be no issues with START ┃
┃Unit Part │ │. TEM cell: 60V/m │○ to the driver or another driver ┃
┃ │ │E. BCI (Bulk Current Application): 48mA │A field that may cause confusion ┃
┃ │ │ │shall not cause harm ┃
┃ │ │ │○ Vehicle data transmission system ┃
┃ │ │ │Legal data of items and automobiles ┃
┃ │ │ │Functions affecting the ┃
┃ │ │ │or more is There won't be ┃
┗━━━━━┷━━━━━━┷━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━┛
Note) 1. The immunity test of unit components of electrical and electronic devices in automobiles is part (a) of the radio wave intensity column
You can select and test one or more methods from items 1 to 2.
2. For automotive testing, the radio wave intensity for more than 90% of the frequency range is 24V/m
, and the minimum signal strength in the frequency range must be 20V/m or higher.
3. In the case of testing unit components of electrical and electronic devices in automobiles, 90% or more of the frequency range
to The strength of the radio wave is equal to the strength of the table item, and in the frequency range, the minimum
The intensity of the waves is 20V/m for electromagnetic radiation, 40V/m for a 150mm strip line, and 800mm
The trip line is 10 V/m, the TEM cell is 50 V/m, and the bulk current input (BCI) is 40 mA.
.
3. Standards for Electric Vehicle Charging
a. Broadband Radiation Standard
┌─────────────────┬─────────────────────┐
│Section │Test Frequency (MHz) │
│ ├────┬─────────┬──────┤
│ │30 ∼ 75│75 ∼ 400 │400 ∼ 1000 │
├─────┬───────────┼────┼─────────┼──────┤
│ElectricVehicle│10-meter standard value(dBμV/m) │36 │36+15.13log(f/75) │47 │
│ ├───────────┼────┼─────────┼──────┤
│ │3 meter reference value(dBμV/m) │46 │46+15.13log(f/75) │57 │
└─────┴───────────┴────┴─────────┴──────┘
Note) Apply one of the reference values of 10 meters or 3 meters, where f refers to the test frequency.
B. Electromagnetic Immunity Standards
┌──────┬─────────────┬────────────────┐
│Apply │Test Conditions │기 jun │
│Target ├──────┬──────┤ │
│ │FrequencyRange │Radio wave strength │ │
│ │ │(effective value) │ │
├──────┼──────┼──────┼────────────────┤
│Electric Vehicle │20∼2,000 ㎒│24 V/m │The car does not operate unintentionally │
│ │ │ │thingNotToDo │
└──────┴──────┴──────┴────────────────┘
Note) The radio wave strength for more than 90% of the frequency range is 24V/m, and in the frequency range
must be 20V/m or higher.
. AC Power Line Harmonic Standard
1) Equivalent input current 16 A or less
┌────────┬────────────┐
│Harmonic order n │Maximum allowable harmonic current A │
┝━━━━━━━━┷━━━━━━━━━━━━┥
│Odd Harmonics │
├────────┬────────────┤
│3 │2.3 │
├────────┼────────────┤
│5 │1.14 │
├────────┼────────────┤
│7 │0.77 │
├────────┼────────────┤
│9 │0.40 │
├────────┼────────────┤
│11 │0.33 │
├────────┼────────────┤
│13 │0.21 │
├────────┼────────────┤
│15 ≤ n ≤ 39 │0.15 x 15/n │
┝━━━━━━━━┷━━━━━━━━━━━━┥
│Even Harmonics │
├────────┬────────────┤
│2 │1.08 │
├────────┼────────────┤
│4 │0.43 │
├────────┼────────────┤
│6 │0.30 │
├────────┼────────────┤
│8 ≤ n ≤ 40 │0.23 x 8/n │
└────────┴────────────┘
2) Equivalent input current exceeding 16 A and 75 A or less (excluding balanced 3-phase equipment)
┌───┬─────────────────┬─────────────────┐
│Minimum │Individual allowable maximum harmonic current │Max Current │
│paragraph │ In/I1 % │Harmonic Rate % │
│CircuitRatio│ │ │
│(Rsce)│ │ │
├───┼──┬──┬──┬──┬──┬──┼────┬────────────┤
│ │I3 │I5 │I7 │I9 │I11 │I13 │Full Harmonic│Partial Weighting │
│ │ │ │ │ │ │ │DistortionRate │Harmonic │
│ │ │ │ │ │ │ │(THD) │DistortionRate │
