Annex 6 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙

288083 · 2026-07-10

■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 6-6] <Amended June 5, 2026> Installation and Luminous Intensity Standards for Front Fog Lights (Related to Article 38-2, Paragraph 1, Subparagraph 3) 1. Installation Standards for Front Fog Lights a. Installation Location 1) Width Direction The outer edge of the light-emitting surface shall be 400 millimeters or less from the outermost edge of the vehicle. 2) Height Direction a) installed in passenger cars, cargo vehicles with a gross vehicle weight of 3.5 tons or less, and special vehicles The illuminated surface of the front fog lights shall be between 250 millimeters and 800 millimeters above the ground in an unladen state. , and for other vehicles, install it at 1,200 millimeters or less b) The uppermost part of the front fog light's light-emitting surface is set lower than the uppermost part of the conversion beam headlight's light-emitting surface. thing to do B. Observation Angle The light-emitting surface of the front fog lights shall be within any range of 5 degrees upward, 5 degrees downward, 45 degrees outward, and 10 degrees inward. Will also be observed . Investigation direction The shining direction must be the front of the vehicle. 2) Vertical Position a) In the case of Class B front fog lights (referring to fog lights illuminated by a filament light source) The position of the cut-off line shall be -1.5% or less with one driver on board in an empty state. or) Class F3 front fog lights (filament, gas discharge, light-emitting diode light sources illuminated by refers to the case of ( (1) When the total luminous flux of the light source is 2,000 lumens or less, the position of the cutoff line is in the tolerance state With one driver in the vehicle, -1.0 percent or less (2) When the total luminous flux of the light source exceeds 2,000 lumens, the installation height is from the tolerance state Measure the lowest point of the light surface, and the vertical position of the cutoff line shall conform to the following criteria will be maintained automatically (A) If the installation height is 0.8 meters or less ① Limit: -1.0 percent ~ -3.0 percent ② Initial aiming value: -1.5 percent ~ -2.0 percent (b) If the installation height exceeds 0.8 meters ① Limit: -1.5 percent ~ -3.5 percent ② Initial aiming value: -2.0 percent ~ -2.5 percent d) Optical axis adjustment device (1) Front fog light that is independent or combined with other front lighting devices or lighting signal devices , it shall be suitable for 2)b)(2) (2) F3 front fog lights used as part of a convertible beam headlight or adaptive headlight , when ignited, it shall comply with Item 1, Subparagraph (c) of Annex 6-4. However, Annex 6-4, Item 1, Subparagraph ( can be applied to F3 front fog lights. (3) 2)b)(2) If suitable for, the vertical position can be automatically adjusted according to the surrounding environment . (4) If a failure occurs in the optical axis adjustment device, the position of the cutoff line is the position at the time of failure or The vertical position shall be less than or equal to the vertical position at the time of failure. . Operating conditions 1) The front fog lights shall be structured to be able to turn on and off independently Even if the front fog lights are used as part of the adaptive headlights, the front fog light function is DoGood E. Display Device Install an illuminating indicator device that shows the operating status of the front fog lights. bar. Other standards The front fog lights can automatically change their brightness according to ambient conditions. 2. Luminous Intensity Standards for Front Fog Lights A. Class B Luminous Intensity Standard-Ⅰ ┌─────────────────────────┬─────────────────┐ │MeasurementZone │Reference value (cd) │ ├─────────────────────────┼────────┬────────┤ │Zone A(225L∼225R and H∼75U) │95 or more 625 or less│- │ ├─────────────────────────┼────────┼────────┤ │Zone B (1,250L~1,250R and H~150U excluding Zone A) │625 or less │Exclude Zone A │ ├─────────────────────────┼────────┼────────┤ │Zone C (1,250L∼1,250R and upper part of 150U) │315 or less │- │ ├─────────────────────────┼────────┼────────┤ │Zone D(450L∼450R and 75D∼150D) │940 or more │At each vertical line │ ├─────────────────────────┼────────┤At least one side │ │Zone E (1,000L–1,000R and 75D–150D excluding Zone D)│315 or more │Vertex Anomaly │ └─────────────────────────┴────────┴────────┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "U" means the upper side of the HH line. 4. "D" means the lower side of the HH line. 5. "H" means HH line. 6. The luminous intensity standard for front fog lights of mass-produced vehicles may have a deviation of ±20 percent or less. <Location of measurement point on screen located 25 meters away> B. Class B Luminous Intensity Standard-Ⅱ ┌───────────┬──────┬──────┬────────────┐ │MeasurementPosition │Vertical Position(*)│Horizontal