■ Rules on Standards for Building Facilities, etc. [Appendix 3] <Amended May 11, 1999>
Diameter of water pipes in residential buildings (related to Article 18)
┏━━━━━━━━━━━┯━┯━━┯━━┯━━┯━━┯━━━━━━━━━━━┓
┃Number of households or families │1 │2·3│4·5│6~8 │9~16│17 or higher ┃
┠───────────┼─┼──┼──┼──┼──┼───────────┨
┃Minimum standard for water pipe diameter│15│20 │25 │32 │40 │50 ┃
┃(millimeter) │ │ │ │ │ │ ┃
┗━━━━━━━━━━━┷━┷━━┷━━┷━━┷━━┷━━━━━━━━━━━┛
Remarks
1. In buildings where the distinction between households or generations is unclear, floors used for residential purposes
The number of households is calculated as follows based on the sum of the areas.
A. Floor area 85 square meters or less: 1 household
B. Floor area exceeding 85 square meters and up to 150 square meters: 3 households
. Floor area exceeding 150 square meters and up to 300 square meters: 5 households
d. Floor area exceeding 300 square meters and not exceeding 500 square meters: 16 households
E. Floor area exceeding 500 square meters: 17 households
2. By installing pressurizing equipment, etc., the pressure at each fixture supplied with water is 0.7 kJ per centimeter
, the standards in the table above may not be applied.