│ │ │ │ │ │ │ │ │(PWHD) │
├───┼──┼──┼──┼──┼──┼──┼────┼────────────┤
│33 │21.6│10.7│7.2 │3.8 │3.1 │2 │23 │23 │
├───┼──┼──┼──┼──┼──┼──┼────┼────────────┤
│66 │24 │13 │8 │5 │4 │3 │26 │26 │
├───┼──┼──┼──┼──┼──┼──┼────┼────────────┤
│120 │27 │15 │10 │6 │5 │4 │30 │30 │
├───┼──┼──┼──┼──┼──┼──┼────┼────────────┤
│250 │35 │20 │13 │9 │8 │6 │40 │40 │
├───┼──┼──┼──┼──┼──┼──┼────┼────────────┤
│≥350 │41 │24 │15 │12 │10 │8 │47 │47 │
├───┴──┴──┴──┴──┴──┴──┴────┴────────────┤
│Note) 1. The relative value of even-order harmonics of the 12th order or lower must be less than 16/n %. │
│ 2. 12th order in Total Harmonic Distortion (THD) and Partially Weighted Harmonic Distortion (PWHD) │
│Even harmonics are calculated in the same way as odd harmonics. │
│ 3. Linear interpolation is applied to consecutive short-circuit ratio (Rsce) values. │
└───────────────────────────────────────┘
3) Balanced 3-phase equipment with equivalent input current exceeding 16 A and up to 75 A
┌───┬─────────────┬────────────────────┐
│Minimum │Individual allowable maximum harmonic current │Max Current │
│paragraph │ In/I1 % │Harmonic Rate % │
│CircuitRatio│ │ │
│(Rsce)│ │ │
├───┼──┬──┬──┬────┼─────┬──────────────┤
│ │I5 │I7 │I11 │I13 │Full Harmonic Why│Partial Weighting │
│ │ │ │ │ │curvature │Harmonic │
│ │ │ │ │ │(THD) │DistortionRate │
│ │ │ │ │ │ │(PWHD) │
├───┼──┼──┼──┼────┼─────┼──────────────┤
│33 │10.7│7.2 │3.1 │2 │13 │22 │
├───┼──┼──┼──┼────┼─────┼──────────────┤
│66 │14 │9 │5 │3 │16 │25 │
├───┼──┼──┼──┼────┼─────┼──────────────┤
│120 │19 │12 │7 │4 │22 │28 │
├───┼──┼──┼──┼────┼─────┼──────────────┤
│250 │31 │20 │12 │7 │37 │38 │
├───┼──┼──┼──┼────┼─────┼──────────────┤
│≥350 │40 │25 │15 │10 │48 │46 │
├───┴──┴──┴──┴────┴─────┴──────────────┤
│Note) 1. The relative value of even-order harmonics of the 12th order or lower must be less than 16/n %. │
│ 2. 12th order in Total Harmonic Distortion (THD) and Partially Weighted Harmonic Distortion (PWHD) │
│are calculated in the same way as odd harmonics. │
│ 3. Linear interpolation is applied to consecutive short-circuit ratio (Rsce) values. │
└──────────────────────────────────────┘
4) Equivalent input current exceeding 16 A, 75 A or less, balanced 3-phase equipment under specific conditions
┌───┬─────────────┬────────────────────┐
│Minimum │Individual allowable maximum harmonic current │Max Current │
│paragraph │ In/I1 % │Harmonic Rate % │
│CircuitRatio│ │ │
│(Rsce)│ │ │
├───┼──┬──┬──┬────┼────┬───────────────┤
│ │I5 │I7 │I11 │I13 │Full Harmonic│Partial Weighting │
│ │ │ │ │ │DistortionRate │Harmonic │
│ │ │ │ │ │(THD) │DistortionRate │
│ │ │ │ │ │ │(PWHD) │
├───┼──┼──┼──┼────┼────┼───────────────┤
│33 │10.7│7.2 │3.1 │2 │13 │22 │
├───┼──┼──┼──┼────┼────┼───────────────┤
│≥120 │40 │25 │15 │10 │48 │46 │
├───┴──┴──┴──┴────┴────┴───────────────┤
│Note) 1. The relative value of even-order harmonics of the 12th order or lower must be less than 16/n %. │
│ 2. 12th order in Total Harmonic Distortion (THD) and Partially Weighted Harmonic Distortion (PWHD) │
│are calculated in the same way as odd harmonics. │
│ 3. Linear interpolation is applied to consecutive short-circuit ratio (Rsce) values. │
└──────────────────────────────────────┘
. Standards for Voltage Change, Fluctuation, and Flicker in AC Power Lines
┌───────────────┬──────┐
│parameter variable │기 jun │
├───────────────┼──────┤
│Short-term Flicker Value(Pst) │1.0 or less │
├───────────────┼──────┤
│Long-term Flicker Value(Plt) │0.65 or less │
├───────────────┼──────┤
│The voltage change value (d(t)) is 3.3% │500 ms or less │
