Annex 5 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 5-31] <Amended Aug. 27, 2021>
Installation and Structural Standards for Emergency Escape Devices in Passenger Vehicles with a Seating Capacity of 16 or More (Related to Article 30)
1. Emergency Escape Device
a. Installation Quantity
The emergency escape device must have two or more elevator shafts installed, or at least one elevator shaft and one emergency door installed.
.
┌───────────┬──────────────┐
│Seating capacity of each car(persons)│ Minimum number of exits per car (pieces) │
├───────────┼──────────────┤
│16 or less │3 │
├───────────┼──────────────┤
│17 ∼ 30 │4 │
├───────────┼──────────────┤
│31 ∼ 45 │5 │
├───────────┼──────────────┤
│46 ∼ 60 │6 │
├───────────┼──────────────┤
│61 ∼ 75 │7 │
├───────────┼──────────────┤
│76 ∼ 90 │8 │
├───────────┼──────────────┤
│91 ∼ 110 │9 │
├───────────┼──────────────┤
│111 ∼ 130 │10 │
├───────────┼──────────────┤
│130 Exceed │11 │
└───────────┴──────────────┘
B. Installation Standards
1) In the case of double-decker large passenger vehicles (excluding the upper floor of the open-roof type), installed on the lower and upper floors respectively
must be done. However, restroom and pantry spaces are excluded from the installation space for emergency escape devices.
2) In the case of articulated buses, the front and rear passenger compartments are separated and applied (the front and rear connecting passageway is the passenger space
MTQ168d1342d04b96b500171Exclude from START).
3) The elevator door is included in the emergency escape device, and two elevator door measuring devices in accordance with Table 5, Item 30 simultaneously
If passed, it is considered as 2.
4) If the size of the emergency window is twice or more the size specified in Subparagraph 3(a), two shall be installed.
MTQ168d1342d04b96b500175 is considered to be STARTed.
5) Vehicles with a seating capacity of 23 people or less must meet the following criteria.
a) Install at least one on each side of the vehicle (left and right)
b) Install at least one each in the front and rear parts of the passenger space
6) Emergency escape devices (in the case of double-decker large passenger vehicles, the lower and upper floors are treated separately) must be installed
The number of units must be installed in equal numbers on the left and right sides, and if the minimum number of units is exceeded, then
Not.
7) At least one must be installed on the front or rear of the vehicle.
8) Passenger vehicles exceeding a seating capacity of 23 people where the number of standing passengers exceeds the number of seated passengers, and passenger vehicles with standing passengers
For passenger vehicles with 23 passengers or fewer, if installed on both the left and right sides in excess of the number of emergency escape devices
It is deemed to satisfy the criteria of 7).
9) In the case of double-decker large passenger vehicles, the criteria of 7) shall apply only to the upper floor.
10) Emergency doors other than elevator doors may be installed at the rear of the vehicle.
11) In the case of the driver's seat space, when the driver's seat is adjusted to the furthest rear position, as prescribed in 29 of Attached Table 5
the front edge of the passageway measuring device passes horizontally from the front of the driver's seat backrest
cannot pass through, and the panel notified by the Minister of Land, Infrastructure and Transport cannot pass through the front part of the driver's seat cushion
, the following criteria must be satisfied.
a) Two exits must be installed in the driver's seat. In this case, the exits are identical Install on the side
is not allowed, and one of the exits may be installed as an emergency window.
b) Where a seat is installed adjacent to the driver's seat, the exit shall be determined by the Minister of Land, Infrastructure and Transport
Must be equipped with the outlet specified in the notice.
12) In a passenger seat installed parallel to the driver's seat in the width direction of the vehicle, the [transaction] pursuant to Article 31
Where a START is installed, and entry into the cabin is possible from each seat, an exit () is located on the wall side.
.
13) A passenger vehicle with a seating capacity of 23 people or less that allows entry into the passenger compartment from the driver's seat
If an entrance/exit is installed in the driver's seat, it may be considered an emergency exit.
14) For an entrance/exit installed in the driver's seat, if a partition wall is installed between the passenger seat and the driver's seat,
Not considered an emergency door.
15) At locations where high-voltage systems, systems containing hazardous liquids or gases, etc. are installed, emergency
Cannot install escape hatch.
16) In the case of stairs connecting the lower and upper floors of a double-decker large passenger vehicle, one of the upper floor emergency escape devices
.
