Annex 5 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 5-30] <Amended Oct. 26, 2022>
Standards for Entrances and Exits of Passenger Vehicles with a Seating Capacity of 16 or More (Related to Article 29, Paragraph 1, Subparagraph 1)
1. General Standards for Elevator Entrances
The elevator entrance must have elevator entrance measuring device 1 or measuring device 2 defined in the following table pass through it
.
┌───────────────────────────┬───────────┐
│Passenger Van Type │Top Panel Height │
│ │(A, unit: mm) │
│ ├─────┬─────┤
│ │Measuring device 1│Measuring device 2│
├───────────────────────────┼─────┼─────┤
│Passenger van with a seating capacity of 16 to 23 people │950week │950 │
├───────────────────────────┼─────┼─────┤
│Seating capacity 16 to 23 people, dedicated passenger van │700week │950 │
├───────────────────────────┼─────┼─────┤
│Exceeding the seating capacity of 23 people where the number of standing passengers exceeds the number of seats │1,100 │1,100 │
│is a passenger vehicle │ │ │
├───────────────────────────┼─────┼─────┤
│Exceeding a seating capacity of 23, where the number of seats is greater than the number of standing passengers │950 │1,100 │
│is a passenger vehicle │ │ │
├───────────────────────────┼─────┼─────┤
│Seated passenger vehicles exceeding a seating capacity of 23 people │850 │1,100 │
└───────────────────────────┴─────┴─────┘
Note) For passenger vehicles with a seating capacity of 16 to 23 people, the lower panel shall be in the same direction within the range of the upper panel
Can move horizontally.
2. Elevator Installation Standards
a. General Standard
1) At least one entrance/exit must be installed. However, for double-decker large passenger vehicles, two must be installed on the lower floor,
Articulated buses with more standing room than seated capacity are equipped with at least one entrance and exit at both the front and rear.
must.
2) In the case of an electric elevator door that cannot be opened by hand force after the operating device is activated in an emergency
Not considered an escape device.
3) The entrance/exit must be installed on the right side of the vehicle, and for passenger vans exceeding a seating capacity of 23 people
The vehicle, excluding elevators installed as follows, has one or more elevators in the vehicle length direction
It must be installed at the front of the START direction. However, technology capable of preventing malfunctions has been utilized.
And if approved by the Minister of Land, Infrastructure and Transport, an additional elevator door may be installed on the left side.
.
a) A ramp installed on the rear or side of a vehicle for wheelchair users to board and alight
b) A hatch installed on the rear or side of a vehicle for loading luggage
) Installed on the left side of the vehicle, which the driver can suppress operation through the device
hatch
4) In cases where two or more entrances are installed in a passenger vehicle with a passenger space of 10m2 or more, the entrance
The spacing between transverse vertical planes passing through the center of the sphere's area must satisfy the following criteria: 한
. However, this does not apply to articulated vehicles, etc., as determined and notified by the Minister of Land, Infrastructure and Transport.
.
a) It shall be at least 40% of the total length of the passenger space
b) In the case of double-decker large passenger vehicles, at least 25% of the total length of the vehicle for the lower floor or
Must be at least 40% of the total length of the passenger space
5) It must be openable from the inside and outside while stationary. However, if an external locking device is installed
, it must be designed to be openable from the inside.
6) A device for opening the entrance/exit from the outside of the vehicle is from 1,000mm from the ground
1, The height is up to 500mm, and it must be within 500mm of the elevator shaft.
7) A device for opening the entrance/exit from the interior of a passenger vehicle with a seating capacity exceeding 23 people is the cabin bar
height from 1,000mm to 1,500mm from the floor or the top of the stairs, and from the elevator shaft
It must be within 500mm. However, the circumference of the operating device installed in the driver's seat
Oh, that is not the case.
8) A manually operated elevator of a hinged or rotary structure, when the elevator is in an open state,
When operating in the room, if it comes into contact with an external object, move in the direction where the elevator door closes
must be a moving structure.
9) Manually operated elevators equipped with a door latch must have a double-locking structure.
10) A structure that does not endanger internal structures such as stairs and passengers when the elevator door closes inward
must be tightened.
11) A visibility device must be installed to enable the operator to check the surroundings inside and outside the elevator door.
and double-decker large passenger vehicles exceeding a seating capacity of 23 passengers where the number of standing passengers is greater than the number of seats
In the case of , it must also be installed inside the elevator shaft, on the stairs, and on the upper floors.
12) When installed on the rear of a passenger vehicle with a seating capacity of 23 people or less, the opening angle is 85 degrees
It must be structured to automatically lock in the fully opened position, up to 115 degrees.
However, for the purpose of boarding at a high platform, through a confirmed, secure boarding space at the rear of the vehicle
In cases such as allowing the entrance door to open up to 270 degrees to allow boarding, END
That is not the case.
13) The height of the first step of the elevator door shall be 40 centimeters or less.
b. When installing an external locking device on the elevator door, it must comply with any one of the following criteria
.
1) Must be deactivated when the ignition key is in the “ON” position.
2) If activated when the ignition key is in the “ON” position, warn the driver
must be used. In this case, it can be used simultaneously in two or more elevator shafts.
. Electric elevators operated by an operator must comply with the following standards.
