Annex 6 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 6-12] <Amended June 5, 2026>
Installation and Luminous Intensity Standards for End Indicator Lights (Related to Article 40-2, Paragraph 1, Subparagraph 3)
1. Installation Standards for End Indicator Lights
a. Installation Location
1) Width Direction
a) The end indicator light shall be installed at the outermost end of the vehicle.
b) The outer edge of the light-emitting surface of the end indicator light is 400 millimeters or less from the outermost edge of the vehicle.
thing
2) Height Direction
a) End indicator light with a light-emitting surface facing forward (White end indicator light)
(1) In the direction of the reference axis, the uppermost part of the light-emitting surface of the end indicator light is the transparent area of the front window glass
Install higher than the top
(2) The towed vehicle is positioned vertically at the top center of the vehicle, taking into account the body structure and operating conditions.
Install so as to be symmetrical to the left and right with respect to the longitudinal section.
b) End indicator light with the light-emitting surface facing the rear (red end indicator light)
Considering the vehicle body structure and operating conditions, based on the vertical longitudinal section at the center of the vehicle at the top
so that it is symmetrical on the left and right
d) Additional end indicator lights installed should, considering the vehicle body structure and operating conditions, as much as possible
Install by separating
3) Length Direction
In the case of additionally installing end indicator lights with a light-emitting surface facing forward, adjacent to the rear of the vehicle
It must be installed properly, and the distance from the end of the vehicle must be 400 millimeters or less.
B. Observation Angle
1) To be observed in any range of 80 degrees or less externally
2) To be observed in any range of 5 degrees above and 20 degrees below
The direction of the end indicator light shall be suitable for the observation angles of the front and rear sides.
. Operating conditions
It shall be structured to illuminate and extinguish simultaneously with the taillights, parking lights, side indicator lights, and license plate lights.
E. Display Device
A display device indicating the operating status can be installed, and the display devices for the side marker lights and taillights can be installed.
.
bar. Other standards
1) White and red end indicator lights shall be installed separately; however, if installed together, one unit
can be combined with
The shortest distance between the end indicator light and the illuminated surface of the side marker light or taillight is 200 millimeters.
It will be an award
3) The white end indicator light additionally installed on the towed vehicle is the indirect clockwork of the towing vehicle
Install at a location observable by the START value.
4) It shall be a structure in which the white and red end indicator lights operate simultaneously
2. Luminous Intensity Standards for End Indicator Lights
a. Maximum and minimum luminous intensity
┌─────────────┬────┬──────────┐
│old minute │MINMOluminance│Maximum Luminous Intensity (cd) │
│ │(candela)├─────┬────┤
│ │ │Single Equalization │D-Equalize │
├─────────────┼────┼─────┼────┤
│End Indicator Light (White) │4 or higher │140 or less │70 or less │
├────────┬────┼────┼─────┼────┤
│End indicator light (red)│Fixed Luminous Intensity│4 or higher │17 and below │8.5 or less│
│ ├────┼────┼─────┼────┤
│ │Variable Luminous Intensity│4 or higher │42 or less │21 or less │
└────────┴────┴────┴─────┴────┘
(Note)
1. A D-light is a combination of two independent lights having the same function, any of the following
Can be installed to satisfy one condition.
a. The minimum rectangle in which the total area of the projection planes in the direction of the reference axis encloses the projection planes
It must be at least 60 percent of the type area.
a. The tangent distance between two projected separate planes is 75 millimeters or less in the direction of the reference axis.
must be.
2. Fixed luminous intensity refers to an end indicator light that provides a fixed luminous intensity.
3. Variable luminous intensity refers to an end indicator light whose luminous intensity changes according to operating conditions.
B. Minimum luminous intensity of measurement points and measurement zones
┌────────────┬─────┐
│Measurement point and measurement area (angle)│luminance(cd) │
├────┬───────┼─────┤
│H │10L, 10R │1.4 or higher │
│ ├───────┼─────┤
│ │5L, 5R │3.6 or higher │
│ ├───────┼─────┤
│ │V │4 or higher │
├────┼───────┼─────┤
│5U, 5D │20L, 20R │0.4 or higher │
│ ├───────┼─────┤
│ │10L, 10R │0.8 or higher │
│ ├───────┼─────┤
│ │V │2.8 or higher │
├────┼───────┼─────┤
│10U, 10D│5L, 5R │0.8 or higher │
├────┴───────┼─────┤
│Within observation angle range │0.05 or more │
└────────────┴─────┘
(Note)
The luminous intensity standard of end indicator lights for mass-produced vehicles may have a deviation of ±20 percent or less.
However, the minimum luminous intensity within the observation angle range must be 0.03 cd or higher.