■ Rules on Performance and Standards of Automobiles and Automotive Parts [Appendix 5] <Amended Aug. 14, 2025> Standards for Insulation Safety, etc. of High Power Electrical Equipment (Related to Article 18-2 and Article 18-6, Paragraph 1, Subparagraph 3) 1. The live conductor part of a high-voltage electrical device shall comply with the standards of each of the following items. a. The protective mechanism of the live conductor part cannot be opened, disassembled, or removed without using a tool . b. Live conductors in passenger quarters or baggage areas shall not be in direct contact during IPXXD access must. . Live conductor parts, excluding item (b), must not be directly contacted during IPXXB access. d. In the case of two-wheeled vehicles without a passenger compartment, notwithstanding subparagraph c, live conductor part must not be directly contacted when accessing IPXXD. 2. Connectors of high-voltage electrical devices (including electric vehicle charging connectors) are each item of subparagraph 1 . However, if it falls under any of the following cases The connector shall not be subject to the standards of Subparagraph 1(a). a. In the case where subparagraph 1b or c is suitable with the connector disconnected b. In the case where the connector is located on the exterior floor surface of the vehicle body and has a locking mechanism . The connector has a locking mechanism, and to disconnect the connector, a separate protective mechanism If it is a structure that can be removed with a tool . Within 1 second after disconnecting the connector, the voltage is DC 60 volts or AC (refer to the RMS value . The same applies below in this table) If it drops below 30 volts 3. High-voltage circuit breaker for inspection and repair of high-voltage electrical equipment can be opened without tools. In the case of a structure that can be disassembled or removed, direct contact must not be made during IPXXB access . 4. External or protective devices of high-voltage electrical equipment shall have warnings in accordance with the standards of each of the following items marking must be made. However, if located on the high-voltage connector and the exterior floor surface of the vehicle body or easily This shall not apply if there is a protective device to prevent access, opening, or removal. a. The warning indications are as follows. Color: Background is yellow, images and outlines are black a. Warning signs must be identifiable and must not easily fade or be erased. . . In the case of the drive battery, a warning sign must be attached to the top or surrounding area. 5. The electrical wiring between high-voltage electrical devices (excluding cases located inside protective devices) The uniform must be orange. 6. Exposed electrically conductive parts of high-voltage electrical equipment protection mechanisms are connected to the electrical chassis and wiring, welding or must be electrically connected by means such as bolts, and exposed electrical conductive parts and electrical chassis The resistance between START and END must be less than 0.1Ω. 7. The insulation resistance between the live conductor and the electrical chassis of a high-voltage electrical device shall be in accordance with each of the following items standard. a. When the DC circuit and the AC circuit are configured independently, the insulation resistance is 100Ω each. /V(DC), must be 500Ω/V(AC) or higher. b. When DC and AC circuits are electrically combined, the insulation resistance is 500Ω /V. However, if the AC circuit satisfies any of the following, It can be made greater than 100Ω/V. 1) The protective mechanism of a high-voltage electrical device is insulated with double or more insulators inside, and If subparagraph 6 is satisfied 2) The drive motor housing, power converter outer casing, connectors, etc. are mechanically robust 하게 장착된 구조일 경우 . When the insulation resistance of the high-voltage DC circuit of a fuel cell vehicle drops below 100Ω/V An insulation resistance monitoring system must be equipped to provide a warning to the operator. . The insulation resistance between the live conductor part of the electric vehicle charging connector and the electrical chassis is the must be 1MΩ or greater. E. A vehicle in which the live conductor part of a high-voltage electrical device is connected to an electrical chassis, the live conductor part and the electrical chassis is 30 volts AC or 60 volts DC or less The insulation resistance standard does not apply to . 8. To charge the drive battery of an electric vehicle, an external power source (charging voltage and current) Before entering, the grounding of the vehicle and external charging device must be connected first, and the external charging device must be maintained until the source is disconnected, and while the drive battery is charging, the vehicle Must not be driven. (Note) 1. IPXXB: International Protection Code (IEC 60529) Finger model for verifying prescribed finger access safety 2. IPXXD: International Protection Code (IEC 60529) Wire model for verifying specified wire access safety 3. Electrical Chassis: Refers to the electrically conductive parts of a vehicle body through which electricity flows.