Position(*)│Reference value (cd) │ │ │ │ ├─────┬──────┤ │ │ │ │12V Series │13.2V Series │ ├────┬──────┼──────┼──────┼─────┼──────┤ │line 1(**)│All lines │15U∼60U │0 │100 or less │145 or less │ ├────┼──────┼──────┼──────┼─────┼──────┤ │zone A │All Zones │0∼1.75U │5L∼5R │62 or higher │85 or higher │ ├────┤ ├──────┼──────┼─────┼──────┤ │Zone B │ │0∼3.5U │26L∼26R │400 or less │570 or less │ ├────┤ ├──────┼──────┼─────┼──────┤ │zone C │ │3.5U∼15U │26L∼26R │250 or less │360 or less │ ├────┼──────┼──────┼──────┼─────┼──────┤ │Zone D │each vertical line │1.75D∼3.5D │12L∼12R │1,250 or more│More than 1,700 │ │ │At least one from START│ │ │8,000 or less│11,500 or less │ ├────┤is├──────┼──────┼─────┼──────┤ │zone E │on │1.75D∼3.5D │12L∼22L │ 600 or more│810 or higher │ │ │ │ │and │8,000 or less│11,500 or less │ │ │ │ │12R∼22R │ │ │ └────┴──────┴──────┴──────┴─────┴──────┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "U" means the upper side of the HH line. 4. "D" means the lower side of the HH line. 5. (*): Apply vertical axis angle coordinate system. 6. (**): In line 1 area, a single narrow zone or stripe is 160 candela (13.2V series must not exceed 230 candela, and narrow zones or stripes 2 degrees The cone angle or width must not exceed 1 degree, and a number of narrow spheres The reverse or stripe will drop by at least 10 degrees. 7. The luminous intensity standard for front fog lights of mass-produced vehicles may have a deviation of ±20 percent or less. <Location of measurement point on screen located 25 meters away> . Class F3 Luminous Intensity Standard-Ⅲ ┌────────────┬──────┬──────┬───────────────┐ │MeasurementPosition │VerticalPosition │HorizontalPosition(*) │Reference value (cd) │ │ │(*) │ ├───────┬───────┤ │ │ │ │12V Series │13.2V Series │ ├──────┬─────┼──────┼──────┼───────┼───────┤ │Point 1, 2(**) │AllMeasurementPoints │+60° │±45° │60 Below │85 or less │ ├──────┤ ├──────┼──────┤ │ │ │point 3, 4(**) │ │+40° │±30° │ │ │ ├──────┤ ├──────┼──────┤ │ │ │point 5, 6(**) │ │+30° │±60° │ │ │ ├──────┤ ├──────┼──────┤ │ │ │point 7, 10(**)│ │+20° │±40° │ │ │ ├──────┤ ├──────┼──────┤ │ │ │point 8, 9(**) │ │+20° │±15° │ │ │ ├──────┼─────┼──────┼──────┼───────┼───────┤ │Line 1(**) │All lines │+8° │-26°∼+2 │90 or less │130 or less │ ├──────┤ ├──────┤6° ├───────┼───────┤ │Line 2(**) │ │+4° │ │105 or less │150 or less │ ├──────┤ ├──────┤ ├───────┼───────┤ │Line 3 │ │+2° │ │170 or less │245 Below │ ├──────┤ ├──────┤ ├───────┼───────┤ │Line 4 │ │+1° │ │250 or less │360 or less │ ├──────┤ ├──────┼──────┼───────┼───────┤ │Line 5 │ │0° │-10°∼+1 │340 or less │485 or less │ │ │ │ │0° │ │ │ ├──────┤ ├──────┼──────┼───────┼───────┤ │Line 6(***) │ │-2.5° │-10˚~+10˚│More than 2,000 │More than 2,700 │ ├──────┤ ├──────┼──────┼───────┼───────┤ │Line 7(***) │ │-6.0° │-10˚~+10˚│Line 6 Measure Max │Line 6 Measure Max │ │ │ │ │ │value is │value is │ │ │ │ │ │HA │HA │ ├──────┼─────┼──────┼──────┼───────┼───────┤ │line 8L/R(***)│One this │-1.5°∼-3. │-22°, +22°│800 or more │1,100 or more │ │ │Measurement on │5° │ │ │ │ ├──────┤Point ├──────┼──────┼───────┼───────┤ │Line 9L/R(***)│ │-1.5°∼-4. │-35°, +35°│320 or more │450 or more │ │ │ │5° │ │ │ │ ├──────┼─────┼──────┼──────┼───────┼───────┤ │Zone D(***) │All Zones │-1.5°∼-3. │-10°∼+1 │8,400 or less │12,000 or less │ │ │ │5° │0° │ │ │ └──────┴─────┴──────┴──────┴───────┴───────┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "U" means the upper side of the HH line. 4. "D" means the lower side of the HH line. 5. (*): Apply vertical axis angle coordinate system. 6. (**): From measurement points 1 to 10 and in the area of ​​line 1 or lines 1 and 2, one narrow The zone or stripe must not exceed 160 candela (175 candela for the 13.2V series) , and narrow areas or stripes do not exceed a cone angle of 2 degrees or a width of 1 degree It must be, and multiple narrow zones or stripes must be separated by at least 10 degrees. 7. (***): Two front fog lights composed of a combined pair can each be tested and this circa First, for zones 6, 7, 8, and 9 and zone D, the average of the left and right front fog light measurements will be applied. is possible, and the horizontal positions of lines 6 and 7 shall be applied as 5° inward and 10° outward, respectively. However, The measured value of each front fog light must be at least 50 percent of the luminous intensity standard of line 6 in the table above. 8. The luminous intensity standard for front fog lights of mass-produced vehicles may have a deviation of ±20 percent or less. However, for the 13.2V series, the detailed measurement points below shall apply. a. At points 1, 2, 3, 4, 5, 6, 7, 10, 8, and 9, it must be 115cd or less. B. Line 1 must be 160cd or less. . Line 3 must be 295cd or less. . Line 4 must be 435cd or less. E. Line 5 must be 585cd or less. 9. When using a 12V series light-emitting diode module, multiply the measured luminous intensity value by 0.7 and the above table . <Location of measurement point on screen located 25 meters away>