Annex 5 — 자동차 및 자동차부품의 성능과 기준에 관한 규칙

288083 · 2026-07-10

■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 5-18] <Amended June 5, 2026> Installation and Luminous Intensity Standards for Convertible Beam Headlights on Motorcycles (Related to Article 75) 1. Installation Standards a. Two-wheeled vehicles with an engine displacement of 50cc or less and a maximum speed of 50 kilometers per hour or less 1) Install 1 or 2 units 2) The light color shall be white 3) Installation Location a) Width Direction (1) One independent convertible beam headlight is located on the upper, lower, left, and right sides of the other front light, respectively It can be installed, and if installed in a vertical direction, the reference point of the conversion beam headlight is this The wheel must be located within the central vertical longitudinal section of the vehicle and, when installed in the horizontal direction The reference points of the lights shall each be symmetrical to the central vertical longitudinal plane of the two-wheeled vehicle. (2) One convertible beam headlight coupled with other front lights is the center number of the two-wheeled vehicle It shall be located within the longitudinal section. However, if the conversion beam headlight is an independent driving beam headlight or is the lights' The reference points shall each be symmetrical to the central vertical longitudinal plane of the two-wheeled vehicle. (3) When installing two convertible beam headlights, the reference point of the lights is the center of the two-wheeled vehicle Must be symmetrical to the vertical longitudinal plane b) Height Direction Must be between 500mm and 1,200mm above the ground ) Length direction The convertible beam headlights must be located at the front of the vehicle, and when illuminated, the reflection on the vehicle surface It shall be a structure that does not directly or indirectly interfere with driving by means of the START part or rearview mirror. ra) The distance between the light-emitting surfaces of the two convertible beam headlights shall be 200 millimeters or less (three-wheeled type and (Excluding wheel types) 4) Observation Angle a) The light-emitting surface of the conversion beam headlight is observable in any range of 15 degrees upward or 10 degrees downward. to be b) In the case of a single light, the light-emitting surface of the conversion beam headlight shall be at an angle of 45 degrees or less to the left and right It shall be observed within the range of 45 degrees outward and 10 degrees inward. However, if installed in pairs, it shall be observed within the range of 45 degrees outward and 10 degrees inward. Must be observed in any range below. 5) Investigation Direction The shining direction shall be the front of the vehicle. However, changes in the direction of illumination depending on steering may be permitted. . The convertible beam headlight can be installed independently without being combined with other lights. 7) Operating Conditions a) It shall illuminate simultaneously with the ignition. However, this shall not apply if daytime running lights are installed. not. b) The driving beam will be turned off simultaneously with the switch to the conversion beam 8) Display device When installing an indicator device that shows the operating status of the conversion beam headlight, a non-flashing green indicator Install the device or. Two-wheeled vehicles with an engine displacement exceeding 50 cc or a top speed exceeding 50 kilometers per hour Car 1) Install 1 or 2 units 2) The light color shall be white 3) Installation Location a) Width Direction (1) One independent convertible beam headlight is located on the upper, lower, left, and right sides of the other front light, respectively It can be installed, and when installed in a vertical direction, the reference point of the surrounding beam headlight is It must be located within the central vertical longitudinal section of the two-wheeled vehicle and installed in the horizontal direction In the case of START, the reference points of the lights shall each be symmetrical to the central vertical longitudinal plane of the two-wheeled vehicle. (2) One peripheral beam headlight coupled with other front lights is the center of the two-wheeled vehicle Located within the vertical longitudinal section. However, the surrounding circular beam headlights are independent driving beam headlights or lights when installed horizontally with peripheral