1) In case of emergency, the elevator door shall be stationary or at a speed of 5 kilometers per hour or less according to the following standards
It must be possible to open appropriately from the inside and outside. However, in the case of the outside, the locking device
Excludes cases where it has been sanctified.
a) Open first when the elevator door operating device is operated
b) Internal operating devices are located within 300mm from the elevator shaft and 1,000mm or more above the first step platform.
It shall be located at a height. However, this shall not apply to cases for the disabled and the mobility impaired.
d) The start prevention device may be activated
d) The elevator door measuring device must be able to pass within 8 seconds upon operation of the control device
e) An easily removable protective device may be installed on the emergency operating device, and the operation of the operating device
Warn the driver visually and audibly when removing the door or protective cover
a) In the case of an elevator door that does not satisfy the criteria of Subparagraph 2, Item c, 5)c), to open the door, the operating device
Even if it returns to the normal position after operating the START value, the operator separately closes it.
MTQ168d1342d04b96b500087Will not close until START
) The doors shall not open at speeds exceeding 5 kilometers per hour
2) The prevention device for the externally installed emergency control device is
location. In this case, the emergency operating device deactivation function of the prevention device is
It shall not operate automatically without operator intervention, and upon engine start or every 20
The disable function must be released prior to the START kilometer.
3) If the entrance door is installed on a part other than the front of the vehicle body, when the entrance door is open
In the event that the visual warning indicator informing the operator of this occurs when the elevator door closes from the open position, the visual warning indicator []
must provide up to 30mm before the machine. In this case, if there are two or more elevator doors, one
Visual warning identification indicators can be provided for each elevator door using .
4) The elevator door opening and closing device is deflected by the operator even while the elevator door is opening or closing
.
5) When an electric elevator door closes, it shall be equipped with a protective function that meets the following standards.
a) 150N or less at the midpoint of the elevator shaft and at a point 150mm upward from the bottom end
(may temporarily exceed 150N but may not exceed 300N) applies
When is triggered, it must automatically enter a fully open state and maintain that state.
,
A measuring device can be used.
b) In the event that a finger or wrist is caught in the elevator door, according to any of the following criteria
Must conform.
(1) Keep open until operation is performed to close the open elevator door
(2) A truncated cone-shaped side with a height of 300mm, a top diameter of 5mm, and a bottom diameter of 30mm
The fitting device may come off.
(3) Side having a cross section with a height of 60mm, a width of 20mm, and a radius of curvature of 5mm at the corner
Position where the stopping device can pass (at a distance of 30mm or less from the fully closed position of the elevator door
(refers to the true position) will be maintained
d) If the front entrance meets any of the following criteria, entrance criteria
It is considered suitable for .
(1) Standards set forth in Subparagraph 2, Item 5)a)?b)
(2) When the end part is made of a soft material, measure with the measuring device specified in (Article 2, Subparagraph 5)a)
(Excluding cases where the rigid structure of the elevator door becomes completely closed when starting)
6) When an electric elevator door maintains a closed state by continuously receiving power supply
The driver must be visually warned when the power is cut off.
7) Device for preventing the vehicle from starting when the door is open (hereinafter referred to as door opening start prevention device
) is installed, it must operate at a speed of 5 kilometers per hour or less.
8) When a door opening prevention device is not installed, starting with the elevator door open
, the driver must be warned audibly.
. Automatic electric elevator (after being activated to operate automatically by the driver, passenger's
(referring to an automatically closing elevator door that can be opened by means of )
When installing, the following criteria must be met.
1) The activation of automatic operation of automatic electric elevators shall comply with the following criteria.
a) The activation and deactivation of the opening operation of all elevator doors, except in emergencies, is at the driver's seat
It will be possible at START.
b) An indicator showing that when the opening operation by the driver is activated, within the vehicle
It must be installed in the START section, and if the elevator door opens from the outside, it must also be installed on the exterior of the vehicle.
A START timer shall be installed. In this case, a display such as a light indicator, light push button, etc.
The START device must be installed at the relevant elevator shaft or in a location adjacent to the relevant elevator shaft.
) When operated directly by switch operation, the functional status of the automatic electric elevator is
The position of the START position, indicator lights or lighting switches, etc., must be indicated to the driver, and
Ensure that the START switch is not confused with other operating devices.
2) The opening of an automatic electric elevator door is activated by the operator, after which a passenger
The door must be able to be opened when performing the following operations.
a) In the case of the interior, operation of the push button or passage of the light detector
b) Operation of the light push button in the external case, operation of the push button located below the light indicator
or
3) The closing method of automatic electric elevator doors must comply with the following standards, and Subparagraph 2(d)4)
, the following
criteria.
a) When the automatically operated elevator door is opened, it must automatically close again after a certain period of time has elapsed
and install a safety device capable of delaying automatic closing
b) If a passenger attempts to board or alight while the door is closing, activate safety devices, etc.
The elevator door shall be of a structure that opens again by using START.
4) Smooth boarding and alighting for persons with disabilities, etc. pursuant to Article 2, Paragraph 1 of the "Act on Promotion of Mobility Convenience for Persons with Disabilities"
The elevator door used for operating the vehicle must be restricted from automatic closing according to the following criteria:
and a device that visually warns the driver when the function is operated according to the following (a)
A building indicator must be installed.
a) The operator must be able to limit automatic closing by operating a special operating device
and allow passengers to also restrict it by operating a push button
b) The limited automatic closing function shall be recoverable only by the operator