Annex 6 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 6-15] <Amended June 5, 2026>
Installation and Luminous Intensity Standards for Brake Lights (Related to Article 43, Paragraph 1, Subparagraph 3)
1. Installation Standards for Brake Lights
a. Installation Location
1) Width Direction
a) In the case of passenger cars, cargo vehicles with a gross vehicle weight of 3.5 tons or less, and special vehicles, braking
The outer edge of the light-emitting surface of the START, etc. shall be 400 millimeters or less from the outermost edge of the vehicle.
b) Excluding passenger cars, cargo vehicles with a gross vehicle weight of 3.5 tons or less, and special vehicles
In the case of a train, the installation distance between the light-emitting surfaces of both brake lights in the direction of the reference axis is 600 millimeters.
It must be at least 1 meter. However, for vehicles with a width of less than 1,300 millimeters, it must be 400 millimeters or less.
must be.
2) Height Direction
a) The light-emitting surface of the brake light shall be between 350 millimeters and 1,500 millimeters above the ground in the unladen state
It shall be. However, if impossible due to the vehicle body structure, it may be installed at a distance of 2,100 millimeters or less.
There is.
b) In cases where additional brake lights are installed, they shall be installed symmetrically on the left and right to conform to a),
It must be, and the vertical distance from the mandatory brake lights must be at least 600 millimeters.
3) Length Direction
Install on the rear of the vehicle
B. Observation Angle
1) Horizontal Angle
The light-emitting surface of the brake light shall be visible from an angle of 45 degrees to the left and 45 degrees to the right or less. However, on the ground
If installed less than 750 millimeters from the START, the light-emitting surface shall be 20 degrees or less inward below the horizontal plane.
must be observable in any range.
2) Vertical Angle
a) The light-emitting surface of the brake light shall be visible from an angle of 15 degrees upward and 15 degrees downward or less. However,
, the light-emitting surface shall be 5 degrees or less downward
It must be observable even in the START range.
b) In the case of an additional brake light installed more than 2,100 millimeters above the ground, the light-emitting surface is the upper
It must be observable in any range below 5 degrees.
. The direction the brake lights are shining is the rear of the car
. Operating conditions
1) The brake lights shall operate in accordance with paragraphs 9 and 10 of Article 15
2) The brake lights may not illuminate if the prime mover is not operating.
E. Display Device
A display device indicating the operating status can be installed, and in this case, when a brake light malfunction occurs,
A non-flashing fault indicator must be installed.
bar. Other standards
Brake lights apply variable light intensity control depending on various environmental conditions and contamination of the light-emitting surface, etc.
can be possible
2. Luminous Intensity Standards for Brake Lights
a. Maximum and minimum luminous intensity
┌────┬────┬──────────┐
│old minute │MINMOluminance│Maximum Luminous Intensity (cd) │
│ │(candela)├─────┬────┤
│ │ │Single Equalization │D-Equalize │
├────┼────┼─────┼────┤
│Fixed Luminous Intensity│60 or more │260 or less │130 or less│
├────┼────┼─────┼────┤
│Variable Luminous Intensity│60 or more │730 or less │365 or less│
└────┴────┴─────┴────┘
(Note)
1. A D-light is a combination of two independent lights having the same function, any of the following
Can be installed to satisfy one condition.
a. The minimum rectangle in which the total area of the projection planes in the direction of the reference axis encloses the projection planes
It must be at least 60 percent of the area of the START type.
a. The tangent distance between two projected separate planes is 75 millimeters or less in the direction of the reference axis
should.
2. Fixed luminous intensity refers to a brake light that provides a fixed luminous intensity.
3. Variable luminous intensity refers to a brake light whose luminous intensity changes according to operating conditions.
B. Minimum luminous intensity of measurement points and measurement zones
┌────────────┬────┐
│Measurement point and measurement area (angle)│luminance(cd)│
├────┬───────┼────┤
│H │10L, 10R │21 or more │
│ ├───────┼────┤
│ │5L, 5R │54 or higher │
│ ├───────┼────┤
│ │V │60 or more │
├────┼───────┼────┤
│5U, 5D │20L, 20R │6 or higher │
│ ├───────┼────┤
│ │10L, 10R │12 or higher │
│ ├───────┼────┤
│ │V │42 or higher │
├────┼───────┼────┤
│10U, 10D│5L, 5R │12 or higher │
├────┴───────┼────┤
│Within observation angle range │0.3 or higher│
└────────────┴────┘
Note)
The luminous intensity standard for brake lights of mass-produced vehicles may have a deviation of ±20 percent or less. However,
The minimum luminous intensity within the observation angle range must be at least 0.2 cd.