17) Passengers on the lower deck of a double-decker large passenger vehicle must be able to escape only to the lower deck in the event of an emergency
.
18) Double-decker large passenger vehicles must have stairs leading to the upper floor installed within 3m of the entrance/exit
. However, if the number of passengers on the upper floor is 30 or more, stairs designated by the Minister of Land, Infrastructure and Transport shall be added
must be installed horizontally.
19) A driver's seat of a passenger vehicle with a seating capacity of 23 people or less and installed parallel to the width direction of the vehicle
In cases where one or fewer passenger seats are installed, the aisle next to that seat According to 29 of Attached Table 5
, the entrance/exit installed in the aisle passenger seat is an entrance/exit in accordance with Attached Table 5-30
If the criteria are satisfied, it can be considered an emergency escape device.
20) If emergency doors and emergency exits are installed, in a conspicuous place nearby, emergency doors and emergency exits
and how to open the door must be indicated.
2. Emergency statement
The emergency door shall comply with any one of the following items.
A. Type A Emergency Door
1) The width shall be 600mm and the height 1,450mm or more. However, for passenger vehicles with a seating capacity of 23 people or less
, they shall be 550mm and 1,250mm or more, respectively
2) In the case of a passenger van with a seating capacity of 23 people or less where the emergency door is installed above the wheels, the [ ]
The width can be 300mm from the bottom up to a height of 400mm, and the upper corner of the emergency door
may be applied as 150mm or less
3) It must be openable from the inside and outside while stationary. However, if an external locking device is installed, the inside
It must be structured so that it can be opened from the START section.
4) If the emergency door operates electrically, return to the normal position after the control device is activated in an emergency
, the structure must ensure that the emergency door does not close again until the driver operates the closing mechanism
.
5) When the operating device of an electric emergency door is activated, measure the entrance/exit according to Annex 5-30 within 8 seconds
The structure must allow the device to pass through.
6) Sliding doors shall not be applied, and as a passenger vehicle with a seating capacity of 23 people or less, Article 102 Paragraph 2
, the ability to open emergency doors without tools after a frontal collision test
A sliding type can be applied to the top.
7) A device for opening an emergency door (in the case of a double-decker large passenger vehicle) from the outside of a vehicle
It is at a height of 1,000mm to 1,500mm from the ground, and within 500mm of the emergency door.
must.
8) A device for opening an emergency door inside a passenger vehicle with a seating capacity exceeding 23 people is located on the floor surface of the passenger compartment or
is a height from 1,000mm to 1,500mm from the top of the emergency door stairs, and from the emergency door
It must be within 500mm. However, in the case of control devices installed within the driver's seat, it must be within 500mm.
That is not the case.
9) In the case of a hinge structure fixed to the side of a vehicle, the hinge is installed at the front part in the longitudinal direction of the vehicle
must be structured to open to the outside of the vehicle, and inspection strap at an angle of 100 degrees or more,
A chain or other restraining device may be used.
10) If any emergency door is not completely closed, the driver must report the movement of the door latch or handle
A warning sound generator operated by must be installed.
11) If a night lock is installed, it must comply with the following standards.
a) Will be automatically deactivated when the ignition key is in the "ON" position
b) The night lock device, when the ignition key is in the "ON" position, on one or more doors Operating Status
. In this case, one signal shall have one or more doors
.
B. Type B Emergency Door
1) The emergency door is located on the rear left side of the passenger compartment (the emergency door is effective from the middle of the passenger compartment in the longitudinal direction of the vehicle
(refers to the case where the center of the width is at the rear) or must be installed at the rear of the passenger compartment.
2) The size of the emergency door must be an effective width of 400mm or more and an effective height of 1,200mm or more. However, the following
.
a) When installing an emergency door above the vehicle wheels, the effective width shall be up to 450mm from the cabin floor.
paper is 250mm or more, other parts 400mm or more, and for cases where the effective height is 1,200mm or more
b) Where seats are installed near the emergency exit The seat must be easily detachable or foldable, and the effective width
is 300mm or more up to 650mm from the cabin floor, and other parts 400mm or more, Effective
If the height is 1,300mm or more
d) Emergency doors of passenger vehicles for transporting children shall have an effective width of 300mm or more and an effective height of 1,000mm or more
, then
d) Emergency doors of a medium-sized passenger vehicle having three or more exits excluding emergency doors are effective when opened
In cases where a space of at least 1,200mm in width and at least 400mm in effective height is secured
3) The emergency door can be safely closed under normal conditions and does not require a separate device in an emergency
It must be openable from both the inside and outside of the passenger compartment. In this case, after the emergency door is opened, due to its own weight
Must be a non-closing structure.
