Annex 1 — 건축물의 설비기준 등에 관한 규칙

279459 · 2025-10-31

■ Rules on Building Equipment Standards, etc. [Appendix 1-7] <Amended Aug. 7, 2024> Ondol Installation Standards (Related to Article 12, Paragraph 1) 1. Hot Water Ondol a. Hot water ondol refers to hot water generated from a boiler or other heat source Refers to a heating method that uses water flowing through pipes installed in the floor. . B. Hot water underfloor heating consists of a base layer, an insulation layer, a filling layer, and a piping layer (including heat radiating pipes) It consists of START and finishing layers, etc. ┌────────┐ │Upper finishing layer │ │ │ │Piping layer (heat dissipation pipe) │ │ │ │Fill layer │ │ │ │Insulation layer │ │ │ │Background Layer │ │ │ │ │ └────────┘ 1) The term "base layer" refers to the lowest or middle layer of a building where an ondol is installed. refers to the doctor. 2) An insulation layer refers to the heat released from the piping layer of the hot water underfloor heating system descending to the base layer To prevent loss, insulation material between the piping layer and the base layer refers to the floor where it is installed. 3) The filling layer refers to height adjustment of the ondol structure, improvement of sound insulation performance, and auxiliary thermal insulation Installing cushioning material, etc. between the piping layer and the insulation layer for functions, etc. refers to the layer. 4) The term "piping layer" refers to a layer on which heat radiating pipes are installed above an insulation layer or a filling layer. . 5) A heat dissipation pipe is a pipe layer used to circulate hot water that emits heat Refers to the hot water piping being installed. 6) A finishing layer refers to installing cement, mortar, plaster, etc., on top of the piping layer or Refers to the floor where final finishing materials, such as flooring and vinyl flooring, are installed. . Installation standards for hot water underfloor heating 1) The insulation layer, pursuant to Article 15, Paragraph 1 of the "Act on Support for the Creation of Green Buildings," the National Land It must comply with the standards notified by the Minister of Transportation, and for floor heating To prevent heat loss to the base layer and sidewalls, thermal material must be installed between the heat dissipation pipe and the base layer. However, the Ondol utilizing late-night electricity that directly uses thermal storage (under the "Korea Electric Power Corporation Act") Applicable only to nighttime electricity usage devices that have received approval from KEPCO in accordance with [] and in the case of (hereinafter referred to as "ondol using late-night electricity"), the insulation material Can be installed below the bathtub layer. 2) The thermal resistance between the piping layer and the base layer is [Green Building Construction Support Act] In accordance with the standards prescribed and notified by the Minister of Land, Infrastructure and Transport pursuant to Article 15, Paragraph 1 must combine. 3) The insulation material must have heat resistance and durability, and the live load on the insulation layer and having the strength to withstand fixed loads or installed as such a structure must be. 4) In cases where the base layer is in contact with the ground, the area below the base layer and the surrounding walls at high must be waterproofed to a thickness of at least 10 centimeters, and the upper part of the insulation . 5) The heat dissipation tube must be resistant to corrosion and capable of withstanding heat, and the bottom It must be installed so that the surface temperature of is uniform. 6) The piping layer ensures that the heat released from the heat radiating tubes is as uniform as possible to the finishing layer area It must have a height and structure capable of being transmitted. 7) The finishing layer must be installed level to prevent cracks in the floor In order to START, sufficiently cure or dry the finishing material to prevent warping or Must ensure that there is no deformation. 8) Using prefabricated hot water underfloor heating plates according to Korean Industrial Standards, hot water underfloor heating In the case of construction, provisions 1) through 7) shall not apply. 9) In addition to what is stipulated in 1) through 7), the Minister of Land, Infrastructure and Transport [may] hot water underfloor heating Matters necessary for the installation of may be determined and announced. 2. Gudeul Ondol a. Gudeul Ondol refers to the... that occurs when briquettes or other combustible materials burn... Passing air heated by smoke and combustion heat through the bottom refers to the method of performing the room. B. Gudeul-ondol consists of a firebox, ondol ventilation opening, air intake, flue, chimney, and chimney and others. 1) An agun is a device that generates heat through the combustion of combustible materials such as briquettes or wood MTQ8845b68899840b0703193Refers to the part that initiates START. 2) An ondol ventilation opening refers to the space where the fireplace is installed, for combustible materials such as briquettes A passage for smoothly discharging gases generated through combustion says. 3) An air intake refers to the space where a fireplace is installed, of combustible materials such as briquettes refers to a passage for supplying air necessary for combustion from the outside. 4) A gorae is where combustion gases and heated air generated in the firebox travel up the chimney To ensure it flows as evenly as possible under the floor before discharge . A chimney refers to the combustion gases and heated that have passed under the gudeul through the flue. refers to a device for smoothly discharging air to the outside. The chimney neck refers to the entrance connecting the flue to the chimney and its surrounding area. . . Installation standards for Gudeul Ondol 1) Where there is a briquette stove, so that briquette gas can be smoothly discharged Ventilation holes covering an area of ​​at least one-tenth of the floor area or Ventilation equipment must be installed, and at the lower part of the wall facing the outside air... To promote the combustion of briquettes, a diameter of 10 centimeters or more and 20 centimeters An air intake of less than must be installed. 2) The whale-shaped floor is designed with height/horizontal distances to facilitate the smooth discharge of briquette gas The size must be at least 1/5. 3) To guide smoke into the flue of a traditional Korean stove-style briquette firebox, a guide pipe When installing, a slope of 20 degrees or more and 45 degrees or less must be provided. 4) The cross-sectional area of ​​the chimney shall be at least 150 square centimeters, and the chimney neck The cross-sectional area of ​​ must be larger than the cross-sectional area of ​​the chimney. 5) When installing a Gudeul using traditional methods rather than a briquette-type Gudeul Ondol shall not apply the provisions of 1) through 4). 6) In addition to what is stipulated in 1) through 5), the Minister of Land, Infrastructure and Transport [may refer to] Gudeul Ondol Matters necessary for the installation of may be determined and announced.