Annex 3 — 건축물의 설비기준 등에 관한 규칙

279459 · 2025-10-31

■ Rules on Standards for Building Facilities, etc. [Appendix 3-2] <Amended Nov. 5, 2010> Installation Standards for Water Supply Pipes and Water Meter Protection Boxes (Related to Article 18, Subparagraph 3) 1. Thickness of insulation for water supply pipes (Unit: mm) ┏━━━━━━━━━━━━━━━━━━┯━━━━┯━━━━┯━━━━┯━━━━┯━━┓ ┃Pipe Diameter (mm, Outer Diameter) │Less than 20 │20 or more │50 or more │70 or more │100 ┃ ┃InstallationLocation │ │~ │~ │~ │or later┃ ┠───────┬──────────┤ │Less than 50 │70 Less than │100 │ ┃ ┃·Exposed to the outside air │Design ambient temperature (°C) │ │ │ │less │ ┃ ┃piping ├──────────┼────┼────┼────┼────┼──┨ ┃·Rooftop etc.│-Less than 10 │200 │50 │25 │25 │25 ┃ ┃freeze is │ │(50) │(25) │(25) │(25) │(25)┃ ┃The concern is ├──────────┼────┼────┼────┼────┼──┨ ┃Part of the shaft │-5 Less than ~ -10 │100 │40 │25 │25 │25 ┃ ┃ │ │(50) │(25) │(25) │(25) │(25)┃ ┃ ├──────────┼────┼────┼────┼────┼──┨ ┃ │0 Less than ~ -5 │40 │25 │25 │25 │25 ┃ ┃ │ │(25) │(25) │(25) │(25) │(25)┃ ┃ ├──────────┼────┴────┴────┴────┴──┨ ┃ │0 Maintain above │20 ┃ ┗━━━━━━━┷━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━┛ 1) ( ) is used when installing an electric heating cable that operates automatically according to a drop in temperature Standards for relaxing insulation thickness 2) The thermal conductivity of the insulation material shall be 0.04 kcal/m²·h·℃ or less, and the Korean Industrial Standard product Use 3) Design ambient temperature: According to the energy conservation design standards pursuant to the provisions of Article 59, Paragraph 2 of the Act to follow 2. Water meter protection box (excluding those installed in heating spaces) a. Install the water meter, shut-off valve, and check valve underground or inside the wall of a multi-unit dwelling In the case of installation, it shall be protected by placing it in a protective container made of concrete or synthetic resin, etc. b. Attach insulation material to the side, back, and front panels inside the protective enclosure (the insulation material is dense Use Korean Industrial Standard products with high conductivity and low thermal conductivity) . The pipe inlet and outlet of the protective box shall be sealed with insulation material, etc., to prevent the intrusion of cold air. d. Fill the space between the thermal insulation and the meter with insulating material such as fiberglass. E. Fill the gap between the protective tube and the wall with sealant, etc., to prevent the penetration of cold air.