beam headlights combined with side marker lights shall each be symmetrical to the central vertical longitudinal plane of the two-wheeled vehicle (3) When installing two convertible beam headlights, the reference point of the lights is the center of the two-wheeled vehicle Must be symmetrical to the vertical longitudinal plane (4) When installing additional lighting units for curved road lighting, the following criteria Will be suitable (a) In the case of an additional lighting unit composed of left and right pairs of lights, among two-wheeled vehicles Must be symmetrical to the vertical longitudinal plane (b) In the case of an additional lighting unit consisting of a single light, the vertical center of the two-wheeled vehicle To install on board b) Height Direction Must be between 500mm and 1,200mm above the ground ) Length direction The convertible beam headlights must be located at the front of the vehicle, and when illuminated, the reflection on the vehicle surface It shall be a structure that does not directly or indirectly interfere with driving by means of the START part or rearview mirror. ra) The distance between the light-emitting surfaces of the two convertible beam headlights shall be 200 millimeters or less (three-wheeled type and (Excluding wheel types) 4) Observation Angle a) The light-emitting surface of the conversion beam headlight can be observed in any range of 15 degrees upward or 10 degrees downward. thing b) In the case of a single light, it shall be observable to the left and right within any range of 45 degrees or less. c , in the case of installation in pairs, within any range of 45 degrees outward and 10 degrees inward or less, pipe must be measured. d) Devices or parts installed around the headlights that may cause harm to other road users It will be a structure that causes no harm 5) Investigation Direction a) The illuminating direction shall be the front of the vehicle. However, changing the direction of illumination according to steering may be permitted can. b) The vertical inclination of the headlights forming the surrounding circular beam is between -0.5 percent and -2.5 percent It shall be as above. However, this shall not apply if an external control device is installed. ) If the total target luminous flux of the headlights creating the surrounding circular beam exceeds 2,000 lumens Vertical The slope must be in the range of -0.5 percent to -2.5 percent and the headlight beam axis adjuster will be a structure that operates automatically 6) Operating Conditions a) It shall illuminate simultaneously with the ignition. However, this shall not apply if daytime running lights are installed. not. b) The driving beam shall be structured to be simultaneously turned off when switched to the conversion beam. ) If the conversion beam is a gas discharge headlight, when switching from the conversion beam to the driving beam, conversion beam should remain lit d) Use an additional light source or lighting unit only when the surrounding circular beam is operating By doing so, it will be possible to implement lighting for curved roads. e) Using an additional light source or lighting unit, curves on each side of the two-wheeled vehicle , when the tilt angle exceeds the minimum angle specified by the creator, Auto It must be a structure that lights up with START. bar) If the tilt angle is 5 degrees or less, additional light sources or lighting units are not lit It will be a structure that does not Additional light sources or lighting units must have a tilt angle that exceeds the minimum specified by the manufacturer. It must be a structure that turns off when the angle is smaller than the resonance angle. 7) Display device a) In the case of installing an indicator device that shows the operating status of the conversion beam headlight, non-flashing green Install a color display device b) The flashing amber indicator that signals a malfunction of the headlight horizontal tilt control device It must be installed, and combined with the display device pursuant to Item 1, Subparagraph 7)b) of Annex 5-17, it must be installed It can be used. In this case, if a failure of the headlight horizontal tilt adjustment device is detected, display The START device must operate continuously. d) In the event of a malfunction in the control system of the headlight horizontal tilt adjuster, curve road adjustment name will be automatically turned off 8) Other standards a) In the event of a malfunction in the headlight horizontal tilt adjuster, without special tools horizontal Re-aiming into the same horizontal and vertical aiming state as a headlight without a tilt adjustment device It will be possible to determine b) The manufacturer shall provide instructions necessary for readjusting the headlight horizontal tilt adjuster must. However, this does not apply if equipped with an automatically readjusting system . 