Annex 1 — 건축물의 피난ㆍ방화구조 등의 기준에 관한 규칙
279461 · 2025-10-31
■ Rules on Standards for Evacuation, Fire Protection, and Structures of Buildings [Appendix 1-3] <Amended Jan. 6, 2012>
Illumination Standards According to Use of Living Rooms (Related to Article 17, Paragraph 1)
┏━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━┓
┃Illumination Classification │At a height of 85 centimeters from the floor ┃
┃Classification of Living Room Usage │Illuminance (lux) of a horizontal surface with START ┃
┠────┬──────────────┼──────────────────┨
┃1. Residence │ Reading? Eating? Cooking │150 ┃
┃ │ Other │70 ┃
┠────┼──────────────┼──────────────────┨
┃2. Office │ Design? Drafting? Calculation │700 ┃
┃ │ General Office │300 ┃
┃ │ Other │150 ┃
┠────┼──────────────┼──────────────────┨
┃3. Task │ Examination? Test? Precision Examination? Surgery │700 ┃
┃ │ General Operations?Manufacturing?Sales │300 ┃
┃ │ Packaging? Washing │150 ┃
┃ │ Other │70 ┃
┠────┼──────────────┼──────────────────┨
┃4. Assembly │ Meeting │300 ┃
┃ │ Assembly │150 ┃
┃ │ Performance? Viewing │70 ┃
┠────┼──────────────┼──────────────────┨
┃5. Entertainment │ Entertainment General │150 ┃
┃ │ Other │30 ┃
┠────┴──────────────┼──────────────────┨
┃6. Other │Among columns 1 to 5, the most similar use ┃
┃ │Apply standards regarding the degree. ┃
┗━━━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━┛