Annex 5 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙
288083 · 2026-07-10
■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 5-27] <Amended Dec. 31, 2019>
Standards for Standing Area Space and Handrail Installation
(Related to Article 23, Paragraph 1, Subparagraph 5; Article 28, Paragraphs 2 and 3; and Article 29, Paragraph 1, Subparagraph 3)
1. Standing area for one person
┌─────────────────────┬───────┐
│District minute │Standing area per person│
├─────────────────────┼───────┤
│Passenger van with a seating capacity of 23 people or less │0.125m2 or more │
├─────────────────────┼───────┤
│The number of standing passengers is greater than the number of seated passengers │0.125m2 or more │
│Passenger vehicles exceeding a seating capacity of 23 passengers │ │
├─────────────────────┼───────┤
│where the number of seated passengers is greater than the number of standing passengers │0.15m2 or more │
│Passenger vehicles exceeding a seating capacity of 23 passengers │ │
└─────────────────────┴───────┘
2. Space excluded from standing area
a. Driver's space
b. Stairs for elevators, stairs with a depth of less than 300 mm, and the area required for elevator operation (small
(Includes copper auxiliary device)
It is a space with a height of 1,350mm or less measured vertically from the cabin floor (passenger
For capacities of 23 or fewer, 1,200mm)
a. As a connecting part of an articulated vehicle, a space where passenger access is difficult
E. Luggage and Pantry Space
bar. Floor space of stairs installed inside the tea room
Company. The slope of the cabin floor surface is 8% in the longitudinal direction of the vehicle (the number of seats exceeds the number of standing passengers
12.5% in cases where the number of customers is large, 5% in the vehicle width direction Excess space
A. Seating areas (excluding folding seats) and other spaces difficult for standing passengers to access
. Vehicle length from the center of the driver's seat (based on the rearmost point if adjustable)
Front space of the START orientation
Vehicle. 300mm of space in front of all seats (excluding folding seats, and of side-facing seats )
(225mm)
K. Spaces where 400mm and 300mm rectangles cannot be placed
Ta. Upper deck space of a double-decker large passenger vehicle
F. Wheelchair User Space (including space provided separately exclusively for wheelchair users)
3. Handle base and handle
a. The handle base has a length of 100mm or more, and the cross-sectional size is 20mm or more and 45mm or less.
It shall be. However, this shall not apply to handrails installed at the entrance and exit and seats.
.
or. the gap between the inner side of the vehicle or the wall is at least
It must be at least 40mm. However, if it is exclusively for passenger seating or if the number of seated passengers is greater than the number of standing passengers...
In cases where it is installed in the entrances and seats of many vehicles, it must be at least 35mm.
. At each point of the standing area, the measurement of the measuring device separately notified by the Minister of Land, Infrastructure and Transport
The number of handles within the specified range must be at least two, and if a handle strap is installed
can be seen as a handle when properly fixed. However, the minimum
If the cross-section is 15mm, the minimum cross-section of the other handle must be 25mm or more.
must be.
. The handle bar or handle extends from 800mm to 1,950mm from the floor of the tea room
Install at the START height
E. When measuring according to Item C, the minimum of the two handles used at the standing passenger's position
One unit shall be 1,500mm or less from the floor of the passenger cabin. However, the entrance and exit and ancillary equipment
The value shall not be so, and in this case, it must be 20% or less of the total standing area.
bar. The handrail is located in the standing area and where seats are installed on the side or rear inner wall of the car
In spaces where it is not installed, a bar extending from 800mm to 1,500mm from the cabin floor surface
To be installed parallel to the surface
J. Requirements for handrails or handles installed in elevator shafts
1) Handrails or handrails shall be installed on both sides of the elevator entrance. Elevator side
In the case of an elevator shaft where two locking devices can pass simultaneously, the middle part of the entrance
Install one support or handle at START.
Handrails or handrails installed in elevator shafts may be used outdoors and on stairs.
Installed near the elevator entrance and from 800mm from the ground and the top of each step
Install at a height of up to 1,100mm
3) The position of the handle used externally is from the outer end of the first step platform inward
Below 400mm
4) The position of the handrail used on each step is from the outer end of each step inward
Below 600mm
Vehicle. Handrails installed on the stairs connecting the lower and upper floors of a double-decker large passenger vehicle, and
is the requirement for the handle
1) On each side of the space where the stairs are installed, from 800mm from the top of each step
1 Install a handle bar or handle at a height of up to 1,100mm
2) Handrails for standing passengers near the stairs connecting the lower and upper floors
Stand or handle at a height of 800mm to 1,100mm from the floor surface of each level
Install in START
3) The position of the handle used on the lower floor is from the outer end of the first step platform inward
Below 400mm
4) The position of the handrail used on each step is from the outer end of each step inward
Below 600mm