2. Luminous Intensity Standard a. General luminous intensity standard ┌───────────────┬──────────────────────┐ │Measurement points and zones │Reference value (cd) │ │ ├──────────┬───────────┤ │ │Class A │Class B │ │ ├────┬─────┼─────┬─────┤ │ │12V Series│13.2V Series│12 V Series │13.2V Series│ ├──────┬────┬───┼────┼─────┼─────┼─────┤ │Zone Ⅰ │0~15U │5L~5R│200 or less│320 or less │438 or less │700 or less │ ├──────┼────┼───┼────┼─────┼─────┼─────┤ │line 50L~50R │0.86D │2.5L~│- │- │938 or higher │1,100 or more│ │(except 50V) │ │2.5R │ │ │ │ │ ├──────┼────┼───┼────┼─────┼─────┼─────┤ │50V │0.86D │0 │- │- │1,875 or more│2,200 or more│ ├──────┼────┼───┼────┼─────┼─────┼─────┤ │line 25L~25R │1.72D │5L~5R│800 or more│1,100 or more│1,875 or more│2,200 or more│ ├──────┼────┼───┼────┼─────┼─────┼─────┤ │line 12.5L~ │3.43D │5L~5R│400 or more│550 or more │- │- │ │12.5R │ │ │ │ │ │ │ ├──────┼────┼───┼────┼─────┼─────┼─────┤ │Zone Ⅳ │0.86D~ │5L~5R│- │- │938 or higher │1,100 or more│ │ │1.72D │ │ │ │ │ │ └──────┴────┴───┴────┴─────┴─────┴─────┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "H" means HH line. 4. "V" means VV line. 5. The 50R/50L of Class B 12V series convertible beam headlights must be at least 0.25 times. 6. A 0.25-degree error at each measurement point of the 13.2V series conversion beam headlight shall be allowed. 7. The luminous intensity of conversion beam headlights for mass-produced motorcycles shall have a deviation of ±20 percent or less of the above standard can have. 8. Delete <2026. 6. 5.> 〈Measurement point location on screen at a distance of 25 meters (Class A)〉 〈Measurement point location on screen at a distance of 25 meters (Class B)〉 B. 12V Series Luminous Intensity Standard ┌─────┬───────────┬─────────────────────────────┐ │measurement point and │Angle5) │Reference value (cd) │ │Section │ ├──────────┬──────────┬───────┤ │ │ │Class C │Class D │Class E │ │ │ │(125cc or less) │(over 125cc) │ │ │ ├────┬──────┼───┬──────┼───┬──────┼───┬───┤ │ │Vertical │Horizontal │Minimum│MAX │Minimum│MAX │Minimum│MAX│ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │1 │0.86D │3.5R │1,438 │9,625 │1,438 │9,625 │2,500 │12,500│ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │2 │0.86D │0 │1813 │- │3,625 │- │5,000 │- │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │3 │0.86D │3.5L │1,433 │9,625 │1,433 │9,625 │2,500 │12,500│ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │4 │0.50U │1.50L, 1.50R│- │675 │- │675 │- │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │6 │2.00D │15L, 15R │400 │- │800 │- │1,250 │- │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │7 │4.00D │20L, 20R │119 │- │238 │- │625 │- │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │8 │0 │0 │- │1,200 │- │1,200 │- │1,200 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │line 11 │2.00D │9L~9R │1,000 │- │1,000 │- │1,875 │- │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │line 12 │7.00U │10L~10R │- │188(cone angle 2│- │188(conical angle │- │675 │ │ │ │ │ │degree or less│ │2 degrees or less │ │ │ │ │ │ │ │right 600) │ │case 600) │ │ │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │line 13 │10.00U │10L~10R │- │94(cone angle 2 │- │94(cone angle 2 │- │675 │ │ │ │ │ │degree or less│ │degree or less│ │ │ │ │ │ │ │right 400) │ │right 400) │ │ │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │line 14 │10U~ │0 │- │94(cone angle 2 │- │94(cone angle 2 │- │675 │ │ │90U │ │ │degree or less│ │degree or less│ │ │ │ │ │ │ │right 400) │ │right 400) │ │ │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │15 │4.00U │8.0L │63 │675 │63 │675 │63 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │16 │4.00U │0 │63 │675 │63 │675 │63 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │17 │4.00U │8.0R │63 │675 │63 │675 │63 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │18 │2.00U │4.0L │125 │675 │125 │675 │125 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │19 │2.00U │0 │125 │675 │125 │675 │125 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │20 │2.00U │4.0R │125 │675 │125 │675 │125 │675 │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │21 │0 │8.0L, 8.0R │63 │- │63 │- │63 │- │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │22 │0 │4.0L, 4.0R │125 │675 │125 │675 │125 │675 │ ├─────┼────┴──────┼───┼──────┼───┼──────┼───┼───┤ │Zone 1 │1U/8L-4U/8L-4U/8R-1U/ │- │675 │- │675 │- │675 │ │ │8R-0/4R-0/1R-0.6U/0-0/│ │ │ │ │ │ │ │ │1L-0/4L-1U/8L │ │ │ │ │ │ │ ├─────┼────┬──────┼───┼──────┼───┼──────┼───┼───┤ │Zone 2 │4U~10U │10L~10R │- │188(cone angle 2│- │188(conical angle │- │675 │ │ │ │ │ │degree or less│ │2 degrees or less │ │ │ │ │ │ │ │right 600) │ │case 600) │ │ │ ├─────┼────┼──────┼───┼──────┼───┼──────┼───┼───┤ │Zone 3 │10U~90U│10L~10R │- │94(cone angle 2 │- │94(cone angle 2 │- │675 │ │ │ │ │ │degree or less│ │degree or less│ │ │ │ │ │ │ │right 400) │ │right 400) │ │ │ └─────┴────┴──────┴───┴──────┴───┴──────┴───┴───┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "H" means HH line. 4. "V" means VV line. 5. Each measurement point shall allow an error of 0.25 degrees. 6. If the conversion beam is combined with the side marker lights, measurement points 15–22 simultaneously illuminate the side marker lights must be measured. 7. Measurement must be taken by aiming at 0.57D vertically and 0 horizontally, but vertical 0.3D∼0.8D, horizontal ±0.5L, can be reaimed with R. 8. The luminous intensity of conversion beam headlights for mass-produced motorcycles shall have a deviation of ±20 percent or less of the above standard can have. 9. Delete <2026. 6. 5.> 〈Measurement point location on screen at a distance of 25 meters (Class C, D, E)〉 . 13.2V series luminous intensity standard ┌────┬─────────────────┬───────────────────┐ │measuring point │Angle5) │Reference value (cd) │ │and │ ├──────────────┬────┤ │STATION │ │Minimum │max │ │ ├────┬────────────┼────┬────┬────┼────┤ │ │Vertical │Horizontal │Class C│Class D│Class E│Class │ │ │ │ │ │ │ │C, D, E │ ├────┼────┼────────────┼────┼────┼────┼────┤ │1 │0.86D │3.5R │2,000 │2,000 │2,500 │13,750 │ ├────┼────┼────────────┼────┼────┼────┼────┤ │2 │0.86D │0 │2,450 │4,900 │4,900 │- │ ├────┼────┼────────────┼────┼────┼────┼────┤ │3 │0.86D │3.5L │2,000 │2,000 │2,500 │13,750 │ ├────┼────┼────────────┼────┼────┼────┼────┤ │4 │0.50U │1.50L, 1.50R │- │- │- │900 │ ├────┼────┼────────────┼────┼────┼────┼────┤ │5 │2.00D │15L, 15R │550 │1,100 │1,100 │- │ ├────┼────┼────────────┼────┼────┼────┼────┤ │6 │4.00D │20L, 20R │150 │300 │600 │- │ ├────┼────┼────────────┼────┼────┼────┼────┤ │7 │0 │0 │- │- │- │1,700 │ ├────┼────┼────────────┼────┼────┼────┼────┤ │line 1 │2.00D │9L~9R │1,350 │1,350 │1,900 │- │ ├────┼────┼────────────┼────┴────┴────┼────┤ │8 │4.00D │8.0L │8 + 9 + 10 ≥ 150 │700 │ ├────┼────┼────────────┤ ├────┤ │9 │4.00D │0 │ │700 │ ├────┼────┼────────────┤ ├────┤ │10 │4.00D │8.0R │ │700 │ ├────┼────┼────────────┼──────────────┼────┤ │11 │2.00D │4.0L │11 + 12 + 13 ≥ 300 │900 │ ├────┼────┼────────────┤ ├────┤ │12 │2.00D │0 │ │900 │ ├────┼────┼────────────┤ ├────┤ │13 │2.00D │4.0R │ │900 │ ├────┼────┼────────────┼────┬────┬────┼────┤ │14 │0 │8.0L, 8.0R │50 │50 │50 │- │ ├────┼────┼────────────┼────┼────┼────┼────┤ │15 │0 │4.0L, 4.0R │100 │100 │100 │900 │ ├────┼────┴────────────┼────┼────┼────┼────┤ │zone │1°U/8°L-4°U/8°L-4°U/8°R-1° │- │- │- │900 │ │1 │U/8°R-0/4°R-0/1°R-0.6°U/0- │ │ │ │ │ │ │0/1°L-0/4°L-1°U/8°L │ │ │ │ │ ├────┼────┬────────────┼────┼────┼────┼────┤ │zone │4U~15U │8L~8R │- │- │- │700 │ │2 │ │ │ │ │ │ │ └────┴────┴────────────┴────┴────┴────┴────┘ (Note) 1. "L" means the left side of the VV line. 2. "R" means the right side of the VV line. 3. "H" means HH line. 4. "V" means VV line. 5. Each measurement point shall allow an error of 0.25 degrees. 6. If the conversion beam is combined with the side marker lights, measurement points 15–22 simultaneously illuminate the side marker lights must be measured. 7. Measurements must be taken by aiming at 0.57D vertically and 0 horizontally, but vertical 0.3D–0.8D, horizontal ±0.5L, can be reaimed to R. 8. The luminous intensity of conversion beam headlights for mass-produced motorcycles shall have a deviation of ±20 percent or less of the above standard can have. 9. Delete <2026. 6. 5.> 〈Measurement point location on screen at a distance of 25 meters (Class C, D, E)〉 d. Notwithstanding the provisions of subparagraphs (a) and (b), convertible beam headlights are subject to subparagraphs 2 and 3 of Annex 6-4 Or the luminous intensity standard according to subparagraph 4 may be applied.