Annex 4 — 석유광산안전규칙
278739 · 2025-10-01
■ Petroleum Mine Safety Regulations [Appendix 4] <Amended Jan. 21, 2022>
Pressure test of blowout prevention device of offshore drilling vessel (related to Article 58, Paragraph 2)
1. Initial Testing (Before Drilling and Installation of Explosion-Proof Devices)
┏━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━┓
┃Pressure Test Requirements │Test Pressure ┃
┃ ├──────┬─────────────┨
┃ │Low Pressure │High Pressure ┃
┠────────────────┼──────┼─────────────┨
┃a. Diverter │(if necessary) │if necessary ┃
┠────────────────┼──────┼─────────────┨
┃B. Enullar Preventer │200-300psi │Minimum 70% of operating pressure ┃
┠────────────────┼──────┼─────────────┨
┃. RAM Preventer │ │ ┃
┃ 1) Fixed RAM │200-300psi │Operating pressure of ram ┃
┃ 2) Variable RAM │200-300psi │Operating pressure of ram ┃
┃ 3) Cutting Ram │200-300psi │Operating pressure of ram ┃
┠────────────────┼──────┼─────────────┨
┃. Explosion-proof device? Head device connecting device │200-300psi │Operating pressure of ram ┃
┠────────────────┼──────┼─────────────┨
┃Ma. Choke, Kill Line? Valve │200-300psi │Operating pressure of ram ┃
┠────────────────┼──────┼─────────────┨
┃Bar. Choke Manifold │ │ ┃
┃ 1) Upstream │200-300psi │Operating pressure of ram ┃
┃ 2) Downstream │200-300psi │(if necessary) ┃
┠────────────────┼──────┼─────────────┨
┃Company. Explosion-proof control device │ │ ┃
┃ 1) Manifold? Explosion-proof line │- │Minimum 3000psi ┃
┃ 2) Accumulator │Pre-charge Confirm│- ┃
┃ 3) Closing time │Performance Test │- ┃
┃ 4) Pump capacity │Performance Test │- ┃
┠────────────────┼──────┼─────────────┨
┃Ah. Safety Valve │ │ ┃
┃ -Kelly, Kelly Valve, Safety Valve │200-300psi │Operating pressure of components ┃
┠────────────────┼──────┼─────────────┨
┃. Other Equipment │ │ ┃
┃ 1) Riser Slip │Flow test │- ┃
┃ 2) Muddy water? Gas separator │Flow test │- ┃
┃ 3) Trip Tank │Flow test │- ┃
┗━━━━━━━━━━━━━━━━┷━━━━━━┷━━━━━━━━━━━━━┛
<Test Method>
a) Low or high pressure tests must be stabilized without pressure change for at least 5 minutes.
b) Equipment for pressure control shall conduct tests at a pressure higher than the required subsurface pressure
must be performed.
) Pressure is applied by converting 0.070307 kg/㎠ to 1 psi.
2. Testing during the work period
┏━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━┓
┃Pressure Test Requirements │Test Pressure ┃
┃ ├─────┬───────────────┨
┃ │Low Pressure │High Pressure ┃
┠──────────────┼─────┼───────────────┨
┃a. Diverter │(if necessary) │if necessary ┃
┠──────────────┼─────┼───────────────┨
┃B. Enullar Preventer │200-300psi│Minimum 70% of operating pressure ┃
┠──────────────┼─────┼───────────────┨
┃. RAM Preventer │ │ ┃
┃ 1) Fixed RAM │200-300psi│Maximum ground closure pressure or higher ┃
┃ 2) Variable RAM │200-300psi│Maximum ground closure pressure or higher ┃
┃ 3) Cutting Ram │200-300psi│Maximum ground closure pressure or higher ┃
┠──────────────┼─────┼───────────────┨
┃. Choke line? Valve │200-300psi│Maximum ground closure pressure or higher ┃
┠──────────────┼─────┼───────────────┨
┃Ma. Kill Line? Valve │200-300psi│Maximum ground closure pressure or higher ┃
┠──────────────┼─────┼───────────────┨
┃Bar. Choke Manifold │ │ ┃
┃ 1) Upstream │200-300psi│Maximum ground closure pressure or higher ┃
┃ 2) Downstream │(if necessary) │(if necessary) ┃
┠──────────────┼─────┼───────────────┨
┃Company. Explosion-proof control device │ │ ┃
┃ 1) Manifold? Explosion-proof line │- │if necessary ┃
┃ 2) Accumulator │- │- ┃
┃ 3) Closing time │Performance Test │- ┃
┃ 4) Pump capacity │Performance Test │- ┃
┠──────────────┼─────┼───────────────┨
┃Ah. Safety Valve │ │ ┃
┃ -Kelly, Kelly Valve, Safety Valve │200-300psi│Maximum ground closure pressure or higher ┃
┠──────────────┼─────┼───────────────┨
┃. Other Equipment │ │ ┃
┃ 1) Riser Slip │Flow test │- ┃
┃ 2) Muddy water? Gas separator │(if necessary) │- ┃
┃ 3) Trip Tank │Flow test │- ┃
┗━━━━━━━━━━━━━━┷━━━━━┷━━━━━━━━━━━━━━━┛
<Test Method>
a) Low or high pressure tests must be stabilized without pressure change for at least 5 minutes.
b) The work period shall not exceed 21 days.
) Pressure is applied by converting 0.070307 kg/㎠ to 1 psi.