4) Obstacles that could obstruct escape, such as bumpers and towing devices, must not protrude around the emergency door
and between the cabin floor and the lower part of the emergency door Going stairs must not be installed.
The location and operation method of emergency doors shall be indicated in an easily recognizable place or near the emergency doors.
must be used, and if lighting devices are used to indicate the location of emergency doors, green must be used.
6) An alarm device that notifies the driver when the emergency door is opened must be installed.
3. Emergency Window
a. The specifications of the emergency window shall be rectangular with dimensions of 500mm and 700mm or more, and when the area is 0.4㎡ or more
. However, in the case of the back side, the width may be 1,550mm and the height 350mm or more, and each corner
The radius of curvature shall be 250 mm or less
B. Installation Standards
1) In the case of hinged or detachable types, it must open outwards, and for detachable types, it must be completely separated from the vehicle body upon operation
must not be a structure that becomes.
2) Emergency windows shall meet any one of the following criteria.
a) To be operated inside or outside the vehicle
b) It must be safety glass (excluding laminated glass or plastic materials), and when safety glass is used, emergency window
Install equipment capable of breaking each emergency window near the door.
3) Emergency windows that can be locked from the outside of the vehicle must be openable from the inside of the vehicle.
4) In the case of a horizontal emergency window secured by a hinge at the top end, the window can be kept in a fully open state
It must be equipped with a device that allows passage from the inside and outside of the vehicle, and the hinged emergency window must be
structure.
5) The lower surface of the emergency window made of safety glass is the passenger compartment excluding the space where the engine and tires are installed
500mm or more and 1,200mm or less from the bottom surface (650mm or more and 1,200mm or less for hinge type)
. However, if a 650mm structure is installed on a hinged emergency window, the structure
If the external part satisfies the emergency window specifications, the bottom surface of the emergency window is for the engine and tires
It may be located at a depth of 500mm or more and 1,200mm or less on the cabin floor, excluding the installation space.
6) In cases where it is difficult to visually confirm whether a hinged emergency window is closed from the driver's seat due to its structure,
A warning sound device must be installed to inform the driver of the rim status.
4. Emergency Exit
a. Installation Quantity
A passenger vehicle with a seating capacity of 16 or more, where the number of seated passengers exceeds the number of standing passengers, and the seating capacity
Passenger vehicles with no standing passengers and carrying 23 or fewer passengers must be equipped with emergency exits as specified below.
However, in the case of the lower deck of a double-decker large passenger vehicle, the upper deck of an open-top double-decker large passenger vehicle, and an articulated bus
An emergency exit may not be installed in .
1) Seating capacity 30 people or less: 1 or more
2) Seating capacity exceeding 30: 2 or more
B. Installation Location and Size
1) If there is only one emergency exit, it must be installed in the center of the vehicle compartment divided into three equal parts.
2) If there are two emergency exits, the distance between the closest points of the emergency exits must be at least 2m
.
3) The area of the emergency exit shall be at least 0.45m2, and the size of the emergency exit shall be a 600mm × 700mm rectangle
.
. Installation Standard
1) Emergency exits must operate from the interior and exterior of the vehicle without obstructing passage.
2) Ceiling-mounted emergency exits must be manufactured as detachable, hinged types with safety glass.
3) Floor-type emergency exits must be connectable or detachable by hinges.
4) Warning sound device that notifies the driver if the floor-type emergency exit is not safely closed
You must install a floor-type emergency escape device that automatically locks when the speed exceeds 5 kilometers per hour.
Exit is excluded.
5) The detachable emergency exit does not completely detach from the vehicle body upon operation, and the detachable
Emergency exits must be separated only into the interior of the vehicle.
4) Hinged emergency exits must open at an angle of 100 degrees or more toward the front or rear of the vehicle.
However, hinged emergency exits installed on the floor must open only inward toward the vehicle cabin.
5) Emergency exits must be openable or removable from inside or outside the vehicle.
6) In the case of a destructible emergency exit, breaking equipment must be installed around the interior of the vehicle
한다