Annex 6 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙

288083 · 2026-07-10

■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 6-8] <Amended June 5, 2026> Installation and Luminous Intensity Standards for Daytime Running Lights (Related to Article 38-4, Subparagraph 3) 1. Installation Standards for Daytime Running Lights a. Installation Location 1) Width Direction The distance between the light-emitting surfaces of the daytime running lights shall be at least 600 millimeters. However, the vehicle's overall width... 1, If ​​300 millimeters or less, be 400 millimeters or more 2) Height Direction The light-emitting surface shall be between 250 millimeters and 1,500 millimeters above the ground in the unladen state. B. Observation Angle The light-emitting surface is within any range of 10 degrees upward, 10 degrees downward, 20 degrees outward, or 20 degrees inward or less. willbeobserved . Investigation direction The shining direction should be the front of the vehicle. . Display device An illuminated indicator device that shows the operating status can be installed. In this case, the daytime running lights If the fault status of light sources, etc., needs to be indicated, install a separate fault detection system. must be installed. E. Operating Conditions 1) A device for starting and stopping a prime mover and a power transmission device When set to the operable state, the daytime running lights should turn on automatically. Notwithstanding 1), in cases corresponding to any one or more of the following, the extinguishing of the daytime running lights It can maintain the START state or be turned off manually even if it has been lit automatically. a) When the automatic transmission control is in the park position b) When the parking brake is engaged ) Manually operating a device that starts or stops a prime mover and power transmission device , if the vehicle has not yet started driving d) In the case of speeds of 15 kilometers per hour or less 3) When all extinguishing conditions applied according to 2) are released, the daytime running lights, according to 1), i.e., MTQd8df0be14960cfb800296 Will automatically light up at START 4) 1), if the prime mover and power transmission system are in a state where they cannot operate or the following The daytime running lights must automatically turn off in any of the following cases. a) When the front fog lights are illuminated or) when the headlights are manually turned on (in cases where they are used intermittently for a short time, Except) c) In the case where the conversion beam headlight is automatically illuminated in accordance with Subparagraph 4, Item 1 of Attached Table 6-4 When the daytime running lights are illuminated, the taillights must also be illuminated, and the side marker lights and end indicator lights Side indicator lights and license plate lights may be illuminated optionally. However, taillights and parking lights/ End indicator lights, side indicator lights, and number lights are ambient illumination [Note to Table 6-4, Item 1, Subparagraph (d), 4) [Referring to the illuminance measured according to START1 and 2] may be turned off if it is 7,000 lux or higher. 6) The daytime running lights are not coupled with the front turn signals, and in the reference axis direction, the front direction A light in which the shortest distance between each light-emitting surface of the turn signal and the daytime running light is 40 millimeters or less Right, the operating conditions of the daytime running lights must satisfy any one of the following. However, on the HV side When the luminous intensity of the front turn signals at the apex is 150% or more of the luminous intensity of the daytime running lights is excluded. a) While the front turn signal is operating (including the entire flashing cycle), the main on the relevant side Intermediate running lights will all be turned off b) While the front turn signal is operating (including the entire flashing cycle), the main The luminous intensity of the intermittent running lights shall decrease to 140 cd or less within the observation angle range. 7) When the daytime running lights are coupled with the front turn signals, the operating conditions of the daytime running lights are Must satisfy any one of the following. a) In cases where the daytime running lights completely share a light-emitting surface with the front turn signals, the front While the turn signal is operating (including the entire flashing cycle), the daytime running light on the relevant side The lights will be turned off b) In cases where the daytime running lights and front turn signals partially share a light-emitting surface Satisfy any one of the following (1) While the front turn signal is operating (including the entire flashing cycle), the main Intermediate running lights will all be turned off (2) For Category 1a or 1b, the corresponding front turn signal operates (the entire flashing cycle ), the shared area is turned off, and the non-shared area is observed at the angle will also decrease to 140cd or less within the area 2. Luminous Intensity Standards for Daytime Running Lights a. Maximum luminous intensity: 1,200 candela or less B. Minimum luminous intensity of the measurement point ┌─────┬────┐ │Measurement Point │luminance(cd)│ ├──┬──┼────┤ │10U │5L │80 or higher │ │ ├──┼────┤ │ │V │80 or higher │ │ ├──┼────┤ │ │5R │80 or higher │ ├──┼──┼────┤ │5U │20L │40 or higher │ │ ├──┼────┤ │ │10L │80 or higher │ │ ├──┼────┤ │ │V │280 or more│ │ ├──┼────┤ │ │10R │80 or higher │ │ ├──┼────┤ │ │20R │40 or higher │ ├──┼──┼────┤ │H │20L │100 or more│ │ ├──┼────┤ │ │10L │280 or more│ │ ├──┼────┤ │ │5L │360 or more│ │ ├──┼────┤ │ │V │400 or more│ │ ├──┼────┤ │ │5R │360 or more│ │ ├──┼────┤ │ │10R │280 or more│ │ ├──┼────┤ │ │20R │100 or more│ ├──┼──┼────┤ │5D │20L │40 or higher │ │ ├──┼────┤ │ │10L │80 or higher │ │ ├──┼────┤ │ │V │280 or more│ │ ├──┼────┤ │ │10R │80 or higher │ │ ├──┼────┤ │ │20R │40 or higher │ └──┴──┴────┘ (Note) The luminous intensity standard for daytime running lights of mass-produced automobiles and mass-produced motorcycles is ±20 percent or less. May have deviation.