│time exceeding (Tmax) │ │
├───────────────┼──────┤
│Relative steady-state voltage change (dc) │3.3 % or less │
└───────────────┴──────┘
E. Standards for Conducted Interference in AC and DC Power Lines
1) AC Power Line
┌──────┬─────────────┐
│Frequency(MHz) │Maximum Allowable Limit (Detector) │
├──────┼─────────────┤
│0.15 ∼ 0.5 │66 ∼ 56 dBμV (quasi-peak) │
│ │ 56 ∼ 46 dBμV (average value) │
├──────┼─────────────┤
│0.5 ∼ 5 │56 dBμV (quasi-peak) │
│ │46 dBμV (Average) │
├──────┼─────────────┤
│5 ∼ 30 │60 dBμV (quasi-peak) │
│ │ 50 dBμV (average value) │
└──────┴─────────────┘
2) DC Power Line
┌──────┬─────────────────────────────────┐
│Frequency(MHz) │Maximum Allowable Limit (Detector) │
├──────┼─────────────────────────────────┤
│0.15 ∼ 0.5 │79 dBμV (quasi-peak) │
│ │66 dBμV (average value) │
├──────┼─────────────────────────────────┤
│0.5 ∼ 30 │73 dBμV (quasi-peak) │
│ │ 60 dBμV (average value) │
├──────┴─────────────────────────────────┤
│Note) DC charging cable length is 30 meters or less or DC charging exclusively for electric vehicles│
│Does not apply in the case of a START. │
└────────────────────────────────────────┘
Bar. Charging Communication Line Conduction Interference Standards
┌──────┬──────────────┬──────────────────┐
│Frequency(MHz) │Maximum Allowable Voltage Reference Value (Detector) │Maximum Allowable Current Reference Value (Detector) │
├──────┼──────────────┼──────────────────┤
│0.15 ∼ 0.5 │84∼74 dBμV (quasi-peak) │40∼30 dBμA (quasi-peak) │
│ │74∼64 dBμV (Average) │30∼20 dBμA (Average) │
├──────┼──────────────┼──────────────────┤
│0.5 ∼ 30 │74 dBμV (quasi-peak) │30 dBμA (quasi-peak) │
│ │ 64 dBμV (average value) │ 20 dBμA (average value) │
├──────┴──────────────┴──────────────────┤
│Note) Not applicable if Power Line Communication (PLC) or external communication network services are not included │
│. │
└────────────────────────────────────────┘
Company. AC and DC Power Line Transient Conduction Immunity Standards
┌──┬────────────────────┬─────────────────┐
│Apply│Test Conditions │기 jun │
│Target├─────┬────────┬─────┤ │
│ │Is it voltage │Rise(Tr) / Hold │AuthorRetrieval │ │
│ │ │(Th) time │ │ │
├──┼─────┼────────┼─────┼─────────────────┤
│AC, │± 2kV │5 ns / 50 ns │5 kHz │ unally a car │
│DC │ │ │(1 min or more)│Will not operate │
├──┴─────┴────────┴─────┴─────────────────┤
│ Note) DC charging cable length is 30 meters or less, or DC charging exclusively for electric vehicles │
│In the case of the START device, direct current (DC) is not applied. │
└─────────────────────────────────────────┘
A. AC and DC Power Line Surge Conduction Immunity Standards
┌──┬──────────────────────────────────┬─────────┐
│Type│Test Conditions │기 jun │
│ ├───────────┬──────┬─────────┬─────┤ │
│ │Is it voltage │Rise(Tr) / │or Phase │AuthorRetrieval /│ │
│ │ │Maintain(Th) │ │Interval │ │
│ │ │TIME │ │ │ │
├──┼───────────┼──────┼─────────┼─────┼─────────┤
│AC │ Wire and Ground: ± 2kV │1.2 us / │0, 90, 180, 270° │5 times / │ Unintentionally │
│ │ line to line: ± 1kV │50 us │ │Within 1 minute │The car is not working │
├──┼───────────┼──────┼─────────┼─────┤thingNotToDo │
│DC │ Wire and Ground: ± 0.5kV │1.2 us / │- │5 times / │ │
│ │ Line to line: ± 0.5kV │50 us │ │Within 1 minute │ │
├──┴───────────┴──────┴─────────┴─────┴─────────┤
│ Note) DC charging cable length is 30 meters or less, or DC charging exclusively for electric vehicles │
│In the case of the START device, direct current (DC) is not applied. │
└───────────────────────────────────────────────┘